Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC BACKSIDE SHIV SHANKAR TRALLA UNION SUNAM 148028 PB | SUNAM | SANGRUR | PUNJAB | 148028 | L1 | Accepted-AOC Rates are Reasonable | |
| 2 | L2₹9.8 L+₹33,992.88 (3.60%)Rejected-Finance 243 3 NEAR GOVT BOY SCHOOL BHAMNA PATTI SAMANA PATIALA | SAMANA | PATIALA | PUNJAB | L2 | Rejected-Finance Rates are higher than L1 |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
14 Oct 2019, 5:00 pmClosed
EXECUTIVE ENGINEER, DIV.NO.1, PATIALA
EXECUTIVE ENGINEER, WATER SUPPLY AND SANITATION DIV.NO.1, PATIALA
Construction of Toilet Block at Government College for Girls, Patiala
2019_WSS_38296_1
E-TENDER-10/WSSD/DIV.NO.1 PATIALA/EE/2019-20
National Competitive Bid
Civil Works - Buildings
Item Rate
90 days
Government College for Girls
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
TIA
₹19,600
Yes
19 Feb 2020
27 Sept 2019
15 Oct 2019
27 Sept 2019
14 Oct 2019
27 Sept 2019
Amount
Civil Works
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation
Providing & Applying of anti Termite Treatment using pre constructioinal chemical treatment measures as per IS : 6313 - 2001 (Part 2 ) & using Chemical containing Chloropyrifos systemic insecticide diluted to manufacturer' s specifications (i) in foundation pits, by treating the bottom & sides upto height of 300 mm by uniformly spraying solution @ 5 litre / sqm. (ii) Inthe refill earth on both sides of all built up walls @ 7.5 litre / Running meter (width 300 mm, depth 450 mm ). (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 litre solution per sqm.
Cement concrete 1:5:10 with stone ballast 40 mm gauge in foundation and plinth using concrete mixer volumetric type
Reinforced cement cocrete M-20 mechanically mixed in concrete mixer as per IS: 1791 but excluding vibrator and excluding steel reinforcement, centering and shuttering in foundation and plinth.
Reinforced cement cocrete M-20 mechanically mixed in concrete mixer as per IS: 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering in superstructure.
Centering & Shuttering for faces of concrete foundations and foundation beams & plinth beams (Vertical or battering)
Centring and shuttering for sides and soffits of beams haunching, girders, bressumers, lintels.
Centring and shuttering for flat surface such as Suspended floors, Roofs, Landing, Chhajjas, Shelves etc.
Extra for Smooth Surface of Ceiling
Cold twisted deformed (ribbed/ tor steel) Bars, Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
115 mm thick brick wall laid in 1 :4 cement sand mortar in super structure.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement
Cement concrete 1:2:4 gola 10 cm. x 10 cm. quardrant along junction of roof with parapet wall finished smooth, where specially specified.
Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS:13592 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item)
Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and fixing in position Grating 150 mm x 150 mm on top Khura, PVC Grating
12.5 mm thick cement plaster in c.m. 1:5
20 mm thick cement plaster in c.m. 1:5 two coat work
12.5 mm thick cement plaster in c.m. 1:4
20 mm thick cement plaster in c.m. 1:4 two coat work
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Earth filling underfloors with soil taken from outside including loading, unloading & carriage with average lead of 10 km., manually ramming, watering, laid into layers coplete in all respects.
Base course of floor consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand filling
Providing & Fixing of pressed steel sheet frames (Chowkat)consisting of 18 gauge (1.25 mm) steel sheet the specified section (standard design latest), including iron lugs (hold fasts), iron hinges confirming to PWD Specifications including bolts for fixing steps , lock notch provisioin for recieving tower bolts and finished with two coats ready mixed painted lead non setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for fitting in the frame and cement concrete 1:2:4 for lugs complete.
Doors & Window frame size 113mm x 60mm with 35mm wide single rebate weighing 3.38 kg per meter
Doors & Window frame size 151mm x 60mm with 35mm wide double rebate weighing 3.95 kg per meter
Providing & Fixing of Box type steel windows, made of various ERW section outer 60 mm x 25 mm, central mullion 60mm x 25mm, for shutter 50 mm x 25mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash welded with iron fitting including necssary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing & wire gauge) and finished with ready mixed paint read lead non setting primer complete as per specification, drawing and to the entire stisfaction of Engineer - in - Charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod complete fixed in positioin.
Supply and fixing of glass panes with glazing clips and special metal sash putty of approved make
Glass panes 4mm thick above 0.40 sqm area
Extra for providing and fixing steel Tube beading size 12mm x 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal sash putty in steel doors, windows, & ventilators complete in all respect.
Wire gauge fixed on steel windows of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5mm width , fixed with machine screws complete in all respect.
Factory manufactured flush door fixed in position iron hinges etc. (excluding the cost of any fittings other than specified above but including the labour for fixing the same in position. (Code : II Revision IS - 2191 Part-I) 1973
Commercial with elm or gurjen facing on both sides with laminated core and lipped edges. 35 mm thick
Cost of Aluminium fitting complete for doors, windows such as tower bolts, handles and screw etc.for these fittings. ( Excluding sliding bolt)
For shutter area above 0.5 sqm
Providing & fixing of hydraulic door closer ISI mark with necessary screws etc. complete. Aluminium sliding door bolts ISI marked anodized ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete.
ISI Designation no 1 (Size of door upto 700mm)
Providing & fixing of Aluminium sliding door bolts ISI marked anodized ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete.
300mm x x16mm.
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 10mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for stiles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the stiles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall puttyby applying two coats to get required finish.
Distempering with Acrylic washable oil bond distemper (of approved manufacture) two coats over one priming coat to give an even shade
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two coats to give an even shade.
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, varnish and chalk mitty including finishing the surface to required finish complete
Applying pink primer or Aluminium priming coat on wood work including preparation of surface and stoopping etc.
With ordinary quality paint
Painting two coats excluding priming coat with synthetic anamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
With ordinary quality paint
Applying priming coat with metal primer on new steel or iron work including preparation of surface
With ordinary quality paint
Painting two coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work
PLINTH PROTECTION
Earth work in excavation in foundations, frenches, etc. in all kinds of soil where pick jumper work lis not involved and not exceeding 2.0 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction including disposal of all surplus soil. as directed within a lead of 30 metres.
Cement concrete 1:8:16 with stone ballast 40 mm gauge in foundation and plinth using concrete mixer volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Providing & laying of 40 mm thick conglomerate floor
Cement floating coat with 1.5 mm thick neat cement
12.5 mm thick cement plaster in c.m. 1:4
CONSTRUCTION OF RAMP
Earth work in excavation in foundations, frenches, etc. in all kinds of soil where pick jumper work lis not involved and not exceeding 2.0 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction including disposal of all surplus soil. as directed within a lead of 30 metres.
Cement concrete 1:8:16 with stone ballast 40 mm gauge in foundation and plinth using concrete mixer volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Providing & laying out door Precast Designer Chequred Tiles of any size & any shape 25 mm thickness having top layer of white cement mixed with pigment, laid on 20 mm thick bed of ordinary cement mortar 1:3 ( 1 cement : 3 fine sand ) joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the satisfaction of Engineer - in - Charge.
12.5 mm thick cement plaster in c.m. 1:4
Providing and Fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts groutedon steps with hand rail and newel post of 50 mm dia stainless steel pipe , Balusters of 40 mm dia stainless steel pipe and guard 3 nos of 15 mm dia stainless steel pipe complete in all respect.
PUBLIC HEALTH SERVICES
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in built-up area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides leveling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects.
Earth work upto 1.5 m. Depth
All classes of soil except rocky
Providing, laying, jointing fixing and testing ISI marked G.I. Pipe (as per IS 1239) B-Class premium make such as (Jindal Hisar) including cost of specials (such as tees, bends,sockets, elbows etc.) Painting with anti corrosive bitumastic paint testing, cutting, threading Inside building complete.
Providing,fixing and jointing GI Union Couplings (of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.
15mm i/d G.I. Union
20mm i/d G.I. Union
25mm i/d G.I. Union
Providing, fixing and jointing ISI marked gun-metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.
15mm i/d Gun Metal peet valve heavy pattern.
20mm i/d Gun Metal peet valve heavy pattern.
Painting G.I. Pipes and specials with synthetic anamel paint in all shades as per I.S.I. Specificationson existing or new work two coats painting including cleaning, rubbing the surface etc.
Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good the same & finishing according to existing finish where required.
Through floor or roof 11.5cm thick
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition.
Size 75 mm x 75 mm
Cement concrete 1:6:12 with brick ballast 40mm gauge using concrete mixer mechanical type.
For 100 mm i/d S.W. Pipe Sewer line (type-1) 30 mtr @ 0.10 cum/mtr length
Providing and fixing in position Chinaware Indian Orisa water closet sizes 580mm (to the approval of the Engineer-in-charge) suite-consisting of 10 ltr. PVC flushing cistern supported on angle iron bracket including cost of long bend 32 mm dia complete in all respect and to the entire satisfaction of engineer in charge.
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in- charge) consisting of 10 ltr. PVC flushing cistern, PVC short band 32mm dia including cost of seat cover complete in all respect and to the entire satisfaction of engineer in charge.
Providing and fixing jet spray with 2'-6" long PVC pipe.
With C.P. Brass nut
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass waste 32mm dia, with one C.P. brass pillar tap complete in all respect.
560mm x 410 mm (above counter oval)
Providing and fixing in position towel rails/ Ring of approved make (to the approval of Engineer-in Charge) fixed in with rawl plugs ambeded in walls with brass screws complete in all respects.
CP Brass towel Ring
Providing and fixing in position C.P. Brass Soap dish of approved make (to the approval of Engineer-in Charge) fixed into wall with rawl plugs and CP brass screws complete in all respects.
Providing and fixing vitereous china ware standared pedestal of approved make ((to the approval of Engineer-in Charge) for wash hand basin complete in all respects.
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (approved make) complete with 4mm thick Hardboard backing fixed in with rawl plugs 50mm CP Brass Screws and washers & S/S studs on top complete in all respect (as required by the Engineer-in- Charge)
Size 550mmx400mm
Providing and fixing in position H.C.I. soil waste vent or antisyphonage pipes to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer - in - Charge) including cutting, jointing, wastage, but excluding cost of lead jointing.
100mm i/d H.C.I. pipe lines laid complete
75 mm i/d H.C.I. pipe lines laid complete
Providing Lead Caulked joints to H.C.I. Pipes and specials confirming to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer-in-Charge) including cost of lead,yarn,fuel and tools etc.
100mm i/d ( 1.36 kg )
75 mm i/d ( 1.13 kg )
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
M.S. Holder bats clamps for 100 mm i/d H.C.I. pipes
M.S. Holder bats clamps for 75 mm i/d H.C.I. pipes
Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer-in-Charge) of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. minimum depth of water should be 150mm with a minimum seal 50mm.
75 mm i/d outlet deep seal
75 mm i/d outlet shallow seal
Providing and fixing in position H.C.I special for soil waste vent or anti syphonage pipes to I.S.I specifications (IS:1729) of approved make (to the approval of Engineer - in - Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 100 mm i/d pipes
Heal rest Bend
Single junction with door
Single junction plain
Bend with plug
Bend plain
Cowls
Collar
For 75 mm i/d pipes
Heal rest Bend
Single junction with door
Single junction plain
Bend with plug
Bend plain
Cowls
Collar
Painting H.C.I soil waste and vent pipes and fitting with black bitumastic ISI marked paint of approved make (to the approval of Engineer-in-Charge) two coats on new work.
100mm i/d H.C.I. pipe lines
75 mm i/d H.C.I. pipe lines
Construciton of Brick masonary Plat form for over head water tanks mansory wall.
(i) For 1000 Ltr. Cap. Tank
Providing & fixing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer-in-Charge) with cover with suitable locking arrangment and making necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank.
Double layer tank
Providing and fixing in position automatic brass ball cock in tanks.
Plastic ball cock with rod & plastic ball
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mmx300mm and out of side size 330mmx330mm
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approved of Engineer-in-charge) Complete in all respects.
CP baras Bib Cock without flange
Providing & Fixing in postion stop cock / Angle valve of approved make to the approved of Engineer-in-charge) Complete in all respects.
C.P.brass 15mm concealed stop cock with flange
C.P.brass 15mm Angle valve without flange
Providing and fixing in PVC flexible tube connection of approved make (to the approved of Engineer-in-charge) Complete in all respects.
PVC tube connection of Size 15mm x 300mm with CP brass Nut
Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approved of Engineer-in-charge) with various fixtures complete in all respects
2Nos for each
Providing and fixing in position GI tank nipple of approved make (to the aapproval of EIC) in PVC wtater storage tanks complete in all respects.
G.I. Tank Nipple 20mm i/d
ESTATE SEWER
Excavation manually in trenches with straight or open cutting in built-up street/Lane having wall to wall width upto 3 meter for sewers and manholes to full depths as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion of traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas line etc. night signals, profiles, pegs, sights rails, boning roads, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 meter for all works other than connections to complete in all respects.
For depths not exceeding 2.0 metre B.G.L.
For all classes of soil except rocky
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
110 mm o/d pipes
Construction of brick masonry inspection chambers size as given below upto 0.60 m average depth in 1:5 cement sand mortar, lime concrete with 0 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
600mm x 900mm inside with 455mm x 455mm cover and frame medium duty double seal
Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design.
Construction of Septik tank of size 1.52 x 6.10 x 2.10 mtr including R.C.C. Cover complete in all respects.(as per detail attached)
CIVIL WORK
Anti-skid floor tiles 10mm thick in flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with white cement slurry in joints including corners angles and beading.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
ELECTRICAL WORK
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100volts grade to be laid in heavy gauge, PVC, fire retardant conduit pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/ anodized concealed metal boxes required for suitable number of modules, for having electronic fan regulators, bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20Amp. Sockets and 6Amp./16/20Amp. Switches (Screw Type Modular Accessories) etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/ sockets, step type electronic fan regulator 100watts, PVC connector (For Fan Box and Electronic Buzzer), Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) PVC conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:-
Wiring fan point with sheet metal fan box (shape hexagonal PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts.
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade.
Wiring 3 Pin 6 Amp. Plug control comprising wall socket (shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete.
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with double control switches.
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:
Supply and erection of PVC insulated single core FR copper conductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing.
PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq.mm, 1100volts grade
PVC insulated copper conductor single core FR cable (ISI marked) overall 4 sq.mm, 1100volts grade
PVC insulated copper conductor single core FR cable (ISI marked) overall 6 sq.mm, 1100volts grade
PVC insulated copper conductor single core FR cable (ISI marked) overall 10 sq.mm, 1100volts grade
XLPE/ PVC INSULATED UN-ARMOURED CABLES (ON SURFACE):
Supply and laying of XLPE/ P.V.C. insulated P.V.C. sheathed aluminium conductor un-armoured cable working voltage upto and including 1100 volts grade (on surface ) as per PWD General Specifications 2010:-
XLPE/ PVC insulated PVC sheathed aluminium conductor unarmoured cable working voltage 1100volts grade 35sq.mm (Three Core)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
Supply and erection of Miniature Circuit Breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles/lugs.
GROUP-A: (Siemens (Beta Guard), Legrand (Lexic) & Schneider (Neo Break), L&T EXORA (Hager)
Miniature circuit breaker single pole 6 to 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply
Miniature circuit breaker double pole 40amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply
Miniature circuit breaker four pole 63amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply
Miniature circuit breaker triple pole 32amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc.
GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T EXORA (Hager vision+)
Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 16 way each
COPPER EARTHING:
Earthing of Sheet metal/ iron clad switches and metallic cases etc., with 20 mm x 3 mm thick electrolytic copper tape rivetted (with 10 nos. copper rivets) to 30 cm x 120 cm x 3 mm thick tinned copper plate (made cylindrical) burried 10 metre below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper tape on wall and in floor etc., up to 13 metre in length (including bore length). G.I. pipe 20mm dia. (A-class) should be laid in the hole of excavation from bore surface level to 1 feet below ground level and having wire mesh funnel fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation.
S/E of Exhaust Fan 380mm sweep heavy duty including aluminium louver shutter. Complete in all respects as desired by the Engineer in charge at site. Make: Crompton Greaves Model No. Heavy duty Exhaust Fan with ISI Marked, Havell’s Make. Turbo force
Supply and erection of LED Batten 24 watt comprises of thermally conductive material pre wired with high efficiency electronic driver, high translucent frosted diffuser gets glare free, smooth light distribution complete in all respect as approved and desired by Engineer- in- Charge at site. Make :- Crompton LCCLB 24- CDL Cat No. Jaguar JLGO 0264- Glaze LED Batten- 24 W -LGLZ 01X024XC.
SUPPLY AND ERECTION OF WIRING ACCESSORIES:
Supply and erection of switches, sockets, power switch and sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including connections and petty material etc.
Ceiling rose (flush piano type)
Bakelite batten holder large size
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
Supply & erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications 2010:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) On Surface
Heavy gauge PVC conduit pipe 32mm dia. (ISI marked 2mm thick) On Surface
Supply & erection of pipe for wiring purposes including bends, inspection boxes etc., where necessary including painting as per PWD General Specifications 2010:-
Supply and erection of 20mm dia. heavy gauge welded conduit pipe (1.60mm thick) suspension rod for ceiling fan complete in all respect as desired by the Engineer-in-charge.
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size.
Double walled corrugated (DWC) HDPE pipe 90/76mm (outer/ inner dia.)
HARPREET SINGH CONTARCTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .