Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | ₹12.6 L Quoted ₹12.7 L | L1 | Accepted-AOC Quoted rates of lowest tender found reasonable hence accepted |
| 2 | L2₹13.1 L+₹41,204 (3.24%)Rejected-AOC | ₹13.1 L+₹41,204 (3.24%) | L2 | Rejected-AOC Quoted rates are high hence rejected |
| 3 | L3₹13.5 L+₹75,513 (5.93%)Rejected-AOC | ₹13.5 L+₹75,513 (5.93%) | L3 | Rejected-AOC Quoted rates are high hence rejected |
| 4 | L4₹13.7 L+₹92,164 (7.24%)Rejected-AOC | ₹13.7 L+₹92,164 (7.24%) | L4 | Rejected-AOC Quoted rates are high hence rejected |
| 5 | L5₹13.9 L+₹1.2 L (9.12%)Rejected-AOC | ₹13.9 L+₹1.2 L (9.12%) | L5 | Rejected-AOC Quoted rates are high hence rejected |
Tender Value
Refer Docs
EMD Value
₹23,500
Closing Date
5 Aug 2021, 6:00 pmClosed
Shri Rohan Sonkar, IDSE GE Tawang
GE TAWANG Pin- 900198 C/o 99 APO
REPAIR AND MAINTENANCE OF CENTRAL HEATING SYSTEM, WATER SUPPLY AND DISTRIBUTION PIPE LINE, PUMPS, MOTORS, CLEANING OF TANKS AND OTHER CONNECTED WORKS AT ALG TAWANG AREA UNDER GE TAWANG
2021_MES_458064_1
8431/GE/TWG OF 21-22
Open Tender
Civil Works
Item Rate
180 days
Tawang
As per tender documents
5 documents required · 5 mandatory
₹500
GE Tawang
₹23,500
4 Nov 2021
8 Jul 2021
7 Aug 2021
8 Jul 2021
5 Aug 2021
22 Jul 2021
8 Jul 2021 - 15 Jul 2021
Amount
Excavation in trenches not exceeding 1.5m in width and 1.5m depth for taking out and laying PPR pipes and getting out in hard/dense soil all as specified and directed.
Returning filling including spreading , leveling ,watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated surplus soil not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting points in soil all as specified and directed.
Taking up GI/ PP-R pipe of undermentioned sizes tubing with all accessoreis complete all as specified and directed :-
4(a) 50 mm dia
4(b) 63 mm dia
4(c) 90 mm dia
4(d) 100 mm dia
Material and Labour for 3- layer PP-R Polypropylene random copolymer) pipes of following sizes ISI marked, IS-15801 SDR 7.4 (PN 16) UV stablised and inner antimicrobial and outer UV stabilized fusion welded having thermal stability for hot & cold water supply all PP-R plain brass threaded polypropylene random fitting laid in trenches /walls/cellings or laying in floors incl fitting and fixture complete all as specified and directed :-
9(a) 63 mm outer dia
9(b) 90 mm outer dia
9(c) 110 mm outer dia
Supply, laying and testing of steel water tubes medium grade galvanized ,with all fitting and laid in trenches and floor etc for 50mm bore sizes complete all as specified and as directed
Material and Labour for gun metal globe or gate valves of approved make with iron wheel, complying to relevant IS with latest amendments for 50 mm bore size all as specified and directed. All complete as per Specifications
Material and Labour for cast iron air release valve of size 100 mm outer dia , complying to relevant IS with latest amendments. All complete as specified and directed.
S&F in replacement of PPR gate Valves (brass insert) of under mentioned sizes including cutting and inserting in existing pipe or fixing in new laid pipe with required fittings and fixtures complete all as directed
16(a) 63 mm outer dia
16(b) 90 mm outer dia
16(c) 110 mm outer dia
Material and labour for fixing including jointing and testing of cast iron sluice valves of size as following class PN 1.6 conforming to IS : 14846 flanged ends drilled having brass spindle with cast iron whell at top complete with nuts, bolts, washer complete all as per specified and as directed.
20(a) 80 mm dia
20(b) 100 mm dia
M & L for cleaning of under ground water sump, Sedimantation tank , Raw water tanks by scraping the internal surface with steel wire brushes, pumping out water up to bottom level complete drain out removing silt / debris descaling with solution and applying two coats of lime white wash internally as directed by the Engr - in- charge, cleaning the internal surface of the tanks to the complete satisfaction and as directed by the Engr-in -charge for the capacity 100000 Ltr
M & L for cleaning of over head water sump, Sedimantation tank , Raw water tanks by scraping the internal surface with steel wire brushes, pumping out water up to bottom level complete drain out removing silt / debris descaling with solution and applying two coats of lime white wash internally as directed by the Engr - in- charge, cleaning the internal surface of the tanks to the complete satisfaction and as directed by the Engr-in -charge for the capacity 100000 Ltr
M & L for cleaning of under ground water sump, Sedimantation tank , Raw water tanks by scraping the internal surface with steel wire brushes, pumping out water up to bottom level complete drain out removing silt / debris descaling with solution and applying two coats of lime white wash internally as directed by the Engr - in- charge, cleaning the internal surface of the tanks to the complete satisfaction and as directed by the Engr-in -charge for the capacity 50000 Ltr
Material and labour for replacement of Pressure Gauge 4" dial 0-21 kgs rating all as specified and directed. Make:HD Fire protect ltd.
Material and labour for replacement of Pressure Gauge 8" dial 0-21 kgs rating all as specified and directed. Make:HD Fire protect ltd.
Supply of calcium based, high strength chlorination chemical for disinfectant, in granual form for water treatment in factory sealed non returnable HDPE containers (40 to 50 Kg each) having chlorine concentration level of 70% complete all as specified and as directed.
M&L for cutting existing pipe making connection of PPR distribution branch with PPR main of size 50 to 75 mm bore and inserting Tee conncetion and making fusion joint etc. complete all as directed.
Material and labour for cutting, welding and jointing of existing GI pipe of size 50mm complete all as specified and as directed.Note:-the rate of inclusive required necessary excavation.
S&F in replacement of PPR Unions (brass insert) of under mentioned sizes including cutting and inserting in existing pipe complete all as directed
31(a) 63 mm dia
31(b) 90 mm dia
31(c) 110 mm dia
Laying only old serviceable steel water tubes medium grade galvanized and testing ,with providing all new fitting and laid in trenches and floor etc for following sizes complete all as specified and as directed
35(a) 50 mm bore
Suply and fix PPR elbow of under mentioned sizes including cutting and inserting in existing pipe complete all as directed
37(a) 63 mm dia
37(b) 90 mm dia
37(c) 110 mm dia
Suply and fix PPR TEE of under mentioned sizes including cutting and inserting in existing pipe complete all as directed
41(a) 63 mm dia
41(b) 90 mm dia
41(c) 110 mm dia
M&L for carrying out leak test of outdoor unit heating plant with CO2 gas under constant pressure of 250 psi (17 kg/cm2) after complete transfer of refrigerant gas from the entire system, rectification of leakages including cutting and brazing the refrigeration system wherever required and replacement of copper tubing , flare nuts etc. reneutralising after the pressure holds good for at least 24 hrs vaccumisation charging the system with refrigerant gas , testing and commisioning of heating plant complete all as directed by engineer in charge. NOTE:- (i) Necessary copper pipes , nitrogen gas & welding works are deemed to be included in the quoted rate.(ii) Refrigerant gas R-410A will be measured and paid separately
Supply and charging R-410A refrigerant gas.
M & L for opening unserviceable out door unit of central heating plant , checking the control wiring and identifying the fault & rectifying the same and placing the steel mesh at the cable entry to outdoor unit or at open space of out door unit to stop the entry of any outsider all as specified and directed by engineer in charge. NOTE:- (i) Necessary control cable & soldering works are deemed to be included in the quoted rate.(ii) Power control board (PCB) will be measured and paid separaely
Supply and fixing power control board for out door unit of capacity up to 22 HP
Disconnecting the filter bed from indoor unit and cleaning the air filters , removal of complete dirt deposited inside the filter bed area by spray of scale removing agent and flushing out with air blower and refixing the same in existing position complete and replacing the minor items of the indoor unit which are not in working conditons all as specified and directed.
Supply and replace pendant controller (remote switches) suitable for 1/2/1.5/4 TR capacity split indoor unit including PCB and panel board of remote switch comprising single phase preventer, thermal relay, NO, NC coils etc. complete all as specified and directed.
Supply and replace thermo Cole/ PUF insulation to refrigeration piping.
Dismantling and taking up or down old Unserviceable service cable amd LT UG cable of any size complete all as specified and directed
Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional area :-
53(a) 6 Sqmm 4 Core
53(b) 10 Sqmm 4 Core
53(c) 16 Sqmm 4 Core
M&L for replacing old unserviceable MCCB 4 Pole, 415 V, fixed type, 40 Amps with breaking capacity 16 KA all as specified and directed.
M&L for replacing old unserviceable MCCB 4 Pole, 415 V, fixed type,63 Amps with breaking capacity 16 KA all as specified and directed.
M/S RINCHIN DORJEE CONSTRUCTION
M/S L D CONSTRUCTION
MS TD CONSTRUCTION
M/S KESANG CONSTRUCTION
DEOGRATIES SEMPER AMA ASSOCIATE
M/S YESHI TSERING ENTERPRISES
M/S L G BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .