Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L2₹31.8 L+₹3.3 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Higher side quoted amount | |
| 3 | L3₹36.6 L+₹8.2 L (28.7%)Rejected-Finance S O TSERING ANGCHOK R O THANG PA NULL NURLA LEH LADAKH U T PIN 194106 | LEH | LEH | LADAKH | 194106 | L3 | Rejected-Finance Higher side quoted amount |
Tender Value
₹26.4 L
EMD Value
₹53,000
Closing Date
11 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
HQ CWE Khumbathang Pin 900270 C/o 56 APO
PROVN OF TOILET BLOCKS AT NURLA UNDER AGE (I) NIMU
2023_MES_602886_1
80051/21/E8
Open Tender
Civil Works
Item Rate
180 days
Nimu
Class D, Cat a (i)
8 documents required · 8 mandatory
₹500
AGE (I) Nimu
₹53,000
Yes
7 Oct 2023
12 Jun 2023
12 Jul 2023
12 Jun 2023
11 Jul 2023
27 Jun 2023
Amount
Sch 'A' Part-I B/R work:- Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and n exc 1.5m in depth for foundations, laying of pipes etc and not exceeding 10 Sqm on plan for manhole, laying of cable etc and not exceeding 1.5 meter in depth and getting out in hard/dense soil, complete.
M&L Cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete.
M&L for Precast PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate) block masonry with solid block exc 10cm in width and set as in wall etc in CM 1:6.
M & L 75mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base.
M & L 25mm thick Cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in sub base.
S & F Mild steel hold fasts, wall ties and similar small articles conforming to Fe 290-0 or E 165.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips.
All as per item No 08 here-in-before but of 6 and incl 10mm dia in stirrups, spacers and binders.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.
Form work to sides of roof beams band and similar and soffits of girder, lintle, cantilever shelves including supports flat rough surface of concrete complete all as spd and directed.
Formwork to sides of column, posts for square and rectangular rough finished surface.
M & L RCC Nominal mix type B-1, 1:2:4 (20mm graded crushed stone agg) as in foundations, indl rafts, footing foundation beams, plinth beams bases for columns, etc: basement slabs, under reamed piles and mass concrete.
M & L RCC Nominal mix type B-1, 1:2:4 (20mm graded crushed stone agg) as in Beams, cantilevers, bressummers, lintels over 1.5m span.
M & L RCC Nominal mix type B-1, 1:2:4 (20mm graded crushed stone agg) as in columns, pillars, posts.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beams, tee, angle, channel or flat sections) including distance piece, cleats etc. conforming to Fe 410 W (Gde- E- 250) quality A.
S&F Mild steel screw bolts (machine made) with hexagonal or squareheads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long and dia of neck 5 mm but not exceeding 10mm, complete, all as specified and directed by Engineer-in-Charge.
M&L applying two coats of synthetic enamel painting to new surfaces steel based over a coat of red oxide primer exc. 10cm width/girth including preparation of surfaces including filling with filler where reqd all as specified and directed.
S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws as spd and directed.
All as per item No 19 here-in-before but plain steel sheet.
M & L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in cement mortar and pointed in white or coloured cement to match over and including 15mm thick screed bedding layer in CM 1:6 all as specifed.
S&F glazed ceramic coloured tiles 300x200x 6 to 7mm thick as in vertical surface such as skirting, dado, etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles incl 10mm thick plastering in CM 1:3.
M&L for Rendering 10mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:6) and finished even and smooth without using extra cement.
M & L preparation of new plastered surfaces and applying three coats of white wash on walls.
M&L for Rendering 15mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:4) with WPC and finished even and smooth without using extra cement (Note : WPC will be measured and paid separately).
Supply only WPC.
M&L preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer all as specified.
M&L 2nd class Hardwood Plain, solid, straight chowkats and framed rabeted on the solid, rounded or chamfered, put together with glue pinned at jounts, supplied and fixed.
M & L 2nd class hardwood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats.
S & F Mild steel 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed.
S & F extruded aluminium alloy handles, 150mm size, fabricated type, anodised.
S & F Aluminium alloy, anodised, sliding door bolt 250mm size with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast alumimnium alloy and fixed.
S & F Aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm size of extruded sections and fixed.
S&F 2nd class hardwood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
S & F Butt hinges, medium weight, cold rolled mild steel 75 mm long (ISI Mark), fixed.
S & F extruded aluminium alloy handles, 100mm size, fabricated type, anodised.
S & F Aluminium anodised, barrel tower bolt of extruded section and fixed, 100mm size of extruded sections and fixed.
S & F 3mm thk sheet glass, ordinary quality and glazing with oil putty /wooden beading in squares n exc 0.5 sq. m in each pane
M&L applying two coats of synthetic enamel painting to new surfaces wooden based over a coat of pink primer exc. 10 cm width/girth including preparation of surfaces including filling with filler where reqd all as specified and directed
M & L hard core of broken stone and boulders gauge n exc 60mm deposited spread and level in layers n exc 15cm thick watered and rammed to a true surface.
M&L for PCC type C-2 (1:3:6) (40 mm graded stone agg) 75 mm thick as in plinth protection.
S&F 1000 ltrs capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top, two layers) hoisted and fixed in position complete all as specified.
S & F 25mm dia nipple suitable for water tank.
S & F 25mm bore Unions brass to connect iron to polyethylene and fixed
M &L 15mm bore 3-layer PP-R P o l y p r o p y l e n e random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and a n t i m i c r o b i a l welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
All as per item No 45 here but 20mm bore.
S & F 25mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed.
75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.
M & L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement.
M & L 75mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door.
M & L 75mm dia PVC (SWR) branch piece, single (single Y) equal or unequal
M & L 75mm dia PVC (SWR) bends any radius.
M & L 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.
M & L 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal
M & L 110mm dia PVC (SWR) bends any radius.
M & L 110mm dia PVC (SWR) vent cowl.
M & L 630x450mm Wash basins, Vitreous China (flat back or angle back type) any size, and 32mm dia brass waste fitting including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe.
S & F 32mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.
S &F 15mm dia Pillar taps cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm.
S&F CP single towel rail 600mm long fixed to wall incl brackets complete all as specified.
S&F Vitreous China urinal, bowl type, flat back, size 465 x 355 x 265 mm, white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engineer-in-Charge.
S & F 40mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed.
S&F washdown water closet orissa pattern size 580 x 440 mm white with integral foot rest and trap, including connection to drain and to flushing pipe including making good to floor and flush pipe and joint between flushing pipe and socket of wepan complete all as specified and directed by Engr-in charge.
S&F PVC valveless, syphonic action type, flushing cistern of capacity 10 litre, low level, white, with inlet, ball valve, float and handle including brackets and including 32mm dia PVC flush pipe of required length and making connection including bracket, complete all as specified and directed by Engineer-in-Charge.
S & 15mm Bib taps, cast copper alloy CP with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F 15mm bore stopvalve/ Angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for nions and fixed.
M&L Granite (of Any Type) Tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including griding and polishing type , incl15mm thick sreed bedding layer in CM 1:4 complite all as specified and as directed by Engr-in-charge.
Returning, filling under floor excavated soil including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete.
Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete.
Removing excavated material (soils) to a distance exceeding 50m and not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point, complete.
Removing excavated material (soils) to a distance exceeding 100m and not exceeding 250m and depositing where directed at a level not exceeding 1.5m above the starting point, complete.
Excavation over area n exc not exc 1.5 m in depth and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charg
Excavation over area for Each addittional 1.5 m depth or part thereof in depth beyound the first 1.5 m depth and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charg
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, laid dry as directed , complete all as specified and directed by Engr-in-Charge.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves and similar work not exc.200 mm thick (horizontal or slopping) for fair finished flat surfaces all as specified and as directed.
M&L RCC 1:2:4 type B-1 ( using 20 mm graded crushed stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, complete all as specified and directed by Engr-in-Charge.
Precast reinforced cement concrete, type B-1,1:2:4 (using 20mm graded crushed stone aggreagate)as in manhole cover set in cement mortor 1:4 , complete all as specified and directed by Engr-in-Charge.
M & L for cement concrete type D-2 1:4:8 (using 40mm aggregate) Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in for 110 mm bore pipe all specified.
Rendering 15 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 finished even and smooth without using extra cement and water proofing coumpount.complete all as specified and directed by Engr-in-Charge.
M&L for laying broken brick bat 63mm nominal size in bottom of soakage complete all as specified and directed by Engr-in-Charge.
M&L RCC 1:2:4 type B-1 ( using 20 mm graded crushed stone aggregate ) as in baffle wall complete all as specified and directed by Engr-in-Charge.
Sch 'A' Part-II E/M :- Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm multistranded in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover for one light /fan/bell point/bell point/ exhaust fan controlled by one no, one way 5/6 Amps switch, complete all as specified and directed by Engr-in-Charge.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm multistranded in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover for one socket outlet 5 Amp on independent board, complete all as specified and directed by Engr-in-Charge.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm multistranded in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover for one socket outlet 5 Amp on same board, complete all as specified and directed by Engr-in-Charge.
All as per srl item No 85 here-in-before but with conductor of size 4 sqmm (Nominal area) multistranded for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable, complete all as specified and directed by Engr-in-Charge.
Switch piano, flush type single pole, one way 5 Amp, complete all as specified and directed by Engr-in-Charge.
Switch Socket combination, multipurpose flush type 2 in 1, 3 pin, 5 Amp and 2 pin 5 Amp, complete all as specified and directed by Engr-in-Charge.
Switch Socket combination, multipurpose flush type 2 in 1, 3 pin, 5 and 16 Amp, complete all as specified and directed by Engr-in-Charge.
Socket outlet, multipurpose flush type 2 in 1, 3 pin, 5 Amp and 2 pin 5 Amp, complete all as specified and directed by Engr-in-Charge.
S&F Ceiling rose 65x50mm, 2 to 3 terminal PVC/polycarbonate, isolated body
S&F LED lights fitting 1x 20W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm
S&F sheet metal powder coated versatile double door SPN distribution borad, 8 way suitable for MCB;s fitted with copper bus bar rated 200 Amps, neutral link, earth bar and rail suitable for use on 240 Volt, 50Hz.
Supply and fixing SPN 63 Amp rating 240V, 10KA 'C' curve (MCB) of polessand current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
S&F in repairs to MCB SP 6-32 Amp with 10 KA breaking capacity of 'C' series in distribution noards all as specified and directed.
Supply and fixing LED steet light fitting 35 Walt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant includung thermal management in multiple with IP 65/66 protection complete.
Earthing complete with galvanised steel earth plate electrode of size (600x600x6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below notmal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternale layers of 150 mm thick charcoal and common salt, connected to falvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts washer, check nuts of galvanised iron or steel all as shown in Electrical plate No 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering piep of bore 20 mm dia GI light frade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade using 20 mm grade stone aggreate including from work cement morter including CI Pit cover with frace necessary excavtion and earth in any type of soil including testing on completion for desired result all as specified.
Supply and Lay cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with standed aluminium conducton of size 16 Sq mm 2 core all as per specified and as directed by Engr-in-Charge.
Good quality dry sand cushinoning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule Pt-I (2009). Punned thickness shall be measured and paid, complete all as specified and directed by Engr-in-Charge.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 250mm x 150mm x 40mm complete all as directed.
M &L 25mm bore 3-layer PP-R P o l y p r o p y l e n e random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and a n t i m i c r o b i a l welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
M & L PP-R gate valve (brass insert) for 25mm bore pipe as per requirement of site, complete all as specified and directed.
M & L for drilling, tapping, cast iron / Ductile iron / GI water main in position for branch connection with straight plain brass ferrule of same size for 20mm bore, complete all as specified and directed.
Note :- Earth work for E/M portion shall be measured and paid under respective items of Sch A Part-I (B/R Portion)
M/S LOBZANG NORBOO
M/S Deldan Namgail
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .