| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-Finance | ₹41.0 L | L1 | Accepted-Finance BOQ found in Order |
| 2 | L2₹42.6 LAccepted-Finance | ₹42.6 L | L2 | Accepted-Finance BOQ found in Order |
| 3 | L3₹42.6 LAccepted-Finance | ₹42.6 L | L3 | Accepted-Finance BOQ found in Order |
| 4 | L4₹44.8 LAccepted-Finance | ₹44.8 L | L4 | Accepted-Finance BOQ found in Order |
| 5 | L5₹45.7 LAccepted-Finance | ₹45.7 L | L5 | Accepted-Finance BOQ found in Order |
| Sl No | Description | Qty | Unit | M/s Kay Aar Enterprises L4 | ASIA ENTERPRISES L2 | M/S MEHTA BUILDERS L3 | GAGAN ENGINEERS AND CONTRACTORS L1 | M/S AKHILESHWAR ASSOCIATES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation of pole, laying of pipe line and getting out in any type of soil complete all as specified and directed. | 314.55 | Cum | 130 ₹40,891.5 | 50 ₹15,727.5 | 200 ₹62,910 | 40 ₹12,582 Lowest | 200 ₹62,910 |
| 2.00 | Returning filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed. | 278.1 | Cum | 45 ₹12,514.5 | 40 ₹11,124 | 75 ₹20,857.5 | 20 ₹5,562 Lowest | 50 ₹13,905 |
| 3.00 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 36.46 | Cum | 70 ₹2,552.2 | 40 ₹1,458.4 | 150 ₹5,469 | 20 ₹729.2 Lowest | 50 ₹1,823 |
| 4.00 | Design, fabrication, installation, testing and commissioning of 400 ampere auto starter cum fault analyzer cum protection & control panel at Stage-2 including following job:-
1) Fabrication of Power Handling Unit (PHU) / Auto Starter with power contactor MNX-400-2Nos., MNX-185-1No. of L&T make along with MCCB of 630 ampere rating also of L&T make.
2) The system should be provided with a solid state fault analyzer cum controller.
3) The complete system should be enclosed in a floor / wall mounted MS sheet enclosure / box of suitable gauge and dimensions with proper entry and exit holes for incoming and outgoing cables. The enclosure should be finished with powder coated painting from inside as well as from outer surface of approved colour. Job also includes mounting of the panel to the wall / floor of the pump room.
METERING:
4) The enclosure should be front shutter mounted with key locking system having glass window. Digital electronic voltmeter & ampere meter should be provided along with the required current transformer and selector switches. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end.
FEATURES AND SPECIFICATIONS:
5) The system should trip the motor on power failure and on appearance of an electrical fault mentioned below which may otherwise damage the motor field coils and should not restart automatically until unless the system is reset manually, thus providing automation to the system and protection to the motor. | 1 | Each | 2,50,000 ₹2,50,000 | 2,00,000 ₹2,00,000 | 1,90,000 ₹1,90,000 | 1,49,000 ₹1,49,000 Lowest | 3,00,000 ₹3,00,000 |
| 5.00Item No 4 Contd 6) The system shall provide protection against: - a. Low voltage below 350 V b. High Voltage above 450 V c. Single phasing d. Reverse phasing e. Un Balanced phasing f. Dry running g. Overloading INFORMATION SECTION: - In addition the system should have the following audio & visual features for a quick and accurate diagnosis of the appeared fault / status for a speedy rectification of the system. 7) Separate LED fault / status indicators. 8) LED phase indicators. 9) An isolation by pass system, for fault analysis system, with a blinking indicator. 10) 3 LED, contactor ‘COIL OK’, indicators, one for each of the contactors / coils. LED star & delta indicators to access the star to delta timing. 11) A tamper proof starting system to avoid manipulations by the motor operator to keep the system in a permanently ON position. Job further includes providing & fitting of accessories for connection from main panel. Complete job includes cost of panel/ material, labour charges, transportation/ shifting charges up to site of work, including installation, testing, commissioning and all taxes. | ||||||||
| 6.00 | Taking down the 220 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed.
Note :- (for item No 6 to 11) (i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item (ii) Cost of nuts, bolts, washers,connection plate,grease lubrication to bearing bushes ets are deemed to be included and supply only bearings and terminal plates will be measured and paid separately under respective items. | 3 | Each Job | 9,500 ₹28,500 Lowest | 80,000 ₹2,40,000 | 11,000 ₹33,000 | 95,000 ₹2,85,000 | 85,000 ₹2,55,000 |
| 7.00 | Taking down the 125 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | 6,800 ₹13,600 Lowest | 60,000 ₹1,20,000 | 80,000 ₹1,60,000 | 1,00,000 ₹2,00,000 | 70,000 ₹1,40,000 |
| 8.00 | Taking down the 100 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | 5,400 ₹10,800 Lowest | 65,000 ₹1,30,000 | 65,000 ₹1,30,000 | 90,000 ₹1,80,000 | 55,000 ₹1,10,000 |
| 9.00 | Taking down the 75 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | 5,000 ₹10,000 Lowest | 50,000 ₹1,00,000 | 60,000 ₹1,20,000 | 69,000 ₹1,38,000 | 50,000 ₹1,00,000 |
| 10.00 | Taking down the 60 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | 5,000 ₹10,000 Lowest | 40,000 ₹80,000 | 55,000 ₹1,10,000 | 69,000 ₹1,38,000 | 45,000 ₹90,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
22 Jun 2026, 6:00 pmClosed
GE (N) Akhnoor
GE (N) Akhnoor c/o 56 APO PIN 181201
REPAIR/MAINT OF EXTERNAL WATER SUPPLY NETWORK AT AKHNOOR MIL STN UNDER GE (N) AKHNOOR
2026_MES_767778_1
GE(N)/AKH-22/2026-27
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
Class D cat a ii
8 documents required · 8 mandatory
₹500
GE (N) Akhnoor
₹98,000
Yes
4 Jul 2026
25 May 2026
29 Jun 2026
25 May 2026
22 Jun 2026
8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation of pole, laying of pipe line and getting out in any type of soil complete all as specified and directed. | 314.55 | Cum | - | - |
| 2 | Returning filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed. | 278.1 | Cum | - | - |
| 3 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 36.46 | Cum | - | - |
| 4 | Design, fabrication, installation, testing and commissioning of 400 ampere auto starter cum fault analyzer cum protection & control panel at Stage-2 including following job:-
1) Fabrication of Power Handling Unit (PHU) / Auto Starter with power contactor MNX-400-2Nos., MNX-185-1No. of L&T make along with MCCB of 630 ampere rating also of L&T make.
2) The system should be provided with a solid state fault analyzer cum controller.
3) The complete system should be enclosed in a floor / wall mounted MS sheet enclosure / box of suitable gauge and dimensions with proper entry and exit holes for incoming and outgoing cables. The enclosure should be finished with powder coated painting from inside as well as from outer surface of approved colour. Job also includes mounting of the panel to the wall / floor of the pump room.
METERING:
4) The enclosure should be front shutter mounted with key locking system having glass window. Digital electronic voltmeter & ampere meter should be provided along with the required current transformer and selector switches. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end.
FEATURES AND SPECIFICATIONS:
5) The system should trip the motor on power failure and on appearance of an electrical fault mentioned below which may otherwise damage the motor field coils and should not restart automatically until unless the system is reset manually, thus providing automation to the system and protection to the motor. | 1 | Each | - | - |
| 5 | Item No 4 Contd 6) The system shall provide protection against: -
a. Low voltage below 350 V
b. High Voltage above 450 V
c. Single phasing
d. Reverse phasing
e. Un Balanced phasing
f. Dry running
g. Overloading
INFORMATION SECTION: -
In addition the system should have the following audio & visual features for a quick and accurate diagnosis of the appeared fault / status for a speedy rectification of the system.
7) Separate LED fault / status indicators.
8) LED phase indicators.
9) An isolation by pass system, for fault analysis system, with a blinking indicator.
10) 3 LED, contactor ‘COIL OK’, indicators, one for each of the contactors / coils. LED star & delta indicators to access the star to delta timing.
11) A tamper proof starting system to avoid manipulations by the motor operator to keep the system in a permanently ON position.
Job further includes providing & fitting of accessories for connection from main panel.
Complete job includes cost of panel/ material, labour charges, transportation/ shifting charges up to site of work, including installation, testing, commissioning and all taxes. | - | - | - | - |
| 6 | Taking down the 220 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed.
Note :- (for item No 6 to 11) (i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item (ii) Cost of nuts, bolts, washers,connection plate,grease lubrication to bearing bushes ets are deemed to be included and supply only bearings and terminal plates will be measured and paid separately under respective items. | 3 | Each Job | - | - |
| 7 | Taking down the 125 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | - | - |
| 8 | Taking down the 100 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | - | - |
| 9 | Taking down the 75 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | - | - |
| 10 | Taking down the 60 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting, and rewinding with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. | 2 | Each Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tender222627.pdf
Tender Documents • 1.04 MB
BOQ_859816.xls
BOQ • 4.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].