Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.9 L+₹58,206 (2.74%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹22.5 L+₹1.2 L (5.55%)Rejected-Finance | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹23.1 L+₹1.8 L (8.49%)Rejected-Finance | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹23.2 L+₹1.9 L (9.15%)Rejected-Finance 73 ASHOTOSH NAGAR NEAR KUNDAN GENERAL STORE OPP SARAD TIMBER P O MANAS NAGAR KRISHNA NAGAR LUCKNOW 226023 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226023 | L5 | Rejected-Finance other than lowest |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
28 Mar 2020, 6:00 pmClosed
GE WEST LUCKNOW
11 Sardar Patel marg Lucknow Cantt-02
SPL REPAIR BY REPLACEMENT OF BER STORAGE WATER HEATER CONSTN OF VEHICLE PARKING SHED AT AFT AND CERTAIN REV WORKS UNDER GE WEST LUCKNOW
2020_MES_326682_2
GE/W/LKO/75 OF 2019-2020
Open Tender
Civil Works
Item Rate
120 days
Lucknow
Class E cat a i
8 documents required · 8 mandatory
₹500
Yes
GE WEST LUCKNOW
₹46,600
Yes
24 Jun 2020
11 Mar 2020
30 Mar 2020
11 Mar 2020
28 Mar 2020
16 Mar 2020
11 Mar 2020 - 14 Mar 2020
Amount
Demolition of brick work built in CM including all quions, arches, pillars etc complete all as specified and directed.
M & L for brick work with sub class "B" burnt brick (old size) straight or curved on plan exc 6m mean radius built in CM 1:6 completed all as specified and directed.
Taking down cement plaster or cement lime plastering , any descriptuon from brick wall including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for 15 mm thick rendering in CM 1:4 using on fair faces of brick wall or concrete surfaces finished fair and even complete all as specified and directed at site.
M & L for preparation of new plastered surface of wall and applying two coat of cement based paint complete all as specified and directed.
M & L for cutting grooves in brick wall, 75mm, wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3.complete all as specified.
M & L for Providing cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in leveling course, padding etc complete all as specified and directed.
M & L for PCC (1 :2:4 ) Type B-1 using 20 mm graded stone aggregate as in benching and coving etc.
M & L for provision of roof treatment with polymeric water proofing membrane after taking down existing treatment and removal of waste materils all as given below :- (a) Taking down entire existing water proofing treatment on roof and cleaning the roof slab top all as specified and directed. (b) M & L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof including water proofing compound as per manufacturers instruction and as directed by Engr-in-Charge. (c) Applying a coat of Oil based bituminous primer conforming to IS : 3384-1986 @ 0.25 Iitres/sqm. (d) Applying and laying 3mm thick APP membrane having non oven polyester Matt at core and covered with high quality polymeric asphaltic protected with thermo fusible HMHDPE film on both side and over laps 10cm and 15 cm longitudinal and transverse direction respectively and sealed by flame, sealing all overlap complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar. (e ) M & L for two coats of aliuminium paint over membrane surface all as specified and directed.
M & L for applying a coat of polymer water proofing solution on floor,plaster etc including preparation of surfaces all as specified in manufacturer's instructions and directed.
Supply only Integral water proofing compound confirming to IS-2645-2003 of approved make.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete
S & F in repairs PVC (SWR) Pipes 110mm dia single socketed in any length with rubber ring joints , fixed to walls complete all as specified and direceted.
S & F in repairs 75mm PVC SWR pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
S & F PVC (SWR) bends any radius 110mm dia.
S & F PVC (SWR) bends any radius 75mm dia.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed.
M&L for Cement concrete type C-2 (1:3:6) 40mm graded stone aggraegate in foundations, filling and mass-concrete complete all as specified and as directed.
S & F MS Rolled sections as in stanchions,posts, built up of one beam of tublar/ channel/ hollow/ angle with flange plates, caps, bases, splices, angle brackets, cleats and other connections of Fe 410-W( Gde-E-25 ) quality A complete all as specified and as directed.
S & F MS Rolled sections of tublar/channel/ hollow/ angle as in main and cross beams, rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates of Fe 410-W( Gde-E-25 ) quality A complete all as specified and as directed.
S F 0.50mm thick Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M & L preparation of new steel surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete.
M&L Hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete
M&L 100mm thick Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in floor/ sub base, filling and mass concrete complete all as specified.
M&L for 80mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness with Grey cement and no pigment including 25mm thick sand cushioning complete all as specified and directed.
S & F electric water heater storage type of capacity 50 ltrs to operate on 230 volt AC, vertical type including 4 Nos full threaded fastener of size 100x10 mm with, 2 No washer, water connection with 02 Nos flexible steel hose pipe of size 15 mm, 450 mm lenght & suitable plug top of 16 Amp capacity complete all as specified and directed. Make:- Havells or equivalent in Jaguar/Racold/ Bajaj.
S & F water heater storage type electric BEE five star rated of capacity 25 ltrs to operate on 230 volt AC, vertical type including 4 Nos full threaded fastener of size 100x10 mm with, 2 No washer, water connection with 02 Nos flexible steel hose pipe of size 15 mm, 450 mm lenght & suitable plug top of 16 Amp capacity complete all as specified and directed. Make:- Havells or equivalent in Jaguar/Racold/ Bajaj.
Material and labour for point wiring with (FRLS) Fire retradant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia medium grade with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc with provision of new CI/MS terminal boxes with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retradant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete for the following:- (a) one fan/Geyser point controlled by one switch complete all as specified.(i) switch, fan shall be measured and paid for separately) (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface)
Supply and fixing switch piano, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite, 65X50 mm three terminals complete all as specified.
M&L in repairs for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m below normal GL with the top edge of the plate not less then 1.5 m below the normal GL connected to GI wire 4mm dia protected by 15mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded stone aggregate, coping with (1:3:6) type CI using 20mm graded stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt and earth lead connected to earthing test point testing of earthing complete all as specified and directed by Engr-in-charge. NOTE: Main earthing lead and protection GI pipe from earth electrode to test point up to 7.5 m is to be provided and the cost for the same shall deemed to be included in the above quoted rate.
S&F AURA I paird super bright LED (2X2), 36 W, 5700 K with high efficent light smoothing optics all as per specified and directed
S&F JETA NEO 30 W flood light LED fitting Warm/day cool as required, IP 65 protection with high power COB LED complete with including provn of flexible three core cable Cu 23/0.0076 from ceiling rose to fitting terminal for making connection, fixing the fitting on wall including all necessary fixing accessories complete all as specified and as directed . Make Havells/CG/Philips
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed . Make Havells/HPL/Standard
S & F in replacement two single core PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit complete.(PVC Conduit and accessories shall be deemed to be included in the quoted rate)
S&F MCB single pole 10 to 32 Amp 240 volts 10 KA breaking capacity complete as directed.
S&F angle stop valve of brass of high pressure , screwed for iron pipe of size 15mm bore complete all as specified.
S&F Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors with clips, wall hook caps, plug and making good to disturbed surface complete
S&F Bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete
S&F 3 core PVC insulated cord with 1.5 sqmm stranded copper conductor and earth continuity cable complete all as specified and as directed . Make Havells/Plaza/Grandlay
avadhenterprises
M/S Chandra Mohan and Sons
rajan construction
suniltraders
M/S Reliance Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .