Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹8.8 L+₹1.0 L (13.3%)Accepted-Finance | L2 | Accepted-Finance Being L2 | |
| 3 | L3₹8.9 L+₹1.1 L (14.0%)Accepted-Finance | L3 | Accepted-Finance Being L3 |
Tender Value
₹8.3 L
EMD Value
₹16,555
Closing Date
12 Mar 2024, 3:00 pmClosed
Executive Engineer
CD APWD KAMORTA
SITCof flood light for playground at luxi teressa under MPLADs scheme
2024_APWD_13766_1
46/NIT/DB/CD/KMT/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Teressa
Please refer tender document
5 documents required · 5 mandatory
₹0
₹16,555
8 Apr 2024
5 Mar 2024
12 Mar 2024
5 Mar 2024
12 Mar 2024
5 Mar 2024
Amount
SITC of SIGMA Ultra Led 100 watts Flood light luminaries with pressure die cast aluminum housing in rectangle shape and toughened glass in the front with IP 66 rating similar to orient cat No: LFSMU-100C mounting on 100mm channel i/c connection etc as reqd
Manufacturing and Erection of flood light pole made out of 100 mm dia “B” class ISI marked GI pipe 6 meter long with earth stud and necessary GI reducer/coupling fixed with 80mm dia “B” class GI pipe 6 mtrs long inserted and welded at a span of 1 meter in 100 mm dia GI pipe along-with 2 nos Ms channel 2.0 mtr log fixed with necessary clamping arrangement /welding on top of 80 mm dia GI pipe for fixing of 200 Watt flood light in sequence as reqd to site condition . The bottom of pipe to be welded with 300 mm x 300mm x 6mm thick Ms base plate and foundation to done with cement concrete with painting of one coat of metallic primer and 2 coats of synthetic enamel paint (Silver) fixing of SMC box of 200 x 140 x 95mm (inside) the cement concrete to house 4 pole connector & 4 pole 40 amps MCB four pole with clamping arrangement for SMC box etc as reqd
Erection of metallic pole of following length in cement concrete 1:3:6 (1Cement: 3 Coarse sand, 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refilling etc as reqd.
above 8.0 meter and upto 11.0 meter
Supplying of following sizes of XLPE insulated heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to Is 7098 (Part-I) 1988 as applicable make : Havells or equivalent.
a) 4 core x 10 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/DWC pipe as reqd upto 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required
63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing earthing with safe earthing electrode of galvanization of 80 to 100 microns length 2000 mm outer dia 50 mm inner dia 19mm inner space be filled with crystalline conductive mixture including filling up with electrode (back fill compound ) as reqd for safe earth electrode and providing masonry enclosure with cover plate having locking arrangement etc as reqd.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
SITC of out door type floor mounted cubical Panel board non extendable type LT of size 2.00m x 0.6 m x 0.4 3 phase 440 V 100 A with both side open i/c front double hang shutter with locking arrangement made with 2 mm thick CRCA sheet, MS Angle, MS flat etc in different compartments to accommodate various size of switch gears and accessories as stated under etc i/c interconnection with suitable rating copper cable. The Panel should have inner earthing with 1 coat of primer & 2coat of finishing water proof paint (Silver), fixing of danger plate & PCC work etc as required. 100 amps MCCB, 25 KA breaking load -01 No 40 amps MCCB , 25 KA braking load-03 nos 100 Amps cut out -03 Nos C.T coil 100 /5A -03 Nos Copper bus bar 35 x 5mm -04 Nos. Indicator lamp RYB 01 set Interconnector with 10 sq. mm PVC insulated copper conductor cable =01 Job
Govinda Swamy Construction
M/s G K Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .