| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.5 L+₹4.9 L (25.0%)Rejected-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L2 | Rejected-AOC L1 being accepted | |
| 3 | L3₹26.7 L+₹7.1 L (36.0%)Rejected-AOC NO 5 3 JJ KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-AOC L1 being accepted |
| Sl No | Description | Qty | Unit | G.L.THIRUMALAI NAIDU AND COMPANY L2 | EVEREST ENGINEERING WORKS L1 | G.JANAKIRAMAN CO L3 |
|---|---|---|---|---|---|---|
| 1.00SCHEDULE 'A' PART-I [ E/M WORKS] | ||||||
| 2.00 | Repair/Maintenance of LT Panel board / APFC panel any type and size by taking shut down,cleaning and removing of carbon particles, replacement of burnt out busbar complete and , tightening of all joints in bus bar, earthing etc and welding of broken doors including replacement of u/s nuts/bolts/washers and replacement of corroded glands, lugs/ thimbles and tightening them properly and testing including painting complete all as directed by engr in charge
Note:- Spare parts for LT / APFC panel will be measured and paid separately as per requirment complete all as directed | 4 | Each Job | 2,760 ₹11,040 | 2,500 ₹10,000 Lowest | 2,950 ₹11,800 |
| 3.00 | Repair/Maintenance and complete servicing of HT VCB’s including disassembling of operating mechanism parts, well cleaning with petrol CTC 226, replacing unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc, oiling and greasing of moving parts, re-assembling, fine setting of mechanism, well cleaning and de-carbonizing of arc control pot, fixed and moving contact including checking testing, tripping check of HT VCB’s making perfect operational in manual and electric mode including maintenance and well cleaning the complete, replacing unserviceable parts and components etc and complete calibration and setting as per fault level of HT VCB’s relay11 KV with suitable instrument including T&P etc complete all as directed.complete all as directed. Note:- Spare parts for VCB will be measured and paid separately as per requirment complete all as directed . | 4 | Each Job | 9,350 ₹37,400 | 6,000 ₹24,000 Lowest | 9,550 ₹38,200 |
| 4.00 | Repair/Maintenance and complete servicing of compact sub station of 630 Amps/21 KA 3 Sec non extensible ring main unit including Dry type transformer 315 KVA Copper Wounded and inbuilded LT penal, checking the servicbility of HT VCB and disassembling of operating mechanism parts, well cleaning with petrol CTC 226, replacing unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc, oiling and greasing of moving parts, re-assembling, fine setting of mechanism, well cleaning and de-carbonizing of arc control pot, fixed and moving contact including checking testing, tripping check of HT VCB’s making perfect operational in manual and electric mode including maintenance and well cleaning the complete, replacing unserviceable parts and components etc complete all as directed.
Note:- Spare parts for CSS/VCB will be measured and paid separately. | 1 | Each Job | 14,750 ₹14,750 | 8,000 ₹8,000 Lowest | 14,500 ₹14,500 |
| 5.00THE FOLLOWING SPARES ARE SUPPLY ONLY FOR ITEM NO 2 to 4 :- | ||||||
| 5.01 | (a) Digital ammeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and directed | 2 | Each | 1,800 ₹3,600 | 1,600 ₹3,200 Lowest | 1,900 ₹3,800 |
| 5.02 | (b ) Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and directed | 2 | Each | 1,840 ₹3,680 | 1,600 ₹3,200 Lowest | 1,700 ₹3,400 |
| 5.03 | (c) Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring and volts complete all as specified and directed | 6 | Each | 250 ₹1,500 | 85 ₹510 Lowest | 275 ₹1,650 |
| 5.04 | (d) LT RG tape wounded current transformer up to 200/5, 10 VA with suitable connection and testing complete all as specified and directed. | 2 | Each | 1,525 ₹3,050 | 1,250 ₹2,500 Lowest | 1,538 ₹3,076 |
| 5.05 | (e) LT RG tape wounded current transformer up to 250/5, 10 VA with suitable connection and testing complete all as specified and directed | 2 | Each | 285 ₹570 | 180 ₹360 Lowest | 291 ₹582 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
26 Jun 2025, 6:00 pmClosed
CWE(Navy) Chennai
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
82654 REPAIR/REPLACEMENT OF HT/LT INSTALLATIONS INCLUDING SERVICING OF TRANSFORMERS, VCB/RMU, HT CABLES, PANELS ETC UNDER AGE(I) NAVY CHENNAI
2025_MES_711590_1
CWE/NAVY/CHN/82654/E8 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chennai
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I) Navy Chennai
₹50,000
Yes
14 Aug 2025
30 May 2025
28 Jun 2025
30 May 2025
26 Jun 2025
13 Jun 2025
30 May 2025 - 6 Jun 2025
Amount
SCHEDULE 'A' PART-I [ E/M WORKS]
Repair/Maintenance of LT Panel board / APFC panel any type and size by taking shut down,cleaning and removing of carbon particles, replacement of burnt out busbar complete and , tightening of all joints in bus bar, earthing etc and welding of broken doors including replacement of u/s nuts/bolts/washers and replacement of corroded glands, lugs/ thimbles and tightening them properly and testing including painting complete all as directed by engr in charge Note:- Spare parts for LT / APFC panel will be measured and paid separately as per requirment complete all as directed
Repair/Maintenance and complete servicing of HT VCB’s including disassembling of operating mechanism parts, well cleaning with petrol CTC 226, replacing unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc, oiling and greasing of moving parts, re-assembling, fine setting of mechanism, well cleaning and de-carbonizing of arc control pot, fixed and moving contact including checking testing, tripping check of HT VCB’s making perfect operational in manual and electric mode including maintenance and well cleaning the complete, replacing unserviceable parts and components etc and complete calibration and setting as per fault level of HT VCB’s relay11 KV with suitable instrument including T&P etc complete all as directed.complete all as directed. Note:- Spare parts for VCB will be measured and paid separately as per requirment complete all as directed .
Repair/Maintenance and complete servicing of compact sub station of 630 Amps/21 KA 3 Sec non extensible ring main unit including Dry type transformer 315 KVA Copper Wounded and inbuilded LT penal, checking the servicbility of HT VCB and disassembling of operating mechanism parts, well cleaning with petrol CTC 226, replacing unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc, oiling and greasing of moving parts, re-assembling, fine setting of mechanism, well cleaning and de-carbonizing of arc control pot, fixed and moving contact including checking testing, tripping check of HT VCB’s making perfect operational in manual and electric mode including maintenance and well cleaning the complete, replacing unserviceable parts and components etc complete all as directed. Note:- Spare parts for CSS/VCB will be measured and paid separately.
THE FOLLOWING SPARES ARE SUPPLY ONLY FOR ITEM NO 2 to 4 :-
(a) Digital ammeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and directed
(b ) Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and directed
(c) Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring and volts complete all as specified and directed
(d) LT RG tape wounded current transformer up to 200/5, 10 VA with suitable connection and testing complete all as specified and directed.
(e) LT RG tape wounded current transformer up to 250/5, 10 VA with suitable connection and testing complete all as specified and directed
(g) Capacitor bank long life 3 phase 440 volts of capacity 5 KVAr (Resin filled) complete all as specified and directed
(h) Capacitor bank long life 3 phase 440 volts of capacity 10 KVAr (Resin filled)complete all as specified and directed
(j) Capacitor duty contactor for APFC pannel 3 phase 440 v operating coil voltage 240 volts,32 Amps complete all as specified and directed
(k) Spring Bushing for VCB breakar ON and OFF mechanisum in existing VCB panel complete all as specefied and directed.
(l) HRC Fuse of 10 Amps rated capacity suitable for HT VCB Panel complete all as specefied and directed.
(m) Heater suitable for HT VCB Panel complete all as specefied and directed.
(n) Name plate suitable for Incoming and Out going HT VCB Panel complete all as specefied and directed.
Repair/Maintenance and complete servicing of 11 KV HT VCB control panel any size/capacity, well cleaning and de-carbonizing, including checking testing, tripping check of HT VCB’s making perfect operational in manual and electric mode etc complete all as specified and directed.
Supply and fixing 11 KV Epoxy resin cast indoor gun type single phase potential transformer ratio 11 KV/ 3 Accuracy class-0.5 and 3 P, burden-10 A 50 Hz, bill-12/28 and VF-1.2 Cont 1.9 or 8 hrs with PT fuse 3.15 Amp suitable for Existing 11 KV VCB make Crompton 630 Amp.compiete all as directed by engr in charge
M & L for manual scraping of old painted surface and providing spray painting as per existing colour with one coat of synthetic enamelled paint of existing colour on outer surface ofincoming and outgoing of VCB including writing SM No and MES No. on VCB Body, complete all as specified and directed.
Material and labour for Painting of transformer 11KV/433V Indoor/Outdoor type with two coat of synthetic enamel grey paint after cleaning and scraping of old paint, oil, rust etc complete including writing SM Nos with white synthetic enameled paint complete all as per specified as directed by Engineer - in - charge of the 500 KVA to 315 KVA Capacity complete all as specified and directed.
Material and labour for locating under ground cable fault (HT ) within 06 hrs including Sunday or any holiday using cable fault locator machine taking all necessary precautionscomplete all as specified and directed. Note : If fault not located by the contractor within specified time a recovery of an amount of Rs. 2000/- will be recovered per day.
Material and labour for locating under ground cable fault (LT ) within 06 hrs including Sunday or any holiday using cable fault locator machine taking all necessary precautionscomplete all as specified and directed. Note : If fault not located by the contractor within specified time a recovery of an amount of Rs. 2000/- will be recovered per day.
Supply and fix in replacement (GOD )Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 ampsfor HT 11 KV complete all as specified and directed
Dismantling of old and unservicable cross arms and M&L for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces all as soecified, complete all as specified and directed.
Supply of LT Bushing rod with insulator of suitable size for transformer of capacity up to 500 KVA complete all as specified and directed.
Supply & fix only non metel Part- HV bushing complete with packing for transformer of capacity up to 500 KVA and for working pressure 11 KV complete all as specified and directed.
Supply & fix of HT Bushing rod of suitable size for transformer of capacity up to 500 KVA complete all as specified and directed.
Supply & fix only non metel Part- LV insulator complete with packing for transformer of capacity up to 500 KVA and for working pressure 11 KV complete all as specified and directed.
Supply, installation, testing and commissionig Battery bank 24 volt,( 12X2V) , 80AH at 10 Hrs discharge rate, self contained, floor mounted, sheet steel, cabinet with two tiers for housing and including low maint batteries with battery charger unit Make: Exide - Model No. UPST-24V-80Ah - sealed maintenance free VRLA battery, initialy charged complete with all accessaries suitable for DC supply of HT VCB, operated from 415 v, 3 phase, 50 Hz ,AC supply complete all as specified and directed.
Supply and fixing Battery charger unit 24V/10 Amp with display complete with all accessaries suitable for DC supply of HT VCB, operated from 415 v, 3 phase, 50 Hz ,AC supply complete all as specified and directed.
Supply and fixing Vaccum Interruptor , single phase, 11 Kv complete with gas as per existing in system complete all as specified and directed.
Supply and fixing power pack with batter back up suitable for HT VCB 11 KV input voltage 230/110 AC, Output 24/30/48/110/220 V DC , back up 15-20 minutes with LED Indicator complete all as specified and directed.
Supply & fixing in replacement power factor controller relay 8 step 415 Volts, AC,50 Hz to automation to power capacitor including replacement of control wiring as required at site including addition/alteration if required complete all as specified and directed.
M & L for New earthing complete with Copper plate earth electrode 600X600X3mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to 20x3mm copper strip at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete all as specified and directed. Note : Copper strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured and paid separately.
Supply & fixing for Copper strip 20x3 mm on wall with insulaters/batten or recessed or buried in ground all as directed
Material & Labour for Cement concrete in foundation, filling and mass concrete type B2 1:2:4 (40mm graded aggregate). Not exceeding 15 CM in deapth for plinth protaction for path including dismentling of old surface complete all as specified and directed.
Taking down the unserviceable LT cable of any size from trenches/ walls /floor etc complete all as specified and directed (Note: exc measured and paid seperetaly)
Taking down the unserviceable HT cable of any size from trenches/ walls /floor etc complete all as specified and directed (Note: exc measured and paid seperetaly)
Taking out existing LT cable off sizes up to 300 Sqmm 3 to 4 core from duct/wall/floor/trenches and re-laying the same serviceable cable after fault rectification in existing position with supply and fixing connecting materials such as thimbles, lugs, nuts, bolts and washers as required at site complete all as specified and directed.
Supply & laying of LT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 1100 volt cross sectional area 185 Sqmm 3 .5 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Supply & laying of LT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 1100 volts cross sectional area 120 Sqmm 3.5 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Supply & laying of LT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 1100 volts cross sectional area 70 Sqmm 3.5 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Supply & laying of HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 120 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Supply and fix heat shrinkable straight through cable jointing kit for 11 KV grade cable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Taking down the unserviceable Lightning arresters and Supply and fix 11000 volt Lightning arresters expulsion type complete with all fittings, transmission class, dies-charge capacity 65 kilo amp complete all as specified and directed.
Supply and fixing Current Transformer duel core Class - SP10 & Class - I, VA - 15, 11 KV 100/5 Amps resine castingcomplete all as specified and directed by engr in charge .
Supply& fix new breather filled with silicagel of 100 KVA to 500 KVA transrormer including taking down old unserviceable one complete all as specified and as directed.
Supply and filling new silica gel in breather of transformer of various capacities including taking down unserviceable silica gel complete all as specified and directed.
S & F in replacement of danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for HT Panels, 25x20cm size including taking out old unserviceable danger notice plate complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Supply and fix 2 core 2.5 sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting complete all as specified and as directed.
Supply and fix 2 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting complete all as specified and as directed.
Supply & fix aluminium lugs for 50 sqmm to 70 sqmm 3.5 core cable complete all as specefied and as directed.
Supply & fix aluminium lugs for 95 sqmm to 120 sqmm 3.5 core cable complete all as specefied and as directed.
Supply & fix aluminium lugs for 240 sqmm to 300 sqmm 3.5 core cable complete all as specefied and as directed
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed.
Supply and lay High density poly ethylene pipes(HDPE) of PN 10 of size 75 mm or suitable size for laying cables laid in trenches complete all as specified and directed.
Supply and lay High density poly ethylene pipes(HDPE) of PN of size 50mm or suitable size for laying cables laid in trenches complete all as specified and directed.
Disconnecting and dismantling of 11/0.433 KV Transformer capacity up to 250 KVA, after disconnecting of electric supply and earth connections including transportation to work shop, drained out transformer oil, lifting/removing of top cover of transformer & cores with chain pully blocks/crane, cleaning of sludge and washed down with the help of spray of clean oil and re-assembling of transformer with S&F of new gasket set assembly, replacement of nuts, bolts and washers as required, re filling of Transformer oil after centrifuging at satifactory dielectric strength complete after electric connections and testing complete all as specified and as directed.
Disconnecting and dismantling of 11/0.433 KV Transformer capacity up to 400 KVA, after disconnecting of electric supply and earth connections including transportation to work shop, drained out transformer oil, lifting/removing of top cover of transformer & cores with chain pully blocks/crane, cleaning of sludge and washed down with the help of spray of clean oil and re-assembling of transformer with S&F of new gasket set assembly, replacement of nuts, bolts and washers as required, re filling of Transformer oil after centrifuging at satifactory dielectric strength complete after electric connections and testing complete all as specified and as directed.
Dihydration of transformer oil having dielectric strength not less than 40 KV complete including filling /top up of oil (if required) up to getting dielectric strength near 60 KV complete all as specified and as directed. Note: the new transformer oil will be paid seperatly under relevent items
M&L for Filling/top up of new transformer oil having dielectric strength not less than 60 KV complete including centrifuging of oil (if required) up to getting dielectric strength near 60 KV complete all as specified and as directed.
Material and labour super enameled copper winding wire for rewinding of HV side of transformer as per original gauge incuding insulating material such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer complete all as specified and as directed.
Material and labour super enameled copper winding wire for rewinding of LV side of transformer as per original gauge incuding insulating material such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer complete all as specified and as directed.
M&L for reinsulation of existing HV copper coil complete all as specified and as directed.
M&L for reinsulation of existing LV copper coil complete all as specified and as directed.
M&L for replacement of Tap changer of 400 KVA trensformer complete all as specified and as directed.
M&L for Ovan Drying of vernish of core complete for 250 KVA transformer complete all as specified and as directed.
M&L for Ovan Drying of vernish of core complete for 400 KVA transformer complete all as specified and as directed.
G.L.THIRUMALAI NAIDU AND COMPANY (BID ID -3329182)
G.JANAKIRAMAN CO (BID ID -3335640)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .