Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹24.2 L+₹2.0 L (8.79%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 | |
| 3 | L3₹27.4 L+₹5.1 L (22.9%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L3 | Rejected-Finance REJECTED BEING L3 |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HQ 134 Wks Engrs
HQ 134 Works Engrs, Pin-914134, C/o 56 APO
REPAIRS/ MAINT OF HIGH TENSION DISTRIBUTION SYSTEM AND ALLIED WKS AT KHUNDRU AND KHANABAL UNDER GE 861 EWS
2020_MES_393591_1
134WE-59/2020-21
Open Tender
Civil Works
Item Rate
270 days
Srinagar
Please see tender documents
8 documents required · 8 mandatory
₹500
Yes
GE 861 EWS
₹66,000
Yes
12 Jan 2021
7 Nov 2020
11 Dec 2020
7 Nov 2020
9 Dec 2020
22 Nov 2020
60 days
Amount
M&L Strip opening of transformer and removing the top cover for draining the transformer oil and taking out the core alongwith HT/ LT coil (windings) assembling the core after replacement defective part, HT/ LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated new transformer oil and connecting, commissioning with existing electrical system HT /LT on load of capacity not exceeding 200 KVA including taking down and refixing complete all as specified and directed by EIC. Note : (i) Winding wire including labour for making coil and supply only of new spare for replacement of UNSV spare will be measured and paid separately. (ii) Transformer oil will be measured and paid separately
Supply only HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity upto 200 KVA.
Supply only LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, lacknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 200 KVA .
Supply only Top gasket made of 3mm thick cork sheet with suitable holes for transformer including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity upto 200 KVA.
Supply only Tapping switch/gear changer mechanism for variation of HT voltage in steps for transformer of capacity not exceeding 200 KVA .
Supply only breather assembly CI body of standard size filled with silica gel of transformer up to 200 KVA .
M&L for Winding of HT/LT coil of different type capacity and make of transformer with approved quality super enamelled copper wire/ strips of approved make of suitable gauge and number of turns alongwith allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. complete all as required at site or as directed by Engr-in-Charge.
M&L for Reconditioning of LT coil of aluminium/copper wound transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original complete all as specified and directed by Engr-in-Charge.
M & L for preparation of old steel surfaces of xpm jali and angle iron fixed on transformer plinth up to 500 KVA and painting with two coats of synthetic enamelled paint over a coat of red oxide primer and two coats of colour wash over a coat of white wash on plastered surface complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50/95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50/95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Taking out old UNSV cable and Supply, laying and testing HT cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 volts grade cross section area 95 sqmm 3 core complete laid in trenchers, duct, passing through pipe, fixed to poles complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and depth beyond 1.5m but not exceeding 3 metre deep and getting out in loose/ soft soil, complete all as specified and directed by Engineer-in-charge.
Excavation in trenches beyond 1.5m but not exceeding 3 metre deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge.
Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured.
Supplying and laying unreinforced precast concrete cable cover, class HV, type 2, flat, size 450mmx l80mm x 40mm, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of GI strip 32x6mm, buried in ground upto 50 cm or fixed to wall with insulators etc for loop earthing including welding for joints complete all as specified and directed by Engr-in-Charge. Note : Earth work will be measured and paid separetely.
S&F (in repair) Supply and fixing in replacement GOD triple pole 11000 Volts, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked form ground level for current rating upto 200 Amps with dropout fuse complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Pin type white, brown and green insulator including one galvansied mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm high, 150mm dia for 11000 volts grade, complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Disc type insulator, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts, complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Loop type insulator, vitreous, porcelain, white, brown or green insulator large size, with over all dimensions 90 x 140 mm, clearance of hole 25.5mm, complete all as specified and directed by Engr-in-Charge.
S&F in repair Stay assembly complete with accessories as shown in electrical plate No 1 as per SSR Part -I (2009), diameter of sty rod 16mm & MS plate 230x230x6mm thick, complete all as specified and directed by Engr-in-Charge.
S& F in repair Galvanised stay strand, size 7/4 mm complete all as directed including taking down the old unserviceable stay wire, complete all as specified and directed by Engr-in-Charge.
S&F in repair aluminium conductor steel reinforced any size in over head lines on HT poles including stretching the aluminium conductor and binding with binding wires of aluminium or aluminium tapes etc. Jumpers and connections, complete all as specified and directed by Engr-in-charge.
S&F (in repair) Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge.
Stretching the aluminium conductor on overhead line of HT pole and binding with binding wires of aluminium or aluminium tapes etc. jumpers and connections, complete all as specified and directed by Engr-in-Charge. Note :- (a) Necessary shut down to be taken by contractor from 33 KV/ 11 KV MRS before performing the repair. (b) Stretching of each conductor between two pole will be treated as one job.
Earthing complete with copper earth plate electrode 600x600x3.15mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.25mtr below normal ground level connected to the copper strip 20x3mm size by means of bolts ,nuts,check nuts and washers of copper and 20x3mm Copper strip protected by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for separately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistance is not obtained, the contractor shall redo the earthing without any extra cost to the department.
Supply and fixing and connecting galvanised iron earth strip 32 x 6mm size fixed in position with saddles complete all as specified and directed by Engr-in-Charge
M&L for replacement of copper strip of size 20mm x 3mm fixed to wall on batten, recess, chases for buried in ground, drawn in conduit/ ppe, fixed to poles or any other indicated situation for earthing complete all as specified and directed by Engr-in-Charge
M&L for servicing of HT 11KV, VCB installed at various locations including calibration by dismantling, cleaning, greasing the complete VCB with attached relays, bus bar etc, insulation testing, setting the contractor gap by measuring as required, reassembling the VCB and reinstalling back to its original position checking repairing the current, circuit panel wiring, relay testing (i.e. Primary and Secondary injection test)/setting of relay rating in 06 months intervals of all CT's and submitting the test report to Engr in Charge including provision of new spares as required complete including operational testing and commissioning all as directed. Note: (a) New spares, if required for repair/service of VCBs will be measured and paid separately. (b) Caliberation of relays and primary and secondary injuction test shall be conducted by authorises company/ manufacturers. Certificate of authority shall be produced by the OEM authorised company.
Supply only replacement of the following spares for VCBs 33/11 KV of any make all as directed :
Resin encapsulated Vacuum bottles suitable for 11 KV VCB panel of cap 400 Amp up to 25 KA as per existing.
Clossing coil 30V DC
Tripping coil 30V DC
11 KV porcelain bushing for VCB Top/Buttom
Operating switch (ON-OFF Lever)assembly
Manual charging/operating gear system assembly with operating hadnle of complete assembly
Digital type Earth fault & over current relay equivalent of L&T Mode No MC61A 24-110V
S&F (in repair) Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
Disconnecting HT/ LT side electrical connection carefully existing 11 KV/ 440 Volt stepdown transformer of any capacity, draining out and refilling of existing transformer oil after filtration dehydration and measuring the dielectric strength not less than 40 KV at 2mm gap including reinstallation of transformer satisfactory on its original position connecting testing and commissioning complete all as directed by Engr-in-Charge.
Supply and filling of resh transformer power oil of BDV not less than 50KVA for topping up reduced level due to evaporation/leakage/loss due to dehydration in HT transformer complete all specified and directed by Engr-in-Charge. Make : Power link/ Power oil/ Savita/ Midel
Replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous, enamelled white with letters. figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25x3mm MS flat, bolts and nuts for HT 25 x 20 cm size complete all as directed including taking down old danger notice plate, complete all as specified and directed by Engr-in-Charge.
S & F cable route indicator made out of 50x50x6mm angle iron, 60 mm long embedded in PCC block of suitable size with moulded letter ''HT cable'' suitable inscribed including PCC 1:3:6 type C2 (Using 40 mm graded aggregate block of 150x150x150mm size complete all as specified and directed by Engr-in-Charge.
Supply and laying 20mm thick graded coarse aggregate all around of the HT poles/ feeder panel/ station etc of bed 45cm thick, complete all as specified and directed by Engr-in-Charge.
M&L fo GI tubing light grade 80 mm dia with all fittings laid in trench or fixed on wall, along pole for protection of cable complete all as specified and directed by Engr-in-Charge.
S &F in replacement of Lighting arresters expulsion type complete with all fittings, suitable for volts 11000 V and discharge capacity 65 Kilo Amps complete all as specified and directed by Engr-in-Charge
Steel tubular swaged poles 11 meter long, type 410, SP-55 with 300mm x 300mm x 6mm mild steel base plate, finial taper plug, bolts, nuts and screws duly painted with two coats of anti-corrosive paint internally and externally complete including alternate black and yellow strips of 30 cm each of synthetic enamel paint upto 1.50 metre from GL and remaining external portion of pole painted with aluminium paint including writing number complete all as specified and as directed by Engr-in-Charge. Note : Excavation, earthwork and PCC shall be measured and paid separately
Plain cement concrete, (1:4:8), type D-2( using 40mm graded crushed stone aggregates) as in foundation filling & mass concrete for pole complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, (1:3:6), type C-1( using 20mm graded crushed stone aggregates) as in foundation filling & mass concrete for stay complete all as specified and directed by Engr-in-Charge.
4 mm dia galvanised steel wire (Chian link), 100x100mm mesh, 1.8 mtr high and 14 m long made up into mattresses or cages, lapped, wired and laid in position including excavation in posts holed of required size, getting out, returning filling in and remming and removing, including cement concrete type C2 1:3:6 (40 mm graded aggregate) including mild steel work as in posts and struts in fencing drilling holes notching for wire etc flat iron fillets with 8 Nos iron angle of size 65x65x6mm upto 1.8 mtr high and 60 cm in PCC under ground, including applying two coats of synthetic enamel paint over one coat of redoxide zink chrome primer.
Plain cement concrete (1:2:4), type B-1 (Ceiling 20mm graded crushed stone aggregates) as in copping filling including necessary firm work through finised all as specified and directed by Engineer-in-Charge.
M/S Noor Mohammad Shalla
M/S Sky Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .