REPAIRS TO SECURITY LIGHTS AND MAINTENANCE OF SOLAR STREET LIGHTS AND CONNECTED WORKS ALONG THE PERIMETER AT AFA HYDERABAD
2021_MES_423490_1
8133/02/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AFA) Hyderabad
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹40,000
Yes
7 Apr 2021
18 Feb 2021
22 Mar 2021
18 Feb 2021
20 Mar 2021
6 Mar 2021
18 Feb 2021 - 2 Mar 2021
Amount
Attending day to day maintenance on requirment basis for checking the serviceability / repairing all Security lights , including disconnecting and taking down unserviceable all type of light fitting (LED/HPSV/MH/CFL fittings etc.) of any type and make complete from the PCC Pole / Steel tubular poles / Watch Towers along the perimeter (Appx 45 Kms long), including repairs to unserviceable wiring, connectors at pole junction boxes / connecting from OH lines to light fittings, minor supplying of spares like holders, connectors, screws washers etc and reconnecting / refixing and testing complete all as directed.
Note:- (i) Necessary defective spares which are required to be replaced to make proper functioning of all type security lights, shall be measured and paid seperately under relevent items as directed by Engr-in Charge.
(ii) Contractor will have to provide well experienced 1 No Electrician with 1 No Helper along with vehicle, tools and ladder etc for checking the serviceability/repairing on requirement basis (for 8 Hrs only) in addition to man power required for execution of other routine works.
(iii) All Tools & Plants required for repair work shall be provided / arranged by the contractor at his own arrangement and expense to the trade men & helpers also include in the quoted rate.
(iv) All complaints should be attended with in 24 hours of reporting of complaints. Penalty charges for non attending complaints with in 24 hrs shall be Rs 300/- per complaint .
(v) A joint inspection for checking of serviceability of security lights will be carried out with contrator's representative, user's representative and MES personal in every week.
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 1x 30 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTS-30-CDL-M/ Havells(ENDURAPEARLSL30WLED757SASYTOPCMP)/ Luker(LSTE30) /Bajaj(BRLEP30WLED WH)
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 1 x 45-48 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTS-45-CDL-M/ Havells(ENDURAPEARLNEOSL45WLED757PASYTOPC)/Luker(LST48) /Bajaj(BRLEP45WLED V2)
Taking out the existing unserviceable street light fittings any type and S&F LED Street light fitting 70-72 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make: Crompton(LSTP-72-CDL-M/ Havells(ENDURACITYLINERNEOOSL70WLED757PASYBOTG)/Luker(LST72) /Bajaj(BRLEP72WLED V2)
S & F LED flood light fittings 50 watt LED pressure die cast aluminium housing heat resistant toughned glass with frame , IP-66 protection , uniform distribution , including taking out the existing fully rusted unserviceable complete all as specified and as directed . Make: Crompton(LFL-50-CDL/60-M/ Havells(JETAQUANTOPLUSFLP50WLED757SYMLENS)/Luker(LFL50SEN) /Bajaj(BJFL50WLED I )
S & F LED flood light fittings 150 watt LED pressure die cast aluminium housing heat resistant toughned glass with frame , IP-66 protection , uniform distribution , including taking out the existing fully rusted unserviceable fitting complete all as specified and as directed . Make: Crompton(LFLN-150-CDL/60-M/ Havells(JETAIRISFLS150WLED757PSYMLTG)/Luker(LFLSL150) /Bajaj(BJFL150WLED I )
S &F of electronic driver for LED street light upto 30 watt incl takingout unserviceable driver complete all as directed. Note :- Driver will be procured as per sample, as required at site compatable for existing light fittings Make : Crompton/Havells /Wipro/Bajaj/Luker/Philips
S & F of electronic driver for LED street light 45 / 50 watt incl takingout unserviceable driver complete all as directed. ote :- Driver will be procured as per sample, as required at site compatable for existing light fittings Make : Crompton/Havells /Wipro/Bajaj/Luker/Philips
S & F of electronic driver for LED street / flood light 70 to 150 watt incl takingout unserviceable drivercomplete all as directed. ote :- Driver will be procured as per sample, as required at site compatable for existing light fittings Make : Crompton/Havells /Wipro/Bajaj/Luker/Philips
M&L for repairing of Electronic chip, suitable for LED Street light upto 20/25/30 watt capacity, by replacing faulty electronic components to make the light fitting serviceable complete all as specified and as directed Note :- Chip will be procured as per sample, as required at site compatable for existing light fittings
M&L for repairing of Electronic chip, suitable for LED Street light upto 45/50/60 watt capacity, by replacing faulty electronic components to make the light fitting serviceable complete all as specified and as directed Note :- Chip will be procured as per sample, as required at site compatable for existing light fittings
S & F of Surge Protection Device for LED street/flood light rated power above 75W upto 150W incl takingout unservieable surge protection complete all as directed. Note :- Note :- Surge Protection Device will be procured as per sample, as required at site compatable for existing light fittings
Excavation in trenches in soft / loose soil not exc 1.5 m wide and not exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables pipes, ploles, foundation etc complete all as specified and as directed.
Excavation in trenches in hard / dense soil not exc 1.5 m wide and exc 1.5 m but not exc 3.0 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables/Poles pipes/foundation etc complete all as specified and as directed.
M&L for Dry River sand for cushioning of UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned down up to 18 cm thick and consolidation, complete all as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind soil in largers n.exc. 25 cm thick after laying of cables including spreading, levelling, and well ramming complete all as specified and as directed.
Re laying of old retreived bricks obtained from excavation in trenches of exisitng laid cables complete all as specified and as directed.
M&L for bricks sub class B locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Supply, laying & testing XLPE UG insulated cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 35 sqmm 3.5 core with necessary lugs and glands including dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex/ Gloster/ICC/CCI
Supply, laying & testing XLPE UG insulated cable 1100 volts grade, armoured conforming to relevant IS specifcations with aluminum conductor of size 25 sqmm 3.5 core with necessary lugs and glands including dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex/Gloster/ICC/CCI
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 16 sqmm 4 core with necessary lugs and glands including dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex/Gloster/ICC/CCI
Supply, laying & testing XLPE UG insulated cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 10 sqmm 4 core with necessary lugs and glandsincluding dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex/Gloster/ICC/CCI
Supply, laying & testing XLPE UG insulated cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 10 sqmm 2 core with necessary lugs and glands including dismantling and taking out the unserviceable cable all as directed. Make :- Havells/ Polycab / Finolex/Gloster/ICC/CCI
M&L for light grade galvanized pipe ISI marked with necessary fitting ISI marked, laid in trenches, under road or fixed on wall/pole/ crossing nallah etc of bore 50 mm complete all as specified and as directed .
M&L for light grade galvanized pipe ISI marked with necessary fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 40 mm complete all as specified and as directed .
Boring of holes under road, pavement hard standing by using trenchless technology using ultrasound technique and necessary machine to insert pipe of 50 to 100mm light grade GI pipes as per site requirement with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, alongwih Butt fusion welding machine with all accessories, T&P etc required all as specified and as directed. Note :- Protection pipe will be measured and paid separately
M&L for straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 16 to 35 sqmm 3.5/4.0 core and testing complete all as specefied and as directed.
M&L for Re Stringing and Fixing only in position of sagged ACSR conductor of required size in over head line including binding with aluminium binding wire complete after removing and refixing of UG cables/services wires to the ACSR conductor complete all as specified and as directed by the Engr-in-charge Note : Three phase and one neutral i.e four conductor will be measured in one span.
S & F PVC LT line separators 4 way with nut, bolt arrangement, in the existing O/H line on pole of height 7.0-7.50 mtrs above ground level conductor complete all as specified and as directed .
Trimming of trunk and branches of trees not exceeding 30 cm grith and disposal of the same to a distance n.exc 50m and clearing site complete all as directed to clear the OH line (HT/LT) for a span irrespective of length. complete all as specified and as directed .
M&L for Cutting of Vegetations, creapers, grasses, earth heaps etc, cleaning and levelling of cutting areas in various electrical installation areas, surrounding of HT/LT poles/structures complete all as specified and as directed .
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping to pole for embedding stay road all as specified, including necessary form work and applying two coats of white wash to exposed surface of coping / platform complete all as specified and as directed .
M&L for PCC 1:3:6 type C-2 mix using 40 mm graded stone aggregate for foundation / platform / pedestal / stay wire etc, complete all as specified and as directed .
S & F cable junction box 167 x 125 x 82 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, unts, bolts, washers etc., including taking out of old unserviceable cable junction box complete all as specified and as directed Make Cat No . D-9100 of HENSEL or equivalent in SPELSBERG / RITTAL/SINTEX
M&L GI tubing light grade 20 mm bore for protection of service connection for protection of connection wire from junction box to street light fittings ( Note : Necessary clamps, nuts, bolts etc deemed to be included)
M&L for cable two core PVC insulated, PVC sheathed multi stranded aluminium conductor cable size 2.5 Sqmm for connection junction box to security light complete all as specified and as directed .
Removing the existing unserviceable GI pipe bracket along with clamps and supply and fix GI pipe light grade bracket 40 mm dia, 1.2 mtr long bent to shape as required and fixed with suitable size of MS clamps, (40 mm x 5 mm MS Flat) nut, bolt, washers etc to poles/walls complete all as directed.
M&L for Painting to the existing cross arms /clamps / bracings/ nuts bolts and washers complete with two coats of Aluminium paint after cleaning the surfaces the metal at height of 7 to 8.5 mtrs pole above ground level with out disturbing the conductors completely and making good complete all as specified and as directed
S&F all in one integrated Solar Smart LED Street light fitting 30 Watt, Solar panel of 6V 12W Polycrystalline type should be on the top of the fitting with Lithium- Ferrous Battery of 24 AH , pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution including suitable GI pipe bracket, complete all as specified and as directed. Make:- Luker/Havells/Bajaj/CG/Philips
Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32 x 6 mm as earth lead by means of brazing etc all as shown in electrical plate No 3 connected to earthing test point as specified or indicated including testing on completion. Note:- (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. 3) All the joints should be brazed only brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed ..
M&L for Repairing of Street Light Timer Panels Indoor /Outdoor type 415Volts,50Hz including replacement of Spare parts and all as directed by Engineer-In-Charge. Note: Spare parts will be measured and paid separately under relavent item No.43 to 53
(i) Checking/Overhauling/repairing of MCCB 4 pole 63 Amps to 120Amp, 25 KA, 415 Volts, 50 HZ, AC supply, - 01 Nos(Incoming)
(iv) Checking/repair/replacement of Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply - 01 No
(v) Checking/repair/replacement of 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No
(vi) Checking/repair/replacement of LED indicating lamps with holder for main supply - 1 Set of 3 (R-Y-B)
Supply only MCCB 4 pole 63 Amps, 25 KA, 415 Volts, 50 HZ, AC supply Make: Havells (IHLASFOO63) or equivallent in /L&T/C&S
Supply onlyMCCB 4 pole ,125Amp, 25 KA, 415 Volts, 50 HZ, AC supply Make: Havells (IHLASFO125) or equivallent in /L&T/C&S
Supply only Voltmeter digital type,0-500V,AC, 96x96mm Make; AE/MECO/L&T
Supply onlyAmmeter digital type,CTR 5A, 96x96mm Make; AE/MECO/L&T
Supply onlyCT's 63/5Amps Class 1 accuracy-01Set
Supply onlyCT's 120/5Amps Class 1 accuracy-01Set
Supply only Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply Make :.L&T/GIC/LegrandL&T/GIC/Legrand
Supply only of 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No Make:L&T//Havells/C&S
Supply only LED ,230Volts AC indicating lamps with holder for main supply (R-Y-B) Make: Teknic/C&S/L&T
RAJU ENTERPRISES
RAJU AND CO
POWER CONSTRUCTION COMPANY
Srinivasa Consructions
Pragathi Infrastructure Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .