Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹49.9 L+₹1.6 L (3.38%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹51.3 L+₹3.0 L (6.30%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹51.4 L+₹3.0 L (6.30%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹52.6 L+₹4.3 L (8.81%)Rejected-Finance H NO 374 1 BUILDING I AQUEM PLAZA TF F4 OPP DEVKI STEEL AQUEM BAXIO MARGAO GOA 403707 | MARGAO | SOUTH GOA | GOA | 403707 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
6 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8451/22/E8
2022_MES_518666_1
8451/22/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class D Category d v
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹98,000
Yes
13 Jul 2022
18 Apr 2022
9 May 2022
18 Apr 2022
6 May 2022
30 Apr 2022
19 Apr 2022 - 30 Apr 2022
60 days
Amount
Checking and attending electrical complaints for continuous electric supply like No light / Short circuit / non working fittings / fixtures / post top lantern / bollard lights and replacement of unserviceable parts such as switch, socket, fan regulator, MCB, holders, tube light, bulk head, ceiling fitting any type including carrying out the minor repair like fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including Sunday and Holiday.
Checking and attending electrical ceiling fan/ exhaust fan complaint including replacement of UNSV ceiling fan condensor of any capacity complete on all working days including Sunday and Holiday.
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable switch, socket, plug top, burnt copper wire connections wherever required complete all as specified and directed by Engineer-in-Charge. under AOR of AGE E/M-II. Note for item No 1,2, & 3 of BOQ:- (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor (d) Any nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor.
(e) Contractor shall be penalised @ Rs. 2000/- per day, if he fails to attend the complaint within 12 hours. (f) All ser numbered complaint docket will be provided by contractor and cost of docket included in these items of BOQ. (g) All T&P,safety gears shall be provided by contractor .(h) Rep of the contractor shall receive complaints in morning 0900 hr and give feedback on daily basis to concern JE E/M (j) payment to contractor released after submission of these complaints duly rectified within time and duly signed by contractor, JE, and Engr-in-Charge in RAR/Final bill. (l) Contractor shall maintain the maintinance register showing all daily complaints recieved and shall maintain job cards for attending complaints.The signature of the user shall be obtained on the job card showing the materil incorporated in the work after completion of the job with date.
Supply only switch piano flush button type single pole one way 6 Amps 230 V complete all as specified and directed by Engineer in charge.
Supply only switch piano 6 amp SP two way 230 V complete all as specified and directed by Engineer in charge.
Supply only Swtich socket combination 2 in 1, 5A 3 Pin and 5A 2 pin combined flush type, 230 V, complete all as specified and directed by Engineer-in-Charge.
Supply only bell push single pole 6 Amps, 230 V complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair switch socket combination 2 in one 3 pin 5 A and 3 pin 15 A Combined flush type.
Supply only switch piano flush button type single pole 16 Amps. 230 V complete all as specified and directed by Engineer-in-Charge.
Supply only socket outlet flush type 2 in 1, 3 pin 6 and 16 Amp single pole, 230 V complete all as specified and directed by Engineer-in-Charge.
Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete all as specified and directed by Engineer-in-Charge.
Hanging /Taking down unsv ceiling fan / exhaust fan of any type / make form site and hand over to JE E/M for deposit to AGE E/M yard for repair / servicing / rewinding etc complete all as directed at site.
Supply only PVC ceiling rose ,surface type, with three terminals complete all as sspecified and directed by Engineer-in-Charge.
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed by Engineer-in-Charge.
Supply only PVC insulated body, angle / Straight lamp holder with back plate complete all as specified and directed by Engineer-in-Charge.
Supply only industrial metal clad plug top, 3 pin, 20 amp complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs LED garden light fitting 11/12 Watt with all accesoriess internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Note:- The rates of the PCC work & including base plate and also including framing/casting of platform for mounting the post top lantern in housing arrengement for erection the base plate.
Supply & Fixing in repairs LED garden bollard light fitting 10 Watt with all accesoriess internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Note:- The rates of the PCC work & including base plate and also including framing/casting of platform for mounting the post top lantern in housing arrengement for erection the base plate.
Supply and fix in repairs LED Tube light fitting 1x18 Watt, with opal diffuser, environmental friendly, energy efficient suitable for MS batten with retrofit T8 polycarbonate one end connection, complete with all accessories and fixing material all as specified and directed by Engineer-in-Charge.
Supply only LED tube light fitting 9/10 watt surface mounted, with extruded polycarbonate, integrated lamp & driver, with opal diffuser and decorative end plates complete with acessories all as specified and directed by Engineer-in-Charge.
Hanging only ceiling fan/ exhaust fan including making connection etc complete all as specified and directed.
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V, 50 Hz, complete all as specified and directed by Engineer-in-Charge.
Supply only MCB Isolator DP 40 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer-in-Charge
Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer-in-Charge.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer-in-Charge.
Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as sspecified and directed by Engineer-in-Charge.
Supply only hylam sheets 3mm thick including cutting for mounting of switches / sockets suitable for sunken box of sizes 4"x4". Make :-As per sample.
Supply only hylam sheets 3mm thick including cutting for mounting of switches / sockets suitable for sunken box of sizes 8"x10". Make :-As per sample.
Supply only hylam sheets 3mm thick including cutting for mounting of switches / sockets / suitable for sunken box of sizes 10"x12" . Make :-As per sample.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed by Engineer-in-Charge.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as sspecified and directed by Engineer-in-Charge.
Supply only hole fastner madeup of MS 10mm dia standard length with nut bolt complete all as specified and directed by Engineer-in-Charge.
Supply only heating element of 1.5/2 KW any type with nut bolt washer complete as per site requirement all as specified and directed by Engineer-in-Charge.
Supply only thermostat for 6"/11" suitable for geysers of capacity 25/50 Ltrs complete all as specified and directed by Engineer-in-Charge.
Supply only PVC connection pipe of 12 mm ((internal) suitable for hot/cold water, 45 cm long with brass nuts and rubber washers complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring complete with FRLS 1100 Volts grade, two runs of 2.5 sqmm copper cable through PVC casing and capping with one run of 2.5 sqmm PVC insulated and unsheathed multistranded copper conductor cable as earth continuity wire connected to common earth dolly complete all as specified and directed
Material & Labour Point wiring for one light/fan point complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches, sockets etc concealed on wall complete all as specified and directed.
Re-jumbering only in street light fittings / flood lights any type and capacity on LT Pole including necessary nut bolts all as directed.
Taking down and refixing after de corbonising and replacement of connection plate etc in repair LED Street light/flood lights up to 72 watts including provision of suitable nut bolts, screws etc for fixing all as directed.
M & L Aluminium conductor, steel reinforced of any size as per site requirement including fixing on LT Pole Insulators, Jumpers etc including dismantling old U/S Conductor.
Attending electrical compliant like ACSR jumpers binding wire old removed and new wire binding or rejumber as required etc.
Supply only PVC isulated multistranded Copper Conductor Cable 1100 V grade 1.5 Sqmm size for day to day repair work.
Repair/replacement of cell, lead plates, damaged battery compartment, terminal post of 12 Volt 180 AH battery and filling with acid and diluted distillited water for desired specific garvity and baterry lead of 1.5 mtr length terminal made out of brass fully charged complete all as directed by Engineer-in-Charge.
Supply and Fix in repairs for louvers of any make up to 300 mm exhaust fan (Aluminium) complete all as specified and as directed by Engineer-in-Charge. Note: Repairs of louvers any story qtr or building.
Supply and Fix in repair Ceiling Fan motor with body complete suitable 1200 mm Sweep Ceiling Fan matching to blade existing location.
Supply and Fix in repair Fan Blade set of three suitable of any make and sweep up to 1200 mm sweep Celing Fan matching to existing location.
Supply and fix in repair of Exhaust fan (Square type) 230V single phase plastic body, sweep size (mm) 250 connecting up including provision of necessary wall opening and connected cement works and cable from ceiling rose or connector to exhaust fan etc complete all as specified and directed. Note: Old exhaust Fan deposited in store
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .