Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹26.0 CrAccepted-AOC | ₹26.0 Cr | l1 | Accepted-AOC L1 |
| 2 | L2₹27.0 CrRejected-Finance | ₹27.0 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹29.5 CrRejected-Finance 4A SWAIKA CENTRE POLLOCK STREET DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | ₹29.5 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹30.4 CrRejected-Finance 4A SWAIKA CENTRE POLLOCK STREET DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | ₹30.4 Cr | L4 | Rejected-Finance L4 |
| 5 | L5₹31.9 CrRejected-Finance | ₹31.9 Cr | L5 | Rejected-Finance L5 |
Tender Value
₹29.6 Cr
Closing Date
14 Oct 2021, 4:00 pmClosed
CE projects-JPDCL
office of CE Mohinder Mansion Sattelite colony JAMMU
HT/LT/SUB STATION WORKS IN BATOTE CIRCLE UNDER PMDP-U
2021_PDD_138646_1
CE/PJ/BATOTE/PMDPR/12 OF 2021-22
Open Tender
Electrical Works
365 days
BATOTE CIRCLE URBAN AREAS
AS PER SBD
4 documents required · 4 mandatory
₹25,000
ACCOUNTS OFFICER PROJECTS-JPDCL
Exempted
office of CE Mohinder Mansion Sattelite colony
4 Feb 2023
10 Sept 2021
16 Oct 2021
10 Sept 2021
14 Oct 2021
20 Sept 2021
10 Sept 2021 - 14 Oct 2021
16 Sept 2021
Amount
66/11 kV, 10 MVA, 3 Phase Power Transformer, Copper winding, On-load tap changer with HT and LT connectors
66/11 kV, 6.3 MVA, 3 Phase Power Transformer, Copper winding, On-load tap changer with HT and LT connectors
66/11 kV, 8 MVA, 3 Phase Power Transformer, Copper winding, On-load tap changer with HT and LT connectors
33/11 kV, 8 MVA, 3 Phase Power Transformer, Copper winding, On-load tap changer with HT and LT connectors
33/11 kV, 10 MVA, 3 Phase Power Transformer, Copper winding, On-load tap changer with HT and LT connectors
33/11 kV, 3.15 MVA, 3 Phase Power Transformer, Copper winding, Off-load tap changer with HT and LT connectors
33/11 kV, 6.3 MVA, 3 Phase Power Transformer, Copper winding, On-load tap changer with HT and LT connectors
66 kV, 1250Amp, 31.5 kA SF6 Circuit Breaker
Control & Relay Panel for protection of 66/11 kV Power Transformer with differential Relay (SCADA Compatible)
Control & Relay Panel for protection of 66/11 kV Power Transformer without differential relay (SCADA Compatible)
Control & Relay Panel for 66 kV Feeder VCB (SCADA Compatible)
66 kV, Multi Ratio , Multi Core , Single Phase Current Transformer
66 kV, Multi Ratio ,Multi Core , Voltage Transformer
66 kV Lightening Arrestors
66 kV, 800 A Isolator with Earthing Blade
66 kV, 800 A, Isolator without Earthing Blade
66 kV Post Insulator
Disc Insulators for 66 KV Line Bay
33 KV Disc Insulators complete with fitting
Control & Relay Panel for protection of 33/11 kV Power Transformer with differential relay (SCADA Compatible)
Control & Relay Panel for protection of 33/11 kV Power Transformer without differential relay (SCADA Compatible)
33 kV, 1250 Amp, 25 kA for 3 sec, Outdoor Vacuum Circuit Breaker
33 kV, 25 kA for 3 sec, Voltage Transformer, 33/0.11 kV
33 kV, 25 kA for 3 sec, Single Phase Current Transformer
Control & Relay Panel for 33 kV Feeder VCB (SCADA Compatible)
33 kV, 800 A, Isolator with Earthing Blade
33 kV, 800 A, Isolator without Earthing Blade
30 kV Lightening Arrestors
2 Core 2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
4 Core 2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
6 Core 2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
12 Core 2.5sqmm FRLS Type Cu. Control Cable, PVC insulated armoured including lugs, ferrules etc.
30 V Battery Bank ,100 AH,of 15 No. cells of 2V each,sealed maintaince free VRLA type ,high Impact polyprophelene coplymer conatiner ,flame retardant
30V, 100 AH,Float-cum booster charger ,with Full wave rectification for 220 V, 1 Phase , 50hz AC Input Supply.
Construction of RCC foundation for Power Transformers incuding guide rail, considering original equipment manufacturer recommendations including shuttering and by providing reinforcement, cement concreting in 1:1.5:3, painting etc as per Technical Specification, approved Drawings & Scope of works.
66 kV/33KV Yard Concreting/Metalling for new Substation) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 20mm single size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 20mm single size uncrushed/crushed/broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO as per Technical Specification, approved Drawing & Scope of works. & instructions of Engineer-in charge.
66 kV/33KV Yard Concreting/Metalling for addl Transformer Substation) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 20mm single size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 20mm single size uncrushed/crushed/broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO as per Technical Specification, approved Drawing & Scope of works. & instructions of Engineer-in charge.
Construction of RCC foundation for outdoor mounted 66 kV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting.
Construction of RCC foundation for 33 kV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting.
Construction of RCC foundation for 33KV Gantry Structures & other Equipments considering original equipment manufacturer recommendations including excavation of pit, shuttering and by providing reinforcement, cement concreting, painting etc as per Technical Specification, approved Drawings & Scope of works. Works also includes providing working platform for operation of breakers and painting. (for additional X-MER)
Chainlink Fencing of 66 kV/33KV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height (for new 66/11 KV or 33/11 KV Substation)
Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 820 mm)
Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 750 mm)
Cable Trench for laying of 11 kV XLPE Cables,Control Cables from switchyard to Control Room (for new 66/11 KV or 33/11 KV Substation)(Inner width 500 mm)
Compound walling of identified land by way of Mass Concrete in Foundations and 228 mm Brick Wall of 2 M height (for new 66/11 kV or 33/11 kV Substation) with provision of double beam.
Design, engineering & construction of Control Room Building for new 33/11 & 66/11 kV receiving substation (13mX8.5m c/c) consisting of RCC Slab including indoor trenches, comprising of battery room, panel room, store room, administration room, toilet etc as required of overall building size as per electrical requirement/ approved drawing ,single story including all internal services like water supply, Sewerage system, Finishing, Plinth Protection, including supply of construction materials, Labour, Cement, Reinforcement Steel, Frame Work, Excavation etc, complete in all resect including , Internal wiring, water proofing and roof projections of 600x600mm as per detailed Technical Specification, approved Drawings & Scope of works.
Development of land by removing weeds, wild grass, levelling and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas and road sides and development of roads along with surface drains and station FGL.
Borewell with submersible pump (at new receiving substation)
Earthing Mat with GI Flat 50x8 (for new receiving substation) with 50X6 risers.
Design, engineering & construction of Shift Quarters for JE and SBA at new 66/11 & 33/11 KV Substation as per instruction of Engineer-in-charge complete in all resect as per detailed Technical Specification, approved Drawings & Scope of works
Retaining Wall (RCC type)
Retaining Wall (Stone masonry type)
Soil Filling for new/additional substations
Earthing Electrode (3m long 40mm dia GI pipe) for Receiving Substation Earth Mat (New/Addl Transformers)
Yard Lighting of the new receiving sub station using 4 no , 12 meter long, GI High Mast poles ,continuously tapered of octagonal of cross-section ; including suitable shallow raft foundation using 8 nos 250 watt non integral flood light luminaire with single piece die cast aluminum housing and pot optic reflector and toughened glass cover, conforming to IP-66 complete with all accessories and suitable control feeder panel.
Earth Mat with GI Flat 50X8 & 50X6 risers for Additional Power Transformer
Earthing of Augmented Power Transformer
D.C Distribution Board with distributional Panel( 30V, DC) with 1 No. Amp Ckt. Breaker (for new Substations)
A.C Distribution Board with distribution panel (415 V,AC) complete with Ckt .breaker ,including Lamp etc (for new Substations)
Fire Fighting Equipment (for new Substations) a). Dry Chemical powder type(6kg) for control room -3No. b.) CO2 type of 4.5 kg Capacity for Control room- 4No. c). CO2 type trolly mounted of 22.5kg capacity for switch yard 2No.
11 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 3 Outgoing Panel) (SCADA Compatible)
11 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 4 Outgoing Panel) (SCADA Compatible)
11 kV, 1250 Amp, 25 kA for 3 sec, VCB Switchgear Panel Board (1 Incomer Panel + 5 Outgoing Panel) (SCADA Compatible)
11 kv Isolator double break 3 pole ,600 A with Earth switch
11 kV L.A for (66/11 kv S /s, 33/11 KV s/s & for DTR structure ) (10 kA Stn type.)
100 KVA, 11/0.4 KV Stn. Transformer, Aluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014 for (New 33/11 kV & 66/11 kV S/s)
11 KV XPLE Power Cables‐ 3C 120 mm²
11 KV XPLE Power Cables‐ 3C 185 mm²
11 KV XPLE Power Cables‐ 3C 300 mm²
11 KV XPLE Power Cables‐ 3C 400 mm²
11 KV XPLE Power Cables‐ Single Core 630 sq mm (With one spare length)
Indoor Type Cable Termination Kit for 11 kV 3C 120 mm² XLPE Cable
Indoor Type Cable Termination Kit for 11 kV 3C 185 mm² XLPE Cable
Indoor Type Cable Termination Kit for 11 kV 3C 300 mm² XLPE Cable
Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable
Indoor Type Cable Termination Kit for Single core 630 sq mm Cable
0utdoor Type Cable Termination Kit for 11 kV 3C 120 mm² XLPE Cable
Outdoor Type Cable Termination Kit for 11 kV 3C 185 mm² XLPE Cable
Outdoor Type Cable Termination Kit for 11 kV 3C 300 mm² XLPE Cable
Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable
Outdoor Type Cable Termination Kit for Single core 630 sq mm Cable
Disc Insulators for 33 KV Line Bay
Single Tension Fittings for Panther Conductor
50 mm² LT AB Cable (3X50+1x16+1X35 mm²)
70 mm² LT AB Cable (3X70+1x16+1X50 mm²)
120 mm² LT AB Cable (3X120+1x16+1X95 mm²)
35 mm² HT AB Cable (3X35+1X70 mm²)
50 mm² HT AB Cable (3X50+1X70 mm²)
70 mm² HT AB Cable (3X70+1X95 mm²)
120 mm² HT AB Cable (3X120+1X95 mm²)
Insulating Piercing Connetors
200 sqmm ACSR Panther Conductor
150 sqmm ACSR Wolf Conductor
100 sqmm ACSR Dog Conductor
50 sqmm ACSR Rabbit Conductor
30 sqmm ACSR Weasel Conductor
11/0.433 kV, 630 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
11/0.433 kV, 400 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
11/0.433 kV, 250 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
11/0.433 kV, 63 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
11/0.433 kV, 100 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
11/0.433 kV, 25 kVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings )
120 mm² LT 4 Core PVC Cable
400 mm² Single Core XLPE Cable (1100 V)
240 mm² Single Core XLPE Cable (1100 V)
185 mm² Single Core XLPE Cable (1100 V)
150 mm² Single Core XLPE Cable (1100 V)
120 mm² Single Core XLPE Cable (1100 V)
95 mm² Single Core XLPE Cable (1100 V)
70 mm² Single Core XLPE Cable (1100 V)
50 mm² Single Core XLPE Cable (1100 V)
25 mm² Single Core XLPE Cable (1100 V)
33 kV Pin Insulators with Pin
11kV Pin Insulators with Pin
11KV GO, AB Switch 200 Amp
11kV Disc Insulators complete with fitting
11 kV DO FUSE 100 A
33 kV Post Insulator
20 mm dia Stay Set complete with Stay Wire 7/4 mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy grip, thimbles etc
16 mm dia Stay Set complete with Stay Wire 7/3.15 mm, Turn Buckle, Bow, Tightner, Guy Clamps, Anchor Plates, Guy Insulators, Guy grip, thimbles etc.
Grouting of Stay Set as per TD/approved drawings
66 kV Disc Insulators Complete with fitting (11 kV * 6nos. = 01 no. (66 kV))
Suspension fitting for Wolf Conductor(66 kV Line)
Earthing of Poles & fittings by GI earthing Rod 20x2500 mm & 6 SWG GI wire
Tension Fitting for Wolf Conductor
8 Mtr. Long PCC Pole WL-250 Kg
11 Mtr. Long PCC Pole WL- 360 kg
9 Mtr. Long PCC Pole WL-300 Kg
16 Mtr. Long Steel Tubular Pole with welded steel base plate of Designation 410 SP -80 (IS 2713, Pt I, II, III 1980.)
13 Mtr. Long Steel Tubular Pole with welded steel base plate of Designation 410 SP -69 (IS 2713, Pt I, II, III 1980.)
11 Mtr. Long Steel Tubular Pole with welded steel base plate of Designation 410 SP -56 (IS 2713, Pt I, II, III 1980.)
8 Mtr. Long Steel Tubular Pole with welded steel base plate of Designation 410 SP -15 (IS 2713, Pt I, II, III 1980.)
9 Mtr. Long Steel Tubular Pole with welded steel base plate of Designation 410 SP -33(IS 2713, Pt I, II, III 1980.)
Stone Pad for PCC poles (400x400x75)
Aluminium Jointing Sleeves
Aluminium Paint
Red Oxide
Anti-Climbing Device with Clamps
Cement concrete foundation of ST Poles using cement concreting , 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings (tentative 0.45 cum/pole)
66 kV Danger Plates with Clamps
33 kV Danger Plates with Clamps
11kV Danger Plates with Clamps
440 V Danger Plates with Clamps
DLMS type Meter for DT Metering with Modem
Meter Box with Resin Cast Ring type CTs for DT Metering
Earthing LT Pole ( GI Earthing spike made of 20mm solid rod or 8 SWG earthing coil)
Earthing of Distribution Transformer - Pipe earthing.
11 kV Outgoing feeders- Pipe earthing.with GI strip
25mm dia GI Rod 3 M long for earth mat
Earth wire (7/4.00 sqmm)
Eye Bolts for guard netting
GI Wire 6 SWG, 8 SWG as per requirement for guard netting
Galvanised Steel Structures /GI Channel X-arm and GI V-cross arm including clamps and braces/GI Channels/Angle/ Flats of sizes.
Galvanized Nuts & Bolts
GI Barbed Wire for Anti Climbing with clamps (35 turns / pole)
GI flat for earthing 50x6 mm (for earthing risers for 33 kV Bay)
GI Strip 25x3 mm for earthing of DTR,
GI U-Clamps for Shackle Insulators
LT Distribution Box with mounting clamps for 25 KVA DTR with MCCBs with suitable incoming and outgoing ckts
LT Distribution Box with mounting clamps for 63 KVA DTR with MCCBs with suitable incoming and outgoing ckts
LT Distribution Box with mounting clamps for 100 KVA DTR with MCCBs with suitable incoming and outgoing ckts
LT Distribution Box with mounting clamps for 250 KVA DTR with MCCBs with suitable incoming and outgoing ckts
LT Distribution Box with mounting clamps for 400 KVA DTR with MCCBs with suitable incoming and outgoing ckts
LT Distribution Box with mounting clamps for 630 KVA DTR with MCCBs with suitable incoming and outgoing ckts
Transformer Pad (for 400 kVA & 630 kVA DTRs)
LT Line Spacers
MCCB ‐ 200 Amps (with Enclosure and pole mounting arrangement) for 100 kVA, 11/0.4 kV station Transformer
PG Clamps for 200 mm² ACSR Conductor
PG Clamps for 150 mm² ACSR Conductor
PG Clamps for 100 mm² ACSR Conductor
PG Clamps for 30 mm² ACSR Conductor
PG Clamps for 50 mm² ACSR Conductor
PG for LT AB Cable
Shackle Insulators with Pin
Sundry items like aluminium lugs, Jumpers, binding Tape, Droppers etc.
Suspension/Tension Clamp with eye hook
T Clamps for Panther Conductor
Wedge Connectors / PG Clamps
Straight Through for LT AB Cable Joining Kit
Soil Cutting
Approach Road to the substation land if required
LT 3 phase pole Distribution box with busbar LT service connection
35 sqmm 4C PVC Cable
Safety and operation instrument
Provision for Bus- bar & 11 kV supporting Structures (for Aug Transformers)
Heat Shrinkable Outdoor Cable Termination Kit
Mid Span Straight Throgh Jointing Kit for 11 KV ABC
ACDB for R&M 33/11 kv s/s
DCDB for R&M 33/11 kv s/s
New /Replacement 33kV VCBs for R&M 33/11 kv s/s
New 33kV C& R Panels for R&M 33/11 kv s/s (Scada Compatible)
New/Replacement of 33 kV Las for R&M 33/11 kv s/s
New/Replacement of 33 kV CTs for R&M 33/11 kv s/s
New/Replacement of 33 kV PTs for R&M 33/11 kv s/s
New/Replacement of 33 kV isolator with earthing blade for R&M 33/11 kv s/s
New/Replacement of 33 kV isolator with out earthing blade for R&M 33/11 kv s/s
11 kV VCB Switchgear Panel Board (Scada Compatible) (1 Incomer Panel + 4 Outgoing Panel) for R&M 33/11 kV S/s
Indoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 33/11 kV S/s
Outdoor Type Cable Termination Kit for 11 kV 3C 400 mm² XLPE Cable for R&M 33/11 kV S/s
11kV GO switich for R&M 33/11 kv s/s
11kV LA sets for R&M 33/11 kv s/s
Battery Bank for R&M 33/11 kv s/s
Battery Charger for R&M 33/11 kv s/s
Fire Extinguisher system for R&M 33/11 kv s/s
Power cable 11kV 400sqmm for R&M 33/11 kv s/s
VAISHNO ASSOCIATES VIDYUT PROJECTS LLP
LASER POWER AND INFRA PRIVATE LIMITED
CABCON INDIA LTD
Maa Harsiddhi Infra Developers Pvt. Ltd.
VIKRAN Engineering and Exim Pvt Ltd
powertech engineers
Nilshikhaa Projects Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid