Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC VILL RATTANPUR PO TEH JOURIAN DISTT JAMMU J K 181202 | JAMMU | JAMMU AND KASHMIR | 181202 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹37.4 L+₹1.0 L (2.78%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-Finance Being other Lowest Tenderer | |
| 3 | L3₹38.1 L+₹1.7 L (4.65%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being other Lowest Tenderer | |
| 4 | L4₹38.6 L+₹2.2 L (5.93%)Rejected-Finance | L4 | Rejected-Finance Being other Lowest Tenderer |
Tender Value
₹46.3 L
EMD Value
₹92,600
Closing Date
11 Oct 2022, 6:00 pmClosed
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8486 REPAIR TO INTERNAL WIRING SUBMAIN WIRING INCLUDING REPLACEMENT OF UNSV LIGHT FITTINGS AT ND MB UNDER GE NW KUNJALI
2022_MES_552805_1
8486/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender document
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹92,600
Yes
24 Jan 2023
19 Sept 2022
13 Oct 2022
22 Sept 2022
11 Oct 2022
27 Sept 2022
19 Sept 2022 - 22 Sept 2022
Amount
M&L in repair point wiring complete with 4 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic conduit pipe with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 4Sq. mm as earth continuity conductor connected to common earth dolly for15 amp switch socket on independant board complete all as specified .
M&L in repair point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly all as specified for :-
One light point controlled by one 5A switch
One Fan point controlled by one 5A switch
One Bell point controlled by one bell push
One 5A flush type switch socket point on same board
One 5A flush type switch socket point on independent board
M&L in repair for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza
M&L in repair for point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including surface MS conduit conduit with Accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes surfacing on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth as earth dolly for:-
One light point controlled by one 5A switch
One fan point controlled by one 5A switch
One 5 pin 5A flush type switch socket point on independent board
M&L in repair for point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including surface Pvc conduit conduit with Accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes surfacing on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth as earth dolly for:-
One light point controlled by one 5A switch
One fan point controlled by one 5A switch
One bell/buzzer point on the same board with other switches or independent with cables1.5 sq.mm. size
One 5 pin 5A flush type switch socket point on same board
One 5 pin 5A flush type switch socket point on independent board
S & F in repairs modular switch 1 way 6A, 1 module all as specified and directed. Make: Anchor/Roma/Legrand.
S & F in repairs modular switch 1 way 16A, 1 module all as specified and directed. Make: Anchor/Roma/Legrand.
S & F in repairs modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed. Make: Anchor/Roma/Legrand.
S & F in repairs modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed. Make: Anchor/Roma/Legrand.
S&F for modular fan step regulator, 120W - 2 modular all assspecified and directed. Make: Anchor/Roma plus/Legrand
S & F in replacement of Switch piano flush type single pole one way ,5/6 Amps complete all as directed.Make: Anchor/Roma plus/Legrand
S & F in replacement of Bell push, 5/6 Amps, 240 volts SP complete all as directed.Make: Anchor/Roma plus/Legrand
Supply and fix switch sockets combination 5 pin 5 Amps flush type 240 Volts AC complete. Make: Anchor/Roma plus/Legrand
Supply and fix in replacement switch socket combination multi purpose 3 pin 15 Amps controlled by one switch flush type 240 Volts AC complete.
S & F in replacement of fan regulator electronic step type socket size and making all necessary connections complete all as directed.
S & F in replacement of bell, DINGDONG type, 6 Amps, 240 volts, SP complete all as directed.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as directed.
S & F in replacement of plug top 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as directed.Make: Anchor/Roma plus/Legrand
S & F in replacement of socket 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as directed Make: Anchor/Roma plus/Legrand
S & F sheet metal enclosure (Industrial type DB) complete including SPN type, two pin & earth plug and socket complete with one MCB SP C Curve type of capacity 20 Amp 10 KA complete all as directed Make: Anchor/Roma plus/Legrand
S & F sheet metal enclosure (Industrial type DB) complete including TPN type, three pin & earth plug and socket complete with one MCB TP C Curve type of capacity 63 Amp 10 KA complete all as directed Make: Anchor/Roma plus/Legrand
S & F in replacement of MCB 0.5 to 4 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408595 or equivalent in Havells/ Anchor including making connection complete all as directed.
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408595 or equivalent in Havells/ Anchor including making connection complete all as directed.
S & F in replacement of MCB 40 to 63 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408596 or equivalent in Havells/ Anchor including making connection complete all as directed.
S & F in replacement of MCB 40 to 63 Amps capacity, C Curve type suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408518 or equivalent in Havells/ Anchor including making connection complete all as directed.
S & F in replacement of MCB 40 to 63 Amps capacity, C Curve type suitable for 240 volts AC supply,TP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408766 or equivalent in Havells/ Anchor including making connection complete all as directed.
S & F in replacement of MCB 40 to 63 Amps capacity, C Curve type suitable for 240 volts AC supply,FP with over load and short circuit protection and rupturing capacity not less than 10 KA make Legrand cat No 408792 or equivalent in Havells/ Anchor including making connection complete all as directed.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 protection surface mounting SPN 16 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB’s and MCB/isolators etc complete all as directed. Make -Legrand cat No 507613 or equivalent in Havells/Anchor (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc shall be included in quoted rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB’s and MCB/isolators etc complete all as directed. Make -Legrand cat No 507611 equivalent in Havells/Anchor (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc shall be included in quoted rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB’s and MCB/isolators etc complete all as directed. Make -Legrand cat No 507610 equivalent in Havells/Anchor (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc shall be included in quoted rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting VTPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB’s and MCB/isolators etc complete all as directed. Make -Legrand cat No 507745 equivalent in Havells/Anchor (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc shall be included in quoted rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting VTPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB’s and MCB/isolators etc complete all as directed. Make -Legrand cat No 507748 equivalent in Havells/Anchor (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc shall be included in quoted rate)
S & F MCCB, 415 volts, four pole of cap 100 Amps, 18 KA, with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as directed. Make - Legrand cat No 420055 equivalent in Havells/Anchor
S & F MCCB, 415 volts, 3 pole of cap 100 Amps, 18 KA, with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as directed. Make - Legrand cat No 420045 equivalent in Havells/Anchor
S & F MCCB, 415 volts, four pole of cap 125 Amps, 25 KA, with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as directed. Make - Legrand cat No 42006 equivalent in Havells/Anchor
S & F MCCB, 415 volts, four pole of cap 125 Amps, 25 KA, with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as directed. Make - Legrand cat No 420046 equivalent in Havells/Anchor
S & F MCCB, 415 volts, four pole of cap 200 Amps, 25 KA, with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as directed. Make - Legrand cat No 4202 18 or equivalent in Havells/HPL
S & F MCCB, 415 volts, four pole of cap 400 Amps, 36 KA, with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as directed. Make - Legrand cat No 422007 or equivalent in Havells/HPL
S & F MCCB, 415 volts, four pole of cap 320 Amps, 36 KA, with fixed Thermal - setting and electronic earth leakage module of suitable size and making connections complete all as directed. Make - Legrand cat No 422006 or equivalent in Havells/HPL
Material and labour in repair for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 6.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified.
Material and labour in repair for Sub main wiring with 2 run of 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 10.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified.
Material and labour in repair for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 4.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified.
M & L in repair for Submain wiring with 04 run 4 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one run PVC insulated & unsheathed multistranded copper conductor 4.0 Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly
M & L for Submain wiring with 04 run 6 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one PVC insulated & unsheathed multistranded copper conductor 6.0 Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly
S & F in repair PVC insulated, PVC sheathed, multistranded copper conductor wire 1.5 Sqmm size, three core complete all as specified. Make : Havells/Plaza/Finolex/Polycab.
S & F in replacement of Rigid non metallic PVC conduit ( ISI marked) medium grade, 20 mm dia size inclusive of MS junction boxes for telephone / TV wiring inclusive of all fittings such as tees, bends, elbow, reducers, bell mouth tube ends etc and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as directed.
Overhauling of ceiling fan any size and make, dismantling parts, properly cleaning/removing old existing winding and rewinding and old grease oil and removing old paint from blades and body including down rods complete. Applying new oil grease, varnishing of winding, cleaning dust, rust and applying one coat white enamel paint over a coat of steel primer, assembling and refixing at site complete all as specified.
Overhauling of Exhaust fans any size and make, dismantling parts properly cleaning/removing old existing grease oil and removing old paint from blades. Applying new oil grease, varnishing of winding, cleaning dust, rust & applying one coat grey enamel paint, assembling and refixing at site complete all as specified.
Overhauling of Air Circulator fans any size and make, dismantling parts properly cleaning/removing old existing grease oil and removing old paint from blades. Applying new oil grease, varnishing of winding, cleaning dust, rust & applying one coat grey enamel paint, assembling and refixing at site complete all as specified.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc shall be incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc shall be incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 4 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc shall be incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc shall be incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc shall be incl in quoted rate and no extra payment will be made for it.
S &F in repair 20 Watt 4 FT LED tube light fitting integrated Batten T5 indooor light decorative alluminiumextruded T5 LED Batten-integrated type. Make- C & S CAT PART NO LTTB4F20WLED/W,OR Equivalent TO Havells,Philips
S &F in repair 10 Watt 2FT LED tube light fitting integrated Batten T5: Nakshatra series indooor light decorative alluminiumextruded T5 LED Batten-integrated type. Make- C & S CAT PART NO LTTB2F10WLED/W ,OR Equivalent TO Havells,Philips
S &F in repair LED highbay light 150 WATT with pressure die cast aluminium housing with mounting bracket or eyebolt having efficacy not less than 100lm/W make- C&SLTEHB150WHPLED/LS/WOR or equivalent in Philips/ CG/ Polycab/Shakti /Bajaj
S &F in repair Ceiling light 36 WATT-2ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser.LED ultra slim panel:CYGNUS SERIES.make- C&S CAT PART NO-LTCRSLM36WATT2X2 or equivalent in Philips/ CG/Shakti /Bajaj
S &F in repair Ceiling light 36 WATT-2ft X 2 ft SURFACE mounted backelite panel,cygnus-cs series surface mounting powder coated with CRCA full glow LED panel:CYGNUS- CS SERIES.make- C&S CAT PART NO-LTCSP36WLED2X2,,OR Equivalent to Philips/ CG/Shakti /Bajaj
S &F in repair Ceiling light 36 WATT-4ft X 1 ft SURFACE mounted backelite panel,cygnus-cs series surface mounting powder coated with CRCA full glow LED panel:CYGNUS- CS SERIES.make- C&S CAT PART NO-LTCRP36WLED1X4,,OR Equivalent to Philips/ CG//Shakti /Bajaj
Supply and fixing of battery powered exit signage , 220-240v, 50Hz having 2w LED, operation hours of 3 hours, operating environmental temp ranging from -5 to 45 degree centigrade. Note: Exit signage can be replaced with other directional signs as per site requirement. Make: ABB/ Philips/ Schneider
Supply and fixing of battery powered surface mounted downlighter , 220-240v, 50Hz having 12x1.5w LED, operation hours of 3 hours, operating environmental temp ranging from -5 to 45 degree centigrade. Make: ABB/ Philips/ Schneider
S &F in repair 50W LED flood light any colour with pressure die cast aluminium housing with mounting bracket or eyebolt having efficacy not less than 90lm/W .make- C&S / Philips/ CG//Shakti /Bajaj
S &F in repair like motion sensors base Ceiling light 36 WATT-2ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser.LED ultra slim panel:
S & F in repairs GOLD SHADED HERITAGE TUMBULAR switch 1 way 6A, all as specified and directed. Make: Anchor/Roma/Legrand/SSK cat no .701
S & F in repairs GOLD SHADED HERITAGE TUMBULAR switch 1 way 16A, all as specified and directed. Make: Anchor/Roma/Legrand/SSK cat no.728
S & F in repairs GOLD SHADED HERITAGE socket, 6A - 2/3 pin combined all as specified and directed. Make: Anchor/Roma/LegrandSSK cat No.707
S & F in repairs GOLD SHADED HERITAGE socket 16A,3 pin, combined all as specified and directed. Make: Anchor/Roma/Legrand/SSK Cat No.726
S &F 18 WATT LED flame proof light fitting IP65 luminaire complete with all acessories and fixing arrangement.make-Sudhir or Equivalent in Crompton/Ajmera
R J ENTERPRISES
SHRI SAI ENTERPRISES
TETRI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .