Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.3 LAccepted-AOC H NO 1044 MASTER COLONY BRAHAMPURI MEERUT | MEERUT | UTTAR PRADESH | 245206 | ₹2.3 L | L-1 | Accepted-AOC ok |
| 2 | L-2₹2.4 LRejected-Finance | ₹2.4 L | L-2 | Rejected-Finance Higher Rate |
| 3 | L-3₹2.4 LRejected-Finance | ₹2.4 L | L-3 | Rejected-Finance Highest Rate |
| Sl No | Description | Qty | Unit | DHAANI POWER L3 | J.J. CONSTRACTION L2 | TEEKA RAM CONTRACTOR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Patrolling of entire stretch of 33 KV Bhola-Kankerkhera Line of 13 Km. | 14 | Job | 1,800 ₹25,200 | 1,770 ₹24,780 | 1,740 ₹24,360 |
| 2.00 | Trimming of trees along 33 KV line | 12 | K.m | 1,425 ₹17,100 | 1,400 ₹16,800 | 1,370 ₹16,440 |
| 3.00 | Excavation of hole / pit & placing stone pad Erection of single Pole STP- 13/11 Mtr. Concreting with 1:4:8 Cement Concrete and back filling and fitting of V-type Cross Arm, F-bracket, all Clamps, Nut & Bolts, Pin Insulators with Pins, Wrapping of Barbed Wire (2 Kg.), painting with surface preparation etc., Cartage, Civil Material, Labour and T&P required for completion of work. | 2 | Nos. | 10,220 ₹20,440 | 10,100 ₹20,200 | 10,050 ₹20,100 |
| 4.00 | Laying, lifting, stringing and proper sagging of loose 33 KV line spans on ACSR raccoon conductor with opening the binding from the insulators and rebinding after proper sagging. | 500 | Mtr. | 7.8 ₹3,900 | 7.65 ₹3,825 | 7.55 ₹3,775 |
| 5.00Straightening of 11 mtrs.long tilted supports of 33 KV line as follow (3 Nos.):- | ||||||
| 5.01 | (i) Binding of gye ropes in the pole in four sides of 11 mtr. Long pole and manually holding in straight position to avoid its falling | 1 | Job | 670 ₹670 | 650 ₹650 | 625 ₹625 |
| 5.02 | (ii) Digging of pit of proper size approx.2.00 mtr. Deep and 2.00 mtr. Wide and making the pole straight and resetting of 33 KV X-arms in proper alignment with opening/refixing the same.Filling the pit and properly ramming of earth into pit | 1 | Job | 1,945 ₹1,945 | 1,900 ₹1,900 | 1,865 ₹1,865 |
| 5.03 | Grouting of supports in ratio 1:4:8 in cement,C. sand & stone ballast in a block of 0.45 X 0.45 X 1.00 mtr. Including cost of all civil material, shuttering, labour, cartage etc. | 1 | Job | 920 ₹920 | 880 ₹880 | 860 ₹860 |
| 5.04 | Making cylindrical plinths of the support around the pole in ratio 1:4:8 in cement, C.sand & stone ballast and plastering in 1:4 of 12 mm thick complete in all respect | 1 | Job | 730 ₹730 | 700 ₹700 | 660 ₹660 |
| 6.00 | Replacement of damaged, old, flash over 33 KV Pin insulators & Pin with nuts at various places along the line | 20 | Nos. | 730 ₹14,600 | 700 ₹14,000 | 660 ₹13,200 |
Tender Value
Refer Docs
EMD Value
₹4,700
Closing Date
16 May 2026, 4:00 pmClosed
Executive Engineer
195, Patel Nagar, New Mandi, Muzaffarnagar
Annual Rate Contract for maintenance (Breakdown / Shutdown) of 33 KV Bhola-Kankerkhera line under EGD, Muzaffarnagar.
2026_UPJVN_1138980_1
T-01/EGD/MZN/2026-27
Open Tender
Miscellaneous Works
365 days
Muzaffarnagar
As per PQC
2 documents required · 2 mandatory
₹354
U P Rajya Vidyut Utpadan Nigam Ltd
₹4,700
5 Jun 2026
18 Apr 2026
18 May 2026
18 Apr 2026
16 May 2026
18 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
Patrolling of entire stretch of 33 KV Bhola-Kankerkhera Line of 13 Km. | - | Job | - | - | BI01010001010000000000000515BI0100001113 | |
Trimming of trees along 33 KV line | - | K.m | - | - | BI01010001010000000000000515BI0100001114 | |
Excavation of hole / pit & placing stone pad Erection of single Pole STP- 13/11 Mtr. Concreting with 1:4:8 Cement Concrete and back filling and fitting of V-type Cross Arm, F-bracket, all Clamps, Nut & Bolts, Pin Insulators with Pins, Wrapping of Barbed Wire (2 Kg.), painting with surface preparation etc., Cartage, Civil Material, Labour and T&P required for completion of work. | - | Nos. | - | - | BI01010001010000000000000515BI0100001115 | |
Laying, lifting, stringing and proper sagging of loose 33 KV line spans on ACSR raccoon conductor with opening the binding from the insulators and rebinding after proper sagging. | - | Mtr. | - | - | BI01010001010000000000000515BI0100001116 | |
Straightening of 11 mtrs.long tilted supports of 33 KV line as follow (3 Nos.):- | - | - | - | - | - | |
| 5.01 | (i) Binding of gye ropes in the pole in four sides of 11 mtr. Long pole and manually holding in straight position to avoid its falling | - | Job | - | - | BI01010001010000000000000515BI0100001117 |
| 5.02 | (ii) Digging of pit of proper size approx.2.00 mtr. Deep and 2.00 mtr. Wide and making the pole straight and resetting of 33 KV X-arms in proper alignment with opening/refixing the same.Filling the pit and properly ramming of earth into pit | - | Job | - | - | BI01010001010000000000000515BI0100001118 |
| 5.03 | Grouting of supports in ratio 1:4:8 in cement,C. sand & stone ballast in a block of 0.45 X 0.45 X 1.00 mtr. Including cost of all civil material, shuttering, labour, cartage etc. | - | Job | - | - | BI01010001010000000000000515BI0100001119 |
| 5.04 | Making cylindrical plinths of the support around the pole in ratio 1:4:8 in cement, C.sand & stone ballast and plastering in 1:4 of 12 mm thick complete in all respect | - | Job | - | - | BI01010001010000000000000515BI0100001120 |
Replacement of damaged, old, flash over 33 KV Pin insulators & Pin with nuts at various places along the line | - | Nos. | - | - | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_2126580.xls
BOQ • 0.24 MB
TechnicalSpecificationT01Line.pdf
Tender Documents • 1.12 MB
Download all tender documents and submit your bid