Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Accepted being LI Bidder | |
| 2 | L2₹36.3 L+₹1.3 L (3.72%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹37.0 L+₹2.0 L (5.70%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC L3 | |
| 4 | L4₹37.3 L+₹2.3 L (6.44%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹37.3 L+₹2.3 L (6.59%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
23 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR TO CERTAIN EM WORKS INCLUDING CONNECTED WORKS AT NMRL AMBERNATH
2020_MES_382444_1
GERD/PSN/TOKE/12 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹70,000
Yes
13 Nov 2020
1 Oct 2020
26 Oct 2020
1 Oct 2020
23 Oct 2020
16 Oct 2020
1 Oct 2020 - 14 Oct 2020
60 days
Amount
CIVIL WORKS
Dismantling and taking down gang operated device 22 KV inluding removing of HT connections with safey of HT Cable and removal complete all as specified and directed.
Supply and fix in repairs Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for HT 22KV grade including taking out existing unserviceable insulator complete all as specified and directed.
Material and labour for taking down and overhauling to gang operated air brake switch device upto 400 Amps,22 KV capacity including use of petrolium gelly for smooth functioning of all moving contacts of GOD, replacement of spares during inspection and necessary maintenance and refixing GOD in position complete all as specified and directed. Notes : (a) Spares required to be replaced will be measured and paid separately as 'supply only' items. (b) Contractor will provide all safety tools like HT hand gloves, ladder, rope, safety belt and helmet, Tand P magger, earth tester and other necessary tools required at site.
Supply only male contact/moving contact with blade arcing hornof gang operated AB switch devices suitable for 22 KV.complete all as specified and directed.
Supply only female contact /fix contact jaw arcing horn for gang operated AB switch devices.complete all as specified and directed.
Supply only tinned copper flexible jumper 200 Amps/200 Amps complete all as specified and directed.
Supply only MS jumper carrier.complete all as specified and directed.
Supply only GI pipe, heavy grade, 25 mm dia bore made to shape for gang operating from ground complete all as specified and directed.
Material and labour in repair for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 sqmm,22 KV complete all as specified and directed. Make : M seal, Denson, Capseal.
Material and labour in repair for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 95 sqmm, 22 KV complete all as specified and directed. Make : M seal, Denson, Capseal.
Material and labour in repair for indoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 95 sqmm, 22 KV complete all as specified and directed. . Make : M seal, Denson, Capseal.
Cutting the tree branches which touches the LT/HT OH lines and 2.5 metre away from centre line of HT/LT OH line span not exceeding 45 metres between poles and deposting the tree branches / leaves at 30 metre distance away from site.complete all as specified and directed. Note : Any number of tree branches cut in one span will be measured as one length for payment purpose.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for taking out / laying of HT / LT under ground cable and getting out in hard / dense soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50 metre depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Material and labour for crushed sand cushioning for cable protection in trenches complete all as specified and directed. Note : Only Punned thickness of sand cushioning will be measured and paid.
Supply and laying sub class 'B' bricks old size for cable protection complete all as specified and directed.
Material and labour for GI tube, light grade with and including all fittings complete, fixed to walls, poles, ceiling or laid in trenches for cable protection complete all as specified and directed for the following size of pipe :- NOTE :- (Excavation and earth work where required shall be measured and paid separately. MS Clamps for fixing on wall / pole , etc are included in the qouted unit rate). (a) 80 mm dia bore pipe complete all as specified and directed.
(b) 40 mm dia bore pipe complete all as specified and directed.
On load filteration of transformer oil by contineous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap complete all as specified and directed. Note: Oil samples are to collected from top and bottom of oil tank and test results to be recorded and signed by both the parties for each sample before and after filteration.
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap in transformers of various cap installed in various locations complete all as specified and directed. Make of Transformer oil : Savitha, Mack, Gandhar, Power oil. Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
Supply and fix in repairs breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15 mm / 20 mm / 25 mm dia bore with and including suitable reducers / connectors etc as per site requirement /capacity of transformer complete all as specified and directed. Note : Quoted rate shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
Material and labour in repairs for drop out fuse complete of upto 400 Amps, 22 KV capacity including replacement of worn out nuts, bolts,washers, of suitable size / unserviceabele spares and jumper connections for smooth functioning of the devices complete all as specified and directed. Note : Unserviceable spares and jumpers connections required to be replaced will be measured and paid seprately as "Supply only" items.
Supply only the following items:- (a) Fix top contact/L contact for drop out fuse complete all as specified and directed.
(b) Fix lower contact for drop out fuse complete all as specified and directed.
(c) Post insulators of drop out fuse complete all as specified and directed.
Supply, install, testing and commissioning for 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete , GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS / ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers, all ferrous parts hot dipped galvanised and non ferrous parts heavelly tinned to withstand weather complete all as specified and directed. Make : Jaipuria, Atlas, Pactil, Rashtrya.
Supply and fix in repairs Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with and including copper flexible designed jumper and testing and commissioning complete all as specified and directed. Make : Jaipuria, Atlas, Pactil, Rashtrya.
Material and labour for preperation of old painted steel surface over 10 cm width or girth of HT / LT steel tublar pole / pole structure above ground level / coping including cross arms, channels, Flat iron, Clamps in LT / HT OH line by scraping with wire brush & sand paper and applying one coat of aluminium paint including writing pole numbering complete all as specified and directed for the following pole / pole structure :- a) HT 6 Pole structure 11metre long complete all as specified and directed.
b) HT 4 Pole structure 11 metre long complete all as specified and directed.
c) HT Pole 11 metre long complete all as specified and directed.
d) LT pole 8.5 metre / 9 metre long complete all as specified and directed.
Material and labour for Painting to fencing of electrical sub station including prepration of old steel surfaces over 10 cm in width or girth by scraping with wire brush/ sand paper and applying one coat of aluminium paint complete all as specified and directed.
Material and labour for disconnecting the pole mounted / platform mounted outdoor type Transformer situated at various sub stations 22 KV / 0.433 KV 3 phase under NMRL area of any make and transporting to workshop for repairs / rewinding including dismantling the transformer and accessories, removing insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/ LT coil with existing guage of copper super enamelled wire/ copper strip of existing size, providing new insulation, sleeves for outlet connections including tap changer switch connection on all 3 phase, opening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning, including routine tests i.e. IR value test, High voltage test, Ratio test, Short circuit test and BD value test of oil of the transformer to be carried out at workshop, for 100 KVA to 350 KVA including re-installation, commisioning and testing complete all as specified and directed. Notes : (i) Copper winding wire / strip will be measured and paid separately as 'suply only' items. (ii) Insulating oil for topping up will be measured and paid separately as 'supply only' items (iii) Transportation of transformer for repair and re-installation including connection on HT and LT side, testing and commissioning is deemed to be included in quoted rate.
Supply only super enamelled copper winding wire of various gauges or existing specifications for rewinding of transformers HT coil with insulation including necessary class of insulation complete all as specified and directed.
Supply only DPC copper strip of various gauges or of existing specifications for repair and rewinding of transformers LT coil with insulation including necessary class of insulation complete all as specified and directed.
Material and labour for carrying test for acidity of Transformer oil for various Transformers complete all as specified and directed.
Material and labour for disconnecting the transformer outdoor type from HT / LT system and opening carefully by draining out transformer oil upto HT / LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 KVA to 1000 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load complete all as specified and directed. Note : Spare parts required to be replaced will be measured and paid for separately as "Supply only" items here in after.
Supply only LT bushing with and including brass studs of existing specifications complete all as specified and directed.
Supply only top cover gasket set complete as per existing complete all as specified and directed.
Supply only radiator flanged gasket 6 mm thick as per existing complete all as specified and directed.
Supply only oil level indicator gasket set as per existing complete all as specified and directed.
Supply only HT bushing with and including stud 22 KV as per existing complete all as specified and directed.
Material and labour in repair for disconnecting HT incoming / Out going for servicing, opening, draw out HT Breakers complete from its position and through inspection of complete opearating mechnical system, electrical system of AC/DC and complete mechanical repair of breakers including cleaning, oiling and greasing to all spares, checking by draw out mechanism / arrangement of HT breakers and inspection of isolating contacts, decarburizing the male / female contacts, jaws complete and checking of alignment with spout and setting of contact gaps, replacement of spares. complete all as specified and directed. Note :- (i) Rate for removal of moisture from breaker by using vaccum cleaner and heating arrangement deemed to be included in quoted rate (ii) Major spare parts required to be replaced will be measured and paid for separetly as 'supply only' items here in after, however cost of minor spares required for smooth functioning shall be deemed to be included in item rate.
Supply only control contactor complete all as specified and directed.
Supply only control terminals complete all as specified and directed.
Supply only tripping Coil 30V DC complete all as specified and directed.
Supply only control switches complete all as specified and directed.
Material and labour in repairs for wiring complete using standard copper wire as per approved diagram, MF meter, amp meter, LED indicating lamp and starter switch to existing DG set panel including testing complete including taking out old wiring all as specfied and directed. Note : Contractor will assemble wiring incase of any fauilure to wiring system. Rate for the same to be included in quoted rate.
Material and labour for disconnecting from existing main / taking out from LT panal board for servicing and overhauling LT panel / LT ACB panel of any make 400 Amps to 1200 Amp, 50Hz 415V AC including taking out existing mechanism complete with servicing of operating machnism, testing of triping mechanism complete to make it funtioning smoothly and including replacement of unserviceable spares and fixing in its original postion with all connections and testing complete all as specified and directed. . Note : Spare parts requiredto be replaced shall be measured and paid for separetly as 'supply only' items items here in after.
Supply only main isolating contact (Male and Female) jaw type complete including fixing accessories for 400A-1200A capacity LT ACBs complete all as specified and directed.
Supply only shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB complete all as specified and directed.
Supply only under voltage tripping divice (UVT) 415 volts complete all as specified and directed.
Supply only single phae CTS complete all as specified and directed.
Supply and Fix in repairs LT ACB 4 pole fixed thermal / magnetic setting, 1600 Amp, 415 Volts 50kA complete all as specified and directed. Make- Legrand, Siemens, L& T, Havells, ABB, Schneider.
Supply and Fix in repairs MCCB 4 pole adjustable thermal/magnetic setting, 400 Amp, 415 Volts 35KA complete all as specified and directed. Make- Legrand, Siemens, L& T, Havells, ABB, Schneider..
Supply and Fix in repairs MCCB 4 pole adjustable thermal/magnetic setting, 200 Amp, 415 Volts 35KA complete all as specified and directed. Make- Legrand, Siemens, L& T, Havells, ABB, Schneider..
Supply and Fix in repairs MCCB 4pole, 100 Amps, 25 KA, 415 volts, , adjustable thermal -magnetic release type.complete all as specified and directed. Make- Legrand, Siemens, L& T, Havells, ABB, Schneider..
Supply and Fix in repairs MCCB 3 pole, 415 volts, termal magnetic adjustable type, 63 amps.complete all as specified and directed. Make- Legrand, Siemens, L& T, Havells, ABB, Schneider..
Supply, laying, testing and commissioning in repairs of LT underground cable, XLPE insulated armoured and PVC sheathed, 1100 volts grade with and including aluminium conductor multistranded includidng cable connection lugs, glands jointing material etc. laid in trenches / floors / ducts and fixing with and including fixing clamps on pole / wall complete all as specified and directed of following size cable ;- Note :- (a) Excavation and Earth work, brick protection sand cushioning shall be measured and paid for separately (b) Make of cable : Havells, Gloster, Universal, CCI, Polycab. a) 120 Sqnn 3.5 core cable complete.
(b) 95 Sqmm 3.5 core cable complete.
(c) 50 Sqmm 3.5 core complete.
(d) 16 Sq mm 4 core complete.
Material and labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundations of stays and poles, copping of poles etc including necessary form work, finishing exposed surfaces complete all as specified and directed.
Material and labour in repairs for Electrical Earthing with GI plate electrode of size 60 cm X 60 cm X 6 mm thick, burried directly in ground vertically ,erath pit not less than 2.25 metre deep below normal ground level with the top edge of the earth plate at a depth not less 1.5 metre below normal ground level connected to GI strip earth lead of size 32 mm x 6 mm strip by means of bolts, nuts,washers made of galvanised iron and connected to main control board /switch gear/ pannel boards coved with 40 mm dia bore GI pipe light grade all as specified and shown in Electrical plate No-3 of MES Schedule (SSR-2009) Part-I including necessery excavation and earth work in hard / dense soil, charcoal dust, salt and PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate in chamber, RCC 1:2:4 type, B1 using 20 mm graded crushed stone aggregate in cover slab 40mm thick with and including 6 mm dia mild steel bars at 100 mm center to center both ways and 6mm dia mild steel hook complete, 20 mm dia bore GI pipe for watering with funel & wire mes and testing resistence complete all as specified and directed.
Supply and fix in repairs earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit / pipe fixed to poles or any other indicated situation for loop earthing as required 32 mm x6 mm size galvanised strip complete all as specified and directed.
Supply and fix in repairs street light fitting 60 watt energy saving environmental friendly, long life,exclusive innovative die-cast aluminium IP-65 class protection flood light suitable for Lightning architectural faced and general purpose lighting including necessary fixing on existing Highmast light or any other essential required location complete all as specified and directed. Make : Havells, Crompton Greaves, Philips, Bajaj.
Supply and fix in repairs flood light fitting150 watt energy saving environmental friendly, long life,exclusive innovative die-cast aluminium IP-65 class protection flood light suitable forLightning architectural faced and general purpose lighting including necessary fixing on existing Highmast light or any other essential required location complete all as specified and directed. Make : Havells, Crompton Greaves, Philips, Bajaj.
Supply and fix in repairs of street light bracket made out of 40mm dia medium grade GI pipe of 1.5 metre long bend to shape including single coat of aluminium pait over a coat of zinc chrome primer including preparation new steel surfaces complete all as specified and directed. .
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with and including hinged door and locking arrangement of size 140 mmx140 mmx100mm internal comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in and loop out suitable for single phase street light system including nuts and bolts and connecting up , MS clamp fabricated from 25mmx3mm MS flat iron complete all as specified and directed. Make : Sintex , National or equivalant make as approved by GE.
Material and labour in repairs for 3 single core PVC insulated unsheathed copper conductor cable multistranded 2 x 2.5 sqmm + 1 x 1.5 sqmm passing through in steel pole DB to street light luminaires complete all as specified and directed. NOTE :- 3 run of wire shall be measured as one length
Supply and fixing in repairs Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light, the Sensor (Nature Switch) along with and including suitable Power Contactor, MCB and Support Terminals to be enclosed in pole / wall mountable, enclosure made of rust proof, electric shock proof, termite proof and FR grade special moulding compound (Make ; Sintex SMC Junction box) conforming to IP 54 class protection, the Contactor, MCB and Circuit Wiring suitable enough to take load of 12 kW load equally distributed over 3-phase, contactor Rating : 40 Amps (4-pole), MCB (single-pole) Rating : 40.Amps (3 Nos.), Nature Switch : Make Kakatiya Energy Systems Pvt. Ltd. Hyderabad (ENC Approved), Contactor: Make BCH, L&T, Schneider, Havells, MCB : Make- Hager, Schneider, Legrand, L&T, Havells complete all as specified and directed. Make:SWADEEP – 02EC 12kW3P or equivalant as approved by GE.
Dismantling old unseriveable LT panel from site including removing all incoming and outgoing connections, site clearance, necessary excavation & earth work and taking out all incoming and out going switch gears for reuse complete all as specified and directed.
Supply, installing, testing and commissioning, factory made, LT panel board(CPRI Approved) outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system with necessary insulated bus bar arrangement of 4 strips, dust proof, IP 54 class protection and made out of 2 mm thick stainless steel grade 304 sheet with and including suitable angle iron frame with and including necessary excavation & earth work, hinged doors, front and rear opening and locking arrangement and duly powder coated out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete including bus bar chamber with electrolytic aluminium bus bar suitable for 2000 amps capacity for 3 phase and neutral (all connection inside the panel shall be through aluminium strip) connected duly supported with and including FRP insulators including colour code heat shrinkable insulating sleeves and multifunction meter complete with wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with and including copper conductor multistranded with and including cable end terminaion lugs, size of panel 2400 mm x 2100 mm x 1000 mm complete all as specified and directed. NOTE : All incoming and out going switch gears obtained from taking down against Srl item 73 here in before shall be re used / refixed in the panel and fixing charges is deemed to be included in unit qouted rate. .
Material and labour for cutting 0.5 metre wide of roads / pcc plinth for removal / laying of pipe and making good the disturbed surfaces as per existing specifications complete all as specified and directed. (PCC for making good shall be measured and paid for separately).
Material and labour for PCC 1:2:4 type B-1 by using 20mm graded crushed stone aggregate as in foundations for making good road / foot path / hard standing / drain / plinth protection and finishing exposed surface fair and even without using extra cement complete all as specified and directed.
Material and labour for Routine maintenance of 250 KVA DG Set at Main Power House of Old Tech Area consisting of normal repairs with and including periodical routine maintenance and testing of DG set complete (i.e. Engine, Alternator etc) under GE (I) R&D Pashan including all consumables like cottons, waste cloths, kerosene oil etc., maintenance to be carried out as and when ordered in writing by Engineer-in-Chagre complete all as specified and directed ncluding comprising of the following maintenance works :- (a) Change of engine oil complete all as specified and directed, (b) Check clearance of suction and exhaust valves and adjust if required complete all as specified and directed, (c ) Changing of oil filters, fuel filters, screen filters assy complete all as specified and directed, (d) Changing of water filter elements complete all as specified and directed, (e) Topping up of coolent complete all as specified and directed, (f) Change of Hydraulic governer oil complete all as specified and directed, (g) Tightening of all nuts, bolts complete all as specified and directed, (h) Greasing of all points complete all as specified and directed, (j) Checking of any leaking in fuel and oil lines complete all as specified and directed, (k) Cleaning of fuel tank by taking out the dirts and sludges, cleaning the tank thoroughly complete all as specified and directed, (j) Repair of battery terminal made of brass with necessary brazing to cable - each set of 2 complete all as specified and directed. NOTES : (i) Labour charges for dismantling / taking down and replacement / refixing new parts as and when required is deemed to be included in unit qouted rate, (ii) Spare parts like oil filter, fuel filter, by pass filter including engine oil and engine coolent etc. required to be replaced will be measured and paid separately as 'supply only' items here in after,
All as per item No. 77 here in before but 500 KVA DG Set at Power House, New Tech Area all as specified and directed.
Supply only engine oil for DG sets of any capacity complete all as specified and directed. Make: HP, BP, IP, Castrol.
Supply only premix Ethylene Glycol coolent for Engine Radiator complete all as specified and directed. Make : bosch or equivalent make as approved by GE.
Supply only by pass filter element with 'O' ring for DG Sets of 250 KVA to 500 KVA capacities complete all as specified and directed.
Supply only fuel filter primery and secondary with 'O' ring for DG Sets of 250KVA to 500 KVA capacities complete all as specified and directed.
Supply only oil filter with 'O' ring for DG Sets of 250KVA to 500 KVA capacities complete all as specified and directed.
GRAND SERVICES
Shree Ayyappa Engineering
TIMES HYDRO-ELECTRIC COMPANY
Borole Electricals
shakti engineering and electrical works
SHAILENDRA B TULSANI
R. K. Industrial Fabricators
Neha Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .