Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.8 L+₹99,783 (2.79%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹36.8 L+₹1.0 L (2.87%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L3 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹41 L
EMD Value
₹41 L
Closing Date
24 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
SPL REPAIR TO CERTAIN BLDGS AT OAF AND GUND HAWS SONAMARG UNDER GE 970 EWS
2021_MES_490293_1
GE 970 EWS -69/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹41 L
Yes
3 Feb 2022
25 Nov 2021
27 Dec 2021
25 Nov 2021
24 Dec 2021
10 Dec 2021
60 days
Amount
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 sqm n.exc 4 sqm each complete all as specified and directed.
Dismantiling timber scantling 40 sqcm and over insection in any position for framed work complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and paving n. exc 15cm thickness (below or above ground level) complete all as specified and directed.
Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Demolition brick work built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar roof coverings complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/blankets, any thickness any type, complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Material & labour 75 mm thick PCC 1:3:6, type C-2, using 40 mm graded aggregates as in sub base etc, finished even and fair complete all as specified and directed.
Material & labour 75 mm thick PCC 1:3:6, type C-2, using 40 mm graded aggregates as in plinth protection etc, finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for 100mm thick PCC type D-2 (1:4:8) (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed.
Material & labour for 25mm thick PCC (1:2:4) Type-B-1 (using 20mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed.
Non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the existing, over with and including 15mm thick screed bed in CM (1:4) after dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the existing, over with and including 15mm thick screed bed in CM (1:4) after dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material & labour Machine cut Kota stone slab flooring 18-20mm thick as in floor to match the shade of the slab incl rubbing and polishing laid over & including 20 mm thick screed be in CM 1:6 including roughening of Old concrete surface by picking sweeping, clean & washing down with water to remove dust and brushing with neat cement slurry with 3.0 kg / Sqm etc complete all as specified and as directed.
All as per item No.17 above but on skirting and including 10mm thick backing coat in CM 1:3 ---ditto---
2nd class hardwood plain solid, straight chowkat and frame, wrought, framed rebated (one or more rebated) on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Factory made 2nd class hard wood 35mm thick plain framed panelled shutter with lock rail and panel of 9 mm BWP commercial ply or 12 mm to 15mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated complete all as specified and directed
Factory made 2nd class hard wood 35 mm thick glazed and gauzed skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed
Material & labour Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary lugs, Butt hinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either side and back filling in PCC 1:3:6 type C-O using 12.5 mm graded crushed stone aggregate complete all as specified and directed.
Material & labour 2nd class hard wood 30 mm thick factory made glazed and gauzed skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
Material & labour 40 mm thick flush shutter solid core construction with block bord core and plywood face panels commercial type both side complete all as specified and directed.
Material & labour for box type Steel window (Factory made) outer frame made out ERW tube 'P' section 65mmx45mmx25mm and shutters of ERW tube 'P' section 50mmx35mmx20mm openable (double) shutter with glazed openable shutter on (External side) and wire gauzed openable shutters on (Internal side) with steel pintal hinges, steel handle 100mm long, mild steel tower bolt 02 Nos on each shutter , stopper of 'Z' section and its locking arrangement at mild steel hook and eye including 0.36 mm dia nominal dia of stainless steel wire cloth avg width of aperature 1.40 mm dia and 4 mm thick sheet glass window and 4 mm figured glass for ventiliators complete all as specified and directed. Note : Following items will also include in this unit rate:- (i) One shop coat of zinc chromate primer on all exposed steel surfaces and one coat tar on the ends of steel frame in contact with bricks/concrete surface. (ii) 04 Nos MS steel Lugs of 20x5mm MS flat 20cm long over all welded to frames (iii) PCC block for embedding lugs. (iv) 0.36 mm dia SS wire mesh (v) 4mm thick sheed glass - for window (vi) 4 mm thick figured glass -for vent
Material & labour 0.36 mm dia nominal dia of stainless steel wire cloth avg width of aperature 1.40 mm and fixed with SS wire staple etc complete all as specified and directed.
3mm thick sheet glass, ordinary quality glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed
Galvanized mild steel wire cloth, 0.63 mm nominal dia or wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanized wire staple complete all as specified and directed
Material & labour for 2nd class hardwood (wrought) in scantling for timber frame and fixed complete all as specified and directed.
Refixing of timber scantling obtained from dismantling complete all as specified and directed
M&L for 2nd class soft wood plain fillets exc 6 & n exc 13 Sq cm square, rectangular or triangular in section, clean sawn, se-cured with nails or brads complete all as specified and directed.
M&L for 4mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face fixed with nails to timber frame work on ceiling incl demolition of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and diredcted.
M&L for 4mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face fixed with nails to timber frame work on walls incl demolition of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and diredcted.
M&L for 20mm thick boarding, with nails in any situation (except flooring and skirting) plained both sides with butt joints incl dismantling boarding, any description, fixed in any position with nails complete al as specified and directed.
Material & labour mild steel 300mm, ordinary rat rail rod pattern springs, including roller and roller plate complete all as specified and directed.
Material & labour MS butt hinges medium weight of size 100 mm fixed with screws complete all as specified and directed.
Material & labour 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed.
Material & labour 125mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed.
Material & labour 300 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified directed.
Material & labour aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed.
Material & labour aluminium alloy handles 100 mm long fabricated type anodised complete all as specified and directed.
Material & labour preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Preparation of new steel surfaces of any description over 10cm in width and girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material & labour for cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping including necessary form work complete all as specified and directed.
Material & labour brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
Material & labour rendring 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 with and with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and smooth complete complete all as specified and directed.
Material & labour for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over a coat of primer complete all as specified and directed.
Material & labour preparing new plastered surface of walls and applying two coats of cement based paint over a coat of alkali resistant primer etc complete all as specified and directed.
Material & labour preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Anodised aluminiun snap grid frame work for false ceiling of size 605mm x 605mm with and including 6 mm thick non asbestos fibre cement building board and G.I hanger 6 mm dia (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long, complete all as specified and directed.
Material & labour pre- painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of anycolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Material & labour pre- painted galvalume aluminum zinc coated GI based plain steel sheet 0.50mm thick in ridges of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap fixed with J or L type hooks in roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed
0.80 mm thick plain galvanised, mild steel sheeting, with grade of zinc coating 275 as in ridges, hips vally gutters drip and straight flashing (length and grith as fixed) complete all as specified and directed.
Material & labour 15mm bore steel tubing, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Material & labour 20 mm bore steel tubing, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Material & labour for lagging to 15mm GI pipes used in internal water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 , provided with chicken mesh wire netting 25 gauge, 20mm mesh and with with 0.01mm aluminium foil complete all as specified and directed.
Material & labour for lagging to 20mm GI pipes used in internal water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 , provided with chicken mesh wire netting 25 gauge, 20mm mesh and with with 0.01mm aluminium foil complete all as specified and directed.
S&F in repairs 15 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specifed and directed.
S&F in repairs 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specifed and directed.
Preparation of old steel surfaces of any description over 10cm in width and girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing caping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed.
Point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLS-H) drawn through and including PVC casing and caping (ISI marked) and accessories (fixed on wall/ceiling surfaces), terminated in and including pressed steel terminal boxes with plastic laminated backlite sheet top cover 3 mm thick (hylum) fixed with nickel polished screws with washers, earth continuity PVC cable (FRLS-H), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed.
All as per description of srl item No 64 here-in-before but socket out let 3 pin, 5 Amp on independent board with other switch.
All as per description of srl item No 64 here-in-before but socket out let 3 pin, 5 Amp on same board
All as per description of srl item No 64 here in before but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 2.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin switch socket combination, 15 Amps on independent board.
All as per description of srl item No 64 here in before but using 4 sqmm (nominal area) PVC stranded copper conductor cable with 4 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin switch socket combination, 15 Amps on independent board.
Switch piano flush button single pole one way 5 A, 240 V complete all as specified and directed.
Switch socket combination 2 in 1, 5 Amp flush type, 240 V, complete all as specified and directed.
Switch socket combination 5/15A, 5 in 1, 3 pin, 240 volts complete all as specified and directed.
Ceiling rose, surface bakelite, 65 x 50 mm, three terminals, 240 volts complete all specified and as directed.
Fan regulator, electronic type, five steps socket type single phase, including connection complete all as specified and directed.
Taking down unserviceable any type of main switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
MCB DB SPN 12 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
MCB DB SPN 8 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
MCB DB SPN 4 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
MCB SPN 63 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
MCB SPN 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
LED lamp 1 x 15 watts suitable for pin type batten/pandent holder complete all as specified and directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fixing in repair energy efficient surface Mounted LED Luminire 18/20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed. Make : - Bajaj Cat No BCLSB 18 WH /NW or equivalent in Philips/CG) complete all as specified and directed.
Supply and fixing in repair 1 x 45 watts LED street light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified. (Make : Bajaj Cat No BRTFG 45W LED I or equivalent in Philips/CG) complete all as specified and directed.
Supply and fixing in repair ceiling fan with blades and down rods and accessories, 230V, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct currrent motor etc complete all as specified and directed.
Material & labour in repairs for Earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia medium grade protection pipe and salt etc and connected to earthing test point incl necessary earth work complete all as specified and directed.
Material and labour for sub main wiring in repairs with two runs of single core PVC insulated (FRLS) unsheathed copper conductor multistranded cable of size 4 sqmm 1100 volts grade drawn through in & including PVC conduit 25mm dia & 2.5 sqmm single core copper conductor multistranded PVC insulated (FRLS) unsheathed cableas earth wire continuity conductor complete all as specified and directed by Engineer in charge. Note : (i) Two run of cable 4 sqmm and one run of 2.5 sqmm earth wire shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for taking out or laying of cable in soft/loose soil and getting out compete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m where directed at a level not exc. 1.5M above the starting point complete all as specified and directed
Brick protection with brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches with width of brick parallel to the length of cable complete all as specified and directed.
Suply and fixing in repair GI tubing for cable protection light grade 40mm bore laid in trenches/fixed with pole etc complete all as specified and directed.
Supply, laying, jointing & testing under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sq mm, 3 core, aluminium conductor along with suitable size aluminium cable lugsand cable glands including taking down old unserviceable complete all as specified and directed. Note - Excavation, earthwork, sand cushioning and brick protection shall be measured and paid separately.
Supply and fixing in repair PVC insulated aluminium conductor 1100 volt grade heavy duty 10 sqmm two core fixed on walls/roof/ceilings drawn through in pipes for house service connections connecting from pole/panel to DB's etc complete complete all as specified and director
M/S RAFIQ AHMAD SOFI AND SONS
M/S RATHER CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .