Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC H NO 816 NEAR GANDHI CHOWK KALKA 133302 HARYANA | KALKA | PANCHKULA | HARYANA | 133302 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.8 L+₹3.0 L (10.9%)Rejected-Finance 1291 1ST FLOOR SECTOR 26 PANCHKULA HARYANA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹33.7 L+₹6.0 L (21.5%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | m/s jupiter builders L1 | Pankaj Builders L3 | NSK TRADER L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed by Engr in Charge. | 22.6 | Cum | 300 ₹6,780 | 400 ₹9,040 | 200 ₹4,520 Lowest |
| 2.00 | Demolition of precast concrete articles and precast concrete block walling, built in cement mortar or cement lime mortar for ashlar facings, dressed stonework, complete all as specified and directed by Engr-in-charge. | 2 | Cum | 250 ₹500 Lowest | 400 ₹800 | 300 ₹600 |
| 3.00 | Dismantling of plain or corrugated steel sheeting, any guage, thickness from roof covering complete all as specified. | 344 | Sqm | 30 ₹10,320 Lowest | 30 ₹10,320 Lowest | 50 ₹17,200 |
| 4.00 | Dismantling wall and ceiling boards of any description or any thickness including cover fillets complete all as specified and directed by Engr in Charge. | 420 | Sqm | 5 ₹2,100 Lowest | 10 ₹4,200 | 50 ₹21,000 |
| 5.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engr in Charge. | 5.36 | Qtl | 500 ₹2,680 | 2,000 ₹10,720 | 200 ₹1,072 Lowest |
| 6.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. | 60 | Sqm | 15 ₹900 | 20 ₹1,200 | 10 ₹600 Lowest |
| 7.00 | Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr in Charge. | 80 | Sqm | 20 ₹1,600 Lowest | 20 ₹1,600 Lowest | 20 ₹1,600 Lowest |
| 8.00 | Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each. | 39 | Each | 200 ₹7,800 Lowest | 300 ₹11,700 | 200 ₹7,800 Lowest |
| 9.00 | Taking down chowkats or frames(without taking off shutters from the frame) area not exc 1.5 Sqm each. | 34 | Each | 150 ₹5,100 Lowest | 250 ₹8,500 | 200 ₹6,800 |
| 10.00 | Taking down shutter of any description exc 1 Sqm each. | 2 | Per leaf | 100 ₹200 Lowest | 200 ₹400 | 100 ₹200 Lowest |
Tender Value
₹40.8 L
EMD Value
₹81,500
Closing Date
11 Sept 2025, 6:00 pmClosed
GE 863 EWS
GE 863 EWS, C/O 56 APO
SPECIAL REPAIR TO BLDG NO T-296 T-187 AND T-189 AT AVERIPATTI IN THE AREA OF AGE BR-II PMS AND AGE EM (WE) POOH UNDER GE 863 EWS
2025_MES_724340_1
GE/863/EWS-T-35 OF 2025-26 SPECIAL REPAIR TO BLDG NO T-296 T-187 AND T-189 AT AVERIPATTI
Open Tender
Civil Works
Item Rate
180 days
AVERIPATTI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 863 EWS
₹81,500
Yes
14 Oct 2025
4 Aug 2025
13 Sept 2025
4 Aug 2025
11 Sept 2025
25 Aug 2025
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed by Engr in Charge.
Demolition of precast concrete articles and precast concrete block walling, built in cement mortar or cement lime mortar for ashlar facings, dressed stonework, complete all as specified and directed by Engr-in-charge.
Dismantling of plain or corrugated steel sheeting, any guage, thickness from roof covering complete all as specified.
Dismantling wall and ceiling boards of any description or any thickness including cover fillets complete all as specified and directed by Engr in Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engr in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr in Charge.
Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each.
Taking down chowkats or frames(without taking off shutters from the frame) area not exc 1.5 Sqm each.
Taking down shutter of any description exc 1 Sqm each.
Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified.
Taking up or down steel tubing 20 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified.
Demolition of RCC work of any description and any position.
Demolition and breaking up drain pipes(salt, glazed ware,AC or reinforced concrete) 200mm/150mm internal dia) of any description set in cement mortar.
M&L 25mm thick cement concrete type B-O, 1:2:4 (12.5mm graded agg ) as in sub base complete all as specified and directed by Engr in Charge.
M&L for Non-skid ceramic tiles, coloured, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified and directed by Engr in Charge.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified and directed by Engr in Charge.
M&L for Vetrified tiles light shade of 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified and directed by Engr in Charge.
M&L for 300x200x6-7 mm/450x300x6-7mm thick glazed coloured ceramic tiles as in skirting / dado incl 10mm thick back coat in CM 1:3 etc. set and jointed in neat cement slurry and pointed in coloured cement with pigment complete all as specified and directed by Engr-in-Charge.
M&L chequered cement concrete tiles 20cmx 20cmx 25/30cmx30cmx25cm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone agg as in sub base of floor complete all as specified and directed by Engr in Charge.
M&L 75 mm thick PCC 1:3:6 Type C-1 using 20mm crushed stone aggregate as in plinth protection and finished even and smooth without using extra cement including providing joints not exc. 2.00m in length & filling the joints with bitumastic filling (1:3) complete all as specified and directed by Engr in Charge
Bitumastic filling, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, as in plinth protection complete all as specified & directed.
M&L 1:3:6 type C-1 precast cement concrete (20mm graded stone aggregate) block masonary with solid blocks exc 10 cm in width and not exc 20cm in width and setting in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr in Charge.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr in Charge.
M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement(with water proofing compound) complete all as specified and directed by Engr in Charge.
Supply only Integral waterproofing compound as per manufacturer instructions complete all as specified and directed by Engr in Charge.
M&L two coats of cement base paint on plastered surface including preparation of newly plastered surfaces complete all as specified and directed by Engr in Charge
M & L for preparation of old plastered surfaces of wall including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coat of cement based paint complete all as specified and directed.
S&F in repairs 19/20 mm dia curtain rails mild steel chromium plated with fixing brackets, stops, roller etc, complete all as specified and directed.
S&F 6mm thick E board(classic) of size 610x610mm as in false ceiling fixed with aluminium snap grid frame work of same size as aluminium Tee of size 25x25x1.50mm as in main runner,25x25x1.25mm thick aluminium Tee as cross runner and aluminium angle of size 25x25x1.25mm at the perimeter including GI6mm adjustable suspender of required length of any description (Note:- The design and specification of the ceiling board to be approved by User/AGE/GE) , complete all as specified and directed by Engr-in-Charge.
M & L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed by Engineer-In-Charge.
M & L for Solid PVC Wall/Ceiling Lining consisting of 5mm thick any colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame incl corner & edges complete as per specifications and drawing complete all as specified and as directed by Engineer-In-Charge.
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m incl. necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each doors, hinges, anodiesed aluminium snap beading screw etc., complete all as specified and directed by Engr-in-Charge.
S&F Anodised aluminium frame of doors, windows & ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr in Charge.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle 100mm (1 no.) complete all as specified and directed by Engr in Charge.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n. exc 0.5 Sqm, each pane complete all as specified and directed by Engr in Charge.
S&F 4 mm thick Aluminium composite Panel for door including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws etc., complete all as specified and directed by Engr-in-Charge.
S&F solid PVC door frame of size 50 mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, in opening as per specification & drawing, complete all as specified and directed by Engr-in-Charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail on either side and as gap insert for top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to this stiles and rails with suitable PVC sheet beading and joined together with solvent cement, S&F in the frame at site as per specification and drawing all as specified in SSR Part-II 2020 section 8, complete all as specified and directed by Engr-in-Charge.
S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed by Engr in Charge.
S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr in Charge.
S&F 100mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr in Charge.
S&F 125mm aluminium handles cast type anodised and pattern/deseign as approved complete all as specified and directed by Engr in Charge.
S & F in repair butt hinges, 100mm medium weight, cold rolled mild steel complete all as specified and directed by Engr in Charge.
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engr in Charge.
Hacking out old broken glass (any thickness) , size, quality or description ) from metal frame including punching or drilling out old glazing pins complete all as specified and directed by Engr in Charge.
S & F in repair Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engr in Charge.
S & F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engr in Charge.
S&F in repair aluminium hat pegs, soild body, 125mm to 175mm complete all specified and directed by Engr-in-Charge.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including welidng cleats,distance pieces etc., complete all as specified and directed.
S&F Mild steel work as in compound girders and stanchions, latticegirders, aerial masts, staging for water tanks and like including caps bases, splices etc. built up from two or more beam or channel sections or angles with plates or pipe section including all lattice bars, stiffeners, gusset plates etc. (Fe-410-W(Gde E-250)Quality-A), complete all as specified and directed by Engr-in-Charge.
S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed by Engr in Charge.
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr in Charge.
M&L one coats of synthetic enamal paint to steel surfaces of any discription not otherwise described over 10cm width or girth preparation of old surfaces complete all as specified and directed by Engr in Charge.
S&F 2000 Ltrs capacity, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I, including 20mm ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed to 20 mm bore steel tube and dismantling existing water tank and removing complete all in repair as specified.
S & F 15 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified and directed by Engr in Charge.
Fixing only 15 mm water tubes, any grade, to walls and ceilings or laying in floors using GI tubing retrieved from taking down of tubing complete all as specified and directed by Engr in Charge.
S&F 20 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified and directed by Engr in Charge.
Fixing only 20 mm water tubes, any grade, to walls and ceilings or laying in using GI tubing retrieved from taking down of tubing floors complete all as specified and directed by Engr in Charge.
S&F in repairs bib taps, cast copper alloy, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore steel tube complete all as specified and directed by Engr in Charge.
S&F in repairs 15mm bore stop valve/angle valve cast copper alloy chromium plated fancy type screwed down, high pressure, with crutch or butter fly handles complete all as specified and directed by Engr in Charge.
S&F PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc and fixed in repairs, complete all as specified and directed.
Supply & fixing in repairs vitreous china wash basin, white, flat back of size 550mm x 400mm including 32mm dia PVC flush pipe with coupling and set of brackets including 15mm bore pillar tap fancy type cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule incl PVC connections 15mm size with PTMT nuts of legth 450mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm in repairs complete all as specified and directed by Engr in Charge.
S & F in repair chromium plated shower rose 125mm size with or without swivel joint any size incl fixing to steel pipe or union complete all as specified and directed.
S&F in repairs CP tubular towel rail, 20 mm dia. 60 cm long between flanges complete all as specified & directed by Engineer-in-charge.
S&F in repairs Soap dish, cast copper alloy, chromium plated with screws complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore, PVC (SWR) pipes single socketed/ elbow/ tee, in any length with rubber ring joints, laid in trenches or in floors inclusive dismantling old one complete all as specified and directed by Engr in Charge.
S&F in repairs 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors after dismantling old one complete all as specified and directed by Engr in Charge.
S&F in repairs 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr in Charge.
S&F for 110mm PVC (SWR) bends complete all as specified & directed by Engineer-in-charge.
S& F for 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified & directed by Engineer-in-charge.
S& F for 75/110mm PVC (SWR) reducer in repair complete all as specified & directed by Engineer-in-charge.
S& F for 110mm PVC (SWR) vent cowl in repair complete all as specified & directed by Engineer-in-charge.
S&F Vitreous china white wash down water closet (pedestal pattern) including PVC seat cover and connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, fixed as in repair, complete all as specified and directed.
Supply only Chromium plated jet for EWC, complete all as specified and directed.
S&F in repairs Vitreous china squatting pan 'Orissa pattern' size 580X 440 mm white with integral foot rest (including fixing of flushing cistern and flush pipe) including connection to trap, concrete and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor, complete all as specified and directed.
S&F in repairs vitreous china urinal half stall type flat back size of white with grating and union for discharge pipe including chromium plated water spreader , connection pipe and discharge down pipe complete all as specified and as directed.
M&L for preparation of old plastered surface of walls and applying one coat of white wash, complete all as specified and directed by Engr-in-Charge.
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified & directed by Engineer-in-charge.
M&L for precast RCC 1:2:4 type B-1 using 20mm graded stone agg as in cover slab and like axcept set in cement mortor 1:4 complete incl necessary form work all as specified.
M&L mild steel TMT bars 6-8mm dia bar cut to length, bent to shape required including cranking, bending spirally for hoping for fencing posts and binding with mild steel wire ( annealed) not less than 0.9 mm dia all as specified.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth for pipe line drains, foundations of sewage lines or manholes , taking up/taking down of cables and like and getting out in soft/loose soil complete alla s specified and as directed by Engineer - in - Charge.
Returning, filling in incl spreading ,levelling watering and well ramming in layer n exc 25cm in soil each layer complete all as specified and directed by Engineer - in - Charge.
Removing excavated surplus material to a distance n exc 50m and depositing where directed at level n. exc 1.5m above the starting point in any type of soil complete all as specified and directed by Engineer - in - Charge.
M&L cement concrete 1:4:8 type D-2 using 40mm graded stone agg as in bed to drain pipe, incl packing under and haunching against the sides of pipe 150mm bore after they are laid and tested complete all as specified & directed by Engineer-in-charge.
M&L 150mm internal dia reinforced concerete pipes, class NP2, laid and jointed complete with collars and jointed complete all as specified & directed by Engineer-in-charge.
M&L three coats of white wash on plastered surface including preparation of newly plastered surfaces complete all as specified & directed by Engineer-in-charge.
Demolition of septic tank and soakage well (constructed by engineers unit) including desilting/desludging the septic tanks / soakage wells etc. by manual labour or mechanical means and removing the sludge in liquid or semi-liquid state out side defence land complete all as specified and directed.
Construction of 20 users Septic tank to carry sewage and sullage water, with RCC (1:1.5:3), B-1 Roof Slab all as per shown in Drg No. STD 1320 (C) Sheet 1/3 to 3/3 with following specification. Excavation in any type of soil, precast cement concrete (20mm graded stone aggregate) C-1 block masonary in Walls , Base Slab , Baffle walls of RCC (1:1.5:3), Vent shaft , manhole openings with cover connection Complete. Note:- (i) precast cement concrete (20mm graded stone aggregate) C-1 block masonary in Walls as 700/600/500/400mm in lieu of 690/575/460/345mm respectively wherever shown in drawing. (ii) Stone boulders filling will be done in lieu of brick bats filling in lieu brick bats where ever shown in drawings.
Construction of Soak well 1.80m dia and 3.0m effective depth as specified on STD 1173(C) sheet 1R/2 with following specification free board as per site requirement in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of precast cement concrete (20mm graded stone aggregate) block masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with Stone boulders of size, complete all as specified on STD 1173(C) sheet 1R/2. Note:- (i) precast cement concrete (20mm graded stone aggregate) C-1 block masonary in Walls as 700/600/500/400mm in lieu of 690/575/460/345mm respectively wherever shown in drawing. (ii) Stone boulders filling will be done in lieu of brick bats filling in lieu brick bats where ever shown in drawings.
Desilting/desludging/dewatering of existing septic tanks/soakage wells of any capacity and any depth including taking out and removing sludge and accumulated solids / semi solid contents out side defence land in closed container more than to a pit of sufficient size and depth at a place 250 mtrs away from defence land and burried in ground including necessary excavacution, earth work and spreading of bleaching powder complete all as specified and directed by Engr in Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, excluding fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr in Charge.
M&L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for continous earthing in & incl casing capping point wiring with accessories having ISI mark for one light/fan/bell point/5 amp indep/power point/same board controlled by one switch complete all as specified and directed.
All as per item No 99 here-in-before but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board
All as per item No 99 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches
All as per item No 99 here-in-before but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board
All as per item No 113 here-in-before but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 4.0 sqmm multistranded FRLS copper cable, independent board
S&F in replacement of switch piano type 5 Amp, 230 Volt, flush type single pole one way complete all as specified and directed.
S&F in replacement of socket outlet multipin 5 Amp 230 Volt flush type complete all as specified and directed.
S&F in replacement of switch piano type 15 Amp, 230 Volt, flush type single pole one way complete all as specified and directed.
S&F in replacement of socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed.
S&F In replacement of for Lamp holder, PVC/Polycarbonate type with back plate suitable for Angle/batten fittings complete all as specified and directed
S&F of rechargeable led bulb minimum 4 Hrs Battery backup 9 Watt B-22 Base complete all as specified and directed.
S&F in replacement of Ceiling rose, 3 terminal, PVC isolated body complete all as specified and directed
S&F in replacement of LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in replacement LED light fitting 1x10W/1X12W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S & F including flushing in wall MCB distribution board vertical TPN 4 way 415 volt AC double door sheet with bus bar neutral earth bar including provision of MCB TPN 63 amp conforming to IP 43 as incomer complete all as specified and directed.
S&F MCB TPN 63 amp 415 volt with bearing capacity of 16 KA complete all as specified and directed.
S&F in replacement of sheet metal enclosure double door distribution board single pole and neutral, 8 way 240 volt with 100 amps rated bus bar complete with bus and neutral link complete all as specified and directed.
S&F in replacement of sheet metal enclosure double door distribution board single pole and neutral, 12 way 240 volt with 100 amps rated bus bar complete with bus and neutral link complete all as specified and directed.
S&F in replacement of MCB 6 to 32 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F in replacement of MCB SPN 40 amp2 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 16 sqmm 4 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed
Supply and laying of GI pipe light galvanized with all fitting laid in trenches for cable proctection of 50 mm bore all as specified and directed.
Supply, laying and drawing wiring circuit / submain and including 20 mm dia surface PVC rigid casing caping or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. (From AC Box to DB)
M&L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as directed.
Supply and fixing Building LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed.
Supply, laying and drawing in and including 20 mm dia casing caping including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. (From AC Box to DB) (Note:- Three run of 6 sqmm cable & 1 run of 20mm PVC casing caping shall be measured as one length.)
Supply and fixing of exhaust fan, steel body AC single Phase 230V of size 450m sweep heavy duty 1400 RPM with, blades, and frame and louvers complete all as specified and directed.
Supply and fixing of exhaust fan, single phase steel body AC single Phase 230/240V of size 300m sweep heavy duty 1400 RPM with, blades, and frame and louvers and including fixing exhaust fan complete all as specified and directed.
M&L for sand filling floors or in foundation including watering and compansation.
M&L for old size bricks common burnt clay building bricks sub class B designation 75
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with servicevalue 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
S & F in replacement of stepped type electronic fan regulator flush type, complete all as specified and directed
S&F for fixing of GI pipe (light grade) bracket of 40mm bore size of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc as specified and directed.
S&F single pole and neutral enclosure with a two pin plug and socket complete with one single pole MCB 32 Amp complete all as specified and directed.
Schedule of Credit
NSK TRADER (BID ID -3421003)
Pankaj Builders (BID ID -3417950)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .