Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹82.7 L+₹1.3 L (1.56%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
8 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO CWE SGNR 43 OF 2021-22 PROVN OF THREE PHASE CONNECTION WITH ALLIED SERVICES AS PER NEW MAP PROVISION IN OFFICERS MD ACCN OF BHAGAT ENCLAVE AT SRIGANGANAGAR MIL STATION (2ND CALL)
2021_MES_487904_2
CA NO. CWE SGNR - 43 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
CLASS-C
CATEGORY-b(I)
10 documents required · 10 mandatory
₹1,000
₹1.5 L
Yes
27 Jan 2022
18 Dec 2021
10 Jan 2022
18 Dec 2021
8 Jan 2022
25 Dec 2021
60 days
Amount
Supply and fix industrial socket metal clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed by Engineer - in - Charge.
S & F in replacement of sub-main wiring with PVC insulated and un-sheathed 4 x 6.00 sqmm (Nominal Area) FR/FRLS stranded copper conductor drawn in and including PVC "medium quality" conduit as per size required including 2 x 6 Sqmm (Nominal area) copper cable as earth contiunity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note :- Four length of 6 Sqmm cable and two length of 6 Sqmm earth cable along with PVC conduit will be measured as one running length
S&F sub main two single core PVC copper conductor unsheathed wire multi stranded 4.00 sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including 4.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed by Engineer-in-Charge. Note :- Two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable along with PVC conduit will be measured as one running length
S&F sub main two single core PVC copper conductor unsheathed wire multi stranded 2.5 sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including2.5 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked. (Note :- two lengths of 2.5 sqmm cable and one length of 2.5 sqmm earth cable along with PVC conduit will be measured as one running length)
S & F in replacement sheet metal enclosure for double door BDs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F in replacement Sheet metal enclouser for doble door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 4 Way 415 Volt ISI marked 250Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N3 Frame upto 250A ,Isolators and including give connection with wire and cable etc complete all as specified and directedby engineer -in-charge
S&F in replacement MCCB TP & N 100 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S&F in replacement MCB TP&N 63 Amps with breaking capcity 10kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, AC supply 40 Amps, triple pole (TP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, AC supply 40 Amps, triple pole and(TPN) neutral with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing in replacement complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge
Excavation in trenches not exceeding 1.5 mtr wide and not ecxceedinf 1.5 mtr depth for laying of cables complete all as specified and directed by Engineer - in - Charge
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer - in - Charge
Removal of Excavated material n exceeding 50 mtr and depositing where complete all as specified and directed by Engineer - in - Charge
M & L for sand cushioning with dry and clean locally available sand for underground cable 8cm before laying cable and 15 cm after laying cable and punned to 10 cm after laying of cable complete all as specified and directed by Engineer-in-Charge (Note: Pressed thickness shall be considered for payment purpose)
Supply and lay standard size bricks subclass B type complete all as specified and directed by Engineer - in - Charge
Supply and lay jointing and testing and commissioning in replacement of 35 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supply and lay jointing and testing and commissioning in replacement of 25 Sqmm x4 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by engineer in charge.
Supply and fix 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection complete all as specified and directed by Engineer - in - Charge
S & F Rigid non-metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer - in - Charge.
Supply and laying in replacement GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc all as directd and specified by engineer in charge
Supply, installation, testing & commissioning of smart 3 Phase, 4 Wire, Pre-paid Energy Meters, BIS 15884 Marked in existing Meter Board / Floor Panels with Pre Payment Shock Proof capacitive touch Key pad, Bluetooth, based Digital having current range 10-60 Amp, 415 V, acucuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, containing provision for TOD & RTC, inbuilt feature sense the DG Mode through PLSI inbuilt in meter, dual source registration with respect to Grid as well as DG supply (wireless, without DCU, USB, Pendrive & Sim, no other extra equipent required for dual sence, meter it self capable for dual senceing) and dynamic load allocation facility from Grid and DG, capable to define 4 tariff slabs, happy hour & holiday definition all as specified and directed that the manufacturer or their service provider shall furnish 10 (Ten) years replacement guarantee for prepaid meters installed under this contract.(Cost of connecting to existing system is deemed to be included in the rates quoted) . (Make- Secure Model Liberty 370,L&T, Schneider) • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand. • Meter should have connect / disconnect functionality operable from prepaid billing software. Electric supply will be disconnected under following condition. (a) Over Current (105 % of Max current in any phase (b) Load control limit (Programmable) (c) Disconnection signal from utility control centre. • The meter should support open communication protocol DLMS with the software. MAKE: Secure, L&T, Schneider
Contd....... Note: (a) The contractor would be responsible from removing the existing meter carefully,making good the disturbed wiring, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters would carry 5 year warranty. (d) Whole work shall be executed through Origional Equipment Manufacturer (OEM). (e) Contractor will submit necessary MoU on Rs 100 stamp paper with OEM/Authorized rep (Who will provide all these facility mentioned above before commencement of work)
Supply, installation, testing & commissioning of Lib audit Software alongwith CMRI device for meter data analysis complete all as specified and directed by engineer-in-charge.
Provision of print, copy, scan, wireless Report Printer with 12 pages per minute capacity, 600 x 600 dpi with HP, REt, 1200 dpi effective output quality (600 x 600 x 2 dpi with REt, with duty cycle 3,000 single-sided pages per month for report printing complete as required, Make: HP LaserJet 1020 or equivelent in canon, Epson and Samsung printer all as specified and directed by engineer-in-charge.
Supply and Fixing of Impact token printer min 58 mm with serial/USB port having Thermal Receipt Printer Launch, High Speed Printing 90mm/sec, Compatible with ESC/POS Print Commands Set all as specified and directed by engineer-in-charge. M
Installation, Commissioning and implementation of vending system through server, mapping of consumers complete all as specified and directed by engineer-in-charge. Note: The cost of vending charges for meters commissioned during progress of work shall deemed to be included in the rates.
Supply, testing, laying of 6 core control cable to connect meter to Parallel Home Display split Unit for remote access of data / operation including two cable end connectors (RJ-11), punching complete all as specified and directed by engineer-in-charge.
Supply and fixing 25 mm dia medium grade, ISI Marked PVC conduit along with accessories laid on surface including cutting the wall and making good the surface to match with existing treatment all as directed and specified.by engineer-in-charge.
Taking down old meters of any size, noting down reading, removing and handover E & M stores all as directed.and specified.by engineer-in-charge.
Operation and maintenance of entire metering system including running of server by employing minimum 1 trained skilled personels in GE office shifts from 9 AM to 5 PM (except to Sunday & Holidays after completion of work for 12 months. The duties shall also include : (a) Managing vending station activities like coupen generation,meter recharge etc. (b) Rectifying any problem that may occur in the network and co-ordinating for smooth functioning of the system. (c) Deploying all measures for corrective actions as and when required . (d) Acting as a link between MES Users and parent company providing the metering system. (e) Providing hands on training to the MES Personel as and when required. (f) Collecting Cash and online payment details etc and handing over to MES designated Officer . (g) To provide any other associated technical support. (h) Running and maintaining server. Note : This Item shall be operative on declaring all meters commissioned.
Supply & fixing in replacement of meter box of size (1.0mX1.0mX0.25m) , thickeness 2.25 mm double door,made of CRCA sheet, single opening with lock arrangement ,transperent glass for meter reading, suitable for fixing 04 Electric meter & VTPN / TPN DB box , fixing new three phase meter with four core PVC copper conductor unsheathed wire multistranded 4 sqmm,properly painting on meter box complete and fixing in wall with suitable cutting,cement work etc all as specified and directed by engr in Charge
KPELECTRICAL AND AUTOMATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .