Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.9 LAccepted-AOC | ₹29.9 L Quoted ₹30.8 L | 1 | Accepted-AOC L1 |
| 2 | 2₹31.6 L+₹78,731 (2.55%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹31.6 L+₹78,731 (2.55%) | 2 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 3 | 3₹31.7 L+₹92,156 (2.99%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹31.7 L+₹92,156 (2.99%) | 3 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 4 | 4₹32.7 L+₹1.9 L (6.18%)Rejected-Finance | ₹32.7 L+₹1.9 L (6.18%) | 4 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 5 | 5₹32.8 L+₹2.0 L (6.58%)Rejected-Finance | ₹32.8 L+₹2.0 L (6.58%) | 5 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
21 Feb 2022, 6:00 pmClosed
GE AF Udhampur
AF STN UDHAMPUR
CERTAIN REPAIR TO LT UNDERGROUND CABLES, REPLACEMENT OF OVER HEAD CONDUCTORS AND AB CABLES INCLUDING JOINTING KITS AT VARIOUS LOCATIONS AT AF STATION UDHAMPUR
2021_MES_488408_2
GE/AFU-44/2021-22
Open Tender
Miscellaneous Works
Item Rate
334 days
AF STATION UDHAMPUR
Refer tender documents
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹80,000
Yes
12 Apr 2022
31 Jan 2022
23 Feb 2022
31 Jan 2022
21 Feb 2022
7 Feb 2022
1 Feb 2022 - 5 Feb 2022
Amount
Excavation in trenches in any type of soft / hard soil, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation / laying of pipes and getting out complete all as specified and as directed.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
M & L for Sand cushioning for 8 cm before laying the cable and then after laying the cable 15 cm width of trenches for protection of cables including punning down complete all as specified and as directed. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Supply and fixing of Brick tiles common burnt clay building /ducts bricks’ sub-class `B’ Designation 75 (230mmx115mmx75mm) complete all as specified and as directed
Taking out old unserviceable GI tubing and S&F 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and as directed by Engr-in-Charge.
Taking out old unserviceable GI tubing and S&F 50 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable GI tubing and M&L new GI tubing 40mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified.
Painting to steel tubular swaged poles 9/11 mtr long complete (except above the perimeter wall portion) including all MS work mounted on pole, earth protection & with pipe (if exists) with one coat of aluminium paint and synthetic enamel paint from top of perimeter wall / PCC coping and numbering of poles with white synthetic enamel paint on black back ground complete all as specified and directed by Engr-in-Charge
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed by Engr-in-CHarge of following sizes :- Note Item No 10.01 to Item No 10.09. Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles, Clamps, fastner,nut,bolt and washers etc rates shall deemed to be included in the quoted rates). Make- Havells/Gloster/Polycab
Cable size 10 sqmm 4 core
Cable size 16 sqmm 4 core
Cable 25 sqmm 3.5 core
Cable size 35 Sqmm 3.5 core complete
Cable 50 sqmm 3.5 core complete
Cable 95 sqmm 3.5 core complete
Cable 120 sqmm 3.5 core complete
Cable 150 sqmm 3.5 core complete
cable 185 sqmm 3.5 core complete
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V,thermal magnatic load, ICS = 100% of ICU, 63 Amps with breaking capacity 16 KA including all accessories complete all as specified and as directed Make Schneider, cat part No LV510315 L/Havells/L&T/Standard/ Legrand or equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, thermal magnatic load, ICS 100% of ICU, 100 Amps with breaking capacity 16 KA including all accessories complete all as specified and as directed Make:- Schneider, cat part No LV510317/Havells/L&T/Standard/ Legrand or equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 250 Amps with breaking capacity 36 KA as per IEC60947-2 including all accessories complete all as specified and as directed Make:- Schneider, cat part No LV52543/Havells/L&T/Standard/ Legrand or equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 400 Amps with breaking capacity 36 KA as per IEC60947-2 including all accessories complete all as specified and as directed. Make:- Schneider, cat part No LV516343/Havells/L&T/Standard/ Legrand or equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 630 Amps with breaking capacity 50 KA as per IEC60947-2 including all accessories complete all as specified and as directed. Make :-Schneider, cat part No LV516343/Havells/L&T/Standard/ Legrand or equivalent as approved by GE.
Disconnecting and taking down old unserviceable ATS of any description and capacity and Supply and fixing of Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1 foure pole ,AC -31A,50 Hz,415 Volts of capacity 100 amps automatic /manual with inbuilt time delay with enclosure complete all as specified and as directed. Make : Havells, cat part No. IHYFCDE100 /standard/equivalent make
Disconnecting and taking down old unserviceable ATS of any description and capacity and Supply and fixing of Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1 four pole ,AC -31A,50 Hz,415 Volts of capacity 200 amps automatic /manual with inbuilt time delay with enclosure complete all as specified and as directed. Make : Havells ,cat part No. IHYFCDE200 /standard/equivalent make
Disconnecting and taking down old unserviceable ATS of any description and capacity and Supply and fixing of Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1 four pole ,AC -31A,50 Hz,415 Volts of capacity 315 amps automatic /manual with inbuilt time delay with enclosure complete including fixing the ACB in the panel by cutting/drlling, nut, bolts and washers etc shall deemed to be included in the quoted rate complete all as specified and as directed Make :Havells ,cat part No. IHYFCDE315 /Standard/equivalent make
Disconnecting and taking down old unserviceable ACB of any description and capacity and supply and fix Air circuit breaker 4 Pole, 415V, with Fixed Type circuit breaker with microprocessor based with ET2B trip unit of capacity 800 amps with breaking capacity 50 KA as per Conforms to IEC/EN : 60947-2, IS-13947-2, ICS=100% of ICU, Icw=50 kA 1 sec, Ui = 1000V ,Uimp=12KV, Frequency = 50/60 Hz, cat B complete all as specified and as directed Make : Schneider-electric cat part No.SPS08F4PMF2B, Havells/ L&T/ Legrand etc or equivalent as approved by GE
Disconnecting and taking down old unserviceable Al Conductor of any description and capacity and Material and labour for fixing the Aluminium conductor, steel reinforced on the poles and tightening the conductor complete all as specified and directed by Engineer-in Charge
Disconnecting and taking down old unserviceable insulator of any description and capacity and Supply and fix shackle type, porcelain, vitreous, white, brown or green insulator of size 75 mm and dia 90 mm including one galvanised mild steel straps of size 31 x 3 mm, two galvanised iron washers and one galvanised iron bolts of dia 12 mm for 1100 volts grade complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down old unserviceable nature switch unit of any description and capacity and Supply and fixing of automatic street light switch NATURE SWITCH for automatic switching of streets lights based on lux level of natutral light .the sensor (nature switch ) along with suitable power contractor ,MCB and support terminals shoud be inclosed in pole /wall mountable enclosure made of rust proof ,electric shock proof ,termite proof and FR grade special moulding compund (sintex make SMC Junction Box ) conforming to IP-54.the contractor ,MCB and circuit wiring shoud suitable enough to take load of 5 KW single phase load 1.5 KW load equally distributed over 3-phase, contractor rating 20 Amps 4 pole and MCB (single -pole) rating 20 amps (SP-3 Nos) complete all as specified and directed by Engineer-in-Charge. Make and Model No. Healer and SWADEEP-02EC5/7KW 3 PHASE or equivalent make
Disconnecting and taking down old unserviceable bus bar chamber/Lt panel of any description and capacity and Supply and fixing of Wheather proof outdoor, Lt panel ,made out of 3.15 mm thick MS sheet comprising 4 Nos copper bus bar strips each of 400 amps ,45 cm long duly insulated on insulators including incomming MCCB 200 amps 36 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc 01 Nos and outgoing MCCB 100 amps 16 kA, Ics = 100% Icu, 02 Nos, TP 63 Amp 10 KA, C Curve = 01 Nos, complete with 4 nos mounting legs made out of 50 mmx50mmx6 mm angle iron grouted in PCC block of size 30cmx30cmx90cm (30cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6 ,type C-2 (using 40 mm grade crushed stone aggregate),and connection with size of aluminium thimbles,nuts,bolts and washers including Set of three LED lights RYB, complete internal wiring with suitable size of copper wire, digital voltmeter, ammeter, CT of ratio 50/5 of 3 nos and cable glands at entry and outlets points including excavation and earth work,returning filling and removal of surplus soils ,including taking out old unserviceable bus bar chamber complete all as specifiedand directed by Engineer -in -charge.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc, and provision of brass/copper nuts, bolts washers etc wherever required and making jointsas required 20x3 copper strip coplete all as specified and directed by Enginer-in-Charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable complete all as specified and as directed.
Supply and fix cable jointing kit for 1100 volts grade cable for straight through joint complete with Jointing material heat Shrinkable Lt straight through type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1100 KV grade cable for end joint complete with Jointing material heat Shrinkable type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrinkable Lt straight through type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Indoor/Outdoor type complete all as specified and directed.
Supply and fix off LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed.
Supply and fix powder coated corrugated black sheets of size 30 cm width as cable duct trays and similar work cut to size holes punched including round headed screws clout nails or rixet rivet and fixed to wall with plain 40 mm lap joints with revetted seams including bending or turning up metered angle etc as required of 3.15 mm thick sheet complete all as specified and as directed.
M & L for perforated angle of size 40x40x4mm powder coated for holding cable trays with complete nuts, bolts and washers to match the colour with cable tray complete all as specified and directed. The cost of drilling, cutting, fixing and any other requirement will be deemed to be included in quoted rate. Nothing extra shall be admissible on this account.complete all as specified and as directed
Supply only rubber boot 9 Nos suitable for 33 KV line with all accessories (full pvc dual density high ankle gum boots (12 " height )complete all as specified and as directed
Renewal of existing earthing (GI plate earthig) with provision of new layers of charcoal and salt all as specified in electrical plate No 3 of SSR Part-I, including cleaning of existing GI earth plate, strip/wire etc and connecting with new bolts, nuts and washers complete and testing on completion in all respect complete all as specified and as directed. Note: - Excavation, PCC for earth pit and cover, watering pipe, funnel with wire mesh, earth lead and protection pipe shall deemed to be included in the quoted rate.
Supply and fixing fire retardant electric insulation synthetic mat INSULATICA 2000" for 33 KV 3.0 mm thick +10% conforming to BIS DOC No ETD -02 (5231) P dt 2003. meeting requirement of IS 3043, IS: 5216 (Part 1,2,3) IS : 8437 and IEC 479 pub-1 IEC 61111 & 61112 tested for brake down strength tensile /elongation ageing properties. Insulation resistance, affects of acid , alkaline, Diesel & transformer oil, leakage current test fire test etc. having min width of 1000m + 20 mm complete as required suitable and using adhesive and allied chemical and scaling of all joints and border ends and fixing decorative taps the installed sheet complete as specified and directed.
Supply flood light 60 watt LED, 5700 K flood light engergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete as specified and directed
M&L for clamps made of 40 x 6 mm flat iron including nuts bolts, washers etc complete all as specified and as directed.
M&L for Bracket made out of 40 mm bore dia steel water tubing, light grade of over all length 1.20 metre including bending to shape and fixed to pole with and including mild steel clamps, bolts and nuts of appropriate size and shape as approved by Engineer-in-Charge complete all as specified and as directed
M&L for type B1 1:2:4 (20 mm graded aggregate) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed by Engineer-in-Charge.
M&L for type C2 1:3:6 (40 mm graded aggregate) cement concrete in foundation and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
Supply installed Single Phase 24 Volts battery charger Suitable for 36 Volts 120Ah SFM VRLA battery bank along with following :- Technical specification (i) 16 SWG CRCA sheet duly powder coated cabinet -01 No (ii) Copper wound transformer-01No (iii) Suitable bridge rectifier-01No (iv) Capacitor-01No (v) Filter Choke -01No (vi) Fixing / Current limiting control card -01No (vii) Current Limiting pot -01No (viii) DC Voltage out put set pot -01No (ix) DC Amp meter -01No (x) DC Volt meter -01No (xii) AC Main Volt meter -01No (xiii) Double pool MCB in Ac Mains -01No (Xiv) Double pool MCB in out put -01No (XV) Suitable input & Out put connector -01No Make: USHA,OMEGA, EXPOFYN,RADETRON,THYCON or equivalent,
Supply and fix of Battery Trolly angle iron heavy duty (20mmx20mmx3mm) of size 80 cm length and width 40 cm and height 50 cm complete all as specified and directed.
Cleaning the sub station in side and out side building/fencing/ two/four pole structure ,and also around 2 m radius out side the fencing every three month duly taking out unwanted material grass/vegitable/roots of tree/small tree etc complete as specified and directed
M&L for spraying the chemical (Roundup) in sub station in the ration 1: 3 for buring the grass every three month complete all as specified and as directed
Taking down old unserviceable of cable root marker and M&L for cable root marker as per site requirement complete all as per specified and directed.
Down conductor using 25 sqmm single core copper cable both ends thimbled properly with copper Lugs, including taking down old unserviceable ,complete all as specified and as directed by Engr-in-Charge. complete all as specified and directed.
Down conductor using 16 sqmm single core copper cable both ends thimbled properly with copper Lugs, including taking down old unserviceable ,complete all as specified and as directed by Engr-in-Charge. complete all as specified and directed.
M&L for Weather proof outdoor bus bar chamber wall mounted, made out of 1.6 mm thick MS sheet comprising of Copper strips each of 250 Amps, 8 way,appx 60cm long duly insulated mounted on insulators including complete with all accessories and connections with copper thimbles, nuts, bolts & washers including cable glands at entry and outlet points including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 16 sqmm complete all as per specified and directed.
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 35 sqmm complete all as per specified and directed.
Taking down old unserviceable lugs and M&L for Aluminium Lugs of size 185 sqmm complete all as per specified and as directed.
DAVINDER SINGH
ANIKET TRADERS
shivom builders
KARAN TRADERS
PAWAN KUMAR GOVT. CONTRACTORS
VAISHNO TRDAERS
MOHAN LAL AND SONS
LUXMI ELECTRONIC WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .