| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A 3 19 DAL MILL ROAD UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical PLOT NO 13 SHAKTI KHAND II INDRAPURAM GHAZIABAD 201014 | GHAZIABAD | UTTAR PRADESH | 201014 | Rejected-Technical document not submit as per NIT |
| 5 | Rejected-Technical | Rejected-Technical document not submit as per NIT |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
24 Mar 2023, 3:00 pmClosed
Manager Electrical
Manager Electrical at Pragati Maidan New Delhi
Supplying and laying of Cable for providing electric supply to gate No.-1 and nearby building, from electrical substation No-1 at Pragati Maidan, New Delhi.
2023_ITPO_745745_1
169-ITPO(9/)E-E/22-23/133
Open Tender
Electrical Works
Item Rate
30 days
pragati maidan new delhi
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
Yes
ITPO
₹50,000
Yes
3 Apr 2023
17 Mar 2023
27 Mar 2023
17 Mar 2023
24 Mar 2023
17 Mar 2023
Amount
Supplying of following rating PVC sheathed/ XLPE insulated, Aluminium armoured conductor power cable of 1.1 KV grade, extruded PVC Type ST2 sheathed, 650/ 1100v grade as per IS 7098 (Part 1) 1988 etc as required (Make: Havells, Polycab, RR Cables, KEI etc.)
3.5 x 300 SQ mm cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc. As required, but excluding sand cushioning and protective covering.
Above 185 sq. mm and upto 400 sq. mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 185 sq. mm and upto 400 sq. mm (clamped with 25/40x3 mm MS flat clamp)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer – in – charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.
Bituminous portion
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 300 sq. mm (70mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
3.5 x 300 Sq. Mm.
Shifting the cubical panels having size 1700mmx1200mmx600mm after removal from the existing foundation in compact form along with disconnection of existing cables and repairing of damaged part, denting and painting with the existing colour after removal of rust and applying primer, making foundation 35 cm above ground level with cement concrete to another location, installation of cubical panel, connecting all the cables etc. complete as required.
Fabrication, installation, testing and commissioning fully compartmentalized powder coated floor mounted cubical panel having size 1200mmx600mmx600mm deep, suitable for use on 415V, 50Hz, AC supply, CPRI approved, having 2 mm thick CRCA sheet, dust and vermin proof with ventilation louvers, sectionalised detachable gland plates, totally enclosed compartmentalised front operated cubical type with 4 strip aluminium bus bar of 250A capacity with 2 termination points for earthing strip, din bar, MV danger notice plate, suitable gaskets, protection, interconnections, cable alleys, panel board on suitable MS iron frame made out of 50mmx50mmx6mm thick and along to be embedded in cement concrete foundation 35cm above ground level along with 3 pole, 35KA, 250A TPMCCB with spreader link, digital multifunction meter (for measuring voltage and ampere) 3 nos. LED indicating lamp with toggle switch, ON/OFF indication, locking arrangement, earthing studs, painting etc. as required (Make: Neptune, Tricolite, ADLEC, Platinum Control etc.)
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
200A, 25 KA, TPMCCB
250A, 35 KA, TPMCCB
400A, 35 KA, TPMCCB
Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120mm & ID-103mm nominal)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
NANDI ELECTRICAL WORKS
SANJAY POWER PROJECTS PVT. LTD.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .