Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.3 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BEING L-1 | |
| 2 | 2₹33.0 L+₹27,449.79 (0.84%)Rejected-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 2 | Rejected-AOC REJECTED NOT BEING L-1 | |
| 3 | 3₹33.1 L+₹40,503.27 (1.24%)Rejected-AOC VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | 3 | Rejected-AOC REJECTED NOT BEING L-1 | |
| 4 | 4₹35.9 L+₹3.2 L (9.90%)Rejected-AOC | 4 | Rejected-AOC REJECTED NOT BEING L-1 | |
| 5 | 5₹37.0 L+₹4.4 L (13.4%)Rejected-AOC NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | 5 | Rejected-AOC REJECTED NOT BEING L-1 |
| Sl No | Description | Qty | Unit | m/S Varun Gupta L5 | M/s. Rishav Sood L4 | Havish Construction L3 | M/s Shakti Electric Works L2 | R.K.CONSTRUCTION ENGINEERS L1 | Eshaan Construction Co. L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. | 13.8 | Cum | 455 ₹6,279 | 225 ₹3,105 | 145 ₹2,001 Lowest | 200 ₹2,760 | 501.11 ₹6,915.32 | 500 ₹6,900 |
| 2.00 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. | 1.75 | Cum | 200 ₹350 | 225 ₹393.75 | 145 ₹253.75 Lowest | 200 ₹350 | 501.11 ₹876.94 | 500 ₹875 |
| 3.00 | Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. | 28.5 | Cum | 200 ₹5,700 | 225 ₹6,412.5 | 145 ₹4,132.5 Lowest | 500 ₹14,250 | 251.11 ₹7,156.64 | 500 ₹14,250 |
| 4.00 | Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed | 1,045.66 | Sqm | 15 ₹15,684.9 | 14 ₹14,639.24 | 9 ₹9,410.94 Lowest | 20 ₹20,913.2 | 11.11 ₹11,617.28 | 150 ₹1,56,849 |
| 5.00 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed. | 465 | Sqm | 55 ₹25,575 | 14 ₹6,510 Lowest | 15 ₹6,975 | 20 ₹9,300 | 51.11 ₹23,766.15 | 20 ₹9,300 |
| 6.00 | Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. | 322 | Sqm | 15 ₹4,830 | 10 ₹3,220 Lowest | 10 ₹3,220 Lowest | 50 ₹16,100 | 31.11 ₹10,017.42 | 40 ₹12,880 |
| 7.00 | Taking down and removing chowkats with shutters (without taking off shutters from chowkat) not exceeding 1.50 Sqm each complete all as specified and directed. | 48 | Each | 225 ₹10,800 | 125 ₹6,000 | 145 ₹6,960 | 30 ₹1,440 Lowest | 201.11 ₹9,653.28 | 400 ₹19,200 |
| 8.00 | Taking down and removing chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. | 36 | Each | 225 ₹8,100 | 275 ₹9,900 | 145 ₹5,220 | 40 ₹1,440 Lowest | 201.11 ₹7,239.96 | 400 ₹14,400 |
| 9.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. | 4 | Qtl | 155 ₹620 Lowest | 500 ₹2,000 | 495 ₹1,980 | 1,000 ₹4,000 | 201.11 ₹804.44 | 3,000 ₹12,000 |
| 10.00 | Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. | 170 | Sqm | 15 ₹2,550 | 12 ₹2,040 | 9 ₹1,530 Lowest | 50 ₹8,500 | 51.11 ₹8,688.7 | 80 ₹13,600 |
Tender Value
₹42.6 L
EMD Value
₹85,280
Closing Date
9 Jan 2026, 6:00 pmClosed
CWE YOL
HEADQUARTERS COMMANDER WORKS ENGINEER YOL
SPECIAL REPAIR TO BLDG NO. BK-117AND BK-111 (OR MD ACCN) AT SFTS BAKLOH
2025_MES_745050_1
CWE/Y-82/2025-26
Open Tender
Civil Works
Works
180 days
BAKLOH
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE PALAMPUR
₹85,280
Yes
27 Feb 2026
19 Dec 2025
16 Jan 2026
19 Dec 2025
9 Jan 2026
2 Jan 2026
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed.
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
PCC 1:2:4( nominal mix) type B-2 (using 40mm graded crushed stone aggregates) as in surface channel and drain all as specified and directed.
Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in built in cement mortar 1:6 all as specified & directed.
2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Powder coated (minimum thickness of powder coating 50 micron), Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing of glass, particle board,aluminium frame etc complete all as specified and directed.
Factory Made Solid PVC Moulded Door Shutter (Woood free EPS) , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed.
35 mm thick 2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of door shutters as specified in SSR- 2009 Part-I Section 8.24(a) complete all as specified and directed.
20mm dia Curtain rod/Harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc, complete all as specified.
Aluminium anodised snap grid frame (Powder Coated) work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturer's catalogue/ instructions), cutting holes for electrical fittings fixed on and including aluminium tee of size 24mmX38mmX1.50 mm as main runner, aluminium tee of size 24mmX28mmX1.50 mm as cross runner and aluminium angle of size 24mmX24mmX1.50mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including perforated particle board/tile 12mm thick for insulation and acoustic purpose as in ceiling flat or sloping 60cmx60cm in size including necessary scaffolding all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-B, complete all as specified and as directed.
Rolled Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W (Gde- E-250) quality-A complete all as specified and directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. .
Mat finish, premium quality, joint free (edge cut), coloured/ printed Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I).
Glazed ceramic coloured tiles of size 350x 250x 7 mm/ 450X 350X 7mm mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I).
Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Rendering cement plaster 5mm thick in cement mortar 1:3 on fair faces of brick or on concrete surfaces, as in ceiling , surface finished even and smooth without using extra cement, all as specified.
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified.
Supply only intergal water proofing compound, complte all as specified.
Preperation of old plastered surfaces including complete removal of existing treatment and applying
applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties Exterior over one coat of water proof primer on walls and chajjas with 10% dilution of water including smoothing the surface with wall putty @ 2kg/ Sqm of average thickness 2mm with silicon additives and sanding these surface for removal of loose particles , complete all as specified.
Preparation of old decorated plastered or unplastered surfaces including cleaning by brooming down or with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on ceiling complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer over complete, all as specified and as directed by Engr-in-Charge Note : Work shall be executed by mechnical means
Preparation of new plastered surfaces or un plastered, previously undecorated ceiling surfaces and applying three coats of white wash, complete all as specified and directed.
Sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified.
G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches, including taking down old GI tubing complete all as specified and directed.
110mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to trenches or in floor or walls, fixed in repair complete all as specified and directed.
Sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V complete all as specified and as directed.
Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, including dismantling old tank any type, complete all as specified.
Point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable 1100 volts including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into concealed rigid non-metallic PVC conduit Med Grade ISI marked not less than 20mm wide of 1.8mm wall thickness ISI marked including modular GI sunken flush box (Pressed steel powder coated Modular GI sunken flush boxes and cover plates of any way i.e. 1 to 8 way as per site requirement suitable for modular switch/socket) for mounting switches, sockets, fan regulators etc & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed.
Modular switch 2 way 6A, 1 module, all as specified.
Modular Bell push 6A 1 module, all as specified.
Modular Socket 6A/16A - 2/3 pin combined 2 module, all as specified.
Modular Socket, 6A - 2/3 pin combined 2 module, all as specified and directed.
Bell, AC, 230 volts, single pole all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
Modular fan regulator, step type, 2 module, all as specified.
LED type tube light, 1x20 watt 230 volts wall mounted Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours, internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size. Make: Havells cat part No. LHEXACP7FN1W020 or equivalent in Appx
Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack , 10 watt LED,6500k, two feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Make: Havell's Cat Part No. LHEXACP7IN1W010 of "Havells" or equivalent in makes mentioned in Appendix
35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size to fitting including bracket made up of 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specified Make: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx
Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified.
MCB SPN 32 Amp, 240 Volts, B Curve , 10 KA all as specified.
MCB SP 6 to 32 Amp, 240 Volts, B Curve , 10 KA all as specified.
Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).
Meter box consisting space to fix MCCB as incomer and 04 Nos meter and providing 05 Nos MCB SPN 40 Amps 100mA, METER box double door fixed type wall mounted CRCA approved FACTORY MADE, 2 mm thick sheet enclosure outdoor type. The rates including taking down old DB and connecting in new panel with required wires with out any extra cost complete all as specified and directed. The panel should consists of the following :- INCOMING :- (1) MCCB 63 AMP 4 P 16 kA thermal magnetic based with o/c, s/c protection & ROH-01 No (2) Indicating lamps RYB -03 Nos OUTGOING :- (1) 40 Amp MCB SPN 100mA with enclosure -04 Nos (2) Space for refixing existing electrical meter -04 Nos. The internal wiring of panel should be of 6 sqmm from busbar to electric meter and electric meter to RCBO including a suitable size of thimbles NOTE :- (i) Contractor should visit the site and to prepare panel as per size required to fit below staircase of the bldg complete all as specified and directed by Engr-in-Charge. (ii) The rate also includes for taking down existing meter and refixing the same in Meter Panel
Supply and installing of Electric Water storage heater of ABS body type 25 Litre Capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated Mild steel tank with, glass line coating inside he tank alongwith glass line incoloy heating element with anti corrosive magnesium anode, NRV, theremostate, indicators and temperature adjustable knob including steel braided flxible connection for pipe of size 15mm dia bore GI hexagonal adopeters./ Nuts on both sides of inlet (Cold water supply) & outlet (hot water supply) and including provision of wall mouting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as dierected by Engr-in-Charge. Note : (i) Old geyser shall be deposited in MES store yard.
UNIT RATE In Figures To be entered by the Bidder Rs. P
Ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) , complete all as specified.
Mild steel galvanised iron tubing light grade for fixed on both end of wall for fixing of fan hook including cutting on wall and making good the surface , complete all as specified and directed.
Aluminum strip 25x3.15mm fixed with porcelain/PVC saddles and fixing screws etc including PVC gutties in each one metre length , for roof conductors and down conductors above ground, fixed in reapir , complete all as specified.
Air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified.
Powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilators shutter side hung type without sash bars,without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified
PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, fixed in repair, all as specified. Make: Cat Part No. 2602 of Cera or equivalent in makes mentioned in Appx .
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal .head screw all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
All as per serial item No '92' above, but for one light point controlled by two way switch all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_834516.xls
BOQ • 0.52 MB
E-tender82.pdf
Tender Documents • 1.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .