Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.3 LAccepted-AOC H NO 1044 MASTER COLONY BRAHAMPURI MEERUT | MEERUT | UTTAR PRADESH | 245206 | ₹2.3 L | L-1 | Accepted-AOC ok |
| 2 | L-2₹2.4 LRejected-Finance | ₹2.4 L | L-2 | Rejected-Finance Higher Rate |
| 3 | L-3₹2.4 LRejected-Finance | ₹2.4 L | L-3 | Rejected-Finance Highest Rate |
| Sl No | Description | Qty | Unit | DHAANI POWER L3 | J.J. CONSTRACTION L2 | TEEKA RAM CONTRACTOR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Patrolling of entire stretch of 33 KV Bhola-Kankerkhera Line of 13 Km. | 14 | Job | 1,800 ₹25,200 | 1,770 ₹24,780 | 1,740 ₹24,360 Lowest |
| 2.00 | Trimming of trees along 33 KV line | 12 | K.m | 1,425 ₹17,100 | 1,400 ₹16,800 | 1,370 ₹16,440 Lowest |
| 3.00 | Excavation of hole / pit & placing stone pad Erection of single Pole STP- 13/11 Mtr. Concreting with 1:4:8 Cement Concrete and back filling and fitting of V-type Cross Arm, F-bracket, all Clamps, Nut & Bolts, Pin Insulators with Pins, Wrapping of Barbed Wire (2 Kg.), painting with surface preparation etc., Cartage, Civil Material, Labour and T&P required for completion of work. | 2 | Nos. | 10,220 ₹20,440 | 10,100 ₹20,200 | 10,050 ₹20,100 Lowest |
| 4.00 | Laying, lifting, stringing and proper sagging of loose 33 KV line spans on ACSR raccoon conductor with opening the binding from the insulators and rebinding after proper sagging. | 500 | Mtr. | 7.8 ₹3,900 | 7.65 ₹3,825 | 7.55 ₹3,775 Lowest |
| 5.00Straightening of 11 mtrs.long tilted supports of 33 KV line as follow (3 Nos.):- | ||||||
| 5.01 | (i) Binding of gye ropes in the pole in four sides of 11 mtr. Long pole and manually holding in straight position to avoid its falling | 1 | Job | 670 ₹670 | 650 ₹650 | 625 ₹625 Lowest |
| 5.02 | (ii) Digging of pit of proper size approx.2.00 mtr. Deep and 2.00 mtr. Wide and making the pole straight and resetting of 33 KV X-arms in proper alignment with opening/refixing the same.Filling the pit and properly ramming of earth into pit | 1 | Job | 1,945 ₹1,945 | 1,900 ₹1,900 | 1,865 ₹1,865 Lowest |
| 5.03 | Grouting of supports in ratio 1:4:8 in cement,C. sand & stone ballast in a block of 0.45 X 0.45 X 1.00 mtr. Including cost of all civil material, shuttering, labour, cartage etc. | 1 | Job | 920 ₹920 | 880 ₹880 | 860 ₹860 Lowest |
| 5.04 | Making cylindrical plinths of the support around the pole in ratio 1:4:8 in cement, C.sand & stone ballast and plastering in 1:4 of 12 mm thick complete in all respect | 1 | Job | 730 ₹730 | 700 ₹700 | 660 ₹660 Lowest |
| 6.00 | Replacement of damaged, old, flash over 33 KV Pin insulators & Pin with nuts at various places along the line | 20 | Nos. | 730 ₹14,600 | 700 ₹14,000 | 660 ₹13,200 Lowest |
Tender Value
Refer Docs
EMD Value
₹4,700
Closing Date
16 May 2026, 4:00 pmClosed
Executive Engineer
195, Patel Nagar, New Mandi, Muzaffarnagar
Annual Rate Contract for maintenance (Breakdown / Shutdown) of 33 KV Bhola-Kankerkhera line under EGD, Muzaffarnagar.
2026_UPJVN_1138980_1
T-01/EGD/MZN/2026-27
Open Tender
Miscellaneous Works
Item Wise
365 days
Muzaffarnagar
As per PQC
2 documents required · 2 mandatory
₹354
U P Rajya Vidyut Utpadan Nigam Ltd
₹4,700
5 Jun 2026
18 Apr 2026
18 May 2026
18 Apr 2026
16 May 2026
18 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Patrolling of entire stretch of 33 KV Bhola-Kankerkhera Line of 13 Km. | - | Job | - | - |
| - | Trimming of trees along 33 KV line | - | K.m | - | - |
| - | Excavation of hole / pit & placing stone pad Erection of single Pole STP- 13/11 Mtr. Concreting with 1:4:8 Cement Concrete and back filling and fitting of V-type Cross Arm, F-bracket, all Clamps, Nut & Bolts, Pin Insulators with Pins, Wrapping of Barbed Wire (2 Kg.), painting with surface preparation etc., Cartage, Civil Material, Labour and T&P required for completion of work. | - | Nos. | - | - |
| - | Laying, lifting, stringing and proper sagging of loose 33 KV line spans on ACSR raccoon conductor with opening the binding from the insulators and rebinding after proper sagging. | - | Mtr. | - | - |
| - | Straightening of 11 mtrs.long tilted supports of 33 KV line as follow (3 Nos.):- | - | - | - | - |
| 5.01 | (i) Binding of gye ropes in the pole in four sides of 11 mtr. Long pole and manually holding in straight position to avoid its falling | - | Job | - | - |
| 5.02 | (ii) Digging of pit of proper size approx.2.00 mtr. Deep and 2.00 mtr. Wide and making the pole straight and resetting of 33 KV X-arms in proper alignment with opening/refixing the same.Filling the pit and properly ramming of earth into pit | - | Job | - | - |
| 5.03 | Grouting of supports in ratio 1:4:8 in cement,C. sand & stone ballast in a block of 0.45 X 0.45 X 1.00 mtr. Including cost of all civil material, shuttering, labour, cartage etc. | - | Job | - | - |
| 5.04 | Making cylindrical plinths of the support around the pole in ratio 1:4:8 in cement, C.sand & stone ballast and plastering in 1:4 of 12 mm thick complete in all respect | - | Job | - | - |
| - | Replacement of damaged, old, flash over 33 KV Pin insulators & Pin with nuts at various places along the line | - | Nos. | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_2126580.xls
BOQ • 0.24 MB
TechnicalSpecificationT01Line.pdf
Tender Documents • 1.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].