Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹3.0 LAccepted-AOC 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | I | Accepted-AOC Being lowest | |
| 2 | II₹3 LRejected-Finance GALI NO 2 H NO 45 2ND FLOOR NANAK VIHAR COLONY LAL KUAN GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201009 | II | Rejected-Finance Refer itemwise comparative statement | |
| 3 | III₹3.0 LRejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | III | Rejected-Finance Refer itemwise comparative statement | |
| 4 | IV₹3.2 LRejected-Finance B 35 DURGA PALACE SAINIK VIHAR DEORI ROAD AGRA UP | IV | Rejected-Finance Refer itemwise comparative statement |
Tender Value
Refer Docs
Closing Date
18 Mar 2021, 9:00 amClosed
GE (WEST) AGRA
GE (WEST) AGRA
JOB WORK REPAIR/REPLACEMENT OF UNSERVICEABLE DBs WITH MCBs OF MD ACCN MAP AND RPC AT AGRA UNDER GE (WEST) AGRA
2021_MES_430249_1
3340/Q/68/E3/2020-21
Limited
Miscellaneous Works
Works
30 days
GE (WEST) AGRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
23 Mar 2021
12 Mar 2021
19 Mar 2021
13 Mar 2021
18 Mar 2021
13 Mar 2021
Amount
Description of work are as under:- (a) Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces. Qty- 69 Each. (b) Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor . Qty-422RM. (c) S&F in replacement of unserviceable MCB DB sheet metal enclosure triple pole and neutral 415 V with 200 Amps standard bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mounting type double door factory fabricate complete without MCB and with encosure blank plates for unused way suitable for 4 way flush in wall complete. Qty-18 Each. (d) Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 12 way with 200 amps rated bus bar 240 volts complete all as specified and directed. Make:- Legrand or equivalent model of make Siemens/ Schneider as approved by GE. Qty-4 Each. (e) Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed. Make:- Legrand or equivalent model of make Siemens/ Schneider as approved by GE. Qty- 25 Each. (g) Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 6 way with 200 amps rated bus bar 240 volts complete all as specified and directed. Make:- Legrand or equivalent model of make Siemens/ Schneider as approved by GE. Qty-10 Each. (h) Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 200 amps rated bus bar 240 volts complete all as specified and directed. Make:- Legrand or equivalent model of make Siemens/ Schneider as approved by GE. Qty-12 Each. (j) S & F MCB, 63 Amps, TPN, 415 volts,10 KA rupturing capacity 'C, series as in repairs, complete all as specified and directed. Qty-18 Each. (k) S & F MCB SPN 40 Amps 240 Volts C, series complete all as specified and directed. Qty-14 Each. (l) S & F MCB/Isolator 6 to 40 Amps SP, 240 Volt C, series complete all as specified and directed. Qty-37 Each (m) M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.Qty-114RM (n) M/L sub main wiring of two single core PVC insulated unsheathed stranded copper conductor cables of size 4 Sqmm, 1100 volts grade drawn through and including 20mm dia PVC concealed conduit of 1.2 mm wall thickness including all fixing accessories, and 2.5sqmm PVC insulated stranded copper conductor cable as earth wire(green colour) connected to earth dolly and making good the disturbed surface complete all as specified and directed. (Phase-Red, Neutral – black in colour of cable) Note:- Both running cables including earth wire shall be measured & paid for as single length. Qty-308RM.
M/s A K Engineering Co
M/s SCHOLASTIC ENTERPRISES
M/s Lord Krishna Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_480366.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .