Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Not meeting the NIT conditions |
Tender Value
₹69.6 L
EMD Value
₹1.4 L
Closing Date
8 Oct 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, RpMD(E)
RpG, IGCAR, Kalpakkam
Providing three phase power distribution arrangements in HEF plant area at RpG, IGCAR, Kalpakkam
2024_IGCAR_827273_1
IGC/RPG/ELE/T-53/2024
Open Tender
Electrical Works
Item Rate
180 days
RpG, IGCAR, Kalpakkam
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1.4 L
19 Nov 2024
24 Sept 2024
14 Oct 2024
24 Sept 2024
8 Oct 2024
1 Oct 2024
24 Sept 2024 - 30 Sept 2024
Amount
Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
6-32 Amps DP MCB (Type-C)
40-63Amps, FP MCB (TYPE-C)
Supply fixing testing and commissioning of the following RCCBs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
RCCB DP 40A 30mA, TYPE AC
Supply and installation of the following sizes of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8)
8SWG copper wire
Supply, fabrication and installation of the following size of Copper Flats in Built in trenches on walls, poles, RCC Concrete and through embedded pipes as per the detailed specification. (Refer Sec VI, Clause No.12.7).
25X3 mm Copper flat
Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
3/3.5/4core X Upto 25 sqmm
3/3.5/4Core X above 25 & up to 120 sqmm
3/3.5/4Core X above 120 & up to 240 sqmm
3/3.5/4Core X above 240 & up to 400 sqmm
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
4 Core X10sqmm
4 Core X 16 Sqmm
3.5/4 C x 35 sq.mm
3.5/4C x 50/70 sq.mm
3.5 x 95/120 sq.mm
3.5 x 185 sq.mm
3.5 x 240 sq.mm
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11).
MS fabrication 1 coat primer & 2 coats synthetic enamel paint
Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5)
3/3.5/4 Core upto 25 Sqmm
3/3.5/4 Core Above 25 & Upto 120 Sqmm
3/3.5/4 Core Above 120 & Upto 240 Sqmm
3/3.5/4 Core Above 240 & Upto 400 Sqmm
Maintenance of Motor Control centres/Distribution Centres, LT panels/TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2).
Cubicle switch boards having number of vertical sections up to 3
Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28).
Removal of end termination of armoured cables of following sizes from electrical equipment or reconnecting of removed termination
Sizes upto 4C X 25 sq.mm
Sizes above 4C X 25 sq.mm and upto 4C X 70 sq.mm
Supply and open installation of following Sizes of MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10).
300(W)X300(H)X120(D)mm,1.8mm thick sheet MS Box
Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)
Supply, Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade following sizes of cables in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification.(Refer Sec VI, Clause No.3)
4C X16 sqmm 1.1kV grade Aluminium conductor HRPVC insulation flat wire armour FRLSH PVC outersheath
4C X 35 sqmm 1.1kV grade Aluminium conductor HRPVC insulation flat wire armour FRLSH PVC outersheath
Providing and fixing double Tubular scaffolding system using H-Frames/APS system or (cup lock type) on the interior / exterior side of the building up to the required height made with 40mm dia M.S tube 1.5m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S tubes, M.s tube challis, M.S clamps and M.s staircase system in the scaffolding for working platform etc. as per the technical specification (Refer Section V)
Supply, installation, testing and commissioning of 16 way, per phase isolation (PPI), TPN DB (Cat No. DBTPI016DD of L&T or equivalent) on MS frame work (MS frame will be measured separately) as per the scope of work. (Refer Sec VI, Clause No.15.2).
Shifting, Installation, assisting in testing & commissioning of MCC Panel board. MCC Panel will be issued free cost by dept. (Refer Section V)
MCC-827(N) at 0.0 m elevation in HEF
MCC-830(N) at 0.0 m elevation in HEF
MCC-829(N) at 4.75 m elevation in HEF
MCC-831(E) at 4.75 m elevation in HEF
MCC-830(E) at 11.15 m elevation in HEF
MCC-829(E) at 11.15 m elevation in HEF
Supply, installation, testing, commissioning of coustom made starters in sheet steel enclosure as per the drawing & technical specification. (Refer Section V)
55kW three phase star delta starter
30kW three phase star delta starter
Supply, installation, testing, commissioning of 415V panels as per the SLD & technical specification. (Refer Section V)
PDP - HEF First floor(FF) (DRG NO: DFRP/ELE/PDP-HEF
EPDP - HEF First floor(FF) (DRG NO: DFRP/ELE/PDP (E)-HEF)
Supply and installation of hot dip galvanized GI cable tray as per the technical specification (Refer Section V)
450mmx100mmx2.0mm thick ladder type tray
150mmx100mmx1.5mm thick perforated type tray
Supply and installation of hot dip galvanized GI cable tray cover as per the technical specification (Refer Section V)
450mmx15mmx1.5mm thick cover
150mmx15mmx1.5mm thick cover
Modification of existing TPN DB and fixing as per the technical specification (Refer Section V)
Cleaning of GI/FRP cable trays installed in trenches/wall, removing of dirt, unwanted materials from cable tray as per the technical specification (Refer Section V)
Cutting, removal and shifting of MS angles / channels etc. including chipping of brick wall for removal of the MS item as per the technical specification (Refer Section V)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .