Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹49.8 L+₹2.3 L (4.75%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Being Other than Lowest Tenderer | |
| 3 | L3₹50.2 L+₹2.6 L (5.56%)Rejected-Finance VILL RATTANPUR PO TEH JOURIAN DISTT JAMMU J K 181202 | JAMMU | JAMMU AND KASHMIR | 181202 | L3 | Rejected-Finance Being Other than Lowest Tenderer | |
| 4 | L4₹50.3 L+₹2.7 L (5.68%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Being Other than Lowest Tenderer | |
| 5 | Rejected-Technical 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | - | Rejected-Technical Contractor has withdrawn his bid due to heavy work load vide his letter No Nil dated 11 Nov 2025 |
| Sl No | Description | Qty | Unit | TETRI ENTERPRISES L1 | Rama Construction Co L3 | Shree Ayyappa Engineering L2 | SHREE JAGDISH FURNITURE CO. L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Routine maintenance of DG set from authorised service representative for not less than 11 visits in a calender year and whenever required as per direction of JE/AGE/GE with at least once in a month to attend the DG set 600 KVA capacity located at INS Angre regularly to carrying out scheduled preventive maintenance checks on diesel generating set (of any Make) and to carryout the under mentioned A ,B or C check/works during the calender year all as directed by Engineer-in-Charge (a) Carry out maintenance/check as per maitenance schedule during every visit as per contract complete all as specified and as directed.
Note 1 : All spare parts will be measured & paid saparately.
Note 2 : Consumables like grease, cotton, screw etc.is deemed to be included the rate quoted by the contractor for comprehensive/routine maint.
Note 3 : Cost of routine DG set servicing deemed to be included in quoted rates. | 11 | Per month | 5,000 ₹55,000 | 5,600 ₹61,600 | 2,000 ₹22,000 Lowest | 5,555 ₹61,105 |
| 2.00 | All as per item No 1 above but 125 KVA located at PCDA (Navy) complete all as specified and as directed. | 11 | Per month | 3,200 ₹35,200 | 3,290 ₹36,190 | 2,000 ₹22,000 Lowest | 5,555 ₹61,105 |
| 3.00 | All as per item No 1 above but of 125 KVA located at INS Aganibahu complete all as specified and as directed. | 11 | Per month | 3,200 ₹35,200 | 3,400 ₹37,400 | 2,000 ₹22,000 Lowest | 5,555 ₹61,105 |
| 4.00 | All as per item No 1 above but of 160 KVA located at CG Complex complete all as specified and as directed. | 11 | Per month | 3,400 ₹37,400 | 3,300 ₹36,300 | 2,000 ₹22,000 Lowest | 6,147 ₹67,617 |
| 5.00 | All as per item No 1 above but of 500 KVA located at HQ WNC Naval Dockyard complete all as specified and as directed. | 11 | Per month | 3,400 ₹37,400 | 3,457 ₹38,027 | 2,000 ₹22,000 Lowest | 7,777 ₹85,547 |
| 6.00 | All as per item No 1 above but of 62.50 KVA located at HQ CE (Navy) complete all as specified and as directed. | 11 | Per month | 3,500 ₹38,500 | 3,200 ₹35,200 | 2,000 ₹22,000 Lowest | 5,555 ₹61,105 |
| 7.00 | All as per item No 1 above but of 30 KVA located at BV yard complete all as specified and as directed. | 11 | Per month | 3,500 ₹38,500 | 5,800 ₹63,800 | 2,000 ₹22,000 Lowest | 5,200 ₹57,200 |
| 8.00 | All as per item No 1 above but of 20 KVA located at Oyster rock/ Middle ground -02 nos complete all as specified and as directed. | 11 | Per month | 1,900 ₹20,900 Lowest | 2,190 ₹24,090 | 2,000 ₹22,000 | 5,200 ₹57,200 |
| 9.00 | All as per item No 1 above but of 40 KVA located at Oyster rock/ Middle ground -02 nos complete all as specified and as directed. | 11 | Per month | 1,900 ₹20,900 Lowest | 2,287 ₹25,157 | 2,000 ₹22,000 | 5,555 ₹61,105 |
| 10.00 | All as per item No 1 above but of 15 KVA located at Oyster rock/ Middle ground -02 nos complete all as specified and as directed. | 11 | Per month | 1,500 ₹16,500 Lowest | 4,500 ₹49,500 | 2,000 ₹22,000 | 6,147 ₹67,617 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Nov 2025, 6:55 pmClosed
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8239 REPAIR/ MAINT OF VARIOUS DG SETS INSTALLED AT VARIOUS LOCATIONS UNDER GE (NW) KUNJALI
2025_MES_735019_1
8239/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
20 Dec 2025
14 Oct 2025
6 Nov 2025
23 Oct 2025
4 Nov 2025
28 Oct 2025
14 Oct 2025 - 23 Oct 2025
Amount
Routine maintenance of DG set from authorised service representative for not less than 11 visits in a calender year and whenever required as per direction of JE/AGE/GE with at least once in a month to attend the DG set 600 KVA capacity located at INS Angre regularly to carrying out scheduled preventive maintenance checks on diesel generating set (of any Make) and to carryout the under mentioned A ,B or C check/works during the calender year all as directed by Engineer-in-Charge (a) Carry out maintenance/check as per maitenance schedule during every visit as per contract complete all as specified and as directed. Note 1 : All spare parts will be measured & paid saparately. Note 2 : Consumables like grease, cotton, screw etc.is deemed to be included the rate quoted by the contractor for comprehensive/routine maint. Note 3 : Cost of routine DG set servicing deemed to be included in quoted rates.
All as per item No 1 above but 125 KVA located at PCDA (Navy) complete all as specified and as directed.
All as per item No 1 above but of 125 KVA located at INS Aganibahu complete all as specified and as directed.
All as per item No 1 above but of 160 KVA located at CG Complex complete all as specified and as directed.
All as per item No 1 above but of 500 KVA located at HQ WNC Naval Dockyard complete all as specified and as directed.
All as per item No 1 above but of 62.50 KVA located at HQ CE (Navy) complete all as specified and as directed.
All as per item No 1 above but of 30 KVA located at BV yard complete all as specified and as directed.
All as per item No 1 above but of 20 KVA located at Oyster rock/ Middle ground -02 nos complete all as specified and as directed.
All as per item No 1 above but of 40 KVA located at Oyster rock/ Middle ground -02 nos complete all as specified and as directed.
All as per item No 1 above but of 15 KVA located at Oyster rock/ Middle ground -02 nos complete all as specified and as directed.
All as per item No 1 above but of 5 KVA located at Oyster rock/ Middle ground -02 nos complete all as specified and as directed.
All as per item No 1 above but Diesel pump set at INS Trata/FMU/INS Kunjali complete all as specified and as directed.
Supply and fix in repair LT UG Cable on wall/floor/ceiling with proper saddles, including testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size 6 sq mm 2 core complete all as specified and as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc shall be including in the quoted rate and no extra payment will be made for it. 2. The excavation, earth work, sand cushioning and brick protection etc will be measured and paid separately under respective items.
All as per item No 13 above but of size 16 sq mm X 2 core complete all as specified and as directed.
All as per item No 13 above but of size 25 sq mm X 3.5 core complete all as specified and as directed.
All as per item No 13 above but of size 35 sq mm X 3.5 core complete all as specified and as directed.
All as per item No 13 above but of size 50 sq mm X 3.5 core complete all as specified and as directed.
All as per item No 13 above but of size 70 sq mm X 3.5 core complete all as specified and as directed.
All as per item No 13 above but of size 120 sq mm X 3.5 core complete all as specified and as directed.
All as per item No 13 above but of size 185 sq mm X 3.5 core complete all as specified and as directed.
All as per item No 13 above but of size 240 sq mm X 3.5 core complete all as specified and as directed.
All as per item No 13 above but of size 400 sq mm X 3.5 core complete all as specified and as directed.
Supply and fixing in replacement of galvanised pipe medium grade 100 mm dia for passing of cables under the road complete all as specified and as directed.
Supply and fixing in replacement of galvanised pipe medium grade 80 mm dia for passing of cables under the road complete all as specified and as directed.
Supply and fixing in replacement of galvanised pipe medium grade 50 mm dia for passing of cables under the road complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 deep & getting out for attending cable fault complete as directed in soft/loose soil complete all as specified and directed
Returning, filling in including spreading leveling watering well ramming inlayers not exceeding.25cm all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50M and deposited where as directed all as specified
Material and labour for spreading levelling river sand cushioning in trenches around the cable complete all as specified and as directed. Note :- Thickness of punning sand only will be measured & paid.
Material and labour for un-reinforced,precast concrete cable cover of flat size 250x150x40mm class LV type I for cable protection including taking down old unserviceable cover complete all as specified and as directed.
Cutting existing road surfaces or hard standing 0.45M depth (22Cm thick comprising bituminous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing complete all as specified and directed.
Supply and fix cable joint kit 1100Volts grade cable for jointing straight through complete with jointing material (Heat Shrinkable,Tubular Verson) and accessories suitable for 3.5core 25 to 50 Sqmm XLPE armoured aluminum conductor cable including excavation, returning filling in spreading, leveling, well ramming in layers, soiling , complete and making good disturbed surfaces to match with existing complete all as specified and directed.
All as per Item No 30 above but suitable for cable size 3.5 core 70 sqmm to 150 Sqmm complete all as specified and as directed.
All as per Item No 30 above but suitable for cable size 3.5 core 185 sqmm to 400 sqmm complete all as specified and as directed.
Supply of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weather proof incl complete all as specified and as directed. Note : Back-fill compound shall not be mixed with any soil while pouring in the bore hole.
Earthing continuity galvanised iron strip 25 x 3 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed.
Supply and fix in repair aluminium lugs suitable for existing LT cable of size Aluminium lugs of size up to 50 sqmm complete all as specified and as directed.
All as per item No.36 but for aluminium lugs of size 70 to 120 sqmm complete all as specified and as directed.
All as per item No.36 but for Aluminium lugs of size 185 to 400 sqmm complete all as specified and as directed.
Supply & fix power contactors suitable for 50Amps,415Volts,50Hz AC complete all as specified and as directed. Make : L&T/ C&S/CG or equivalent make approved by GE
Supply & fix HRC Fuse DIN type suitable for 125Amps,415Volts,50Hz AC complete all as specified and as directed. Make : C&S/Standard/HPL/L&T or equivalent make approved by GE
Supply & fix HRC Fuse DIN type suitable for 63 Amps,415Volts,50Hz AC complete all as specified and as directed. Make : C&S/Standard/HPL/L&T or equivalent make approved by GE
Supply & fix APFC relay, 12 stages digital type suitable for 415V, 3phase, AC supply complete all as specified and as directed. Make - L&T/ Syntron/KB/ or equivalent make approved by GE
Supply, fix ,test and commissioning in repair in existing panel MCCB. 4 Pole 400 Amps,50 KA suitable for 415V, 3phase, AC complete all as specified and directed . Make : Schneider/L&T/C&S/Havells/HPL/IndoAsian or equivalent make approved by GE
Supply and fixing in repair in existing panel MCCB,350 Amps,3pole ,36kA complete all as specified and directed. Make : Schneider/L&T/C&S/Havells/HPL/IndoAsian or equivalent make approved by GE
Supply and fixing in repair in existing panel MCCB, 250Amps,36KA,3pole complete all as specified and directed.Make : Schneider/L&T/C&S/Havells/HPL/IndoAsian or equivalent make approved by GE
Supply and fixing in repair in existing panel MCCB 160Amps,3pole,25kA complete all as specified and directed.Make : Schneider/L&T/C&S/Havells/HPL/IndoAsian or equivalent make approved by GE
Supply and fixing in repair in existing panel MCCB 100Amps,3pole,16kA complete all as specified and directed . Make : Schneider/L&T/C&S/Havells/HPL/IndoAsian or equivalent make approved by GE
Supply and fix of MCCB sheet metal enclosure suitable for holding MCCB of 100 to 400 amp capacity four pole type including fixing accessories etc complete all as specified and directed . Make: Havells/ Legrand/ C & S or equivalent make approved by GE
Supply and fixing in repair on load change over switch 400 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete with sheet metal enclosure complete all as specified and directed . Make : Siemens, C & S,Schneider or equivalent make approved by GE
Supply and fixing in repair on load change over switch 250 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete with sheet metal enclosure complete all as specified and directed . . Make : Siemens, C & S,Schneider or equivalent make approved by GE
Supply and fixing in repair on load change over switch 160 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete with sheet metal enclosure complete all as specified and directed . Make : Siemens, C & S,Schneider or equivalent make approved by GE
Material and labour for spray painting of LT panel board/switch gears with one coat of grey synthetic enamelled paint or any paint as per existing pattern including filling cavities of any with filler after necessary scrapping cleaning and preparation etc complete all as specified and directed . NOTE: Item no. 24 to 34 (rate quoted by contractor deemed to be included for drilling the holes to bus bar, providing suitable size of lugs, nuts and bolts etc and MS sheet fabricated made out of 2 mm/3 mm thick CRCA sheet as base for fixing MCCB etc complete)
Supply and fix in repair of Fuel filter of DG Sets 600 KVA complete all as specified and directed .
All as per item No. 55 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 55 above but for By pass oil filter complete all as specified and directed .
All as per item No. 55 above but for CR filter plate & 'O' ring complete all as specified and directed .
All as per item No. 55 above but for Air filter (inner and outer) complete all as specified and directed .
Supply and fix in repair of Fuel filter of of DG Sets 500 KVA complete all as specified and directed .
All as per item No. 56 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 56 above but for By pass oil filter complete all as specified and directed .
All as per item No. 56 above but for CR filter plate & 'O' ring complete all as specified and directed .
All as per item No. 56 above but for Air filter (inner and outer) complete all as specified and directed .
Supply and fix in repair of Fuel filter of of DG Sets 160 KVA complete all as specified and directed .
All as per item No. 57 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 57 above but for By pass oil filter complete all as specified and directed .
All as per item No. 57 above but for CR filter plate & 'O' ring complete all as specified and directed .
All as per item No. 57 above but for Air filter (inner and outer) complete all as specified and directed .
Supply and fix in repair of Fuel filter of of DG Sets 125 KVA complete all as specified and directed .
All as per item No. 58 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 58 above but for By pass oil filter complete all as specified and directed .
All as per item No. 58 above but for CR filter plate & 'O' ring complete all as specified and directed .
All as per item No. 58 above but for Air filter (inner and outer) complete all as specified and directed.
Supply and fix in repair of Fuel filter of of DG Sets 62.50 KVA complete all as specified and directed.
All as per item No. 59 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 59 above but for By pass oil filter complete all as specified and directed .
All as per item No. 59 above but for CR filter plate & 'O' ring complete all as specified and directed.
All as per item No. 59 above but for Air filter (inner and outer) complete all as specified and directed.
Supply and fix in repair of fuel filter DG Sets 30/40 KVA complete all as specified and directed .
All as per item No. 60 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 60 above but for By pass oil filter complete all as specified and directed .
All as per item No. 60 above but for CR filter plate & 'O' ring complete all as specified and directed .
All as per item No. 60 above but for Air filter (inner and outer) complete all as specified and directed.
Supply and fix in repair of Fuel filter of DG Sets 20 KVA complete all as specified and directed .
All as per item No. 61 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 61 above but for By pass oil filter complete all as specified and directed .
All as per item No. 61 above but for CR filter plate & 'O' ring complete all as specified and directed .
All as per item No. 61 above but for Air filter (inner and outer) complete all as specified and directed.
Supply and fix in repair of Fuel filter of DG Sets 15 KVA complete all as specified and directed .
All as per item No. 62 above but for Lub Oil filter complete all as specified and directed .
All as per item No. 62 above but for By pass oil filter complete all as specified and directed .
All as per item No. 62 above but for CR filter plate & 'O' ring complete all as specified and directed .
All as per item No. 62 above but for Air filter (inner and outer) complete all as specified and directed
Dismantling of radiator complete from D G Sets cleaning/ scraping of deposite manually from outside of the radiator, cleaning of all copper tubes of radiator with descalling solution from inside & outside with forced feed method & with water and aircompressor (by using separate chemical pump water pump & all compressor ) plugging of all leakage in welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc for DG sets of capacity 600KVA complete all as specified and directed .
All as per item No. 63 above but for 500 KVA complete all as specified and directed .
All as per item No. 63 above but for 160 KVA complete all as specified and directed .
All as per item No. 63 above but for 125 KVA complete all as specified and directed .
All as per item No. 63 above but for 40 KVA complete all as specified and directed .
All as per item No. 63 above but for 20 KVA complete all as specified and directed .
All as per item No. 63 above but for 15 KVA complete all as specified and directed .
Supply and fix battery suitable for 12 Volts, 180 AH DC complete all as specified and directed . Make :- Exide / Amron or equivalent make approved by GE
Material and labour for manual scraping of old painted surface and providing spray painting with one coat of synthetic enamelled paint of aquostic enclosure of DG Sets of capacity 600KVA complete all as specified and directed .
All as per item No. 65 above but for 500 KVA complete all as specified and directed .
All as per item No. 65 above but for 160 KVA complete all as specified and directed .
All as per item No. 65 above but for 125 KVA complete all as specified and directed .
All as per item No. 65 above but for 40 KVA complete all as specified and directed .
All as per item No. 65 above but for 30 KVA complete all as specified and directed .
All as per item No. 65 above but for 20 KVA complete all as specified and directed .
Material and labour for manual scraping of old painted surface and providing spray painting with one coat of synthetic enamelled paint on outer surface body of DG Sets of capacity 600KVA complete all as specified and directed .
All as per item No. 66 above but for 500 KVA complete all as specified and directed .
All as per item No. 66 above but for 160 KVA complete all as specified and directed .
All as per item No. 66 above but for 125 KVA complete all as specified and directed .
All as per item No. 66 above but for 40 KVA complete all as specified and directed .
All as per item No. 66 above but for 30 KVA complete all as specified and directed .
All as per item No. 66 above but for 20 KVA complete all as specified and directed .
All as per item No. 66 above but for 15 KVA complete all as specified and directed .
Material and labour for replacement of battery terminals made of brass and suitable for battery and terminal complete all as specified and directed .
Material and labour for replacement of battery lead set of two suitable for 180 AH capacity, 1.5m long including brass terminal one end, copper lug other end complete all as specified and directed .
Material and labour taking out old u/s fan belt and supply and fix new fan belt sutable for DG set Cap upto 40/30/15 KVA complete all as specified and directed .
All as per item No 69 above but of capacity 125/160 KVA complete all as specified and directed .
All as per item No 69 above but of capacity 500 KVA complete all as specified and directed .
All as per item No 69 above but of capacity 600 KVA complete all as specified and directed .
All as per item No 69 above but of capacity 20 KVA complete all as specified and directed .
Supply and filling lubricant oil of 20w/40 and 15w/40 of various capacity of DG sets at various location under GE (NW) Kunjali complete all as specified and directed.
Material and labour for replacement of carbon bushes suitable for capacity of DG set 600 KVA to match with the existing/manufacturer complete all as specified and directed.
All as per item No 71 above but of capacity 500 KVA complete all as specified and directed .
All as per item No 71 above but of capacity 160 KVA complete all as specified and directed .
All as per item No 71 above but of capacity 125 KVA complete all as specified and directed .
All as per item No 71 above but of capacity 62.50 KVA complete all as specified and directed .
All as per item No 71 above but of capacity 40 KVA complete all as specified and directed .
All as per item No 71 above but of capacity 30 KVA complete all as specified and directed .
All as per item No 71 above but of capacity 20 KVA complete all as specified and directed .
All as per item No 71 above but of capacity 15 KVA complete all as specified and directed .
Dismantling the sump cover for cleaning, removing sludge, dust etc and re-fixing including replacement of sump gasket including wiriting the date of DG Sets of capacity 600KVA complete all as specified and directed .
All as per item No 72 above but of capacity 500 KVA complete all as specified and directed .
All as per item No 72 above but of capacity 160 KVA complete all as specified and directed .
All as per item No 72 above but of capacity 125 KVA complete all as specified and directed .
All as per item No 72 above but of capacity 62.50 KVA complete all as specified and directed .
All as per item No 72 above but of capacity 40 KVA complete all as specified and directed .
All as per item No 72 above but of capacity 30 KVA complete all as specified and directed .
All as per item No 72 above but of capacity 20 KVA complete all as specified and directed .
All as per item No 72 above but of capacity 15 KVA complete all as specified and directed .
Material and labour for opening, checking, adjusting and tightening of tappet complete by torque wrench by applying proper pressure as per manufacturer norms including replacement of tappet cover gasket of capacity 600 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 500 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 160 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 125 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 62.50 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 40 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 30 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 20 KVA complete all as specified and directed .
All as per item No 73 above but of capacity 15 KVA complete all as specified and directed .
Material and labour for Fuel tank repairing of any capacity incl necessary welding, brazing work at site as complete all as specified and directed .
Supply only coolant for radiator suitable for all DG set KVA complete all as specified and directed . Make- Cummins/ Kirloskar/ Ashok Leyland green, or equivalent make approved by GE ,shall be done as per manufacturers recommendations
Material and labour for rewinding of self starter coil, 24 Volts, with existing size of copper winding wire including varnishing and replacement of bush bearing, carbon bush, clutch plate set, pinion etc for DG set of any capacity complete all as specified and directed .
Material and labour for disconnecting all electrical connection from alternator and disconnecting from engine and taking out to civil workshop for rewinding of alternator with super enamelled copper conductor with existing size of copper winding wire including varnishing and replacement of bush bearing, carbon bush etc and assembling back after repair including testing and commissioning for DG set of capacity 600KVA complete all as specified and directed .
All as per item No 77 above but of capacity 500 KVA complete all as specified and directed .
All as per item No 77 above but of capacity 160/125 KVA complete all as specified and directed .
All as per item No 77 above but of capacity 40 KVA complete all as specified and directed .
All as per item No 77 above but of capacity 20/30 KVA complete all as specified and directed .
Material and labour for replacement of ignition switch with key and wiring complete upto 125/40/30/20 KVA complete all as specified and directed .
Material and labour for replacement of ignition switch with key and wiring complete 500 to 600 KVA complete all as specified and directed .
Material and labour for replacement of water temperature gauge with wiring suitable for up to 125/40/30/20 KVA complete all as specified and directed .
Material and labour for replacement of water temperature gauge with wiring suitable for 500/600 KVA complete all as specified and directed .
Material and labour for replacement of oil pressure gauge with wiring suitable for up to 125/40/30/20 KVA complete all as specified and directed .
Material and labour for replacement of oil pressure gauge with wiring suitable for 500/600 KVA complete all as specified and directed .
Material and labour for replacement of RPM meter with cable complete all as specified and directed .Make : Yankey/Pricol or equivalent make approved by GE
Material and labour for replacement of push button switch for starting the DG Set upto 125 KVA complete all as specified and directed . Make : Lucas or equivalent make approved by GE
Material and labour for replacement of push button switch for starting the DG Set 500/600 KVA complete all as specified and directed . Make : Lucas or equivalent make approved by GE
Material and labour for replacement of asbestos rope on exhaust pipe complete all as specified and directed .
Material and labour for PVC rubber coupling for connecting/coupling to Engine and alternator of size 125KVA complete all as specified and directed .
All as per item No 88 above but of capacity 600 KVA complete all as specified and directed .
All as per item No 88 above but of capacity 40/30/20/15 KVA complete all as specified and directed.
Replacement of complete fuel and lubricant oil flexible pipes of DG set of capacity 600KVA complete all as specified and directed .
All as per item No 89 above but of capacity 500 KVA complete all as specified and directed .
All as per item No 89 above but of capacity 160 KVA complete all as specified and directed .
All as per item No 89 above but of capacity 125 KVA complete all as specified and directed .
All as per item No 89 above but of capacity 62.50 KVA complete all as specified and directed .
All as per item No 89 above but of capacity 40 KVA complete all as specified and directed .
All as per item No 89 above but of capacity 20/30 KVA complete all as specified and directed .
All as per item No 89 above but of capacity 15 KVA complete all as specified and directed .
Supply and fix in replacement of defective automatic voltage rectifier(AVR) of 125 KVA DG set as per the existing complete all as specified and directed .
Supply and fix in replacement of defective automatic voltage rectifier(AVR) of 500/600 KVA DG set as per existing complete all as specified and directed .
Supply and fix in replacement of defective automatic voltage rectifier(AVR) of 62.50 KVA DG set as per existing complete all as specified and directed .
Supply and fix in replacement of defective automatic voltage rectifier(AVR) of 20/40/15 KVA DG set as per existing complete all as specified and directed .
Complete repairing & over hauling including calibration of injector assembly with replacement of plunger/ nozzle , lugs, corner gasket and other defective spares of DG Set of capacity 125/160KVA complete all as specified and directed .
All as per item No 94 above but of capacity 40/30/15 KVA complete all as specified and directed .
All as per item No 94 above but of capacity 500/600 KVA complete all as specified and directed .
Complete repair overhauling and calibration of FIP/PT pump incl replacement of complete repair kit required for the capacity 125/160 KVA complete all as specified and directed .
All as per item No 95 above but of capacity 62.50 KVA complete all as specified and directed .
All as per item No 95 above but of capacity 40/30/15 KVA complete all as specified and directed .
All as per item No 95 above but of capacity 500/600 KVA complete all as specified and directed .
Complete repairing & over hauling and assembly of Radiator Core and other defective spares of DG Set 30/40/62.50/125 KVA complete all as specified and directed .
Complete repairing & over hauling and assembly of Radiator Core and other defective spares of DG Set 500/600 KVA complete all as specified and directed .
Material and labour in replacement of door mounted controller with auto and manual mode for DG set of capacity upto 40 KVA, three phase, 415V having all required inputs and outputs suitable for existing make complete all as specified and directed.
Material and labour in replacement of door mounted controller with auto and manual mode for DG set of capacity 125/160 KVA, three phase, 415V having all required inputs and outputs suitable for existing make complete all as specified and directed.
M & L for fabricating IP 54 outdoor canopy of 30 KVA Dg set with servicing of suspension system including scrapping of rust and old paint and including painting of frame and canopy and body of Dg set with existing color pattern with synthetic enamel paint complete all as specified and directed .
Supply & fix in replacement of power contactor 200Amps, 415V, 50Hz complete all as specified and directed. Make :- Telemecanique or equivalent make as approved by GE
Supply and fixing in replacement of 5 KVA DG Set comprising of CPCB-IV, 3000 RPM, 4 Stroke , 1 cylinder, air cooled with radiator diesel engine coupled with NSM make 5 KVA /4 KW, 230 Volts, single phase, 50 Hz, 0.8 PF, alternator complete with fuel tank, battery with leads, residential type silencer control panel with auto start stop facility all standard accessories complete all as specified and directed.
Supply and fix insulation mat as per IS 15652:2006, having not less than 30kV dielectric strength and having insulation resistance of not less than 1MOhm, acid retardent, flame retardent, having width of 1.0mtr and length upto 2.0 mtr, of thickness 10 mm complete all as specified and directed .
Supply and fix insulation mat as per IS 15652:2006, having not less than 30kV dielectric strength and having insulation resistance of not less than 1MOhm, acid retardent, flame retardent, having width of 1.0mtr and length upto 2.0 mtr, of thickness 12 mm
Supply and fixing battery charger 12V- 10 Amps, fixed in the existing panel of DG set including all accessories complete all as specified and as directed.
Taking out ACB breaker for repair and servicing by disconnecting and dismantling the ACB breaker any rating Amps any make by carrying out repair/ servicing , checking and renewing the defective shunt trip coil & UV trip 415 V AC , checking and rectifying the defective CTs and rectifying the mechanism operation including spring charge system, reinstalling the same in the panel and providing necessary line and complete all as specified and directed .
M & L for the PVC board of appropriate size and thickness duly pasted with computerised letter mentioning " NO SMOKING" , " DANGER 11000 volts with skull and cross painted, " NO ADMISSION EXCEPT ON DUTY, " SM/MES NO." for the transformer/HT breakers/DG sets including accessories etc for the substations including accessories for properly fixing the same on wall/fencing/pole etc complete all as specified and directed .
M & L for outdoor display board of appropriate size and thickness (size upto 5m x 3m x 0.20m) with computerised 3D letter not less than 8 inches in blue colour on acrylic sheet mentioning name of substation with lighting arrangement at backside complete all as specified and directed . Note : The contents for the board will be provided by Engineer in charge and cost of fabrication of aluminium frame for the board is deemed to be included in the quoted rates.
M & L for fixing standard shock treatment chart in English & Hindi duly framed and covered with glass complete all as specified and directed.
Material and labour for repairing and servicing of fuel pump any capacity including necessary welding/ brazing work at site complete all as specified and directed .
Shree Ayyappa Engineering (BID ID -3466883)
Rama Construction Co (BID ID -3466312)
SHREE JAGDISH FURNITURE CO. (BID ID -3466744)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.27 MB
BOQ
BOQ • 1.38 MB
Tender Documents
Tender Documents • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .