Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-Finance | L1 | Accepted-Finance Lowest |
Tender Value
₹3.5 L
EMD Value
₹6,973
Closing Date
22 Mar 2025, 10:00 amClosed
EE WSD APWD Sri Vijaya Puram
EE WSD APWD Sri Vijaya Puram
Providing Separate Submain and circuit wiring for Air Conditioners in RCS office, VIP Road under Section III of Sub Division II, Workshop Division, A.P.W.D, Port Blair
2025_APWD_18088_1
NIT.255/NIT/WSD/2024-25
Open Tender
Electrical Works
Works
5 days
Sri Vijaya Puram
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹6,973
24 Mar 2025
20 Mar 2025
22 Mar 2025
20 Mar 2025
22 Mar 2025
20 Mar 2025
20 Mar 2025 - 22 Mar 2025
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for light / power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2Nos 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying, installing on wall, testing and commissioning of following capacity TPN Bus Bar Chamber of make Indoasian model cat no.CPPI1025 of 100 Amps capacity 4 way 4 nos, aluminium bus bars in convenient sections and suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply.
a) 100 Amps
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar,din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) 100 amps
Supplying of following sizes XLPE insulated heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to IS: 7098 (Part I) and IS No: 1554 (Part-I) 1988 as applicable.(make :Havells / Polycab/ Finolex. etc as required.
a) 35 Sqmm X 3.5 Core
Supplying of following size DWC HDPE PIPE along with all accessories like socket, couplers etc confirming to IS: 14930 PART- II Complete with necessary HDPE fittigs for protection of 1.1 KV grade under ground cable complete as required.
a) 50mm Outer Dia and 38 mm inner dia
laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size in the exising DWC/HUME/METAL pipe as required.
a) Upto 35 Sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a) Upto 35 sq. mm (clamped with 1mm thick saddle)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .