| 1 | L1₹1.9 CrAccepted-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | ₹1.9 Cr | L1 | Accepted-AOC BEING L1 AND REASONABLE TENDER |
| 2 | L2₹2.0 Cr+₹8.1 L (4.18%)Rejected-Finance | ₹2.0 Cr+₹8.1 L (4.18%) | L2 | Rejected-Finance NOT BEING THE LOWEST |
| 3 | Rejected-Technical HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | - | - | Rejected-Technical Rejected due to NO Slow progress as per WLR QE Sep 2019 of CESWC Jaipur Sl No 50. |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
6 Feb 2020, 6:00 pmClosed
Chief Engineer (Navy) Mumbai
Headquarters Chief Engineer (Navy) Colaba Mumbai 400 005
PROVISION OF COMCEN BUILDING AT INS DWARKA OKHA.
2019_MES_300584_1
87830/E8
Open Tender
Civil Works
Lump-sum
450 days
OKHA
As per Tender Documents
8 documents required · 8 mandatory
₹3,000
Yes
GE (I) (Navy) Porbandar
₹3.0 L
Yes
2 Apr 2020
23 Nov 2019
10 Feb 2020
23 Nov 2019
6 Feb 2020
25 Jan 2020
Amount
SCH 'A' PART-I "BUILDINGS & STRUCTURES" Total of Sch-'A' Part-I B/F to BOQ(Schedule ‘A’) Serial Page No. 28 (R)
SCH 'A' PART- II "SITE CLEARANCE, EXCAVATION & EARTH WORK. Total of Sch "A" Part-II B/F to BOQ at Sl page No 30 (RR)
SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Sch "A" Part-III B/F to BOQ at Sl page No 31
SCH 'A' PART-IV "INTERNAL ELECTRIFICATION" Total of Sch "A" Part-IV B/F to BOQ (Schedule 'A') on Serial Page No 34(R)
SCH 'A' PART-V "ROAD/ PATH / CULVERTS" Total of Sch "A" Part-V B/F to BOQ on Serial Page No 36(R)
SCH 'A' PART-VI "AREA DRINAGE " Total of Sch "A" Part-VI B/F to BOQ on Serial Page No 37
SCH 'A' PART-VII "SEWAGE DISPOSAL" Total of Sch "A" Part-VII B/F to BOQ (Schedule 'A') on Serial Page No 39(R)
SCH 'A' PART-VIII "COMPOUND WALL/FENCING AND GATE" Total of Sch "A" Part-VIII B/F to BOQ (Schedule 'A') on Serial Page No 42(R)
SCH 'A' PART-IX ""LIGHTNING PROTECTION"" Total of Sch "A" Part-IX B/F to BOQ (Schedule 'A') on Serial Page No 43 (R)
SCH 'A' PART-X "EXTERNAL WATER SUPPLY" Total of Sch "A" Part-XI B/F to BOQ (Sch 'A') on Serial Page No 45
SCH 'A' PART-XI "EXTERNAL ELECTRIFICATION" Total of Sch "A" Part-XI B/F to BOQ (Schedule 'A') on Serial Page No 46(R)
SCH 'A' PART-XII "COOLING APPLIANCES" Total of Sch "A" Part-XVI B/F to BOQ (Schedule 'A') on Serial Page No 47
SCH 'A' PART-XIII "DG SET" Total of Sch "A" Part-XVI B/F to BOQ (Schedule 'A') on Serial Page No 48 (R)
SCH 'A' PART- XIV" MISCELLANEOUS ITEMS"
"SUMMER APPLIANCES"
Supply and fixing Voltage Stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 140 Volts to 280 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5% of capacity of 3 KVA. Make :- "VOLINA/V-Guard/Su Kam/Everst.
"AIR CONDITIONING"
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating and EER 3.2 of capacity 1.5 TR complete all as specified and as direced . Make- DAIKIN/BLUE STAR/LG/VOLTAS/SAMSUNG
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating and EER 3.2 of capacity 1.0 TR complete all as specified and as direced . Make- DAIKIN/BLUE STAR/LG/VOLTAS/SAMSUNG
Supply and fixing Voltage Stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 140 Volts to 280 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5% of capacity of 5 KVA. Make :- "VOLINA/V-Guard/Su Kam/Everst.
RO PLANT
Supply and fix Reverse Osmosis Plant 5 stage supreme quality stainless steel of out put capacity of 25 Ltr per hour complete all as specified and as directed.
"TV/Tele/LAN/Conduit"
Supply and fixing rigid non-metallic PVC conduit exclusive of boxes (Junction/terminal) but inclusive of all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hooks etc., of external dia size 25 mm complete all as specified and as directed.
Supply and fix Junction boxes (1 to 4 Way) for 25 mm dia complete all as specified and as directed.
Material and Labour for cast iron/pressed steel terminal boxes 60 mm deep for mounting, switches sockets, fan regulator, etc., with 3 mm thick plastic laminated sheet cover of 75 mm x 75 mm square complete all as specified and as directed.
Supply and fix TV jack mini complete all as specified and directed. Make :- "Anchor Code 33040 or equivalent.
Supply and Fix Tele/LAN Jack mini with shutter complete all as specified and directed. Make :- "Anchor Code 33085 or equivalent.
Supply and fix FRP looping box prewired complete fitted with terminal connector block bakelite 8 Way of 20 Amps Rating with shorting strip copper, fitted with one Nos of MCB SP 06Amps 240 Volts for termination of incoming of incoming and outgoing cables, local connection to fittings complete all as directed
"DG SET"
Supply and install, testing and commissioning of factory made Diesel Engine driven generating set, fully wired alternator AC to given as out put of 40 KVA continously rating at a PF of 0.8 lagging, 415 Volts AC 3 phase 4 wire 50Hz + 1% supply, 1500 RPM directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank of adequate capacity with fuel line and accessories, making PCC foundation work of suitable as per manufacturer"s instructions, variation damper pad and other accessories etc., and comparing of the following:-
(A) Diesel Engine: Water cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3045 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: Kirloskar/Ashok Leyland/Cummins
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator.
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 12 Voltage Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil pressure (iii) Overspeed stop
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:- 12 Volts, 92 AH, 25 Plates maintenance free battery with leads and terminals conforming to IS:14257 (Make- Excide/Amron). (z) Fuel tank: 8 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling from exterior canopy (without opening its panel) etc complete all as specified and directed.
(B) Alternator: Suitable rated 40 KVA,at .08 PF, 415 Volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, excitation, screen protected, drip proof , insulation class-H, IP -23, self ventilated and confirming to BS 5000/IS 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364 (Part-1) Make: Stampford/crompten/kirloskar
(C) Acoustic Enclosure:- M & L for acoustic enclosure for the above 40 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide lines of Central Pollution Control Board and Manufacturer`s specifications from authorised OEMs of Gen Set manufacturer specified including inside illumination by 02 Nos LED Lights all as per CPCB norms complete.
Supply, installation and commissioning of AMF Panels suitable for 40 KVA DG set, indoor type with angle iron pedastal frame, cubical type free standing, working on 415 Volts, 3 Phase 50 Hz, AC supply complete with colour coated bus bars 100 Amps fully compartmentalised, dust and vermin proof, 2 mm thick CRCA sheet, steel enclosure complete inclduing painting as per the 7-tank process, IP-52 protections, as per specifications and having the following details all as shown in single line diagram:-
Cutting the existing road/PCC path of size 0.45 M wide and 0.10 M depth for laying of pipes and making good the disturbed surface of road/path with PCC (1:3:6) type C-1 using 20 mm graded stone aggregate matching with the existing surfaces complete all as specified and as directed.
Supply and Repair/Replacement for 160 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment (Ics=100% of Icu) of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells Cat No :- IHLE1ABF0100# or its equivalent of Legrand/L&T
"INTERNAL ELECTRIFICATION"
S &F modular AC Box (for AC ) sheet metal with socket 3 pin, suitable for 20 Amps flush type universal including 20 amp c series MCB protected.
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make-WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x8/9 Watt ( for mirror light) ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED Security/Street light fittings 15 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED light fittings decorative 36/34 Watt RECESS mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Fabricate,supply & fix GI pipe bracket 2 5mm dia- 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 15w Security light fitting complete all as specified and as directed.
MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ / schneider/ ABB
M & L for MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps complete all as specified and as directed.
M & L for MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified and as directed.
M & L for MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating complete all as specified and as directed.
M & L for MCCB TPN 100 Amps , 415Volts, 25KA ,4 POLE L&T CAT NO-CM91198OOLO/ LEGRAND CAT NO-420055 / / schneider/ ABB complete all as specified and as directed.
M & L for MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98603OOOO /Legrand cat no-420013/schneider cat no-LV510315 omplete all as specified and as directed.
Note:- for item No 20.08 to 20.13 Make of MCCB &MCB - LEGRAND/HEGGER/SCHNEIDER/I7T
S&F Exhaust fan heavy duty of size 225/230 mm sweep metal body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Exhaust fan heavy duty of size 300 mm sweep metal body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. ( for Tech Building & Adm Building ) -Make : Crompton Greaves/ Bajaj/Orient
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5 m long,,PPC pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2009 (Part-I)
Earthing complete with Galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32 mm x 6 mm up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in Electrical Plate No-5 of SSR-2014 (Part-I) NOTE-: GI earth strip shall be measured and paid for separately under relevant item of schedule complete all as specified and as directed. [ Lightning protection- 06 nos + External Elect 04 nos + DG set 04 nos ]
Micro Protect
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .