Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC Being Lowest and reasonable | |
| 2 | L2₹42.0 L+₹5.6 L (15.5%)Rejected-AOC | L2 | Rejected-AOC Not being Lowest Bidder | |
| 3 | L3₹43.7 L+₹7.4 L (20.4%)Rejected-AOC | L3 | Rejected-AOC Not being Lowest Bidder | |
| 4 | L4₹44.4 L+₹8.1 L (22.3%)Rejected-AOC | L4 | Rejected-AOC Not being Lowest Bidder | |
| 5 | L5₹47.7 L+₹11.3 L (31.1%)Rejected-AOC | L5 | Rejected-AOC Not being Lowest Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Garrison Engineer I R and D West Bengaluru
GARRISON ENGINEER I R AND D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
REPAIRS TO INTERNAL ELECTRIFICATION AND ALLIED WORKS AT LRDE BANGALORE
2022_MES_555347_1
GE(I)/R ND D/BAN/TOKEM/52 OF 2022-23 8109/E8
Open Tender
Civil Works
Item Rate
270 days
Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER I R AND D WEST BANGALORE
₹96,000
Yes
12 Nov 2022
1 Oct 2022
27 Oct 2022
2 Oct 2022
22 Oct 2022
17 Oct 2022
2 Oct 2022 - 15 Oct 2022
Amount
Taking down old / defective copper point wiring of any surface type (light, fan, socket or power) from the existing locations complete including fixture and fittings such as sunken boxes, laminated sheets along with switches, sockets, regulators, ceiling roses etc. removing materials and making good disturbed surfaces of walls, floors, ceiling etc to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge. Note : Cutiing chases / grooves etc on walls / ceilings as applicable as per site shall be measured and paid separately under relevent item as directed by Engineer-in-charge.
Taking down carefully existing old / unserviceable / burnt point wiring of any type (light, fan socket or power) complete from concealed / surface conduits or surface casing capping from controlling switch to light fitting/fan/socket etc as applicable on site complete in and including open concealed conduit blocks if any in inside of the walls, making good the same along with disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-charge. Note : Cutiing chases / grooves etc on walls / ceilings as applicable as per site shall be measured and paid separately under relevent item as directed by Engineer-in-charge.
Taking down carefully existing unserviceable / burnt sub main wiring of any size and type, taking down concealed / surface conduit, casing capping etc as per site conditions, making good the disturbed surfaces of walls, ceilings etc with two coats of white /colour washing/ distempering disturbed surfaces to match with the existing adjacent surfaces etc complete all as directed by Engineer-in-charge. Note - Cuttung/grooves/chiseling as applicable shall be measured and pad separately. (2) The quoted rate by the tenderer is inclusive for making good distrubed concealed/ surface conduit wiring portions in all respects to match with the adjoining surfaces.
Taking down old conventional light fittings of any type / wattage from any existing locations as per site conditions carefully with required ladders etc,making good the distrubed surfaces to match with the adjoining surfaces complete all as directed by Engineer-in-charge.
Material and labour point wiring with 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor for the following surface/recessed type in and including new PVC conduit of any size, complete with all PVC conduit and accessories/ fittings, brass screws, washers etc, along with modular suitable factory made Sunken boxes concealed including all cutting/chases as applicable etc or surface type PVC boxes factory made (where concealing boxes is not possible as per site conditions) to accomodate modular plates, covers modular switches & sockets etc in walls and including PVC insulated copper earth continuity conductor 1.5 Sqmm FRLS cable green colour connected to common earth dolly complete making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-charge for One light / fan / bell point controlled by one, one way switch 5/6 Amps complete all as specified and as directed. Note : Cutting / grooving / chiseling required as applicable for concealed wiring will be measured and paid separately under respective item.
All per Serial Item No 5 here-in-above, but suitable for 5-pin, socket outlet 5 Amps, fixed on independent board.
All per Serial Item No 5 here-in-above, but suitable for 5-pin, socket outlet 5 Amps, fixed on same board.
All per Serial Item No 5 here-in-above, but wiring complete with 2.5 Sqmm for 6 pin 15A socket multipurpose on independent board.
Material and labour for point wiring from switch board to light/fan/socket point with, single core, PVC insulated, unsheathed, multi stranded copper conductor, 1100 V grade, FRLS cable of size 1.5 sq.mm, 1100 grade, with single core, PVC insulated unsheathed multi stranded copper conductor cable of size 1.5 sq.mm for earth continuity wire, drawn into existing non metallic rigid surface/concealed PVC conduit or surface PVC casing of any size including all necessary wall cutting and making good disturbed surface complete all as specified and directed for One light / fan / bell point controlled by one, one way switch 5/6 Amps complete all as specified and as directed. Note : Cutting / grooving / chiseling required as applicable for taking out concealed wiring will be measured and paid separately under respective item.
All per Serial Item No 9 here-in-above, but suitable for 5-pin, socket outlet 5 Amps, fixed on independent board.
All per Serial Item No 9 here-in-above, but suitable for 5-pin, socket outlet 5 Amps, fixed on same board.
All per Serial Item No 9 here-in-above, but wiring complete with 2.5 Sqmm for 6 pin 15 Amp socket multipurpose on independent board.
Supply and fix Modular Switch, One module , One way, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix Modular socket, 6 Amps, 2/3 pin combined, 2 module, One way, 240 Volts all as specified and as directed.
Supply and fix Modular Switch, One module , One way, 16 Amps, 240 Volts all as specified and as directed.
Supply and fix, Modular socket outlet, 2 Module, 2/3 pin, 6/16 Amps (multi purpose), complete all as specified and directed.
Supply and fix in repairs, Modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply and fix in repairs, Ceiling rose surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply and fix in repairs, lamp holder, pin type, pvc/polycarbonate made, with and including LED pin type 9 Watt LED lamp complete all as specified and as directed by Engineer-in-charge.
Material and labour for submain wiring with Three single core PVC insulated cable copper conductor multi standed of size 4.0 Sqmm FRLS, including earth continuity drawn through in and including new PVC non mettallic rigid conduit/casing of suitable size concealed/surface type including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Three run of 4.0sqmm cable and one run of PVC conduit shall be measured as one length.
Material and labour for submain wiring with Three single core PVC insulated cable copper conductor multi standed of size 6.0 Sqmm FRLS, including earth continuity drawn through in and including new PVC non mettallic rigid conduit/casing of suitable size concealed/surface type including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Three run of 6.0sqmm cable and one run of PVC conduit shall be measured as one length.
Material and labour for submain wiring with Three single core PVC insulated cable copper conductor multi standed of size 10 Sqmm FRLS, including earth continuity drawn through in and including new PVC non mettallic rigid conduit/casing of suitable size concealed/surface type including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Three run of 6.0sqmm cable and one run of PVC conduit shall be measured as one length.
Material and labour for submain wiring with six single core PVC insulated cable copper conductor multi standed of size 6 Sqmm FRLS, including earth continuity drawn through in and including new PVC non mettallic rigid conduit/casing of suitable size concealed/surface type including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Six run of 6.0sqmm cable and one run of PVC conduit shall be measured as one length.
Material and labour for submain wiring with six single core PVC insulated cable copper conductor multi standed of size 10 Sqmm FRLS, including earth continuity drawn through in and including new PVC non mettallic rigid conduit/casing of suitable size concealed/surface type including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Six run of 10 sqmm cable and one run of PVC conduit shall be measured as one length.
Material and labour for submain wiring with six single core PVC insulated cable copper conductor multi standed of size 16 Sqmm FRLS, including earth continuity drawn through in and including new PVC non mettallic rigid conduit/casing of suitable size concealed/surface type including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - (i)Six run of 16 sqmm cable and one run of PVC conduit shall be measured as one length. (ii) For item no 20 to 25:- Cutting /grooving/chiseling as applicable as per site requirement shall be measured and paid separately under relevant item
Cutting chases, pinning in, where required for concealed conduit wiring, and making good disturbed surfaces to match with adjacent surfaces including pointing in cement mortar 1:3, girth not exceeding 15 cm on brick / PCC block masonry / concrete surfaces, complete all as specified and as directed.
Supply and fixing for replacement Rigid non-metallic PVC conduit of suitable size with boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as per site conditions complete specified and directed.
Supply and fixing wall mounted LED batten, 20 Watt, 4 feet, with high lumen output of 2000 lumens and diiffuser should be High translucent serrated milky white , environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH <20%, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80 & integrated electronic driver 20 W fitting prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. MAKE:- Crompton cat No.LCTLN-20-CD or techno equ in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing wall mounted LED tube light fitting 9 Watt 2 ft with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, complete with diffuser, polyestyer louver with 9 watt LED tube & integrated electronic driver 9 W prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. MAKE:- Crompton cat No.LCTLN- 9 -CD or techno equivalent in philips/ Havells /Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing LED ceiling mounted recessed full lit luminaire with glare free uniform illumination 36 W 2 feet x 2 feet (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95, THD<10%, CCT 5700K, CRI >= 80 and Driver Should be Constant Current LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. Cat Part No.LCTLRNE-36-FO-CDL of Crompton Greaves or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply and fixing LED ceiling surface mounted full lit luminaire with glare free uniform illumination 36 W 2 ft x 2 ft (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,THD<10%, CCT 5700K, CRI >= 80 and Driver Should be Constant Currnet LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. MAKE:- Crompton Cat No.LCTLSNE-36-FO-CDL or techno equ in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Recess mounted circular LED downlighter, 10/11Watt, with housing made up of die-cast aluminium for better heat management, high transmitivity diffuser for better light output and uniform light distribution without glare, driver and accessoires are pre wired for easy installation and long service, CRI > 80, LED efficacy > 130 lm/W, LED make:- Nichia / Cree / Osram / Everlite / Lumiled, ingress protection IP 20, ambient temperature range 0-45 degree centigrade, driver efficieny > 85% power factor > 0.95, THD < 20%, colour temp - 6500K, surge protection in CM - 2.5KV, 50000 burning hours (minium) as per L70 criteria, multi-stage isolated constant current operated driver with range 90-265V AC and safety extra low voltage safe level < 60V DC as per IEC Standard, cutout dia 165mm suitable for replacement of CFL downlighters, complete all as specified and directed. MAKE:- Cat No. INTEGRANEODLR10WLED840S of Havells / Cat No. DW295B LED 10S-4000PSUWH of Philips
Taking down old / unserviceable / burnt MCB DBs including MCBs of any type / size / rating, from existing positions carefully, making good disturbed surfaces to match with the adjoining surfaces as per site conditions complete all as directed by Engineer-in-charge.
Supply and fix, MCB DB SPN 12 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Supply and fix, MCB DB SPN 8 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Supply and fix, DB TPN 4 way (Vertical type), double door, with Sheet metal enclosure, for using MCCBs as incomer and outgoing circuits, flush mounted, prewired, 415 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCCB/MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Supply and fix, DB TPN 8 way (Vertical type), double door, with Sheet metal enclosure, for using MCCBs as incomer and outgoing circuits, flush mounted, prewired, 415 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCCB/MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Disconnecting all incoming and out going electrical connections carefully, Taking down old / unserviceable / burnt electrical main electrical sheet metal boxes of size 1.2 mtr x 1.0 mtr x 0,50 mtr (Appx) with all enclosures, electrical controls etc from existing positions carefully including making good distrubed surfaces to match with the adjoining surfaces as per site conditions complete all as directed by Engr-in-charge.
Supply, fixing and testing VTPN TPN DB 8 way Vertical Double door factory made powder coated with 200 Amps rated busbar 415 Volts capacity for using MCCB as incomer and MCBs as out going circuits complete all as specified and directed by Engr-in-charge. Note - Copper wires, MCCB s and MCBs as per site requireemnts shall be measured and paid separately under relevent item
Supply and fix MCCB 100 Amps 415 Volts 16 KA 4 pole using copper lugs for terminations including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCB 415 V 4 pole 160 Amps 25 KA using copper lugs for terminations including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply and fixing MCCB 415 V 4 pole 200 Amps 36 KA using copper lugs for terminations including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing SPN plug and socket enclosure with 20 Amps two pin and earth socket factory made powder coated with 200 Amps rated busbar 240 Volts with MCB SP 20 Amps complete all as specified and directed by Engr-in-charge. Make: Indoasian cat no.811955 or equivalent
Supply, fixing and testing TP plug and socket enclosure with three pin and earth socket factory made powder coated with 200 Amps rated busbar 415 Volts with MCB TP 32 Amps complete all as specified and directed by Engr-in-charge. Make: Indoasian cat no.811958 or equivalent
Supply and fix MCB SPN 32 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix MCB SPN 63 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix MCB TPN 32 Amp 415 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix MCB TPN 40 Amp 415 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix MCB TP 40 - 63 Amp 415 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix MCB SP 6 - 32 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Taking down existing ceiling fan/exhaust fan upto 1400 mm sweep with blade and down rods etc from ceiling/walls by unscrewing the nut bolts, opening the split pin and keeping in safe custody repairing and re-fixing the same after repairs, complete all as specified and as directed. Note: Repairs shall be measured and paid for separately under respective items.
Disconnecting, taking down ceiling fan upto 1400 mm sweep, with blade, inspecting motor assembly, replacing burnt out capacitors, split pins, etc, servicing, cleaning, greasing, removing all deposited materials, checking for smooth functioning, re-assembling the same complete all as specified and directed. NOTE:- Cost of PVC capacitor bracket -1 No, split pins - 6 Nos, 2.5 mfd capacitor - 1 No, shall deemed to include in this item.
Rewinding of ceiling fan motor upto 1400 mm sweep with super enameled copper winding wire of suitable gauge after cutting and removing burnt winding, including varnishing of new winding and drying up carefully all as specified and directed.
Dismantling / opening of exhaust fan of 300/450mm sweep motor assembly inspecting all dismantled parts repairing replacing the unserviceable parts and following components with new ones including oiling greasing reassembling motor assembly all as specified and directed. NOTE:- Cost of PVC capacitor bracket -1 No, split pins - 1 Nos, & 2 mfd Capacitor - 1 No, shall be included in this item.
Rewinding of exhaust fan motor 300/450 mm sweep with super enameled copper winding wire of suitable gauge after cutting and removing burnt winding, including varnishing of new winding and drying up carefully all as specified and directed.
Material and labour for preparing old painted surfaces of ceiling fans upto 1400 mm sweep, and applying spray painting with two coats of synthetic enamel paint of approved colour, including writing MES No on painted surfaces, complete all as specified and as directed.
Material and labour for preparing old painted surfaces of exhaust fans of 300/450 mm sweep, and applying spray painting with two coats of synthetic enamel paint of approved colour, including writing MES No on painted surfaces, complete all as specified and as directed.
Taking down old unserviceable/disconnected/broken building earthings complete of any type from existing locations all as per site conditions in and including necessary earth work complete all as directed by Engineer-in-charge.
Material and Labour for earthing complete with GI earth platee electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to GI wire 4 mm by brazing only earth strip protected with light grade GI Pipe 15 mm dia bore from earth plate electrode and upto in and including the earth test point including 20mm bore water pipe medium grade GI Tubing including GI Funnel,wire mesh. alternate 5 layers of charcoal & salt crystal and removal of the excavated soil and depositing at the place where directed,PCC Pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate , RCC (m) Cover 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm c/c both ways including RCC Pit Cover etc watering the earth pit to acheive earth resistance below 02 Ohm incl testing complete all as specified and directed by Engineer-in-Charge.Note :- GI wire 4 mm,GI Tubing 15 mm light grade upto 7.5 mtr deemed to be included in the rate quoted by the contractor.
Supply, fixing, drawning GI wire 4 mm in GI pipe 15 mm pipe in earthing complete all as specified and as directed by Engr - in -charge.
Supply and fix GI pipe light grade 15 mm dia on walls, roof / laid on floors, ground etc with all fittings, for GI Wire protection IN earthing all as specified and as directed by Engr - in -charge.
Checking of existing Copper/GI strip/GI wire earthings of any type near all buildings using all safety methods carefully, tightening of all earthing connections, pouring water in the earth pits throgh earth pit funnel properly, after 24 hrs of water pouring testing of earthing pit using earth tester (The arrangement of earth tester is the responsibility of contractor), white washing to earth pit, marked/painted with exterior paint date of earth result checked, earthing pit pertains to which equipment etc and reading in ohms etc properly and enter earth details and results in the register duly signed by electrician, contractor in all respects complete all as directed by Engineer-in-charge. NOTE : 1) The job shall be paid twice in the contract period with interval of Six months periodcity. 2) Earth work, demolition of PCC,PCC new work, RCC earth pit cover and GI strip as applicable shall be measured and paid separately under relevent item.
Demolition of old/damaged cement concrete of any description including foundation, wall and cover slabs in earth pits near buildings at various locations and carefully removing the debris from site and making good distrubed portions to match with the adjacent areas in all respects as per site conditions complete all as directed by Engr-in-charge.
Material and labour for providing plain cement concrete in 1:3:6 mix type C-1 (using 20 mm graded aggregate) in walls foundation etc of earth pits including necessary formwork complete all as specified and directed.
Material and labour for providing precast reinforced cement concrete earth pit cover slab of size 300x300mm, 40 mm thick in RCC (1:2:4) type B 1 (using 20 mm grade aggregate reinforced) including necessary formwork and reinforcement with 8 mm dia TMT bars @ 75mm c/c both ways complete as per site requirements all as specified and directed by Engineer-in-charge.
Material and labour for Air termination single pointed aluminium rod 12 mm dia and 300 mm long complete fixed on building roof in and including PCC block as per site conditions including taking down damaged air termination rod using necessary tools, plants and ladders complete all as directed by Engineer - in - charge.
Material and labour for aluminium strip 25 x 3.15 mm with insulators heavy duty, fxing screws etc for roof and down conductors complete all as per site conditions including taking down old damaged aluminium strip with insulators using necessary tools, plants and ladders complete all as specified and directed by Engineer-in-charge.
Material and labour for Earthing Complete with GI earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to GI strip of size 32 x 6 mm by brazing only earth strip protected with light grade GI Pipe 50 mm dia bore from earth plate electrode including 20mm bore water pipe medium grade GI Tubing including GI Funnel,wire mesh. alternate 5 layers of charcoal & salt crystal including excavation in strata, refiling and removal of the excavated soil and depositing at the place where directed,PCC Pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate , RCC (m) Cover 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways including suitable RCC Pit cover etc watering the earth pit to acheive earth resistance below 02 Ohm and necessary testing including taking down the existing old damaged lightening earthings at various locations complete all as specified and directed by Engineer-in-Charge. Note :- (1) Quoted rate deemend to included necessary earth work PCC chamber, RCC cover, renforcement removal of surplus soil , site clearance etc. (ii) GI earth strip 32X6 mm , GI tubing light grade 50 mm dia upto 7.5m deemed to be included in the rate quoted by the contractor.
Material and labour for GI Earth Strip 32mm X 6mm burried in ground / fixed on wall / floor as per site requirement beyond 7.5 meter for earthings / lightning buried strip etc as per site conditions complete all as specified and directed by Engineer-in-charge.
Supply and fix GI pipe light grade 50 mm dia on walls, laid in floors, ground etc with all earth work and fittings for GI strip protection all as specified and as directed by Engr - in -charge.
Material and labour Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete as per site requirements complete all as directed by Engineer - in - charge.
Fixing only properly GI Earth Strip of any type near existing earthings fixed on wall / floor in and including providing nuts, bolts and washers / soldering as per site requirements as per site requirement complete all as specified and directed by Engineer-in-charge.
Supply, fixing and testing LED galaxy strip of 20 wattage, not less than 60 LED per meter, extra bright 22 lumen.watt, superior grade adhesive, voltage 140V - 350V, 2 year warranty cert from manufctureres, colour of strip CDL/GRN/BLU/RED/PINK (length of strip not less than 5 Mtr) as per site requirementsall as specified and directed by Engineer-in-charge. Make - Model - Platina of Make Crompton or techno commercially eqivalent model in Make - Philips / Havells as approved by GE.
Supply, fixing and testing LED galaxy strip driver 24 Watt, out put 12 Volts 2 Amps, open & short circuit protection,surge protection upto 2.5 KV, compact size, voltage 140V-350V, 20 wattage, 2 year warranty certificate from manufctureres suitable for colour of strip CDL/GRN/BLU/RED/PINK (length of strip not less than 5 Mtr) as per site requirements all as specified and directed by Engineer-in-charge. Make - Cat No LSTDRV-12V-2A of Make crompton or techno commercially eqivalent model in Make - Philips / Havells as approved by GE.
Supply fixing connections soldering and testing Copper PVC Flat cable of size 23/0.0076 white or any other as per site requirements for connecting strip from source of supply etc all as specified and directed by Engineer-in-charge. Make - Anchor / Finoles/ Havells / polycab or any equivalent specifications make as approved by GE.
Vishwas Enterprises
Ashraya Nirman
M/S Sneha Enterprises
RADHIKAGANESH ENTERPRISES
MAJ CONSTRUCTIONS
kamadhenu Electricals
UNIVERSAL ENGINEERING
GS TRADERS
H S S ENGINEERS AND CONTRACTORS
Arunachaleswara enterprises
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .