| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹28.3 L+₹4,997 (0.18%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-AOC higher rate |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
31 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE NEW DELHI
CA NO GE/ND50/202223 REPAIR / MAINT OF SUMMER APPLIANCES WINDOW TYPE/SPLIT TYPE/CASSATTE TYPE ACs AND ALLIED SERVICES AT KASHMIR HOUSE UNDER GE NEW DELHI
2022_MES_542933_1
GE/ND-50/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹78,000
Yes
20 Sept 2022
3 Aug 2022
2 Sept 2022
3 Aug 2022
31 Aug 2022
17 Aug 2022
Amount
Labour for checking and attending complaints of ACs, Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed.(any parts required for replacement shall be measured and paid separately under respective items) Notes:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in Kashmir House . (b) The complaint should be attended on same day with in 3 hours . (c)) If the complaint not attended/not completed on same day with in three hours recovery will be done as follows:- (i) For first day Rs.1000/- (ii) For second day Rs.1500/- (iii) For next every day Rs.2000/-
Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC
All as per item No 2 above but Split type AC of any type and 1.5/2 Ton capacity
Servicing of three phase cassette /tower type split AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
Supply only against repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 Volt for AC upto 4.00 Ton .
Supply only in replacement Running capacitor 6 mfd 230 volt
Supply only in replacement Running capacitor 4 mfd 230 volt
Supply & charging gas refrigerant R-22 /410 A/ or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
Supply only in replacement starting relay suitable for 1.5/2 Ton capacity AC
Supply only in replacement over load protector suitable for 1.5 Ton capacity AC
Supply only in replacement thermostat switch suitable for 1.5/2 Ton capacity AC
Supply only against in repair item of starting relay suitable for 4.0 Ton capacity AC complete all as specified.
Supply only against in repair item of over load protector suitable for 4.0 Ton capacity AC complete all as specified.
Supply only against in repair item of thermostat switch suitable for 4.0 Ton capacity AC complete all as specified.
Supply and fixing in replacement reciprocating /Rotary type compressor suitable for 1.5 to 2.0 Ton capacity split type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Supply and fixing in replacement reciprocating/Rotary type compressor suitable for 1.5 to 2 Ton capacity window type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Supply and fixing in replacement any type of compressor suitable for Inverter type 1.5 to 2 Ton capacity split AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
Supply and fixing in replacement of three phase compressor suitable for 3.5 to 4.0 Ton capacity suitable of cassette /tower AC of the same make and model as per existing make of ACs complete all as specified and directed.
Supply only in replacement wiring kit suitable for 1.5/2 Ton capacity AC complete all as specified & directed
Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type Acs
Supply only in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type Acs
Supply only against in repair item of air filter synthetic / nylon type as per existing size and shape suitable for 3.5/4.0 Ton capacity cassette type split AC's complete all as specified.
Supply only in replacement new fan motor (indoor/outdoor) 1/4,1/5 HP single/double shaft as per existing model suitable for Split type ACs 1.5/2 Ton complete all as specified and directed.
Supply only in replacement new DC fan motor (indoor/outdoor) 1/4,1/5 HP single/double shaft as per existing model suitable for Split type ACs 1.5/2 Ton complete all as specified and directed.
Supply only against in repair of fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton AC's of any make/type complete as per requirement on site all as specified.
Supply only against in of new DC fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton cassette type AC's of any make/type complete as per requirement on site all as specified.
M & L for rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enamelled copper winding wire of same gauge including replacement of insulating material, bushes and shaft all as specified & directed
Supply only in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 2.5 sqmm.
Supply only in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 4.0 sqmm.
Supply only in replacement condenser fan blade made out of plastic suitable for upto 2 Ton capacity window type Acs.
Supply only in replacement condenser fan blade made out of plastic suitable for upto 2 Ton capacity split type Acs.
Supply only against in repair of condenser fan blade made out of aluminium suitable for upto 4.0 Ton capacity cassette type split AC's complete all as specified & directed.
Supply only in replacement of evaporating air blower made out of suitable for upto 2 Ton capacity for window type AC all as specified and directed
Supply only in replacement of evaporating air blower made out of suitable for upto 2 Ton capacity for split type AC all as specified and directed
Supply only against in repair of indoor air blower made out of suitable for upto 4.0 Ton capacity type split AC's complete all as specified & directed.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9 mm ("3/8") for refrigerant copper piping of split AC units. Make:- Supreme/Gulf-o-flex/Superlon.
Supply only in replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16 mm ("5/8") for refrigerant copper piping of split AC units. Make:- Supreme/Gulf-o-flex/Superlon.
M & L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape.
M & L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option.(Gas charging shall be paid and measured under respective item)
Supply only copper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for ACs. Make-Mandev/Mandley/ Uniflow
Supply only copper tubing heavy duty inner dia 13mm (1/2") for refrigerant for ACs.
Supply only copper tubing heavy duty inner dia 9 mm (3/8") for refrigerant for ACs.
Supply only copper tubing heavy duty inner dia 16 mm (5/8") for refrigerant for ACs.
Supply only condensing coil suitable for 1.5/2 Ton split type ACs as per existing size/shape and as per existing make.
Supply only evaporating coil suitable for 1.5/2 Ton split type ACs as per existing size/shape and as per existing make.
Supply only brass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make.
Repair to control processing board( Remote control kit) with hand set including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model.
Repair to control processing board( Remote control kit) inverter type with hand set including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 3.5/4 Ton split type ACs of any make & model.
Supply and fixing in replacement split type AC 1.5/2 Ton indoor unit kit with PCB complete with sensor complete with fixing plate suitable to non inverter type AC complete all as specified and directed.
Supply and fixing in replacement split type AC 1.5/2 Ton indoor PCB unit kit complete with sensor complete with fixing plate suitable to inverter type model and make AC all as specified and directed.
Supply and fixing in replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor,condensor coil, condenser fan with blade and sensor suitable to non inverter type existing model and make AC all as specified and directed.
Supply and fixing in replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condenser coil, condenser fan with blade and sensor suitable to inverter type existing model and make AC all as specified and directed. Make:- Carrier/Blue star/ Napolean/Totaline.
Supply and fixing in replacement window AC kit 1.5/2 Ton PCB with sensor complete with condensing coil, fan motor, blower and motor, compressor and grill complete suitable to non inverter type existing model and make AC all as specified and directed. Make:- Carrier/Napolean/Skoda.
Supply only in replacement air direction changer louver motor ( swing motor) suitable for split type ACs as per existing make and model
Supply only in replacement cordless Remote for inverter type ACs Hot & cool suitable for 1.5 Ton AC as per sample.
Supply only in replacement cordless Remote for ACs suitable for 1.5/2 ton split/window AC as per sample.
Servicing of Refrigerators of 165 to 310 ltr capacity single door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement new compressor suitable for 165/310 ltr capacity refrigerator reciprocating type complete all as specified and directed.
Supply and fixing of monkey menace protection device with pvc spikes size as per sample all as specified and directed
Taking down AC of any type, any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repair work, transportation back to location of installation , reinstallation/refixing in position after complete repairs as required and making functional including testing complete all as specified and directed.
supply and fix of drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 TR as per sample all as specified and directed
M&L in replacement Metal Clad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz .
M&L in replacement modular AC board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz
Supply, installing, testing and commissioning in replacement factory made and tested Outdoor type, platform mounted, Phase Sequence Corrector of capacity 63 A , 3 Phase 4 Wire, 415 volts, 50 Hz, platform mounted. The Phase Sequence Corrector shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- Make:- Havells/ Schneider / ABB/ L&T/ Universal Switch Gear Control. Note- Work includes civil work like excavation and preparation of PCC Plinth
The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Certification Short Circuit withstand strength should be 50kArms for 1.0 Sec with initial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
supply only in replacement voltage stabilizer of capacity 3 to 5 KVA ,copper wounded made of metallic steel body complete all as specified and directed
S&F in replacement of plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified.
M&L for taking down Split/Window AC and shifting from one position to other within the premises Complete with copper tubing indoor plate and copper tubing complete with all accessories with making good the disturbed surfaces with cement plaster and POP . Complete all as specified and as directed by Engr-in-Charge
S&F sub main wiring in replacement with two runs PVC insulated unsheathed FRLS stranded copper conductor cable of size4.0 Sqmm along with one run of PVC insulated unsheathed stranded copper conductor cable of size 2.5 sqmm as earth wire connected to earth dolly fixed on surface of wall/ceiling/in concealed PVC conduits complete including cutting chases and making good to walls at disturbed area all as specified and directed. Make of Conduit- Plaza/Kalinga Make Of Cable- RR Kabel/Havells/Polycab Note :- Two run of 4.0 sqmm copper conductor cable,one run of 2.5 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
All as per item No 74 here-in-before but size of cable 2 x6sqmm complete along with cable 1x2.5 sqmm FRLS type for continuous earth wire and connected to common earth dolly complete all as specified. Make-RR / Havells/ polycab Note :- Two run of 4 sqmm copper conductor cable,one run of 2.5 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
Supply only in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 12 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified
Supply only in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified.
Supply only in replacement of MCCB TP/TPN 125 Amp, 25kA thermal type complete all as specified.
Supply only in replacement of MCCB TP/TPN 160 Amp, 25kA thermal type complete all as specified.
Supply only in replacement of MCB SP 40-63 Amp, 10kA all as specified.
Supply & fixed rigid non-metallic 20 mm external dia PVC conduit concealed on surface to wall / ceiling for drain out of water from split type and window type but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks up to outdoor unit to ground floor level all directed by Engr-in-Charge.
supply only in replacement flexible pipe 15/20/25 mm dia white colour complete all as specified and directed
Supply only in replacement of MCB SPN 20-32 Amp, 10kA all as specified.
M & L for making suitable hole in the wall to fix window or split AC and maintain the surface as per existing Note : (a) plastering ,putty ,painting included in the quoted rate .(b) covering the window by ply if necessary also included in the quoted rate
supply only in replacement wall stand /chauki stand to fix outdoor of split/cassette ac made of metallic stell complete all as specified and directed
Supply only in replacement fastener upto 8mm size suitable to fix wall stand /chauki stand complete all as specified and directed
RUCHIKA ENGG.WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .