Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 CrAccepted-AOC | ₹21.8 Cr Quoted ₹22.0 Cr | L1 | Accepted-AOC .. |
| 2 | ..₹22.6 CrAccepted-AOC VILL FAZALPUR BEHIND FOCAL POINT NEAR RANDHAWA MASADAN JALANDHAR | JALANDHAR | JALANDHAR | PUNJAB | ₹22.6 Cr | .. | Accepted-AOC . |
| 3 | ..₹23.4 CrAccepted-AOC B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | ₹23.4 Cr | .. | Accepted-AOC .. |
| 4 | ..₹24.1 CrAccepted-AOC | ₹24.1 Cr | .. | Accepted-AOC . |
Tender Value
₹21.2 Cr
EMD Value
₹21.5 L
Closing Date
12 Jul 2022, 11:00 amClosed
EE JSV Division Hamirpur
EE JSV Division Hamirpur Distt. Hamirpur
Work-Item Description as per NIT
2022_HPIPH_62255_1
No. EE-JSV-HMR-CB-et-22-23 10328-10428
Open Tender
Civil Works
365 days
JSV Sub Division SujanPur
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,500
Yes
EE JSV Division Hamirpur
₹21.5 L
Chief Engineer Jal Shakti Vibhag Hamirpur Zone
24 Apr 2023
28 Jun 2022
12 Jul 2022
28 Jun 2022
12 Jul 2022
28 Jun 2022
28 Jun 2022 - 12 Jul 2022
6 Jul 2022
Amount
Excavation in foundation and trenches etc. in all kinds of soils such as pick work, jumper work, blasting in soft/hard rock, chiselling/wedging out of rock/where blasting prohibited)saturated soil stacking the excavated earth within all leads and lifts clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposting of all surplus excavated earth as directed within all leads and lifts including uprooting of trees dressing of beds, and sides and preparation of sub-grade, restoration of unmetalled/metalled/paved surfaces to its original condition including soring, strutting, timbering and dewatering where ever houses, fixing caution boards, crossing over trenches and to the entire satisfaction of the Engineer-in-charge.
Earth work in foundation for digging well in dry excavation from gravel level upto the level where well curb is placed, including depositing spoil within all radius and filling space outside the well after completion from N.S. level to 1.5 meters depth in all kind of soil such as pick work,jumper work, blasting work Soft/hard Rock chiseling workSoft/hard Rock(where blasting is prohibited) complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Wet well sinking in gravel including all pumping, shoring etc.complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge..
From spring level to 3.00 mtr.depth
From spring level to 3.00 mtr. to 6.00 mtr.depth
From spring level to 6.00 mtr. to 9.00 mtr.depth
From spring level to 9.00 mtr. to 10.00 mtr.depth
Steel work welded in built up section , trusses and framed work including cutting,hoisting,fixing in postion and applying a priming coat of red lead paint,In gratings framed guard bars,ladders, railling,brackets and similar work. & as per the directioin and to the entire satisfaction of the Engineer-in-Charge
Lowering steel well curb in the pit and assembling in position in all depth complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing & laying cement concrete M-10 mix concrete using graded stone aggregate 40 mm nominal size, excluding the cost of centring & shuttering in Foundation & plinth complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing and laying cement concrete 1:4:8 (1cement:4sand:8 graded stone aggregate 40mm nominal size) curing complete excluding the cost of form works and suttering in foundation and plinth complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing & laying cement concrete M- 25 mix concrete using aggregate 20 mm nominal size) & curing complete excluding the cost of form work & reinforcement for reinforced concrete work complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Foundation,footing,bases of columns and the like & mass concrete in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
Wall (any thickness but not less than 0.10 mts.Thickness)attached pillasters,buttresses plinth,& string courses etc.from top of found.level upto floor two level as per direction and to the entire satisfaction of the Engineer-in-charge.
Suspended floors, roofs, landings and shelves and their supports, balconies, beams ,griders bressumers and cantilevers upto all floor level complete as per direction and to the entire satisfaction of the Engineer-in-charge.
Columns, Pillars & Posts Struts ( Square rectangular or polygonal in Plain). Upto floor to level
Arches upto floor two level
Providing & Laying no fine concrete 1:4 (1cement : 4 stone aggregate) complete in all respect in all respect in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
Prov.form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm,so as to give a fair finish i/c centring shuttering,strutting & propping etc. with wooden battens & ballies,ht. of propping & centring below supporting floor to ceiling not exceeding 4.00 mts. & removal of the same for in situ-reinforced concrete & plain concrete work in all leads & lifts as per direction and to the entire satisfaction of the Engineer-in-charge. :-
Vertical surfaces such as wall (any thick.) partitions & the like i/c attached pillasters,buttresses,plinth & string courses & the like.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors upto 200mm kin thickness.
Beams, cantilevers,girders & lintels, slides & soffits of beams, haunching, cantilevers, bressumers 1.00 mts in depth in all heights from floor.
Providing, Laying mild or tor steel reinforcement for RCC. Work including bending binding and placing in position complete upto floor two level Tor steel complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Square rubble masonry with approved quality i/c racking out of joints in foundation & plinth in CM 1:4 (1cement : 4 sand)complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Above NSL/GL
20mm cement plaster in single coat of rough sides of bricks / concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1 : 3 (1cement : 3 sand) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Brick masonry using common burnt clay Building bricks in foundation & plinth in CM 1:4 (1cement : 4 sand) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Prov. & fixing CI Man hole cover with frame having frames size of 500 mm internal dia.( Medium duty )The weight of cover & frame should not be less than 116 kg in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Providing 200 mm wide CI rungs with chequered or ribbed non slip surface i/c fixing in structure with 200 x 200 x 100 mm cement concrete 1:3:6 ( 1 cement :3 sand : 6 graded stone aggre 20 mm nominal size ) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Boulder/Stone filling dry hand packed tightly complete under lean conrete to prevent the entry of surface water in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Prov.form work of ordinary timber plankings so as to give a rough finish i/c centring, shuttering,strutting & propping etc. ht.of propping & centring below supporting floor to ceiling not exceeding 4 mts. & removal of the same for insitu-reinforced concrete & plain concrete work in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge:-
Arches beyond 6.00 mts.span
Prov.in RCC work smooth finishing of the exposed surface with cement mortor1:3(1cement :3 sand ) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Steel work welded in built up sections,trusses & framed work i/c cutting,hoisting & fixing in position & applying a priming coatof red paint :- In grating, framed ,guards,bars, ladders,railing,brackets & similar works in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Providing & laying in trenches GMS/MS Tubes (L/M class) tube fitting (Earth work in trenches to be measured & paid for separately) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Providing & fixing CI Sluice valve (with hand wheel) as per IS : 780-1984 class-I upto 300 mm dia.(i/c brass spindle & as per 2906-1984 class-II for dia.> 300 mm) complete with bolts nuts,rubber insertion etc.,(the tail piece if required shall be measured & paid for separatly) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
150mm dia
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia. & 180 mm deep(inside) with chained lid RCC top 1:2:4 mix (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) 100mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Provision of duck foot bends, Providing & fixing MS sheet locking arrangement for protecting the storage tanks, protection works with drain in an around the periphery of tanks & Bypass arrangement for cleaning of tanks in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Providing & laying cement concrete 1:2:4 (1cement :2 sand : 4 graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work & reinforcement for reinforced concrete work in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge :-
Foundation,footing,bases of columns and the like & mass concrete .
Construction of RCC framed pump house 6.0 mtrs height fully furnished, including Gantry system:-It also includes the provision of gantry system in pump houses for providing, fixing and testing as per site requirements 5 MT capacity.and attendent room, office, control station etc. in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
At Jungle Beri Stage-1 ( 3x150HP+6X12.50HP Mono Sub. +P.O. Room + Office + Control Station etc.)
At Bouru (Satge-2) (4x15HP + 2X120HP + 3X200HP + P.O. Room + Office + Control Panels etc.)
Provision for Solar teck stand dusk to dawn automatic operation with 74 watt Panel , 74 Ah tubular battery with 1 x11 watt CFL with two days autonomy with 5 mtres pole in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
Providing,laying, jointing and testing in trenches (to level or grade)(with 5% flanged joints and remaining 95% circumferencial butt welded joints) G.I pipes of below mentioned dia,wall thickness & grade conforming to IS:1239 ( Part-1)1990 (Latest upto date amendments) suitable to with stand required hydraulic test pressure including commissioning and cost of all fittings in all respects in Rising Main.The laying of pipe will include all operations such as cutting, welding, jointing, including flushing, cleaning and hydraulic testing complete in all respects to the entire satisfaction of Engineer-in-Charge including entire carriage of materials in all leads and lifts as per direction of Engineer - in Charge.Pipes will be measured for straight lengths only.(Earth work in trenches, M.S. Flange joints and butt welding joint will be measured and paid for separately) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
150mm dia GMS/IS1239-1990 Part-1
Providing, Laying, jointing and testing & Commissioning of GMSERW pipe L-290/L-210 grade conforming to IS 3183:2007(with 5% flanged joints and remaining 95% circumferencial butt welded joints) in trenches bevelled ended BIS marked PIPE to relevent codes & specification its equivalent latest with up to date ammendments of following dia with steel garde having wall thickness as mentioned below & capable of withstanding required test pressure as prescribed in BIS code , in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for but welding , including the cost of jointing with butt welding to IS 816-1969 or latest as appicable and with up to date ammendments (leak proof) in three layers at site of work with welding rods of standard make & all allied accesories whatever required for welding at site, tail piece, tees neds & other specials manufactured from parent pipes as applicable to the particular reach & of approved specifications as per site conditions and cutting of pipes wherever required as per site requirement i/c cariage in all leads & lifts as directed by Engineer-incharge. The pipe shall have zinc coating inside & outside to IS 4736-1986 or latest with up to date ammendments & shall be engraved with IS 3183:2007 for GMSERW pipe . The laying shall confirm to BIS 5822-1970 or latest with up to date ammendements to teh entire satisfaction of Engineer-Incharge (Earthwork & cost of MS flanges and butt welded joints shall be measured & paid for seperately) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
250 mm dia GMS/ERW Grade -L-290 or X42, T=4.80mm IS/ISO 3183 : 2007
250 mm dia GMS/ERW Grade -L-290 or x 42, T=6.40mm IS/ISO 3183 : 2007
250 mm dia GMS/ERW Grade -L-290 or x 42, T=5.60mm IS/ISO 3183 : 2007
250 mm dia GMS/ERW Grade -L-290 or x 42, T=5.20mm IS/ISO 3183 : 2007
65 mm dia MSERW Pipe IS/ISO:3183-2007,L210 or A , T=4.80mm
50 mm dia MSERW Pipe IS/ISO:3183-2007,L210 or A , T=4.80mm
150 mm dia GMS/ERW Grade -L-210, T=5.60mm IS/ISO 3183 : 2007
150 mm dia GMS/ERW Grade -L-210, T=4.80mm IS/ISO 3183 : 2007
Providing and welding M.S. flanges @ 5% of joints, conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) with plain end GMS/MSERW pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of MSERW pipes to be measured and paid for seprately). The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.
150mm dia GMS/IS1239-1990, FT-5
250 mm dia GMS/ERW Grade -L-290, FT-34
250 mm dia GMS/ERW Grade -L-290, FT-28
250 mm dia GMS/ERW Grade -L-290, FT-23
250 mm dia GMS/ERW Grade -L-290, FT-17
250 mm dia GMS/ERW Grade -L-290, FT-11
250 mm dia GMS/ERW Grade -L-290, FT-5
150 mm dia GMS/ERW Grade -L-210, FT-28
150 mm dia GMS/ERW Grade -L-210, FT-17
150 mm dia GMS/ERW Grade -L-210, FT-5
65 mm dia MSERW,L210, FT-28
65 mm dia MSERW,L210, FT-17
65 mm dia MSERW,L210, FT-5
50 mm dia MSERW,L210, FT-28
50 mm dia MSERW,L210, FT-17
50 mm dia MSERW,L210, FT-5
Providing circumferencial butt welded joints by electrical arc welding to GMSERW pipe grade L-290/L-210 as per IS 3183:2007 & GMS pipe heavy & medium grade as per IS 1239:1990 (part-1), welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerilikon (Adore)-CITOJET/ES/ESAB make,conforming to IS 814-1991, including Die pentration test, including fabrication ,laying & jointing requisite number of MSERW/GMS bends at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
150mm dia GMS/IS1239-1990
250 mm dia GMS/ERW Grade -L-290 or X42, T=6.40mm
250 mm dia GMS/ERW Grade -L-290 or X42, T=5.60mm
250 mm dia GMS/ERW Grade -L-290 or X42, T=5.20mm
250 mm dia GMS/ERW Grade -L-290 or X42, T=4.80mm
150 mm dia GMS/ERW Grade -L-210, T=5.60/4.80mm
65 mm dia MSERW Pipe Grade- L-210 , T=4.80mm
50 mm dia MSERW Pipe Grade- L-210 , T=4.80mm
Providing double flanged Cast Steel Non Return Valve, following class of Leader/ Kirloskar/Sachdeva / RG or any other approved make of following dia. for rising main and capable of with standing following normal seat pressure conforming to BS:1868/API-600 or latest ammendments. ( Class required as per site condition ) in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
50mm dia , Class ASA-300, 52 kg/cm2
65mm dia , Class ASA-150, 21 kg/cm2
65mm dia , Class ASA-300, 52 kg/cm2
150mm dia , Class ASA-150, 21 kg/cm2
150mm dia , Class ASA-300, 52 kg/cm2
150mm dia , Class ASA-600, 104 kg/cm2
250mm dia , Class ASA-150, 21 kg/cm2
250mm dia , Class ASA-300, 52 kg/cm2
250mm dia , Class ASA-600, 104 kg/cm2
Providing and fixing screwed type cast iron air valve of 25mm dia (single ball type) of Leader,Sachdeva, RG or approved make to BS : 1452-90 with upto date amendments as per class PN-10.00 to withstand a seat pressure 11.22 Kg/ cm2 in rising main in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
(Booster stage-I ) Supply & erection of Submersible clear cold & fresh water Pumping sets of reputed make such as KSB/Clama/SU/Johanston conforming to latest relevent BIS code. The pump should be fitted will free flow impellers of bronze/suitable alloy as per BIS 8034-1976 latest suitable for clear water having greased packed bearing and shaft with bound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti/ Cromptorn make conforming to relevent BIS Code latest with upto date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber & grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear & tear in all leads and liftsas per direction and to the entire satisfaction of the Engineer-in-charge.
6 Sets x12.50HP = 75HP (3 Working, 3 Stand bye).
Discharge (Q) 15.40 LPS for each pump.
Total head in Mts. 25.51 meters
(a) LWL in sump well (h) mtrs.
(b) Shaft level mtrs.
(c ) Level at discharge point mtrs.
(d) Suction lift mtrs.
(e) Residual head mtrs.
(f) Static head 19.00 mtrs.
Rising main
(a) Length 400 mtrs.
(b) dia 150 mm
Pumping hours 8 hours
Altitude of installation above MSL 425 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity 50 PPM
(d) Alkalanity
(e) Size of the solids
(f) Other
Supply of suitable soft Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release .
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitabe capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recomended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltage difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make actuated cast iron sluice valves having size one step higher then the delivery of pump and capable of with standing nominal seat pressure of 10.20 Kg/cm^² (the offered valve shall be as per the requirement of the automation of the system) Class PN 1.0
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make of cast iron double flanged swing check type reflux valve having bye pass arrangement & size one step higher then size of delivery of Pump for withstanding nominal seat pressure of 10.20 Kg/cm^² Class PN 1.0
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of suitable size Cast Iron double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 10.20 Kg/cm^² Class PN 1.0
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to MCB & from MCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L jointless flat water proof cable as per BIS 694-1990 (latest with upto date ammendments) suitable for the pump set offered from MCB to motor, motor to starter including all other electrical equipments such as Thimbles, flexible pipes, solder, nuts & bolts cable glands etc. laid in pipes or trenches. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free ofcost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming toBIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
P/L delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure.
Errection of all equipments from S.Nos. 35 to 41 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-1 Supply of Horizental spindle, horizental split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & platt/Jyoti/Kirloskar/WASP conforming to BIS 1520-1980 (latest with upto date amamendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.
450HP (2 Working, 1 Stand bye).
Discharge (Q) 23.10 LPS for each pump.
Total head in Mts. 256.20 meters
(a) LWL in sump well (h) 538.00 mtrs.
(b) Shaft level 537.50 mtrs.
(c ) Level at discharge point 724.00 mtrs.
(d) Suction lift mtrs.
(e) Residual head 3 mtrs.
(f) Static head 186.50 mtrs.
Rising main
(a) Length 10500 mtrs.
(b) dia 250mm
Pumping hours 8 hours
Altitude of installation above MSL 537 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity (Clear cold water)
(d) Alkalanity
(e) Size of the solids
(f) Other
Supply of suitable soft Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release .
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make actuated cast steel sluice valves having size one step higher then the delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² (the offered valve shall be as per the requirement of the automation of the system)( to IS-1414-API-600, Class ASA-300 )
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make of cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher then size of delivery of Pump for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^² ( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of reputed make of suitable size cast iron flanged sluice valve to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure.
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.Nos. 44 to 51 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-Charian di Dhar:- Supply of Horizental spindle, horizental split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & platt/Jyoti/Kirloskar/WASP conforming to BIS 1520-1980 (latest with upto date amamendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.
(1 Working, 1 Stand bye).
Discharge (Q) 2.51 LPS for each pump.
Total head in Mts. 189.49 meters
(a) LWL in sump well (h) 724.00 mtrs.
(b) Shaft level 723.00 mtrs.
(c ) Level at discharge point 850.00 mtrs.
(d) Suction lift mtrs.
(e) Residual head 3 mtrs.
(f) Static head 127.00 mtrs.
Rising main
(a) Length 2910 mtrs.
(b) dia 65mm
Pumping hours 8 hours
Altitude of installation above MSL 724 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity (Clear cold water)
(d) Alkalanity
(e) Size of the solids
(f) Other
Supply of suitable soft Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release .
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make actuated cast steel sluice valves having size one step higher then the delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² (the offered valve shall be as per the requirement of the automation of the system)( to IS-1414-API-600, Class ASA-300 )
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make of cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher then size of delivery of Pump for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved makeof reputed make of suitable size cast iron flanged sluice valve to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
P/L suitable size copper pVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) - 1988 or latest with upto date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phase) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipe or trenches under floor. The type size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure .
supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.Nos. 53 to 60 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage Barin Mandir:- Supply of Horizental spindle, horizental split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & platt/Jyoti/Kirloskar/WASP conforming to BIS 1520-1980 (latest with upto date amamendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.
(1 Working, 1 Stand bye).
Discharge (Q) 7.20 LPS for each pump.
Total head in Mts. 196.74 meters
(a) LWL in sump well (h) 1037.00 mtrs.
(b) Shaft level 1036.50 mtrs.
(c ) Level at discharge point 1168.00 mtrs.
(d) Suction lift mtrs.
(e) Residual head 3 mtrs.
(f) Static head 131.50 mtrs.
Rising main
(a) Length 3500 mtrs.
(b) dia 100mm
Pumping hours 8 hours
Altitude of installation above MSL 1037.00 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity (Clear cold water)
(d) Alkalanity
(e) Size of the solids
(f) Other
Supply of suitable soft Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release .
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make actuated cast steel sluice valves having size one step higher then the delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² (the offered valve shall be as per the requirement of the automation of the system)( to IS-1414-API-600, Class ASA-300 )
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make of cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher then size of delivery of Pump for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved makeof reputed make of suitable size cast iron flanged sluice valve to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure .
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.Nos. 62 to 69 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-Jandroo:- Supply of Horizental spindle, horizental split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & platt/Jyoti/Kirloskar/WASP conforming to BIS 1520-1980 (latest with upto date amamendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.
(1 Working, 1 Stand bye).
Discharge (Q) 2.05 LPS for each pump.
Total head in Mts. 251.94 meters
(a) LWL in sump well (h) 724.00 mtrs.
(b) Shaft level 723.00 mtrs.
(c ) Level at discharge point 870.00 mtrs.
(d) Suction lift mtrs.
(e) Residual head 3 mtrs.
(f) Static head 147.00 mtrs.
Rising main
(a) Length 2000 mtrs.
(b) dia 50mm
Pumping hours 8 hours
Altitude of installation above MSL 724 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity (Clear cold water)
(d) Alkalanity
(e) Size of the solids
(f) Other
Supply of suitable soft Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release .
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make actuated cast steel sluice valves having size one step higher then the delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² (the offered valve shall be as per the requirement of the automation of the system)( to IS-1414-API-600, Class ASA-300 )
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make of cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher then size of delivery of Pump for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved makeof reputed make of suitable size cast iron flanged sluice valve to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure .
supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.Nos. 71 to 78 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-Purli:- Supply of Horizental spindle, horizental split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & platt/Jyoti/Kirloskar/WASP conforming to BIS 1520-1980 (latest with upto date amamendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.
(1 Working, 1 Stand bye).
Discharge (Q) 15.45 LPS for each pump.
Total head in Mts. 298.43 meters
(a) LWL in sump well (h) 724.00 mtrs.
(b) Shaft level 723.00 mtrs.
(c ) Level at discharge point 980.00 mtrs.
(d) Suction lift mtrs.
(e) Residual head 3 mtrs.
(f) Static head 257.00 mtrs.
Rising main
(a) Length 3850 mtrs.
(b) dia 150mm
Pumping hours 8 hours
Altitude of installation above MSL 724 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity (Clear cold water)
(d) Alkalanity
(e) Size of the solids
(f) Other
Supply of suitable soft Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release .
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make actuated cast steel sluice valves having size one step higher then the delivery of pump and capable of with standing nominal seat pressure of 52 Kg/cm^² (the offered valve shall be as per the requirement of the automation of the system)( to IS-1414-API-600, Class ASA-300 )
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make of cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher then size of delivery of Pump for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 52 Kg/cm^²( to BS-1868-API-600 Class ASA-300)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved makeof reputed make of suitable size cast iron flanged sluice valve to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure .
supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.Nos.80 to 87 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-2 Uhal Supply of Horizental spindle, horizental split casing Single/Multistage centrifugal pumps of standard make such as KSB/Mather & platt/Jyoti/Kirloskar/WASP conforming to BIS 1520-1980 (latest with upto date amamendments) read with BIS 9137-1978 or latest to handle clear water having turbidity 50 ppm. with impellers, casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirloskar/NGEF/Crompton/Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.
(2 Working, 1 Stand bye).
Discharge (Q) 18.16 LPS for each pump.
Total head in Mts. 410.91 meters
(a) LWL in sump well (h) 724.00 mtrs.
(b) Shaft level 723.00 mtrs.
(c ) Level at discharge point 724.00 mtrs.
(d) Suction lift mtrs.
(e) Residual head 3 mtrs.
(f) Static head 372.00 mtrs.
Rising main
(a) Length 9000 mtrs.
(b) dia 250mm
Pumping hours 8 hours
Altitude of installation above MSL 724 mtrs.
Characterstics of water
(a) Temperature 25 degree centigrade
(b) Abient Temp.
( c) Turbidity (Clear cold water)
(d) Alkalanity
(e) Size of the solids
(f) Other
Supply of suitable soft Starter of standard make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release .
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date amamendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/L.T./LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 Phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with upto date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, oprating handed and trip/reset bush button on/off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing no voltage high voltage & overloading & phase voltge difference.
Change over switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable cacpacity.
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make actuated cast steel sluice valves having size one step higher then the delivery of pump and capable of with standing nominal seat pressure of 104 Kg/cm^² (the offered valve shall be as per the requirement of the automation of the system)( to IS-1414-API-600, Class ASA-600 )
Supply of Kirlosker/Sachdeva/RG/Leader or other approved make of cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher then size of delivery of Pump for withstanding nominal seat pressure of 104 Kg/cm^²( to BS-1868-API-600 Class ASA-600)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main for withstanding nominal seat pressure of 104 Kg/cm^²( to BS-1868-API-600 Class ASA-600)
Supply of Kirloskar/Sachdeva/RG/Leader or other approved makeof reputed make of suitable size cast iron flanged sluice valve to IS 780, size equal to dia of suction pipe PN 1 Provided with hand wheel/Cast iron Cap.
Providing laying suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part-I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipes, solder, nuts & bolts, cable gland sets. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, G.I. Pipes, thimbles, nuts & bolts, digging of pits, G.I.wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & erretion of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually, of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.)
Supply of standard make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with upto date ammendments.
Providing/Laying suction, delivery pipe considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of with standing 1.5 times the total pressure .
supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.Nos. 89 to 96 i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Computer Server for Management and Control for Automation system.
Provision and installation of flow measurement devices to be installed at discharge point of the P/Ws, MBR and service storage tank with appropriate sensors along-with the provision with the required data transmission system to central station for analysis with appropriate power backup system.
Supply, delivery, erection and commissioning of following capacity of micro-controller based water disinfection equipment using Silver - Ionization process based on Oligodynamic technology i/c control panel, water chamber, electrode, interconnecting pipe line, field test kit, outer cabinet, voltage stabilizer, water flow meter, booster pump, booster bed pump, etc complete. 100000 LPH with 2 years AMC
R.G. INDUSTRIES
R K ENGINNERS SALES LTD
Swastik Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid