Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.4 LAccepted-Finance | ₹61.4 L | L1 | Accepted-Finance 1st lowest |
| 2 | L2₹62.0 L+₹62,597.56 (1.02%)Rejected-Finance VILL BORA P O MAMUDUPUR P S NAIHATI DIST 24 PARAGANAS NORTH PIN 743166 WEST BENGAL | NAIHATI | NORTH 24 PARGANAS | WEST BENGAL | 743166 | ₹62.0 L+₹62,597.56 (1.02%) | L2 | Rejected-Finance 2nd lowest |
| 3 | L2₹62.0 L+₹62,597.56 (1.02%)Rejected-Finance 5743 BAGUINARA ROAD BURIBATTALA SUBHASGRAM SOUTH 24 PARGANA KOLKATA 700147 | KOLKATA | SOUTH 24 PARGANA | WEST BENGAL | 700147 | ₹62.0 L+₹62,597.56 (1.02%) | L2 | Rejected-Finance 2nd lowest |
| 4 | L3₹62.6 L+₹1.2 L (2.03%)Rejected-Finance 138 PURBA PALLY KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | ₹62.6 L+₹1.2 L (2.03%) | L3 | Rejected-Finance 3rd lowest |
| 5 | L4₹63.2 L+₹1.9 L (3.04%)Rejected-Finance 1 7 SREE COLONY KOLKATA 700 092 | KOLKATA | KOLKATA | WEST BENGAL | 700092 | ₹63.2 L+₹1.9 L (3.04%) | L4 | Rejected-Finance 4th lowest |
Tender Value
₹62.0 L
EMD Value
₹1.2 L
Closing Date
20 Jan 2026, 2:00 pmClosed
Executive Engineer, KSHD, PWD
KIT Building, 2nd Floor, P-16, India Exchange Place Extension, Kolkata-700073
IPGMER-SNPH_Construction of (G plus 6) Storied Bldg for proposed Hostel Bldg at 3, Lee Road_FY_2025-26.(Civil Works)-Additional works to incorporate revised requirement i.e. modification of Gr floor to 6th floor to accommodate more number of student
2025_WBPWD_979475_1
WBPWD/KSHD/EE/NIT-43 OF 2025-2026
Open Tender
CIVIL WORKS
Percentage
90 days
Sambhu Nath Pandit Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.2 L
Yes
10 Sept 2026
29 Dec 2025
22 Jan 2026
5 Jan 2026
20 Jan 2026
5 Jan 2026
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In 1st floor including roof.
2nd floor
(A) Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth
(b) In superstructure, ground floor
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above at gr floor.
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (a) ln gr FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
125 mm thick Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I,having drying Shrinkage less than 0.05% conforming to IS: 2185 ( Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6%), lime , cement and complete in all respect as per direction & satisfaction of Engineer -in Charge . a) laid in Cement Mortar (1:6) -In Super Structure, Ground Floor.
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. i) With approved concrete pump In gr floor
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of gr floor/upto 4 m i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item vshould be executed on specific direction of the Enginner in charge). (c) steel shuttering or 9 to 12 mm thick approved quality ply board shuttering considering 7.0 m2/m3 of concrete for shuttering.
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar 20 mm thick plaster
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
With 1:6 cement mortar 15 mm thick plaster Ground floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative 2nd floor
3rd Floor
4th Floor
5th Floor
6th Floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative 2nd floor
3rd Floor
4th Floor
5th Floor
6th Floor
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (i) 32 mm thick 2nd floor
3rd Floor
4th Floor
5th Floor
6th Floor
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. (i) 66mm x 90mm
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (A) In 10-12 Micron thickness Annodizing film I) Natural white h) Louvered window. i) Top, bottom and side member.
ii) Louvered Section.
iii) Cleat angle ( Non-annodized).
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. v ) Louvered window. 2nd floor
3rd Floor
4th Floor
5th Floor
6th Floor
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 5mm thick coloured / tinted / smoke glass.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In 2nd Floor. (a) One Coat ii) Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Luxury Quality
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (e) Sal : Malayasian gr floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings In 5th Floor (a) 35 mm thick shutters (single leaf)
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
6th Floor
Supplying wooden moulding slanting beat of size 37mm X 18mm (finished) of approved design to finish the joint between wooden frame of door/window with masonary in true line and level fitted & fixed with adhesive and head less pins complete as per direction of Engineer -in-charge. a) Teak wood beat
(a) Vision aperture (round or retangular in shape) with 7.4kg. Per sq.m./ 3mm thick glass pane with wooden beads.
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. In 3rd floor. Glossy/Matt/Suede excluding surface texture or metallic lustre.(ii) Thickness of laminate 1.5 mm
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark.(viii) 100mm. X 75mm. X 3.50mm.
Iron socket bolt of approved quality fitted and fixed complete. (d) 225mm long x 10mm dia bolt.
ii) Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300mm long.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (ii) 125 mm grip x 12 mm dia rod.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.i) For roof truss works b) Span beyond 12 Mtr and up to 20.00 Mtr
Supplying, fitting & fixing 1.5mm thick Trapezoidal profile corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer in-charge including materials, labour, taxes and all other incidental charges
Scantling upto 50mm wide and 12mm thick (chamfering or rounding) for ceiling/partion battens including fitting, fixing in position with washers, coach screws etc. complete.: (b) Sishu / Champ / Badam / Gamar / Bhola / Mogra / Hallak
(i) Door stopper.(Brass)
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (e) Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m)
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (A) For Exposed Work (a) (ii) 15 mm dia. light quality
25 mm dia. medium quality
Supplying, fitting & fixing Centrifugally Cast (spun) iron soil,waste water and rain water (Hubless) pipe epoxy coated inside & outside conforming to I.S. 15905 / 2011 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (ii) 100 mm dia. (internal)
Supplying, fitting & fixing Centrifugally Cast (spun) iron (Hubless) double branch equal without door conforming to I.S. 15905 / 2011 including all joining materials but excluding coupling. (ii)b. 100 mm dia.- Y 88 D
Supplying, fitting & fixing Centrifugally Cast (spun) iron (Hubless) bend with door conforming to I.S. 15905 / 2011 including all joining materials but excluding coupling. (i) 100 mm dia.
Supplying, fitting & fixing Centrifugally Cast (spun) iron (Hubless) bend without door conforming to I.S. 15905 / 2011 including all joining materials but excluding coupling. (ii)a . 100 mm dia..- 88 degree
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (vii) 25 mm dia
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (ii) Plastic (hallow type) white
Supplying, fitting and fixing liquid soap container. (a) Cromium plated.
Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent)
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Supplying, fitting and fixing C.I. round grating. (i) 100 mm
Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(ii) Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand).
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
Add GST @ 18% on Rs. 5200351.00 i.e total amount over item no. 1 to 55
Add Labour Welfare Cess @ 1% on Rs.6136414.00
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.29 MB
Bidders43.pdf
Additional Documents • 1.50 MB
BOQ_2387458.xls
BOQ • 0.35 MB
2911.pdf
Tender Documents • 0.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .