Supply, installation, testing and commissioning of Earthing, Capacitors, Bank Contractors and ACB Accessories in Secretariat Complex, Porvorim. (II call)
2026_PWD_32013_1
31/1/2026-27/ASW-IV/EMN/PWD/30 LINE08
Open Tender
Electrical Works
Percentage
30 days
Tonca Caranzalem
Please refer to tender notice
3 documents required · 3 mandatory
₹5,000
₹12,928
25 Sept 2026
25 Sept 2026
8 Oct 2026
25 Sept 2026
6 Oct 2026
25 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20 mm Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. g)watering arrangement(plumbing will be paid seperately). | |||||
| 1.1 | '(b) In rocky strata( Masonry chamber not included) | 6 | Set | 19,209 | ₹1,15,254 |
| 2Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). | |||||
| 2.1 | d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).(b) In Rocky strata | 1 | Each | 8,020 | ₹8,020 |
| 3 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). | 1 | Set | 1,260 | ₹1,260 |
| 4 | Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt) | 6 | Set | 1,861 | ₹11,166 |
| 5 | Supply, installation, testing and commissio-ning of 3 Pole 40 Amps Contactors with 1 NO + 1 NC Aux 415 V AC Coil | 10 | No | 8,414 | ₹84,140 |
| 6 | Lighting Arrester 30KV 10KA station type | 3 | Each | 22,425 | ₹67,275 |
| 7 | Supply and laying of copper strip 50 x 5 mm. | 55 | Meter | 2,488 | ₹1,36,840 |
| 8 | Supply and laying of GI strip 50 x 6mm | 55 | Meter | 998 | ₹54,890 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 7.70 MB
BOQ_32400.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .