Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 18 FIRST FLOOR FIEE COMPLEX OKHLA INDUSTRIAL AREA PHASE II NEW DELHI | Admitted-Finance |
| 2 | Rejected-Technical 2ND ROSHAN TOWER S B SHOP BISTUPUR AREA EAST SINGHBHUM JHARKHAND | BISTUPUR | EAST SINGHBHUM | JHARKHAND | 831001 | Rejected-Technical As per approval |
Tender Value
Refer Docs
Closing Date
10 Nov 2021, 3:00 pmClosed
AS PER CA
Western Region Head QuartersII ,Nava RAIPUR 492018
Supply and Installation 400 kV Switchyard Uprating Pkg
2021_NTPC_52384_1
NTPC/USSC-CPG1/9900223291
Open Tender
Miscellaneous Works
Works
420 days
Western Region Head QuartersII, Nava RAIPUR 492018
As per tender documents
6 documents required · 6 mandatory
₹2,250
Exempted
31 Mar 2022
2 Aug 2021
16 Nov 2021
2 Aug 2021
10 Nov 2021
2 Aug 2021
2 Aug 2021 - 13 Aug 2021
Supply of Main Equpt.
400KV Circuit Breaker With CR
400KV Circuit Breaker Wo CR
400KV Isolator With 1ES
400KV Isolator With 2ES
400KV Current Transformer
Wave Trap 0.5mH
Wave Trap 1mH
Bus Post Insulator
Supply of Misc Items
TC for CB IPS
TC for ISOLATOR IPS-R
TC for ISOLATOR IPS-E
TC for ISOLATOR Moose
TC for CT IPS-R
TC for CT IPS-E
TC for CT Moose
Interconnector
TC for CB Moose
T-Connector Moose
TC BPI-IPS-R
TC BPI-IPS-Sleeve
TC BPI-Moose-RS
Welding Sleeve
PG Clamp-Moose
Pad Type Clamp-75X12
Pad Type Clamp-50X6
Corona Bell
Grounding Conductor 75X12
Grounding Conductor 50X6
Grounding Conductor 40mm 3000m
Grounding Conductor Treated Pipe
Cleat type clamps for / 75 x 12 mm G.S.
GI Pipe 50 mm dia.
GI Pipe 100 mm dia.
GI Pipe200 mm dia.
GI Pipe 300 mm dia.
Galvanised Ladder Tray 100 mm wide
Galvanised Ladder Tray300 mm wide
ACSR Moose conductor (mtrs.)
40 mm dia. M.S. rod for grounding (Mts)
Buried Cable trench 300 mm wide (m)
Supply of Structural Steel
400KV HCB Pipe Support Structure
400KV BPI Pipe Support Structure
400KV CT Lattice Type Strucutre
400KV Wave Trap Lattice Type Strucuture
Supply of Mandatory Spares and Mntc Eqp
Relays & Misc- For CB
Set gaskets, rings & seals - for CB
Molecular filter for Circuit breaker- fo
Tripping and closing coil (each type) (
Density monitoring system for ckt. Bkr.
Pnematic mechanism- Motor for Compressor
Pnematic mechanismPressure Switch & valv
Spring type- Motor with Gears
Spring type- Limit Switch
Hydraulic type- Motor with gears
Hydraulic type- Limit Switch
Fixed Contact- 3150 A
Terminal connector
Circuit Breaker One Complete Pole (3150
HCB One complete pole (3150A)
Copper contact fingers for female contac
Relays, Power contactors for HCB
Limit Switch & Aux. swicth for HCB
Terminal connectors for HCB
Rotary Bearing for HCB
CT 3000 A - 120% extended rating
SF6 Gas filling and evacuating plant (po
SF6 Gas Leak Detector for CB
SF6 Gas recycling and purifying plant (3
Operation Analyser with DCRM kit for CB
400KV CB Type Test Charges
Dielectric Test
Radio Interference Voltage test.
Temparature Rise test.
Short time withstand current and peak wi
Mechanical endurance and environment tes
Short circuit test duties
Short-line fault test
Out-of-phase making and breaking test
Line charging current duty
Test for reactor switching duty
Corona test.
IP:55 test on each type of box
Seismic withstand test with structure
Thermal test on pre-insertion resistors
Installation Works
400KV Circuit Breaker With CR
400KV Circuit Breaker Wo CR
400KV Isolator With 1ES
400KV Isolator With 2ES
400KV Current Transformer
Wave Trap 0.5mH
Wave Trap 1mH
Bus Post Insulator
TC for CB IPS
TC for ISOLATOR IPS-R
TC for ISOLATOR IPS-E
TC for ISOLATOR Moose
TC for CT IPS-R
TC for CT IPS-E
TC for CT Moose
Interconnector
TC for CB Moose
T-Connector Moose
TC BPI-IPS-R
TC BPI-IPS-Sleeve
TC BPI-Moose-RS
Welding Sleeve
PG Clamp-Moose
Pad Type Clamp-75X12
Pad Type Clamp-50X6
Corona Bell
Grounding Conductor 75X12
Grounding Conductor 50X6
Grounding Conductor 40mm 3000m
Grounding Conductor Treated Pipe
Cleat type clamps for / 75 x 12 mm G.S.
GI Pipe 50 mm dia.
GI Pipe 100 mm dia.
GI Pipe 200 mm dia.
GI Pipe 300 mm dia.
Galvanised Ladder Tray 100 mm wide
Galvanised Ladder Tray300 mm wide
ACSR Moose conductor (mtrs.)
40 mm dia. M.S. rod for grounding (Mts)
Buried Cable trench 300 mm wide (m)
Dismantling of Main Equipment
Dismantling of Eqpt. Structure
Dismantling of existing twin moose
Transportation/Storage of Scraps
Modification/Reconstruction of Support
Erection of HCB Pipe Support Structure
Erection of BPI Pipe Support Structure
Erection of CT Lattice Structure
Erection of Wave trap Lattice Structure
Civil Works
Design and Const Circuit Breaker
Design and Const HCB
Design and Const Current Trafo
Design and Const Wave Trap
Design and Const BPI
Removal and Respread Gravel
Dismantling of Foundation
Modification/Reconstruction of Foundatio
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .