Provision of CCTV at 21 nos. of Non interlocking LC Gates and monitoring at 13 nos. of connected station and Engineering control over Bhopal Division.
BPLNWKS2026-27TELE02
BPLNWKS2026-27TELE02
Open
Works - General
6 Months
Bhopal, Madhya Pradesh
₹0
₹3.1 L
10 Jul 2026
10 Jul 2026
22 Jul 2026
01-Schedule A (Supply)
02-Schedule B (Execution)
Item Breakup - 01-Schedule A (Supply)
Supply, Installation, Testing and Commissioning Numbers of Full HD Fixed Bullet type IP Colour Camera along with 128 GB or Higher SD Card, housing and mount and all accessories required for installation purposes per RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0 with amdt. 1,2 & 3 or latest. Inspection Authority: RDSO BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
Supply, Installation, Testing and Commissioning Numbers of Full HD Fixed Dome type IP Colour Camera along with 128 GB or Higher SD Card, Housing & Mount and all accessories required for installation purposes as per RDSO Spec No. RDSO/SPN/TC/65/2021, Rev 6.0 with amdt. 1,2 & 3 or latest. Inspection Authority: RDSO
Supply of 32 Channel Network Video Recorder Numbers (NVR) with all accessories as per RDSO spec. No.RDSO/SPN/TC /65/2021, Rev 6.0 with amdt. 1,2 & 3 or latest. Inspection Authority: RDSO
Supply, Installation, testing and commissioning Numbers of 8 port POE manageable field switch with two fibre ports(1G SFP loaded)as per RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0 or latest with amdt. 1,2 & 3 or latest. (Switches to be procured from TTP approved sources) Inspection Authority: RITES.
Supply, Installation, Testing and Commissioning Numbers of VMS Server with all the accessories required for the installation for VSS project, including one 17 inch FHD Monitor with Keyboard, Mouse, KVM Switch, As per RDSO Spec No RDSO/SPN/TC/65/2021, Rev 6.0 with amdt. 1,2 & 3 or latest.. Inspection Authoruty: RDSO
Supply Installation, Testing and Commissioning Numbers of Software for VMS and Video Recording software. (Per camera License means Video Management and Video Recording at multiple locations such as Station, RPF Post & DC Server room covered by the same license) as per RDSO Spec No RDSO/SPN/TC/65/2021 Rev.6 with amdt. 1,2 & 3 or latest. Inspection Authority: RDSO.
Supply, Installation, Testing and Commissioning Numbers of Graphical User Interface based Client Software as per RDSO Spec No RDSO/SPN/TC/65/2021 Rev.6 with amdt. 1,2 & 3 or latest. Inspection Authority: RDSO
Supply Installation Testing and Commissioning Numbers of PC Work Station suitable for Viewing, Monitoring and System Management as per RDSO Spec No RDSO/SPN/TC/65/2021, Rev.6.0 with amdt. 1,2 & 3 or latest. Inspection Authority: RDSO
Supply of Data Card with available SIMs Numbers operator Reliance/JIO/Airtel/ Idea etc. as decided by site incharge as per site condition, SIMs should be recharged with sufficient data Pack till the completion of maintenance period. Inspection authority: Consignee.
Supply of HDPE duct 40/33 mm as per Metre RDSO/SPN/TC/ 45/2013 Rev.2.0 with amdt. 3.0 or latest. For each KM of HDPE duct following items are to be supplied a) End plugs-2 nos. b) Cable sealing plugs-2 nos. c) Plastic couples slip fit/push fit b type-2 nos. d) End plugs to be provided along with drum-2 nos. Inspection authority :Consignee.
Supply of STP Cat 6 cable it should be compliant Metre with latest EIA/TIA-568-B.2-1 standard, Make-D- link/Syrotech/Digisol or similar. Inspection authority :Consignee
Supply Seagate/Toshiba/WD or similar. Inspection authority: Consignee.
Supply of HDMI cable of 10 Mtr. length. Make: Numbers Extron, D-link, Kramer or similar. Inspection authority: Consignee BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
Supply of patch chord 3 meter long of CAT6 UTP Numbers Cable factory crimped. Make: D-link, syrotech, Digisol or similar. Inspection authority: Consignee.
Supply of All in One PC with 23.8 Inch Display/ Numbers Windows having minimum specification Resolution: 1920 x 1080 Pixels or better, Processor Type: Core i5 or better, RAM Size: 16 GB, Hard Disk Description: 512 GB, SSD 5th generation, Operating System: Windows 11 Home or higher, MS office: Preloaded office- 2021 or latest, Warranty: 1 Years . Note: All in one PC should be compitable with server and all supporting software should be installed for Viewing/ monitoring of live feed of camera at station. Inspection authority: RITES
Supply of LED Monitor 19 inch or higher for Numbers Viewing/ monitoring of live feed of camera at LC gate with all accessories including wall mounting arrangement with suitable wall-mount bracket, fasteners and associated materials, Monitor should be housed in mettakic cage, Make: DELL,Lenovo, LG, intex or similar. It should be compatible with NVR. Inspection Authority: Consignee.
Supply Installation of Full HD Large Format Numbers Display Monitor (55 inch) as per RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0 or latest with amdt. 1,2 & 3 or latest. Inspection Authority: RITES
Supply & Installation of 9U Rack with hinge door Numbers cooling fan, 5 Socket power extension board, cable manager, partition tray and accessories with locking arrangement on both door and wall mount arrangement. Make- Comrack, Rittel, APW, HCL, D- LINK or similar. Inspection Authority:RITES.
Supply of on-line UPS 1 KVA with battery backup Numbers 60 minutes with minimum spec. are as under: Technology: IGBT-PWM. Input Power: 210-220 volt, sinewave: 50Hz, out power: Single phase 230Volt, warranty: 3 years. Make/Brand: APC, Luminous, AMCO or similar. (Inspection authority: RITES)
Supply, Installation, testing and commissioning Numbers of UPS 5KVA capacity with battery bank for 1 hrs (Online ) at rated load & battery trolley as per specification no RDSO/PE/SPEC /PS/0023(ReV. '0') 2001 Amdt 4 or latest. (Inspection Authority: RITES)
Supply and fixing of PVC casing caping 25mm (1 Metre inch) with all accessories. This includes drawing/laying of telecom cables/ OFC/ Power cable through casing capping and termination of wire at end point and work should be carried out as per the instruction of Railway site engineer. (Inspection authority: Consignee)
Supply, installation, testing and commissioning Numbers of Solar power plant with 2 KWp Solar PV Panel, Mono PERC, 550 Wp, 24 V string configuration, 2.7 kWp total (5 x 540 Wp) BIS, ALMM approved, Solar Batteries bank 12 V, 4*200 Ah (Tubular Lead Acid), Solar Inverter (Hybrid) 24 VDC input, 1.5 kVA / 24 V, Pure Sine Wave with inbuilt MPPT charge controller including Cables (DC/AC), MCBs, Fuses, Connectors, Earthing, Mounting Structure. (Inspection authority :RITES) BHOPAL DIVISION-S AND T/WEST CENTRAL RLY
Supply and installation of of Air Fiber with one Numbers Time installation Charges for Air Fiber with available network as decided by site incharge as per site condition,Air fiber should be recharged with sufficient data Pack till the completion of maintenance period. (Inspection authority: Consignee) Total 8999612.64
Item Breakup - 02-Schedule B (Execution)
Excavation of trench as per cable route plan 1.2 Metre mtr deep, 300 mm wide at the bottom along main line in normal soil. This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately clearing of route, bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then their shall be the proportionate payment be made to the contractor.
Track crossing, Road crossing by pushing Metre method (HDD method) at culvert/Railway track/ Pucca road/Kuccha road at a depth not less than 1 mtr with reference to bottom of rail/ road surface including supply of GI/HDPE pipe.GI pipe with 76 mm dia, Spec No. 1239 medium grade (for the length of pushing more than 05 meters). The work is to be executed as per instruction of Railway Site Engineer.
Laying of various cables as per the approved Metre cable route plan in the excavated trench, inside GI, DWC pipes etc. and inserting the cable in building taking due care while transporting and laying. The cable are to be laid as per extant practice of West Central Railway and as per instructions of Engineer.
Transportation and laying of HDPE pipe as per Metre approved cable route plan in the excavated trench taking due care while transporting and laying the same in the tranches or other protective works. Both the end of duct should be sealed with end plugs before laying.
Recharge of 02 numbers of SIMs provided for Year data cards at each LC gate (21 nos. LC Gate), with 45 GB data per month per SIM (or as per requirement) provided through this work , for a period of 05 years. (Inspection authority :Consignee)
Recharge of AirFiber connectivity installed at Year each LC Gate (21 nos. LC Gate) through this work for a period of 05 years.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022forWC_compressed.pdf GCC April 2022
ATTACHMENT
TenderBooklet_merged6.pdf
ATTACHMENT
GCCACS1to11_compressed.pdf
ATTACHMENT
AnnexureVI-B.pdf
ATTACHMENT
MII_Revision_Order_19July2024.pdf
ATTACHMENT
GCCApril2022forWC_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].