Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹46.3 L
Closing Date
9 Dec 2020, 3:00 pmClosed
DIRECTOR IISER PUNE
Director , IISER Pune
CONSTRUCTION OF CENTER FOR DATA SCIENCE, QUANTUM TECHNOLOGY AND ECS BY VERTICAL EXTENSION OF MAIN BUILDING ON 4TH AND 5TH FLOOR AT IISER PUNE
2020_IISRP_596562_1
01/IISER/PUNE/2020-21
Open Tender
Construction Works
730 days
IISER PASHAN PUNE
As per NIT
2 documents required · 2 mandatory
₹10,000
Director, IISER Pune
₹46.3 L
virtual
18 Dec 2020
13 Nov 2020
10 Dec 2020
13 Nov 2020
9 Dec 2020
13 Nov 2020
1 Dec 2020
Amount
CEMENT CONCRETE & REINFORCED CEMENT CONCRETE WORKS Providing and laying in position ready mixed concrete M‐ 30 using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, levelling and finishing the laid concrete top surface in line and level, curing, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer ‐ in ‐ charge. M‐30 grade Reinforced cement concrete by using minimum 345 kg of OPC cement ( 43 Grade) per cum of concrete as per IS standard plus fly ash 20 % or more confirming to Grade I of IS 3812 (Part‐I) with uniform blending with cement in accordance with clauses 5.2 and 5.2.1 of IS 456:2000 . Note : Contractor shall submit the necessary design mix reports from the approved Lab for the above grade of concrete with 28 days test results to the Engineer in charge for the approval of design mix prior to start of any type of concreting works at site. The contractor should quote his rate considering minimum 345 kg of 43 grade OPC cement plus required fly ash confirming to grade I of IS 3812 ( Part‐I) used as part replacement of OPC as per IS 456 with uniform blending with cement to be ensured in accordance with clause 5.2 and 5.2.1 of IS 456‐2000. Excess/less cement used as per design mix is payable/recoverable separately. Quote rate shall be inclusive of cost of all the materials, labour, machinery, all taxes, royalty and octroi etc.) All works above plinth level upto floor V level
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Stairs, (excluding landings) except spiral-staircases.
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Extra for shuttering in circular work ( 20% of respective centering and shuttering items) for Roof beams
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands,copings, bed plates, anchor blocks and the like.
Centering and shuttering including strutting, propping etc. and removal of form for removal of form for: Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) : Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Above plinth level. - Thermo-Mechanically Treated bars.
Providing and fixing in position 12mm thick bitumen impregnated fibre board conforming to IS:1838 including cost of primer, sealing compound in expansion joints.
Add for providing plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Brick work with FPS bricks of class designation 35 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) with PPC 43 grade cement having Fly ash content not less than 30%.
Brick work with modular fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 60 average compressive strength in super structure above plinth level up to floor V level in Cement mortar 1:6 (1 cement : 6 coarse sand) with PPC 43 grade cement having Fly ash content not less than 30%. -150/200/ 230 mm thick
Extra for brick work in superstructure above Floor V level for every four floors or part there of.
Half brick masonry with F.P.S. bricks of class designation 35/modular fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 60 average compressive strength in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand). with PPC cement having Fly ash content not less than 30%.
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position Second class teak wood. ( Frame size to be vary from 2" to 4".)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size)
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. Size 10 x 120mm
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood- 50x12 mm
Providing and applying Melamine polishing on wooden door frames of size upto 150mm x 80mm including polishing the edge lipping, surface preparation like thorough cleaning and removal of loose particles with Sand paper, Finish as per manufactures specification including labours, tools and tackles, scaffolding, Compressor etc. complete as per direction of Engineering- in-Charge (Two or more coat). ( Rate is inclusive of all the taxes, GST, Materials, Labours, wastage, carriage, loading, unloading and operation & nothing extra shall be payable)
General Steel Door ‐ Painted & Fire Doors Providing and fixing of Hollow metal door at all levels from ISO 9001‐2000 certified Manufacturer. The metal doors should be made from high grade galvanised steel stretched level sheet flush, with vision panel, louvers etc. Single /Double leaf to required sizes from approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. a)Door frame shall be single rebate profile of size 100 x 57 mm made out of 1.20mm thick galvanized steel sheet (18 gauge ). Frames should be MITERED and field assembled with self tabs. Door frames should be prepared for suitable hardware as scheduled and should have necessary reinforcement to withstand regular wear and tear. All provision should be mortised, drilled and tapped for receiving the hardware. Rubber door silencers should be provided on the striking jamb. All door frames should be provided with SOFIT bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once the frame is installed it should be grouted with cement & sand slurry. b)Door leaf should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 gauge) thick galvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. c)The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable with a clip on arrangement. The glass should be 12mm clear toughened glass All doors and frames shall be finished with etched primer coating (35 microns), stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint (35 micron DFT) of approved colour. Steel surface should be blast cleaned to near to clean surface. Once the surface is cleaned the doors should be checked for finish before it is taken for painting. d)Rate should include for supply and installation of door and hardware set as mentioned in the door and hardware schedule.
Steel door double leaf of size: 2.00 x 2.40m with the following hardwares , fittings vision panel of size 600x1100 mm ‐ 2 no Ball bearing butt hinges SS‐ 304 of 100 x 89 x 3mm as Per EN 1935 with CE mark ‐8 nos Door closure EN 5 ‐ 7 ( Dorma TS 93 / Geze ) with back check and delayed action in silver finish as per EN 1154 with CE mark ‐ 1 No ( mounting feature & speeed ) ‐speed control / overload protection / regular, parallel & over mounting features to be made available. Half dome door stopper in SS304 ‐ 2nos Handle SS304 make Shall be tested for corrosion resistence in accordance with AS 2331.3.1Neutral salt spray test ( Dorma SH 812,Lockwood HO 2 or equivalent ) Lock shall be of dead lock type with Euro profile cylinder and to be tested for 500000 operation cycles ,cylinder and turn with escintheions as per EN 12209 with CE mark.‐ 1no Flush bolt L=300mm at the bottom and 600mm at the top ‐ 2 nos ( Each one )
Steel door double leaf of size: 1800mm x 2400mm : with vision panel and following hardware set. Vision panel of size 300x300 mm ‐ 2 nos. Ball bearing butt hinges ( fire rated ) SS‐ 304 of 100 x 89 x 3mm as Per EN 1935 with CE mark ‐8 nos Door closure EN 5 ‐ 7 ( 2000V of GEZE / Dorma TS 93 or equivalent ) with back check and delayed action in silver finish as per EN 1154 with CE mark ‐ 1 No (mounting feature & speed) speed control / overload protection / regular, parallel & over mounting features to be made available. Half dome door stopper in SS304 ‐ 2nos Handle SS304 make Shall be tested for corrosion resistance in accordance with AS 2331.3.1 Neutral salt spray test (GEZE/ Dorma SH 812 or equivalent) Lock shall be of dead lock type with Euro profile cylinder and to be tested for 500000 operation cycles ,cylinder and turn with escintheions as per EN 12209 with CE mark.‐ 1no Flush bolt L=300mm at the bottom and 600mm at the top ‐ 2 nos ( each one ) Dust proof floor Socket ‐ 1no
Steel door double leaf (Un-equal)of size: 1500mm x 2400mm : with vision panel (300 x 300mm) with hardware set Vision panel of size 300x300 mm ‐ 1 no List of hard wares Ball bearing butt hinges ( fire rated ) SS‐ 304 of 100 x 89 x 3mm as Per EN 1935 with CE mark ‐8 nos Door closure EN 5 ‐ 7 ( 2000V of GEZE / Dorma TS 93 or equivalent ) with back check and delayed action in silver finish as per EN 1154 with CE mark ‐ 1 No (mounting feature & speed) speed control / overload protection / regular, parallel & over mounting features to be made available. Half dome door stopper in SS304 ‐ 2nos Handle SS304 make Shall be tested for corrosion resistance in accordance with AS 2331.3.1 Neutral salt spray test (GEZE/ Dorma SH 812 or equivalent) Lock shall be of dead lock type with Euro profile cylinder and to be tested for 500000 operation cycles ,cylinder and turn with escintheions as per EN 12209 with CE mark.‐ 1no Flush bolt L=300mm at the bottom and 600mm at the top ‐ 2 nos ( each one ) Dust proof floor Socket ‐ 1no
Steel door single leaf of size 1200 x 2400with following hardware and fittings‐ vision panel of size 300x300 mm ‐ 1 no List of hard wares Ball bearing butt hinges ( fire rated ) SS‐ 304 of 100 x 89 x 3mm as Per EN 1935 with CE mark ‐8 nos Door closure EN 5 ‐ 7 ( 2000V of GEZE / Dorma TS 93 or equivalent ) with back check and delayed action in silver finish as per EN 1154 with CE mark‐1 No (mounting feature & speed) speed control / overload protection / regular, parallel & over mounting features to be made available. Half dome door stopper in SS304 ‐ 1 no Handle SS304 make Shall be tested for corrosion resistance in accordance with AS 2331.3.1 Neutral salt spray test (GEZE / Dorma SH 812 or equivalent) Lock shall be of dead lock type with Euro profile cylinder and to be tested for 500000 operation cycles ,cylinder and turn with escintheions as per EN 12209 with CE mark.‐ 1no
Steel doors of size 600 x 1500 for shafts -with the following hardware and fittings Ball bearing butt hinges SS- 304 of 100 x 89 x 3mm as Per EN 1935 with CE mark -2 nos Shaft lock with Allenkey Flush full rectangular with screws in Stainless steel
Fire Door 2hr rated – Painted Providing and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1, for stability, integrity & insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Certifire or third party certified or equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent. Door frame shall be Double rebate grooved profile of size 143 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Door leaf shall be 46mm thick fully flush double skin door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material. Intumescent seals 15x2mm to be provided all around the door in addition to the grooved smoke seal. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.
Two hour rated door single leaf of size 1200 x 2400 with Panic bar‐ with the following hardwares and fittings i) vision panel of size 300x300 mm ‐ 1 no List of hardwares Ball bearing butt hinges ( fire rated ) SS‐ 304 of 100 x 89 x 3mm as per EN 1935 with CE mark ‐ 8 nos Door closure EN 5‐ 7 ( 2000V of GEZE / Dorma TS 93 or equivalent) with back check and delayed action in silver finish as per EN 1154 with CE mark ‐ 1 No (mounting feature & speed) speed control / overload protection / regular, parallel & over mounting features to be made available. Half dome door stopper in SS ‐ 1no Exit device / panic bar shall be single point locking system ,external trim & cylinder, key entry with key/ lever mechanism safety over ride features to be adopted, and shall comply with EN 1125 with CE mark ‐1No Dorma 3000 series or equivalent
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.: Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume hardening compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, fixing of glass strips of 5 mm thick for floor separation for the panel area of 20 sqm .
Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. - 18 mm thick
Providing and fixing Ist quality Italian shade/Digital Series Vitrified wall tiles 300mm x 600mm conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying double charge / Premium quality Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) in required pattern including grouting the joints with white cement and matching pigments etc., complete. Rate shall include for preparation of base surface & finished the surface, protection with gypsum / POP layer over plastic sheet and removing the same before handing over, work at all levels, as directed.by engineer in charge Size of Tile 600x600 mm
Providing and laying double charge / Premium quality Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) in required pattern including grouting the joints with white cement and matching pigments etc., complete. Rate shall include for preparation of base surface & finished the surface, protection with gypsum / POP layer over plastic sheet and removing the same before handing over, work at all levels, as directed.by engineer in charge Size 1000 x 1000 mm
Providing and laying double charge / Premium quality Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) in required pattern including grouting the joints with white cement and matching pigments etc., complete. Rate shall include for preparation of base surface & finished the surface, protection with gypsum / POP layer over plastic sheet and removing the same before handing over, work at all levels, as directed.by engineer in charge. Matt finish of size 1200 X 600MM - Light shade
Providing and laying double charge / Premium quality Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) in required pattern including grouting the joints with white cement and matching pigments etc., complete. Rate shall include for preparation of base surface & finished the surface, protection with gypsum / POP layer over plastic sheet and removing the same before handing over, work at all levels, as directed.by engineer in charge. Matt finish of size 1200 X 600MM - Dark shade
Providing and laying double charge / Premium quality Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.: Size of Tile 600x600 mm
Providing and laying double charge / Premium quality Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. : Size 1000 x 1000 mm
Providing and laying double charge / Premium quality Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. : Matt finish of size 1200 X 600MM - Light shade
Providing and laying double charge / Premium quality Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. : Matt finish of size 1200 X 600MM - Dark shade
CARPET FLOOR Providing and laying of approved make 100% Optimum SD Nylon Tufted, Textured Loop Pile carpet tiles of density more than 6500 oz and 20oz/sq.mtr of size 600mmx600mm or any standard size, permanent static control, solution dyed, pile height about 0.118inches with PVC free backing, colorfastness > or =4 after 100hours, moth proof, stain resistant etc. complete, over existing flooring with approved adhesive as per Manufacturer's specification and direction of the Engineer in charge. The carpet should be ,class-1 fire rated ,antistatic, moisture barrier, etc. Plank/square. The rate shall be include the cost of the supply, installation,taxes all leads and lifts and nothing shall be paid extra on this account. Finished area of installed carpet will be measured for payment.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/POP layer over plastic sheet and removing the same before handing over, work at all levels, as directed. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/POP layer over plastic sheet and removing the same before handing over,work at all levels, as directed. (Polished Granite stone slab steel grey, multi red, jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.)
Providing and laying granite stone in step / skirting in single size or in combination of different sizes as per approved drawings with 18 mm thick mirror plolished granite of approved colour, shade and texture with cement slurry spread at the rate of 4.4 kg of cement per sqm over an average thickness of 20mm cement mortar 1:4 (1cement : 4 coarse sand) including finishing the joint with white cement and matching pigments with approved shade all complete as per direction of Engineer in charge. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/POP layer over plastic sheet and removing the same before handing over,work at all levels, as directed. : With not less than18mm thick Granite stone slab area 0.50 sqm and above of single slab (Paradiso,SilverPearl, Sable brown, Ivory fantasy,Tan brown, juprano, steel grey, lavender blue pearl white or equivalent shades)
Providing wall cladding with best quality approved colour granite slab of any shade not less than 18 mm thick machine cut and machine high pre‐polished, set in C.M 1:4, 15 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern/design including finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin‐oxide polish as per manufacturer's Specification and as directed. Rate shall include for preparation of base surface , finished the surface, & protection with gypsum/POP layer over plastic sheet and removing the same before handing over,work at all levels, as directed. work at all levels and as directed.
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, full round moulding and polishing to edges to give high gloss finish etc. complete at all levels. : Granite of any colour and shade - Area of slab above 0.50 sqm
Extra for antique finish / Flame proof granite stone flooring in step, treads, skirting etc.
Extra for providing edge moulding to 18mm thick Granite stone counters, Vanities, nosing of treads etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Providing and fixing 30 mm thick kadappa stone support for granite platform for wash basin counters etc. .making slits for accommodating wash basin & fitting it complete with 20 mm cement mortar 1: 4 at supports this complete as per direction of Engineer‐incharge.
Extra for providing opening of required size & shape for waste coupling of wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.: Granite Stone of approved shade
False Flooring : Providing and fixing Access floor systems of Unitile® or approved equivalent make all as per the specifications mentioned vide Annexure I "Detailed specification of perticular BOQ item" of Special condition of contract (Page no 399-400) and confirming to PSA MOB - PF2 PS/SPU or NFPA 262 standards and direction of Engineer in charge. System : The system shall provide for suitable pedestal of height 450mm and under-structure designed to withstand various static loads and rolling loads subjected to it in an office / server / DCS / panel / rack area. The entire Access floor system shall provide for adequate fire resistance, acoustic barrier and air leakage resistance.The panel shall be laminated with 1.5 mm thick FR grade antistatic laminate/pvc to ensure maximum bonding to the steel surface. The edges of the laminated/PVC are protected with black PVC edge trim 5mm wide on all sides. This edge trim is mechanically locked and sealed in place to avoid detachment. Pedestals : Pedestal installed to support the panel shall be suitable to achieve a finished floor height of 75 to 600mm. Pedestals shall support an axial load of 2000 Kgs, without permanent deflection and an ultimate load of 3500 Kgs. Pedestal head shall be designed to avoid any rattle or squeaks. Understructure : Understructure system consists of stringers of size 570 x 32x 20 x 1.5mm to form a grid of 600 x 600mm. These stringers are locked into the pedestal head and run both ways. The US system shall provide adequate solid, rigid and quiet support for access floor panels. The US system shall provide a minimum clear, uninterrupted height of 550 mm between the bottom of the floor and bottom of the access floor for electrical conduiting and wiring. Panel Loading: The panel must comply with the, Concentrated Point Load : 360 kgs on a 25 x 25 mm square on the centre of the panel with a maximum permissible deflecting of not more than 2.5mm & Uniformly Distributed Load (UDL): 1080 kg/M2 with a maximum permissible deflection of not more than 2.0mm. Fire Rating : The Panels shall confirm to Class O & Class 1 Fire Ratings tested as per BS 476 Part 6 & 7. Rate shall include to produce a test certificate for the above load from manufacturer or from the approved laboratory, preparation of surface, cutting for supply/return Air Grills and for Grommet of required size, wastages, lead & lift, grouting the system with anchor fastener, removing all debris from the premises etc. complete, as directed and for providing class O Armaflex Nitrile rubber of 15mm thick as a sub floor insulation with SSR 98 adhesives to the entire area of existing (Below false flooring) as per manufacturer's specification. Rate shall inclusive of providing ramp in false flooring in the entry as shown in drawing. Rate shall inclusive of all materials labours as directed above. Mode of measurement : - Plan area only shall be measured and paid.
Antistatic Vinyl flooring - 2mm thick : Providing and laying of Antistatic Vinyl Sheet Flooring manufactured by Armstrong - Pastel SDAntistatic Vinyl flooring (Thickness 2.0mm) (Sheet- Length 16-25mtrs x width 1.8mtrs) / Tarket Antistatic vinyl flooring Ecplice SD / TORO SD ( (Sheet- Length 23mtrs x width 02mtrs) / Antistatic vinyl flooring GERFLOR-MIPOLAM Elegance EL5 ( (Sheet- Length 23mtrs x width 02mtrs) / With accessories- Cove Fillet and Weld cord. All joints between vinyl sheets shall be sealed & welded using approved colour welding rod to match the flooring colour after 24 hours of laying of rolls. Welding and seaming shall be done using automatic hot seam welding machine. Rate to include protection with 500 micron LDPE sheet with taped edges until completion of all other activities as the floor as per the instructions of Engineer in charge. Vinyl sheets should be laid over the existing vitrified flooring 2 to 3 mm thick. Flooring shall be laid 200mm on adjoin wall and copper strips of 0.5mm thick & 20mm wide shall provided to form the grid of 1000mm X 1000mm & to be properly connected with nearest earthing terminal . Vinyl sheets shall be manufactured as per CE norms and EN 649/EN ISO10851. Antistatic parameters shall be as per EN 61340 / EN 1815 / EN 1081. Actual area of flooring laid at site shall be measured for payments. Rate shall be including all taxes, duties, wastage, capping accessories, material testing samples and testing expenses etc complete. Nothing extra paid separately. Approved make Armstrong / Tarket / GERFLOR
12mm cement plaster of mix 1:4 (1 cement : 4 fine sand) with PPC cement having Fly ash content not less than 30%.
15 mm cement plaster on the rough side of single or half brick wall of mix cement plaster 1:4 (1 cement: 3 fine sand) with PPC cement having Fly ash content not less than 30%.
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge, with PPC cement having Fly ash content not less than 30%.
6 mm cement plaster of mix : 1 : 3 ( 1 cement : 3 fine sand ) with PPC cement having Fly ash content not less than 30%. ( Ceiling plaster )
Extra for providing and mixing water proofing material of approved make in cement plaster work in proportion recommended by the manufacturers.min 2% by weight of cement to be considered .
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof (19m to 22m)
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof (22 m to 25 m)
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof (25 m to 28 m)
Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3m or part thereof (28 m to 31 m)
Extra for plastering on circular work not exceeding 6 m in radius:
Providing and applying 2 coats of Wall Care Putty Birla / Altek or equivalent ( total thickness not less than 2mm) having water absorption less than 0.5%, making it smooth over plastered surface of walls and ceilings (should be in line & level) including cleaning & removing loose particles over the surface & proper pre wetting the surface before applying putty.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (AHU & Electrical Internal walls & ceiling for Lab). : New work (two or more coats) over and including priming coat with cement primer
Painting with synthetic enamel paint of satin finish of approved brand and manufacture to give an even shade including two coats of oil based enamel primer : Two or more coats on new work
Providing two coats of Acrlic emulsion paint to Internal walls and ceiling of approved colour over two coats of water based primer including preparation of surface by thorough cleaning and wetting and applying Wall Care Putty Birla / Altek or equivalent as per manufacturer’s specification fully to give an even shade before and subsequent application and making good all small holes of nails, open joints and minor defects of every kind after application of priming coat painting and curing as per manufacturers specifications of approved makes and as directed. (Wal care putty will be paid seperately)
Providing two coats of first quality Weatherproof paint of Apex approved brand and colour to plastered walls over a coat of approved cement based primer including preparation of surface through cleaning and wetting as per manufacturer’s specification fully to give an even shade before and subsequent application and making good all small holes of nails, open joints and minor defects of every kind after application of priming coat all as per Specification and as directed.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface
Toilet water proofing : Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
Terrace Water proofing : Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material out side of the premises as per direction of Engineer - in- charge.
Demolishing all kinds of masonry work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. : In cement mortar
Demolishing the existing integral cement based water proofing treatment with brick bat and cement mortar of average thickness 120mm at terrace of 3rd floor of the building including disposal of the rubbish outside the campus as per direction of Engineer - in - charge and local bodies. Rate includes all the above activities, charges of local bodies fo disposal of debries and nothing shall be paid extra on this account.
Making hole for rebar in concrete / masonry surface to any dia and depth as required @ site by using HILTI make driller with HY150 chemical compound for inserting the reinforcement after drilling and air jet. Cleaning etc complete, at any level, etc complete. Rate shall include for all charges and preparation of surface, cutting of reinforcement cleaning the surface, staging, scaffolding and working platform, application of necessary chemical / foil as per manufactures specification with necessary tools and equipments, water and power, removal of debris from the site, tax component etc complete, as directed. a) 8 / 10 / 12 MM Dia - Rebar for the depth vary from 100 mm to 120 mm
Making hole for rebar in concrete / masonry surface to any dia and depth as required @ site by using HILTI make driller with HY150 chemical compound for inserting the reinforcement after drilling and air jet. Cleaning etc complete, at any level, etc complete. Rate shall include for all charges and preparation of surface, cutting of reinforcement cleaning the surface, staging, scaffolding and working platform, application of necessary chemical / foil as per manufactures specification with necessary tools and equipments, water and power, removal of debris from the site, tax component etc complete, as directed. b) 6/ 20/ 25 MM Dia Rebar for the depth vary from 150 to 200 mm
Providing drilling and driving of various Dia & Shape Anchor rods / Anchor fastener of HILTI make or approved equivalent including all other consumables like chemicals, foils, Grouting materials using HILTI make machinery, tools & plants, all accessories etc complete and as directed. : HST M 8/10 - 75 mm long.
Providing drilling and driving of various Dia & Shape Anchor rods / Anchor fastener of HILTI make or approved equivalent including all other consumables like chemicals, foils, Grouting materials using HILTI make machinery, tools & plants, all accessories etc complete and as directed. : HST M 10/30 - 110 mm long.
Providing drilling and driving of various Dia & Shape Anchor rods / Anchor fastener of HILTI make or approved equivalent including all other consumables like chemicals, foils, Grouting materials using HILTI make machinery, tools & plants, all accessories etc complete and as directed. : HST M 16/25 - 140 mm long.
Providing drilling and driving of various Dia & Shape Anchor rods / Anchor fastener of HILTI make or approved equivalent including all other consumables like chemicals, foils, Grouting materials using HILTI make machinery, tools & plants, all accessories etc complete and as directed. : HVU M 12x110 with HAS-E M 12/110/28 - 160mm long.
Providing drilling and driving of various Dia & Shape Anchor rods / Anchor fastener of HILTI make or approved equivalent including all other consumables like chemicals, foils, Grouting materials using HILTI make machinery, tools & plants, all accessories etc complete and as directed. : HVU M 16x125 with HAS-E M 16/125/38 - 190mm long.
Providing drilling and driving of various Dia & Shape Anchor rods / Anchor fastener of HILTI make or approved equivalent including all other consumables like chemicals, foils, Grouting materials using HILTI make machinery, tools & plants, all accessories etc complete and as directed. : HVU M 20x170 with HAS-E M 20/170/48 - 240mm long.
Providing drilling and driving of various Dia & Shape Anchor rods / Anchor fastener of HILTI make or approved equivalent including all other consumables like chemicals, foils, Grouting materials using HILTI make machinery, tools & plants, all accessories etc complete and as directed. : HVU M 24x210 with HAS-E M 24/210/54 - 290mm long.
Making Core Cutting in slabs / beams / retaining walls and any other R.C members to any dia & depth by using 'HILTI' make diamond drilling machine with tolerance for any type of inserts, anchor fasteners etc. Rate shall include for all charge, preparation of surface, cutting of reinforcement, cleaning the surface, staging, scaffolding application of necessary chemical / foil (HAV) as per manufactures specification with necessary tools and equipments water and power, removal of debris from the site, staging scaffolding etc complete, as directed. : 75 to 110 mm dia pipe to the following depth: 150 mm to 200 Depth
Making Core Cutting in slabs / beams / retaining walls and any other R.C members to any dia & depth by using 'HILTI' make diamond drilling machine with tolerance for any type of inserts, anchor fasteners etc. Rate shall include for all charge, preparation of surface, cutting of reinforcement, cleaning the surface, staging, scaffolding application of necessary chemical / foil (HAV) as per manufactures specification with necessary tools and equipments water and power, removal of debris from the site, staging scaffolding etc complete, as directed. : 110 to 160 mm dia pipe to the following depth:150 mm to 200mm Depth
Providing and sealing the expansion joints with proprietary based joint sealing systems from CS (Construction Specialities) or equivalent approved manufacturer , Necessary Vapour barrier or backer rod, Aluminium extrusions, sealants if required, anchor bolts, tapes, capping, gaskets etc., complete as per approved details/drawings. Cost to include drilling and fixing of extrusions using heavy duty anchor bolts and sealing the joints capable of withstanding repeated extensions, compressions, vibrations and cyclic movement without lot of adhesion and resist deterioration by weathering, sunlight, ozone, water, salt water, oil, fuels and most of the commonly used acids etc., complete with 50% movement capability(vendor has to submit the Guarantee certificate for the product) Cost to include cleaning the edges of the joints, removal of Tri-board filler material to the required depth and preparation of edges with polymer modified mortar, sealing the gap at slab with Vapour barrier of thickness not less than 1.2mm for water tightness and covering the gap with react series expansion joint covers as approved by the Architect and as per the manufacturer’s specification. Floor to Floor & Roof to Roof (horizontal installation) - CS make Model No ALSW-300 or equivalent.
Providing and sealing the expansion joints with proprietary based joint sealing systems from CS (Construction Specialities) or equivalent approved manufacturer , Necessary Vapour barrier or backer rod, Aluminium extrusions, sealants if required, anchor bolts, tapes, capping, gaskets etc., complete as per approved details/drawings. Cost to include drilling and fixing of extrusions using heavy duty anchor bolts and sealing the joints capable of withstanding repeated extensions, compressions, vibrations and cyclic movement without lot of adhesion and resist deterioration by weathering, sunlight, ozone, water, salt water, oil, fuels and most of the commonly used acids etc., complete with 50% movement capability(vendor has to submit the Guarantee certificate for the product) Cost to include cleaning the edges of the joints, removal of Tri-board filler material to the required depth and preparation of edges with polymer modified mortar, sealing the gap at slab with Vapour barrier of thickness not less than 1.2mm for water tightness and covering the gap with react series expansion joint covers as approved by the Architect and as per the manufacturer’s specification. Column to Column or Column to Wall or wall to wall (vertical installation) CS make SM-4N(M1)/SMC-4N(M1) or equivalent.
Supplying, fixing and testing of PVC SWR - A class pipe confirming to IS 13592-1992 and 6 kg pvc pipe confirming to IS4985 for rain water from terrace level, with necessary specials like bends,shoes etc., complete.Rubber ring joints and solvent cement joints are used for jointing pvc pipes with fittings.Wall brackets rates not included. : 160mm diametre
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. - 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. : Coupler - 110 mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. : Bend with access door 87.5° - 110 mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. : Shoe (Plain) - 110 mm dia
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding at atrium roofing at terrace of the building at height of 25m from ground level etc complete as per the direction of Engineer in charge. Standard section weight shall be refered for the measurement and payment purpose.
Supply of aluminium sections required for atrium roofing of proposed building at height of 25m from ground level as directed by engineer in charge. Standard section weight shall be refered for the measurement and payment purpose. The installation is covered in the item No... as above.
Supply of structural glazing system with 10 mm thick plain clear UV coated polycarbonate sheet of approved make panels, cut to required size with required fittings and fixture, gutters, gaskets, aluminium beading , sealants as per approved design and drawings. Conducting the test for the materials involved in the system, field test on the erected system at site as per the test criteria set out in the specification of External glass ceiling/roofing / Facade structural glazing system.
Supplying structural glazing system with laminated glass panels of 13.52 mm nominal thickness PVB heat strengthen glass roofing/ceiling system, consisting of 2 Nos 6 mm thick glass of approved make with interlayer of 1.52 mm thick PVB - santry plus of Dubond make. Outer pane glass shall be reflective coated glass - Sunergy clear of Asahi make or ST 167 of Saint gobain make. Inner pane shall clear glass and both panes shall heat treated and heat soak tested. required fittings and fixture, gutters, gaskets, spiders of approved make, sealants, 3M shatter film of suitable thickness, including P/F ceramic frit as per required pattern and design approved by the Engineer in charge fixed over M S main frames/ aluminium frame work in sky light glass ceiling/roofing as per approved design and drawings by maintaining a groove width not be more than 10 mm both in horizontal and vertical. Conducting the test for the materials involved in the system, field test on the erected system at site as per the test criteria set out in the specification of External glass ceiling/roofing / Facade structural glazing system.
Providing and fixing Storm proof louver "Z" type made out of specially extruded aluminium with anodized finish and as specified in Particular specifications and to be fixed with pitch not less than 50 mm and overlapping shall be 25mm as minimum complete as per approved drawings. Length and breadth of louvers panel out to out excluding supporting frame shall be measured for working out area for payment.
Providing and fixing 4 mm (0.5 + 3.0 + 0.5) ACP with 3000 series coil and 100% virgin LDPE core) dry cladding with Aluminium composite panel of approved make, on external surface like column, wall, jambs, sills, projected area, ceiling or any surface to any profile and shape, horizontally, vertically, sloped, curved, circular etc aluminium cleats etc complete including design and drawing of supporting frame work to withstand the Wind load- wind speed shall be taken as per IS 875 Part - III for building at Pune complete including aluminium supporting base frame work of aluminium angle, box sections etc which shall be paid separately. Length and breadth of finished lover work shall be measured for working out the area for payment. Rate shall be inclusive of cost of all materials, design & drawings at all height and all floor level.
Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work)
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
Providing and placing on terrace (at all floor levels) three layered polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with threaded nipple and the base support for tank.
Providing and fixing stainless steel auto close hinges with soft closing Ebco/Haffele/Godrej/Hettich or equivalent as appoved by engineer-in-charge etc complete as per the direction of Engineer in charge.
Providing and fixing stainless steel telescopic drawer chanels of Ebco/Haffele/Godrej size 450 mm etc complete as per the direction of Engineer in charge.
Providing and fixing Drawer lock of of Ebco/Haffele/Godrej/Hettich or equivalent as appoved by engineer-in-charge to drawer of pedestal/storage with steel screws etc. complete as per direction of Engineer-in-charge.
Providing & fixing of SS matt finished handles to drawer unit and pesdestal unit of Ebco/Haffele/Godrej/Hettich or equivalent as appoved by engineer-in-charge.-Handles- 100mm
Providing & fixing of SS matt finished tower bolts to storage unit of Ebco/Haffele/ Godrej/Hettich or equivalent as appoved by engineer-in-charge.-Tower bolts- 75mm
MODULAR CUSTOM MADE OFFICE AND CLASSROOM FURNITURE Design, manufacturing, assembling, transporting and placing in position knock down modular custom made furniture such as table, pedestal units, wall hung storage, classrooms desks, student hostel furniture, etc. as per architectural drawings/layouts, technical specifications and directions of Engineer-in- charge. In general all outer exposed edges of all panels shall be covered sealed with 2m thick PVC edge banding tape, Rehau Dollkin or equivalent make and post formed edge in front exposed side and all concealed and butt of all panels shall be covered and sealed with 0.7mm edge banding tape of same make with hot melt glue banding machine at required temperature for table tops. All joinery fabrication work shall be done with minifix fittings (Hettich, Aries, Efficient cadget Ltd. or equivalent), plastic/Stainless steel dowels, Stainless steel screws washers in approved factory supplying minifix fittings, closing loaded hinges multipurpose lock, Stainless steel handles of approved design etc complete as per the direction of engineer in charge and shall be paid under sub heads described below. TABLE TOPS FOR OFFICE AND CUSTOM MADE CONFERENCE TABLES (A) Providing, fixing table tops with 25mm thick plain MDF board of approved make with 0.6 to 0.8 mm thick flex post form laminate ( Marino or equivalent) with post formed edge in two exposed sides and other two sides shall be sealed with 2mm thick PVC edge banding (Rehau or equivalent) of required shade and balancing laminate of required thickness at bottom surface complete as per specification and direction of the Engineer in charge. Actual area of the finished top shall be measured for payment.
MODULAR CUSTOM MADE OFFICE AND CLASSROOM FURNITURE Design, manufacturing, assembling, transporting and placing in position knock down modular custom made furniture such as table, pedestal units, wall hung storage, classrooms desks, student hostel furniture, etc. as per architectural drawings/layouts, technical specifications and directions of Engineer-in- charge. In general all outer exposed edges of all panels shall be covered sealed with 2m thick PVC edge banding tape, Rehau Dollkin or equivalent make and post formed edge in front exposed side and all concealed and butt of all panels shall be covered and sealed with 0.7mm edge banding tape of same make with hot melt glue banding machine at required temperature for table tops. All joinery fabrication work shall be done with minifix fittings (Hettich, Aries, Efficient cadget Ltd. or equivalent), plastic/Stainless steel dowels, Stainless steel screws washers in approved factory supplying minifix fittings, closing loaded hinges multipurpose lock, Stainless steel handles of approved design etc. All under bench supporting structure shall be consisting of M S tubes round/square as per co standard design with zinc phosphated/degreased and epoxy powder coated 50 to 60 microns DFT, nuts and bolts, rivets, pins complete as per approved drawings and direction of the Engineer in charge and shall be paid under sub items described in bill of quantities below. TABLE TOPS FOR OFFICE AND CUSTOM MADE CONFERENCE TABLES (B) Providing and fixing prelaminated or machine pressed laminated 18mm thick MDF board of required shade with all exposed side edges shall be sealed with 2mm thick PVC edge banding (Rehau or equivalent) in modesty panels, side panels etc. The MDF board shall be laminated with 1mm thick face laminate of approved brans and balance laminate shall be 0.8mm thick white laminate complete as per specification and direction of the Engineer in charge.
MODULAR CUSTOM MADE OFFICE AND CLASSROOM FURNITURE Design, manufacturing, assembling, transporting and placing in position knock down modular custom made furniture such as table, pedestal units, wall hung storage, classrooms desks, student hostel furniture, etc. as per architectural drawings/layouts, technical specifications and directions of Engineer-in- charge. In general all outer exposed edges of all panels shall be covered sealed with 2m thick PVC edge banding tape, Rehau Dollkin or equivalent make and post formed edge in front exposed side and all concealed and butt of all panels shall be covered and sealed with 0.7mm edge banding tape of same make with hot melt glue banding machine at required temperature for table tops. All joinery fabrication work shall be done with minifix fittings (Hettich, Aries, Efficient cadget Ltd. or equivalent), plastic/Stainless steel dowels, Stainless steel screws washers in approved factory supplying minifix fittings, closing loaded hinges multipurpose lock, Stainless steel handles of approved design etc. All under bench supporting structure shall be consisting of M S tubes round/square as per co standard design with zinc phosphated/degreased and epoxy powder coated 50 to 60 microns DFT, nuts and bolts, rivets, pins complete as per approved drawings and direction of the Engineer in charge and shall be paid under sub items described in bill of quantities below. TABLE TOPS FOR OFFICE AND CUSTOM MADE CONFERENCE TABLES (C) Providing and fixing 3 drawer Pedestal unit size: 390mm (W) x 440mm(D) x 646mm (H) /390mmx435mmx656mm mdae up from 18mm and 12mm prelaminated MDF board including recessed handles, sliders and centralized locking system decorative leg shoe / revolving type 360 degree castors. All exposed side edges shall be sealed with 2mm thick PVC edge banding (Rehau or equivalent) machine pressed etc complete as per the direction of Engineer in charge.
LEG SHOE & LEVELLERS Providing, fixing and supply of leg shoe made nylon 6 to mount levelers as per standard design on the legs of furniture with + 50 mm height adjustment. Levelers are made of Nylon 6 with M8 bolts insert molded to take care of floor undulation.
CABLE MANAGER Providing, fixing and supply of wire cable manager in work of 62 mm dia with PVC cover of approved make complete as per specification and direction of the Engineer in charge.
Providing and fixing 30 -50 mm aluminium profile stairs nosing of "Dural India" or equivalent make as approved by the Engineer in charge.
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
Providing and fixing, in position 8mm/12mm thick Tapered edge calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with compressive strength 225 kg/ sq.cm, Bending strength 100 kg/sq.cm. for wall paneling / Partitions over the MS / aluminium framework using Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves and fully threaded self-tapping dry wall screws, all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. Rate excludes the cost of framework but includes the cost of calcium silicate board and fixing of the board, all taxes leads lifts and nothing shall be paid extra on this account. Finished area of the board will be measured for payment. : 12mm thick calcium silicate board.
Providing and fixing, in position 8mm/12mm thick Tapered edge calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with compressive strength 225 kg/ sq.cm, Bending strength 100 kg/sq.cm. for wall paneling / Partitions over the MS / aluminium framework using Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves and fully threaded self-tapping dry wall screws, all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. Rate excludes the cost of framework but includes the cost of calcium silicate board and fixing of the board, all taxes leads lifts and nothing shall be paid extra on this account. Finished area of the board will be measured for payment. : 8mm thick calcium silicate board.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion - Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing 12 mm thick MR grade plywood of approved make in Partition, false flooring, walls and steps etc with necessary screws & favicol adhesive complete as per direction of Engineer in charge. Finished area shall be measured for payment in sqm.
Providing and fixing factory made 3mm decorative veneer approved colour shade design pattern sheet Marino or equivalent approved make for doors, windows and clerestory windows, with adhesive smooth finishing etc. all complete as per per direction of Engineer-in-charge.( Rate is inclusive of all the taxes, GST, Materials, Labours, wastage, carriage, loading, unloading and operation & nothing extra shall be payable)
Providing and applying Melamine polishing on wood work / wooden surface including surface preparation like thorough cleaning and removal of loose particles with Sand paper, Finish as per manufactures specification including labours, tools and tackles, scaffolding, Compressor etc. complete as per direction of Engineering- in-Charge (Two or more coat). ( Rate is inclusive of all the taxes, GST, Materials, Labours, wastage, carriage, loading, unloading and operation & nothing extra shall be payable)
Straight Glazed Partition-Slim line of approved make: Providing and installation of full height straight glass partition up uo 2.40m from FFL and fixing 12mm thick toughened and heat soaked glass and proprietary type anodized aluminium slimline sections of approved make. The sections shall be matt finish natural anodized and shall be a combination of male and female frames on all four sides as per the manufacturers specification. The rate shall be including the cost of all necessary hardwares, anodized aluminium jointing profile on edges of the glass in parallel glass joints, and anodized aluminium corner profile in corner glass joints including the cost of 12mm thick toughened and heat soaked glass.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Sal wood
Providing and fixing of 100mm high modular aluminum profile skirting of PARELLEL or equivalent make, made up of aluminum with uniform thickness of 1.4mm through the length the , minimum length of the aluminum profile skirting shall be 3m with anodized approved color , minimum thickness of anodizing shall be 15microns. Fixing of skirting shall be done with star headed anti-rusting coated screws on the ready available wall surface including all accessories. Fixing of skirting shall be done as per manufacturer's specifications. Item shall be including capping strip made up of PVC to cover rivets, screws etc, corner guards made up of hard PVC material shall be fixed at all the corner. All exposed ends of skirting shall be capped with PVC covering at all locations. Rate shall be including all taxes, duties, wastage, capping accessories, material testing samples and testing expenses etc complete. Actual length of skirting fixed at site shall be measured for the payments. Nothing extra paid separately. Approved make PARELLE or Equivalent.
FALSE CEILING : Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 10 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
Providing and fixing AMF Thermatex Antaris complete Mineral Fibre Ceiling tile of approved make or equivalent suspension system to consist of 2mm or 3mm GI suspension rod/wire with adjustable Butterfly Clips of 4mm dia securely affixed to structural ceiling using 10mm dia hook type anchor fastener . Ceiling Suspension System to be fixed at interval ( Main Runner ) of 1200mm spacings. Proprietary supplied ceiling suspension system to consist of Main Runners @ 1200mm and joined by C Channel @ 300mm to form overall grid opening of 1200mm * 300mm center to center. Additional cross tees are to be placed where appropriate for light fixtures, AC diffusers etc. exposed surfaces chemically cleaned and capped prefinished in high-gloss polyester enamel with two coat system on cold rolled steel. False ceiling will be measured only for the laid area, inclusive of all vertical drops, edge moldings, facias, etc. Rate quoted to include all cut - outs required for light fixtures, smoke detectors and other services cut - outs complete as directed by Engineer in charge. Product : AMF Thermatex Antaris Complete VT S 15 / Equivalent Ultima of Armstrong. Tile Type : Lay-in ceiling type System C ( Exposed Grid Ceiling ) Dimensions : 600 x 600 x 15 mm thick . Edge Detail : Bevelled Edge - VT S 15, Light Reflectance : upto 88%, Humidity Resistance : 95%, Colour : White Similar to RAL 9010, Surface Burning Characterstics : Class1, BS 476:Part 7:1987, Building Material Class A2-s1,d0 as per EN 13501-1, Thermal Conductivity : 0.052 - .057 W/mK, Sound Absorption : NRC = 0.70 as per ASTM C 423, Sound Attenuation : Dnfw = 31 dB as per EN 10848, Thickness / Weight : 3.6 Kg/m2
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Providing and fixing in true horizontal level approved make cellio Open Cell aluminium lay-in ceiling tiles with border panels forming flush-tegular/ board edge of size 600x 600x 35 mm having humidity resistance of 100% RH, and having fire performance Class 0/ Class 1 (BS 476). The tile of ‘global white’ color with cell size options of 75mm x 75mm. The grid should be of approved make with 15mm wide T section flanges colour white having rotary stitching on all T sections i.e. the main runner, 1200 & 600 mm cross tees with a web height of 43 mm and a load carrying capacity of 23.71 Kgs/ Sqm. The T sections have a galvanizing of 120 grams per Sqm & passed through 500 hrs of salt test. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using armstrong suspension system (specifications below) at 1200 mm maximum centre. The First/ Last armstrong suspension system at the end of each main runner should not be greater than 450 mm from the adjacent wall.
Providing and fixing wooden false ceiling using 18mm BWR ply finished with 1.0 mm thick Laminate of approved make and color and with groove lines in pattern as per the architectural drawings and instructions of the Engineer in charge. The wooden false ceiling shall be provided in combination with the gypsum/calcium silicate boards in different levels and the The work shall be inclusive of providing framework, adequate supports using 50mm x 25mm aluminium extrusions (both ways 600mm c/c) with necessary countersunk heavy duty screws, hardware and adhesives etc; and polished teakwood edge beadings to be provided as directed. Finished area of Laminated plywood will be measured fo the payment purpose
ACOUSTIC CLOUD CEILING :Suspension system & Installation: Supply and installation of Rockfon Eclipse island ceilings system using manufacturers proprietary suspension set comprising of Concrete fixing anchors, adjustable metal wire attached to the island with the use of a spiral anchor supplied by Rockfon. ROCKFON® Eclipse™ Island Ceiling should have ability to be installed up to a 45° angle. Membrane material: ROCKFON Eclipse® A Islands -Shape- Square in Size 1200 x 1200 mm and thickness 40 mm. Ecophon/ / Anutone / Saint gobian / Matrix or equivalent . Acoustics: Aeq (m2/Item) 1.02 Sound absorption is measured in accordance with ISO 354. Humidity resistance: Rockfon ceiling tiles dimensionally stable even at humidity levels of up to 100% RH that hat and can be installed at all temperatures ranging from 0°C to 40°C with no necesity of acclimatisation. Fire: Rockfon ceiling tiles have a non-combustible core of stone wool with a melting point of more than 1000°C. Reaction to fire: Class A1 in accordance with EN 13501-1. Light reflection: Standard White : Light reflection: 87%. Light diffusion: >99% in accordance with ISO 7724-2 Visual Appearance: Super white surface, L value: 94.5 in accordance with ISO 7724 , Deep matt surface, perfect in critical side-light, Gloss: 0.8 gloss unit at 85° angle in accordance with ISO 2813. Surface Durability: Enhanced durability and dirt resistance. Hygiene: Stone wool provides no sustenance to microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96 Environment : Fully recyclable Indoor Environment: Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low VOC emission products Approved manufacturer: Rockfon / Ecophon / Saint gobian / Matrix or equivalent
WALL ACOUSTIC : Perforated Wooden Slats - Melamine Laminated Supply & installation of perforated wooden grooved slats - FR grade, Slats L16-2 - (2mm Slats @16mm pitch) of size 128mm x 2430mm x 16mm thick made out of wood particle, Melamine laminated finish, backlined with acoustical fleece, fixed by using GI channel of 0.5mm thick having 21mm & 27mm width, height 18mm, having flanges of 7mm (installed horizontally -for vertical fixing of slats) spaced at 400mm centers with suitable brackets, GI 18mm channel is perpendicularly to the GI cross sectional channel of 0.45mm thk having a knurled web of 50mm width, height 22mm, having flanges of 15mm is then fixed to the Main channel with the help of connecting clip in direction perpendicular to the Main Channel at every 600mm centers main Channels of web 45mm x 0.9mm thick with two flanges of 15mm each from the soffit at every 1000mm centers with suspender angle of size 25mm x10mm x 0.45mm thick fixed to the soffit with G.I Cleat and metal fasteners as indicated in the drawing. The system is backlined with the acoustical infill synthetic polyfibre 25mm thick (SynthPF 10x25). The Perforated Wooden Slats ceiling module perimeter is covered with 12mm thick plywood with laminated finish, color as per the choice of Client / Architect, with necessary supports as indicated in the drawing Technical Parameters of the Perforated Wooden Slats - Melamine Laminated material • Fire – Class A • Acoustics –NRC 0.7 • Climate (OC, RH) – 50,70 • Termite resistance – Yes • Light – 75 % • Green – 25 % • Hygiene (VoC, Clean room) – Low, Class1 Rate inclusive of cost of all the materials, labour, scaffolding, installation and all taxes. Rates also inclusive of 50mm thick rockwool insulation with 48kg/cum. Finished area of flooring shall be measured in Sqm for payment. Note - Vendor to submit valid test certificates for the above mentioned technical parameters. Approved manufacturer: Anutone, Armstrong, Top akustic /RPG
Supply and installation of Anutone / Senses Stretch NRC wall fabric system by using FR Grade NRC fabric of size 1700mm width, shall be stretched by using wooden base 12mm thick, rigid vinyl Stretch Tracks half wrap / full wrap 15mm (FS15) and Midseam 15mm (FS15), strand board, synth PF infill with requisite accessories & tools. Strand square edge magnesite bonded pinewood fiber panels of size 600 x 1200 x 20mm having density 400kg/m3, weight 4kg which is fixed to wall with suitable fasteners. Synth PF 10 x10mm thick adhered on strand panel by using Stick 7 adhesive. Fabric of width 1700mm is then aligned to the Stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note - minimum 50mm additional fabric is required for tucking hence maximum module wall fabric width would be 1600mm. Rate shall inclusive cost of 50mm thick rockwool insulation with 48kg/cum Approved manufacturer: Anutone / Senses / Saint Gobain / Rockfon
Providing and fixing white matt finish white mark writing board of enamelled sheet steel front, GI back over approved inner core, of specified size black or chocolate colour wooden beading with polish finish to form the screen including the necessary accessories such as magnetic symbols, magnetic letters, magnetic strips, magnetic eraser, magnetic dry marker 4nos spare felt for eraser, board fixing clips etc. and the board shall be made out of enamelled sheet with backing of AC sheet to suitable thickness etc. complete and all as per manufacturer's specification and as directed by the Employer / Architect. Rate shall inclusive of making and fixing wooden ledge for full length of the board for keeping marker pen, eraser etc. Rate quoted shall be for the complete finished work including ledgeboard to keep accesories , and all materials and labour mentioned above.
Providing and fixing of 8mm thick lacquered glass of approved colour and make along with 12mm thick BWR plywood backing panel screw fixed over the existing partition, or wall panelling frame work or wall surfaces and using required area 3M make double side adhesive tapes. The rate shall be inclusive of necessary hardware, adhesive taps and wastage etc; complete.
Providing and fixing soft board panel of specified sizes having 12mm thick soft board with a 8mm thick BWR plywood backing and softboard covered with fabric of approved make and shade of premium quality and cost of fabric not less than Rs.300/1meter ht.1200mm). The board shall have a teakwood / cedar / beech / matching wooden beading, lipping around. The board shall be fixed with hook on system on the existing panelling or wall prepared surface with necessary hardware fittings etc. complete. All wood works shall have sealer polish as directed. Rate quoted shall be for the complete finished work including all the materials and labour mentioned above.
Providing and fixing of 3M frosted film of approved color as per required pattern and shape and as directed. The vendor shall submit required warranty certificates from the manufacture. (Basic cost Rs.1200/Sqm)
MOVABLE WALL SYSTEM Movable Walls :-GEZE ACOUSTIC SLIDING FOLDING PARTITION /DORMA / Equivalent Providing and Fixing of GEZE Movable Wall System with ST Vertical Panels and Adjustable Panels. The wall internal built is consisting of Steel Frame Galvanized with Aluminum profile. The frame must be clad either side with 15 mm quality chipboard panels hung in acoustic isolation from the frame and allowed to vibrate independently of the frame. The face panels must be easily removable. The panels must be filled with Acoustic Material Rockwool of high density 55 Kg / M³ to achieve Acoustic sound insulation of (50db). Each panel to have top and bottom Rubber Retractable Seal with 1500 Newton Force and concave / convex Vertical interlocking profiles. Each panel must be suspended on Extruded Aluminum ceiling mounted track. The rollers must be connected to the element via a shock absorbing mechanism. The individual element must be adjustable in height without opening of the ceiling.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in item of semi unitized system above) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. Vision Panel : Insulated Glass - 24 mm thick with 6 mm thick Reflective coated glass on # 2 surface - Planitherm (PLT TG) Mint Green as outer pane, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Both panes are heat strengthened. Rate shall exclude the cost of fixing of glass.
Providing & Fixing Aluminium composite panel 4mm thick with skin thickness of 0.5mm both side at service duct of the building, external/Internal surface like column, wall, jambs, sills, projected area, ceiling or any surface to any profile and shape, horizontally, vertically, sloped, curved, circular etc. complete and all support to be designed to withstand the Design wind pressure and the specification specified in Particular specifications etc. complete. Base M S support and aluminium frame work shall be measured under respective item separately. Rate shall be inclusive of all the operation involved, scaffolding for height up to 12 m, all wastages, labour, tools and plants, all taxes etc. but excluding M S Frame work and aluminium used for supporting panels.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with raw plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth,rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer‐in‐charge. : For fixed poirtion powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with raw plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth,rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer‐in‐charge. : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). A) Powder coated aluminum (minimum thickness of powder coating 50 micron)
Designing, providing and fixing aluminium Fixed window with Storm proof aluminium extruded louver "Z" type and fabricate the windows as per drawing and fixed at all levels, elevations and heights having a main frame work of vertical and horizontals, made out of locally extruded sections with thickness not less than 1.80mm to satisfied the structural design criteria specified in the technical specification. All aluminium sections shall be 63400 (H9) grade conforming to IS 8147, finished with exterior grade powder coating of thickness not less than 70 microns of approved colour. Rate shall include fixing the main frames into masonry wall / RC concrete surface with necessary clamps, fastening straps, nuts, bolts, rivets, washers and other fastening materials shall be in stainless steel or aluminium. Window shall be provided with monolithic glass of approved make and tint as given below and as per design for all panels and with snap fit aluminium colour anodized beading with special water proof cascades, Neoprene etc. complete, as directed. Necessary weather silicon sealant of Dow corning or approved equivalent make shall be provided at the junctions between wall and main frames. Rate shall include stainless steel safety clips to be provided on each corner of glass as an additional safety to avoid breakage of corner of the glass and also to be provided with EPDM / Neoprene triple barrier, extruded Reddiprone weather strip to ensure water and air tightness and shall include providing necessary accessories etc. complete all as directed. Rate shall also include for providing and fixing aluminium extruded aluminium 'L' angle ‐ 2.0mm thick with suitable size as per site or Alu. Sub frame of the section size of 14 mm height and width matching to the outer profile at around the window. System to be designed to with stand design wind pressure of 150 Kg/Sqm and other load parameters specified in the Technical specification. Support system to fix the Louver: Providing and fixing complete louver system having aluminium box frame, aluminium flat to receive the louvers and aluminium angles around the louvered window to protect the water ingress through the outer frame etc and to be designed to with stand design wind pressure specified. Note : Weight will be considered only for the assembled frame part and hence necessary wastage shall form part of the rate quoted.
Designing, providing and fixing aluminium Fixed window with Storm proof aluminium extruded louver "Z" type and fabricate the windows as per drawing and fixed at all levels, elevations and heights having a main frame work of vertical and horizontals, made out of locally extruded sections with thickness not less than 1.80mm to satisfied the structural design criteria specified in the technical specification. All aluminium sections shall be 63400 (H9) grade conforming to IS 8147, finished with exterior grade powder coating of thickness not less than 70 microns of approved colour. Rate shall include fixing the main frames into masonry wall / RC concrete surface with necessary clamps, fastening straps, nuts, bolts, rivets, washers and other fastening materials shall be in stainless steel or aluminium. Window shall be provided with monolithic glass of approved make and tint as given below and as per design for all panels and with snap fit aluminium colour anodized beading with special water proof cascades, Neoprene etc. complete, as directed. Necessary weather silicon sealant of Dow corning or approved equivalent make shall be provided at the junctions between wall and main frames. Rate shall include stainless steel safety clips to be provided on each corner of glass as an additional safety to avoid breakage of corner of the glass and also to be provided with EPDM / Neoprene triple barrier, extruded Reddiprone weather strip to ensure water and air tightness and shall include providing necessary accessories etc. complete all as directed. Rate shall also include for providing and fixing aluminium extruded aluminium 'L' angle ‐ 2.0mm thick with suitable size as per site or Alu. Sub frame of the section size of 14 mm height and width matching to the outer profile at around the window. System to be designed to with stand design wind pressure of 150 Kg/Sqm and other load parameters specified in the Technical specification. Fixed Louver: Providing and fixing Storm proof Louver ‐ Louver ‐ 75 x 28 x 1.5 mm thick section no 2089 ‐ weight not less than 0.464 Kg/Rmt "Z" type made out of specially extruded aluminium with powder coated finish and as specified in Particular specifications and to be fixed with pitch not less than 50 mm and overlapping shall be 25 mm as minimum as shown in the drawing. Rate shall include supply and fixing of Louver, but excluding cost frames, plates, L ‐ angle and other accessories, which shall part of Item above.
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer‐in charge . (Cost of aluminum snap beading shall be paid in basic item): With heat strengthened/toughened glass panes of 6 mm thickness (Plain)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer‐in charge . (Cost of aluminum snap beading shall be paid in basic item): With toughened glass panes of 8 mm thickness (Plain / Froasted)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer‐in charge . (Cost of aluminum snap beading shall be paid in basic item): With frosted toughened glass panes of 6 mm thickness at louvers / panels above door.
Designing, providing and fixing Punched / Strip window System (with Glass): Quote rate for complete system designing, providing and fixing structurally glazed punched / strip window system with structurally held in position by Structural sealant and factory fabricated with Aluminium adaptor of suitable size in order to satisfy the structural design criteria specified in the Technical specification. In general, the system comprising Aluminium anodized extruded frames & Adapters, aluminium sub frame & L ‐ Angle around the windows , Toggle cleats, HDG brackets & SS anchors and bolts (spanning 3.20 M as max), flashing & smoke seal around the window etc with Insulated Glass of 24 mm thick having Reflective coated glass ‐ ST 167 of Saint Gobain make or Spring (SC60/52) clear of Asahi make as outer pane and 12 mm airgap and 6 mm thick uncoated clear glass as inner pane of same make. Both panes are heat strengthened. Rate shall exclude the cost of top hung window hardwares and insulation, which will be measured and paid separately under the respective item below. Rate shall include the cost of supplying and fixing of glass, Top hung window hardwares, aluminium sub frame & L ‐ angle, visual mock up and field water test. System to be designed to with stand design wind pressure of 150Kg/Sqm confirming to IS 875 part 3 and other load parameters specified in Technical specification. Refer Particular Specification
Dismantling of existing Dry wall cladding with Clay tile including aluminium members etc complete and refixing the same on new wall with required missing members, fasteners, nuts and bolts and fixing plates etc complete as required. The Clay tile shall be fixed on the suitable farming system by using continuous aluminium anodized profiled section as per manufacturer with suitable size and spacing to withstand the Structural design criteria specified in the technical specification by using necessary Alum / HDG brackets, SS 316 grade anchor bolts etc as per manufacturer specification. Cladding joints shall be sealed with Gasket / open groove system. The size of clay tile shall be as per architectural requirement and the suitable fixing system shall be designed in accordance with the size of clay tile proposed in the drawing and to be designed to with stand design wind pressure of 125 Kg/Sqm conforming to IS 875 ‐ Part 3. Cladding the external surface to any surface, any profile and shape, horizontally, vertically, sloped, curved, circular etc by using Clay tile as given above. Jambs for glazing / windows & ventilators / doors and parapet copings are shall be considered with 2 mm thick aluminium PVDF finished sheet (exposed) fixed with SS 316 grade screws / rivet. The aluminium sheets shall have overlap of 100 to 125 mm in plan with sealant at joints to make sure that no water leakage through jambs / coping joints. Rate shall include the cost of all materials 2 mm thick aluminium PVDF finish SS screws / rivets, weather sealant and necessary accessories etc as per the manufacturer profile. Rate shall include the cost of all materials required for refixing of dry wall cladding like necessary framing system by using profiled aluminium sections, HDG brackets, SS anchors, weather sealant, 1.2 mm thick aluminium anodized flashing (un‐exposed) sheet at terrace & and all required levels and necessary accessories etc.
Supplying, Installing, testing and commissioning of White color Floor Mounted European water closet with integrated low level PVC flushing cistern and Wash Basin for Physically Challenged Persons (Matrix) with necessary Grab Rails, hinged rails for support , pan connecter bend,checknut, stopcock etc., colour solid seat and cover with polythene buffer and flap, CP flanges, CP bolts and nuts, bracket with nuts and bolts wall flanges etc.,complete, Wash Basin shall include 15mm dia CP liver operated pillar Cock with waste coupling, 32mm dia CP bottle trap with extension pipe,supporting bracket with necessary steel to support basin 1 No.15mm CP angle valve with 450mm long CP connection pipe and CP wall flanges all of approved make etc., complete. The cistern shall be complied water saving dual flush (6 to3 liter / flush) : Hind ware matrix set model no:70002 (or) equivalent
Providing, fixing, testing and commissioning White color urinal with automatic urinal flushing sensors. to be installed above urinal in the wall, solenoid valve in the incoming pipe line etc, including chasing and making good the walls,and floors wherever required all complete as per specification and direction of the Engineer-in-Charge.The electronic flushing system shall be discharge of water 0.40 liter per flush : Hindware Senso Art Sensor Urinal Set Size: 370 x 390 x 610 mm, model 60018 (or) equivalent including canceled type Urinal sensor with all accessories Hindware (or) equivalent including Jaquar CP bottle trap-Jaquar-Allied-model no:ALD-769 L 300x190 and waste coupling etc complete.
Supplying,installing,testing and commissioning of Long body bib cock for Janitor including necessary accessories etc.complete. The pillar tap shall be complied flow rate at 2.75 / lpm at design pressure of 80 psi. Jaquar-Long body bib cock model no: CON-107 KN
Providing , fixing, testing and commissioning stainless steel kitchen sink with drain board, 32mm dia CP waste coupling, 32mm dia CP bottle trap with extension pipe, 15mm CP angle valve with CP inlet connection tube , CP wall flange, including necessary brackets of approved make as mentioned below etc complete as per the direction of Engineer in charge. Nirali stainless steel sink with drai board size 510X1040 mm bowl depth 250 mm - Model – Elegance Jaquar Angle Cock - Model -FLR-5053N Jaquar Waste Coupling - Model - ALD-709 Jaquar CP bottle trap-Jaquar-Allied-model no:ALD-769 L 300x190
Providing and fixing CP sink cock with swivel spout floor mounted etc, including cutting and making good the walls wherever required etc., all complete as directed by Engineer Incharge. (For Pantary)The pillar tap shall be complied flow rate at 2.75 / lpm at design pressure of 80 psi : Jaquar -Sink cock with regular swivel spout model no FLR-5437
Supplying and fixing cp Double Coat hook fixing with necessary screws etc., complete : Jaquar double hook - Model -ACN-1161N
Supplying , fixing in position and testing C.P. health faucet with wall hook one metre long flexible tube, two way bib cock with wall flange all complete including cutting and making good the walls wherever required. (Jaquar CP Health Faucet ‐ Model ‐ 563 & Two way bib cock Jaquar FLR‐CHR‐5041N.)
Supplying and installing CP toilet paper holder fixed with SS screws complete. (Jaquar Continental toilet paper holder - Model -CAN-1153 S)
Providing and fixing liquid soap dispenser of approved make near wash basins with necessaryfixing screws and clamps etc., complete. (Jaquar - Soap dispenser Model No. SDR-WHT-DJ0010F)
Providng and fixing 600mm long CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arangement of approved quality colour and make .(Jaquar -towel Rail 600 mm long - Model no -ACN-1111 SM)
Supplying installing testing and commissioning Electric hand drier twin blower integrated with timer (0-3min) and infrared arrangement. The timer shall be fully automatic (Nova or equivalent)
Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with SS holding clamps and fixed in the walls over the tile face with necessary Screws etc.
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes &fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.:Internal work –Exposed on wall. : 32 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes &fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.:Internal work –Exposed on wall.: 40 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes &fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.:Internal work –Exposed on wall : 50 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes &fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.:Internal work –Exposed on wall : 62 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes &fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.:Internal work –Exposed on wall : 75 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement and cost of cutting chases and making good the same include testing of joints complete as per direction of Engineer in charge. : Concealed work including cutting chases and making good the wall etc. a) 15 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement and cost of cutting chases and making good the same include testing of joints complete as per direction of Engineer in charge. : Concealed work including cutting chases and making good the wall etc. b) 20 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement and cost of cutting chases and making good the same include testing of joints complete as per direction of Engineer in charge. : Concealed work including cutting chases and making good the wall etc. c) 25 mm nominal outer dia .pipes
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement and cost of cutting chases and making good the same include testing of joints complete as per direction of Engineer in charge. : Concealed work including cutting chases and making good the wall etc. d) 32 mm nominal outer dia .pipes
Supplying, fixing and testing of approved make equivalent Brass ball valve with necessary specials such as unions, flange etc.complete : 25 mm nominal bore
Supplying, fixing and testing of approved make equivalent Brass ball valve with necessary specials such as unions, flange etc.complete : 40 mm nominal bore
Supplying, fixing and testing of approved make equivalent Brass ball valve with necessary specials such as unions, flange etc.complete : 50 mm nominal bore
Supplying, fixing and testing of approved make equivalent Brass ball valve with necessary specials such as unions, flange etc.complete : 80 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal bore - Horizontal
Providing, fixing and testing UPVC SWR- B Class pipe of approved Make confirming to IS 13592-1992. and fittings confirming to IS 14735-1999, such as coupler, elbow, bends, Tee, Y, vent cowl etc for Soil, Waste,vent and rain water pipe works in shaft and suspended in ceiling., laid in ground( from shaft to Inspection chamber and Gully chamber), etc., using rubber ring joints(rubber ring confirming to IS 15382) for shafts lines and solvent cement joints for suspended lines and work in below ground. Woks includes necessary scaffolding,cutting and making good the walls wherever required all complete as directed by the Engineer-in-Charge. : 40mm dia
Providing, fixing and testing UPVC SWR- B Class pipe of approved Make confirming to IS 13592-1992. and fittings confirming to IS 14735-1999, such as coupler, elbow, bends, Tee, Y, vent cowl etc for Soil, Waste,vent and rain water pipe works in shaft and suspended in ceiling., laid in ground( from shaft to Inspection chamber and Gully chamber), etc., using rubber ring joints(rubber ring confirming to IS 15382) for shafts lines and solvent cement joints for suspended lines and work in below ground. Woks includes necessary scaffolding,cutting and making good the walls wherever required all complete as directed by the Engineer-in-Charge. : 75mm dia
Providing, fixing and testing UPVC SWR- B Class pipe of approved Make confirming to IS 13592-1992. and fittings confirming to IS 14735-1999, such as coupler, elbow, bends, Tee, Y, vent cowl etc for Soil, Waste,vent and rain water pipe works in shaft and suspended in ceiling., laid in ground( from shaft to Inspection chamber and Gully chamber), etc., using rubber ring joints(rubber ring confirming to IS 15382) for shafts lines and solvent cement joints for suspended lines and work in below ground. Woks includes necessary scaffolding,cutting and making good the walls wherever required all complete as directed by the Engineer-in-Charge. : 110mm dia
Supplying,fixing and testing of UPVC/ PVC floor trap with cockroach trap and CP grating 150 mm nominal size square 100mm diameter of the inner hinged round grating various inlet from 40 dia to 110 dia and various outlet from 75 dia to 100 dia with the extension pipe, boss tee connections, fixed in sunken floors /Suspended support with ceiling level etc., complete.
Supplying,fixing and testing of UPVC floor clean out used in sunken floors,75 or 110mm dia with extension pipes,specils such as 45 degrre bend , tee ,CP tile grating and end cap (clean out plug ).the cap arrangements with female thread fix with the upvc clean out plug in male thread with gascet and s.s screws etc. complete. Works including cutting and making good the walls /floor wherever required, etc., complete.
Supplying, fixing and testing of UPVC urinal trap with CP anti foul drainer square cockroach trap, 150 mm nominal size square 100mm diameter of the inner hinged round grating various inlet from 40 dia to 110 dia and various outlet from 75 dia to 100 dia with the extension pipe, boss tee connections, fixed in sunken floors /Suspended support with ceiling level etc., complete. Works including cutting and making good the walls /floor wherever required, etc., complete.
Fabricating,Supplying, fixing in position of Hot dipped Galvanized MS brackets made out of Angles, Channels, Flats and hot galvanized insert plates, according to the drawings at specified location at suitable intervals. The bracket shall be fixed both horizontally and vertically depending on the pipe locations such as shaft, ceiling, column faces and beam soffit etc. The rate shall include fixing the brackets/plates by using necessary size and dia of anchor fastners or any type fastening methodology approved by architect. The rate also include making cutouts/pockets in masonry wall to the suitable size in order to fix the bracket in wall and restore the finish after grouting the pocket with cement concrete etc. complete
NON WALKABLE FALSE CEILING : Providing and fixing approved make pre-fabricated insulated sandwich panels - overall 44mm thick double skin non-walk able false ceiling made of 0.8mm thick GPSP G.I. sheets with 60-80 micron epoxy polyester powder coating of approved color with infill material made up of PUF with density 40 kg/m3 or rockwool with density 90 kg/m3 with appropriate bonding system, to comply with minimum 1 hour fire rating. False ceiling panels should be designed with tongue and groove joints and suspended by minimum M8 or M10 hot dip galvanized rods adjustable suspension with turn buckles anchored to RCC slab/beam. Rate to include cost of all materials, all additional 'U' channel frames for light fixtures/ HVAC grills, preparation of shop drawings as per site conditions and getting approval of the same before manufacturing, including the cost of minor components/materials required for execution of the item complete as per direction of Engineer in charge. Plan area of finished false ceiling shall be measured for payment.
CLEAN ROOM WALL PANELS - 44mm : Providing and fixing approved make 44mm/80mm/100mm thick double skin progressive type with intermediate non progressive panels comprising of 2 sheets of 0.8mm thick GPSP G.I. sheets with 60-80 micron epoxy polyster powder coating of approved color with infill material comprising of Polyurethane Foam (PUF) with density of 40kg/cum or rockwool with density 90 kg/cum inclusive of adhesive/glue with appropriate bonding system, to comply with minimum 1 hour fire rating. Partition frame work shall be with aluminium stand alone profiles at panel joints with 1mm thick G.I. Stiftner channel sections at every 300mm between panels with all gaps and joints sealed with Dow corning 786 Silicone sealant for leak proof joints. Rate to include cost of additional frames for all cut-outs etc. Rate to include cost of all materials, additional channels around cut outs/ opening around light fixtures/ HVAC grills as per site conditions, preparation of shop drawings as per site conditions and getting approval of the same before manufacturing panels, including the cost of minor components/materials required for execution of the item complete as per direction of Engineer in charge. One side finished wall area shall be measured for payment. : 44 mm thick wall cladding panels.
CLEAN ROOM WALL PANELS - 80mm : Providing and fixing approved make 44mm/80mm/100mm thick double skin progressive type with intermediate non progressive panels comprising of 2 sheets of 0.8mm thick GPSP G.I. sheets with 60-80 micron epoxy polyster powder coating of approved color with infill material comprising of Polyurethane Foam (PUF) with density of 40kg/cum or rockwool with density 90 kg/cum inclusive of adhesive/glue with appropriate bonding system, to comply with minimum 1 hour fire rating. Partition frame work shall be with aluminium stand alone profiles at panel joints with 1mm thick G.I. Stiftner channel sections at every 300mm between panels with all gaps and joints sealed with Dow corning 786 Silicone sealant for leak proof joints. Rate to include cost of additional frames for all cut-outs etc. Rate to include cost of all materials, additional channels around cut outs/ opening around light fixtures/ HVAC grills as per site conditions, preparation of shop drawings as per site conditions and getting approval of the same before manufacturing panels, including the cost of minor components/materials required for execution of the item complete as per direction of Engineer in charge. One side finished wall area shall be measured for payment. : 44 mm thick wall cladding panels. : 80 mm thick wall panels.
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Wall to ceiling coving.
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Wall to floor.
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Wall to wall coving.
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Aluminium coving corner 3D (wall/wall/ceiling junction or floor junction)
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Aluminium coving corner 2D (wall to wall junction)
Hollow metal clean room steel door: Clean Room doors of size 1200 mm x 2100 mm Providing and fixing of Hollow metal clean room door from ISO 9001-2000 certified Manufacturer. The hollow metal doors should be made from high grade galvanized steel stretched level GPSP G.I sheet with double glazed vision panel. Single /Double leaf to required sizes and approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be single rebate profile of size 100 x 57 mm made out of 1.2 mm thick GPSP galvanized steel sheet (18 gauge ). Frames should be MITERED and field assembled with self tabs. Door frames should be prepared for suitable hardware as scheduled and should have necessary reinforcement to withstand regular wear and tear. All provision should be mortised, drilled and tapped for receiving the hardware. Rubber door silencers should be provided on the striking jamb. All door frames should be provided with SOFIT bracket and anchor fasteners for installation on clean room panels. Door shutter should be 44mm thick fully flush double skin door with vision panel. Door leaf shall be manufactured from 0.8mm (22 gauge) thick GPSP galvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb paper core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. Double glazed Vision panel shall be provided with 5mm thick toughened glass fixed with glazing tape flush with door shutter on either side. All doors and frames shall be finished with etched primer coating (35 microns), stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint (35 micron DFT) of approved colour. Steel surface should be blast cleaned to near to clean surface. Once the surface is cleaned the doors should be checked for finish before it is taken for painting. Clean Room doors of size 1200 mm x 2100 mm - List of hardware per door i) 3 nos Hinges SS 304 Ball bearing Butt hinge 100 mm x 75 mm x 3mm - 4330 of Dorma make. ii) 1 pair Handle SS 'D' pull handle - TG D1250mm x 19mm with back to back fixing iii) 1 no S.S. push plate. iv) 1 no of TS 68 Standard arm Door Closer of Dorma. v) 1 no S.S kick plate 0.8mm thick 1100x300. vi) 1no Mortise dead lock 278 with both sides key operation cylinder-Dorma. vii) 1 no View glass 400mm x 800mm double glazed view glass with 5mm thick toughened glass fixed with adhesive tape and silicon sealant all around. viii) Door seal with pvc gasket all around and Drop seal for air tightness.
Supply & Fixing of double glazed view panel with 5mm thick toughened glass 26.00 Sqm fixed flush with both sides of panel with high performance double coated pressure sensitive acrylic foam structural glazing tape like 3M VHB or equivalent. Frame work with 2mm thick aluminium, epoxy powder coated to 60 80 micron thickness; frame width to match panel thickness including providing silica gel desiccant arrangement and silicone sealant all around to make it air tight.
HVAC RISER : Supply and installing of Return air riser made of G.I sheet complete with S.S 100.00 Each 304 grade perforated grille, G4 filter and volume control damper fitted in module. The return air riser shall be adequately supported. Size of riser 600mm length x 150mm depth x 3250mm height.
Providing and fixing cut-outs in ceiling/wall panels for HEPA filters/HVAC grilles, cables, light fixtures including providing SS grille for HVAC cut-outs with necessary aluminum powder coated frames with beading and neoprene gaskets and silicon sealant so as to make the cut-out air tight. i) WALL CUT-OUT(supply air grille 300/500x150mm)
Providing and fixing cut-outs in ceiling/wall panels for HEPA filters/HVAC grilles, cables, light fixtures including providing SS grille for HVAC cut-outs with necessary aluminum powder coated frames with beading and neoprene gaskets and silicon sealant so as to make the cut-out air tight. ii) CEILING CUT-OUT(Light fixture/ac diffuser 600x600mm)
Providing and fixing cut-outs in ceiling/wall panels for HEPA filters/HVAC grilles, cables, light fixtures including providing SS grille for HVAC cut-outs with necessary aluminum powder coated frames with beading and neoprene gaskets and silicon sealant so as to make the cut-out air tight. iii) 25 to 75mm dia holes for cables.
Providing and installing of Vinyl Sheet Flooring manufactured by Armstrong , Forbo, Tarkett or equivalent in roll form , size 1.83 m wide, having a nominal total thickness of 2mm. All joints between vinyl sheets shall be bot seamed/welded using multi-coloured welding rod to match flooring colour after 24 hours of laying of rolls. Welding and seaming shall be done using automatic hot seam welding machine. Rate to include protection with 500 micron LDPE sheet with taped edges until completion of all other activities as the floor as per the instructions of Engineer in charge. Vinyl sheets should be laid over 2 to 3 mm thick self levelling base with cementitious self levelling compound, Ardite K15, Epocem or equivalent to get an even sub floor. Vinyl sheets shall be manufactured as per CE norms and EN 14041 :2004 05.
L.T. SWITCHGEAR ASSEMBLE (L.T PANELS BOARDS) PANEL REFERENCE : UPS POWER LOAD PANEL-01 & 02 FOR 4 th & 5th FLOOR PHYSICS LAB refer Following Details & SLD Drawing No:- IISER/CRN/EMEA/SLD/EL/02 Tender specifications data sheet. Supplying, Transportation ,installation, testing & commissioning loading & unloading of cubical type LT panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartmentalized Form 3A design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 3200Amp,36KAfor 1sec, Degree of protection -IP 52,Type of construction/ form - Compaetmentalised, Extensible, Dust & Vermin Proof. a) Incoming Section as under : (a.1) Incomers MCCB :- 250 A 4P MCCB (Fixed type 35KA -1 Second with Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSIG) with Digital Disply , Shunt Trip Release : 1 Number (a.2) Control MCB 6A , Class-C as shown on SLD : (a.3) Indications : LED Indication : RYB for Phase & ON/OFF/TRIP/ & required control MCB as shown on SLD - For each incomer a.5) 3 CT Operated Digital Microprocessor Load Manager for Line Voltage ,Phase voltage , current ,KW, KVA, KWH, KVAH,KVARH, Hz, TDH, with RS 485 Serial commumnication Port.(a.6) Resin Cast Current Transformers : Ratio as mention under (a6.1) 1 set of 3 Nos. 250 / 5 A ,15 VA CL:1 CT’s for Metering : for incomer B) Outgoings feeders as under Type of Feeders : TP&N Moulded Case Circuit Breaker (MCCB) Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSG) Rating of Outgoings feeders: (b.2.1) 63 Amp 36KA TPN MCCB :- 12 Numbers (b.2.2) 125 Amp 36KA TPN MCCB:- 01 Numbers(b.2.3) 32 Amp 36KA TPN MCCB:- 04 Numbers b.2 : Indications : LED ON/OFF/TRIP Indication for each outgoings b.5 )Resin Cast Current Transformers : Ratio as mention under for metering b.5.1 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,60/ 5 Amp :- Quantity :- 12Nos b.5.2 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,125/ 5 Amp :-Quantity :- 1Nosb.5.3 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,32/ 5 Amp :- Quantity :- 4Nosb.6) : Operating Handle ; Each MCCB shall be provided with extended type Rotary Handel mounted on front door with Padlock arrangement for each feederc) Interface with BMS : Followings wiring terminals shall be provided for Centralized BMS connectivity for each Incoming and outgoing feeders duly wired with 0.5 mm dia Cu anneled conductor , twisted pair Screen wired to suitable terminals ) c.1 : ON Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.2 : OFF Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.3 : Trip on Fault Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.4: RS 485 Serial port of all Incoming and Outgoings Minimum 12 Meters shall be wired in dezy link ready to use , interface with BMS connectivity ( For Software Integrations of Meters with BMS ) c.5: Marshelling compartment with terminals for all BMS input & output cable termination with identification tag shall be provided ) Busbars as under d.1) Main Horizontal Busbar : 400A TP & N Aluminum 35 K.A. 1-Sec , busbar at current density of 0.8 Amp /Sq.mm for each bus sectiond.2) Vertical TPN Busbar : Amp rating of Vertical TPN Busbar shall be Sum of total connected Feeder at current density of 0.8 Amp /Sq.mm Refer SLD Number :- IISER/CRN/EMEA/SLD/EL/02
L.T. SWITCHGEAR ASSEMBLE (L.T PANELS BOARDS) PANEL REFERENCE : UPS POWER LOAD PANEL-01 & 02 FOR Quantum Lab PHYSICS LAB refer Following Details & SLD Drawing No:- IISER/CRN/EMEA/SLD/EL/02 Tender specifications data sheet. Supplying, Transportation ,installation, testing & commissioning loading & unloading of cubical type LT panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartmentalized Form 3A design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 3200Amp,36KAfor 1sec Degree of protection -IP 52,Type of construction/ form - Compaetmentalised, Form -3b Extensible, Dust & Vermin Proof.. a) Incoming Section as under : (a.1) Incomers MCCB :- 250 A 4P MCCB (Fixed type 35KA -1 Second with Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSIG) with Digital Disply , Shunt Trip Release : 1 Number (a.2) Control MCB 6A , Class-C as shown on SLD : (a.3) Indications : LED Indication : RYB for Phase & ON/OFF/TRIP/ & required control MCB as shown on SLD - For each incomer a.5) 3 CT Operated Digital Microprocessor Load Manager for Line Voltage ,Phase voltage , current ,KW, KVA, KWH, KVAH,KVARH, Hz, TDH, with RS 485 Serial commumnication Port.(a.6) Resin Cast Current Transformers : Ratio as mention under (a6.1) 1 set of 3 Nos. 250 / 5 A ,15 VA CL:1 CT’s for Metering : for incomer B) Outgoings feeders as under Type of Feeders : TP&N Moulded Case Circuit Breaker (MCCB) Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSG) Rating of Outgoings feeders: (b.2.1) 63 Amp 36KA TPN MCCB :- 06 Numbers (b.2.2) 125 Amp 36KA TPN MCCB:- 01 Numbers(b.2.3) 32 Amp 36KA TPN MCCB:- 04 Numbers b.2 : Indications : LED ON/OFF/TRIP Indication for each outgoings b.5 )Resin Cast Current Transformers : Ratio as mention under for metering b.5.1 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,60/ 5 Amp :- Quantity :- 6Nos b.5.2 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,125/ 5 Amp :-Quantity :- 1Nosb.5.3 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,250/ 5 Amp :- Quantity :- 4Nosb.6) : Operating Handle ; Each MCCB shall be provided with extended type Rotary Handel mounted on front door with Padlock arrangement for each feederc) Interface with BMS : Followings wiring terminals shall be provided for Centralized BMS connectivity for each Incoming and outgoing feeders duly wired with 0.5 mm dia Cu anneled conductor , twisted pair Screen wired to suitable terminals ) c.1 : ON Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.2 : OFF Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.3 : Trip on Fault Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.4: RS 485 Serial port of all Incoming and Outgoings Minimum 12 Meters shall be wired in dezy link ready to use , interface with BMS connectivity ( For Software Integrations of Meters with BMS ) c.5: Marshelling compartment with terminals for all BMS input & output cable termination with identification tag shall be provided ) Busbars as under d.1) Main Horizontal Busbar : 400A TP & N Aluminum 35 K.A. 1-Sec , busbar at current density of 0.8 Amp /Sq.mm for each bus sectiond.2) Vertical TPN Busbar : Amp rating of Vertical TPN Busbar shall be Sum of total connected Feeder at current density of 0.8 Amp /Sq.mm Refer SLD Number :- IISER/CRN/EMEA/SLD//EL/02
L.T. SWITCHGEAR ASSEMBLE (L.T PANELS BOARDS) PANEL REFERENCE : Non Essential Load Panel at 4th floor PHYSICS LAB refer Following Details & SLD Drawing No:- IISER/CRN/EMEA/SLD/EL/01 Tender specifications data sheet. Supplying, Transportation ,installation, testing & commissioning loading & unloading of cubical type LT panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartmentalized Form 3A design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 3200Amp,36KAfor 1sec Degree of protection -IP 52,Type of construction/ form - Compaetmentalised, Form -3b Extensible, Dust & Vermin Proof.. a) Incoming Section as under : (a.1) Incomers MCCB :- 400 A 4P MCCB (Fixed type 35KA -1 Second with Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSIG) with Digital Disply , Shunt Trip Release : 1 Number (a.2) Control MCB 6A , Class-C as shown on SLD : (a.3) Indications : LED Indication : RYB for Phase & ON/OFF/TRIP/ & required control MCB as shown on SLD - For each incomer a.5) 3 CT Operated Digital Microprocessor Load Manager for Line Voltage ,Phase voltage , current ,KW, KVA, KWH, KVAH,KVARH, Hz, TDH, with RS 485 Serial commumnication Port.(a.6) Resin Cast Current Transformers : Ratio as mention under (a6.1) 1 set of 3 Nos. 400 / 5 A ,15 VA CL:1 CT’s for Metering : for incomer B) Outgoings feeders as under Type of Feeders : TP&N Moulded Case Circuit Breaker (MCCB) Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSG) Rating of Outgoings feeders: (b.2.1) 125 Amp 36KA TPN MCCB :- 05 Numbers b.2 : Indications : LED ON/OFF/TRIP Indication for each outgoings b.5 )Resin Cast Current Transformers : Ratio as mention under for metering b.5.1 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,60/ 5 Amp :- Quantity :- 0Nos b.5.2 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,125/ 5 Amp :-Quantity :- 5Nosb.5.3 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,250/ 5 Amp :- Quantity :- 0Nosb.6) : Operating Handle ; Each MCCB shall be provided with extended type Rotary Handel mounted on front door with Padlock arrangement for each feederc) Interface with BMS : Followings wiring terminals shall be provided for Centralized BMS connectivity for each Incoming and outgoing feeders duly wired with 0.5 mm dia Cu anneled conductor , twisted pair Screen wired to suitable terminals ) c.1 : ON Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.2 : OFF Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.3 : Trip on Fault Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.4: RS 485 Serial port of all Incoming and Outgoings Minimum 12 Meters shall be wired in dezy link ready to use , interface with BMS connectivity ( For Software Integrations of Meters with BMS ) c.5: Marshelling compartment with terminals for all BMS input & output cable termination with identification tag shall be provided ) Busbars as under d.1) Main Horizontal Busbar : 400A TP & N Aluminum 35 K.A. 1-Sec , busbar at current density of 0.8 Amp /Sq.mm for each bus sectiond.2) Vertical TPN Busbar : Amp rating of Vertical TPN Busbar shall be Sum of total connected Feeder at current density of 0.8 Amp /Sq.mm Refer SLD Number :- IISER/CRN/EMEA/SLD/EL/01
L.T. SWITCHGEAR ASSEMBLE (L.T PANELS BOARDS) PANEL REFERENCE : 5th floor AC panel PHYSICS LAB refer Following Details & SLD Drawing No:- IISER/CRN/EMEA/SLD/EL/03 Tender specifications data sheet. Supplying, Transportation ,installation, testing & commissioning loading & unloading of cubical type LT panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartmentalized Form 3A design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 3200Amp,36KAfor 1sec , Degree of protection -IP 52,Type of construction/ form - Compaetmentalised, Extensible, Dust & Vermin Proof a) Incoming Section as under : (a.1) Incomers MCCB :- 250 A 4P MCCB (Fixed type 35KA -1 Second with Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSIG) with Digital Disply , Shunt Trip Release : 1 Number (a.2) Control MCB 6A , Class-C as shown on SLD : (a.3) Indications : LED Indication : RYB for Phase & ON/OFF/TRIP/ & required control MCB as shown on SLD - For each incomer a.5) 3 CT Operated Digital Microprocessor Load Manager for Line Voltage ,Phase voltage , current ,KW, KVA, KWH, KVAH,KVARH, Hz, TDH, with RS 485 Serial commumnication Port.(a.6) Resin Cast Current Transformers : Ratio as mention under (a6.1) 1 set of 3 Nos. 250 / 5 A ,15 VA CL:1 CT’s for Metering : for incomer B) Outgoings feeders as under Type of Feeders : TP&N Moulded Case Circuit Breaker (MCCB) Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSG) Rating of Outgoings feeders: (b.2.1) 63 Amp 36KA TPN MCCB :- 06 Numbers (b.2.2) 32 Amp 36KA TPN MCB Miniature Circuit breaker :- 16 Numbers b.2 : Indications : LED ON/OFF/TRIP Indication for each outgoings b.5 )Resin Cast Current Transformers : Ratio as mention under for metering b.5.1 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,60/ 5 Amp :- Quantity :- 6Nos b.5.2 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,125/ 5 Amp :-Quantity :- 0Nosb.5.3 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,32/ 5 Amp :- Quantity :- 16 Nosb.6) : Operating Handle ; Each MCCB shall be provided with extended type Rotary Handel mounted on front door with Padlock arrangement for each feederc) Interface with BMS : Followings wiring terminals shall be provided for Centralized BMS connectivity for each Incoming and outgoing feeders duly wired with 0.5 mm dia Cu anneled conductor , twisted pair Screen wired to suitable terminals ) c.1 : ON Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.2 : OFF Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.3 : Trip on Fault Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.4: RS 485 Serial port of all Incoming and Outgoings Minimum 12 Meters shall be wired in dezy link ready to use , interface with BMS connectivity ( For Software Integrations of Meters with BMS ) c.5: Marshelling compartment with terminals for all BMS input & output cable termination with identification tag shall be provided ) Busbars as under d.1) Main Horizontal Busbar : 400A TP & N Aluminum 35 K.A. 1-Sec , busbar at current density of 0.8 Amp /Sq.mm for each bus sectiond.2) Vertical TPN Busbar : Amp rating of Vertical TPN Busbar shall be Sum of total connected Feeder at current density of 0.8 Amp /Sq.mm Refer SLD Number :- IISER/CRN/EMEA/SLD/EL/03
L.T. SWITCHGEAR ASSEMBLE (L.T PANELS BOARDS) PANEL REFERENCE : 5th floor Sub essential panel PHYSICS LAB refer Following Details & SLD Drawing No:- IISER/CRN/EMEA/SLD/EL/01 Tender specifications data sheet. Supplying, Transportation ,installation, testing & commissioning loading & unloading of cubical type LT panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartmentalized Form 3A design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 3200Amp,36KAfor 1sec Degree of protection -IP 52,Type of construction/ form - Compaetmentalised, Form -3b Extensible, Dust & Vermin Proof.. a) Incoming Section as under : (a.1) Incomers MCCB :- 400 A 4P MCCB (Fixed type 35KA -1 Second with Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSIG) with Digital Disply , Shunt Trip Release : 1 Number (a.2) Control MCB 6A , Class-C as shown on SLD : (a.3) Indications : LED Indication : RYB for Phase & ON/OFF/TRIP/ & required control MCB as shown on SLD - For each incomer a.5) 3 CT Operated Digital Microprocessor Load Manager for Line Voltage ,Phase voltage , current ,KW, KVA, KWH, KVAH,KVARH, Hz, TDH, with RS 485 Serial commumnication Port.(a.6) Resin Cast Current Transformers : Ratio as mention under (a6.1) 1 set of 3 Nos. 400 / 5 A ,15 VA CL:1 CT’s for Metering : for incomer B) Outgoings feeders as under Type of Feeders : TP&N Moulded Case Circuit Breaker (MCCB) Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSG) Rating of Outgoings feeders: (b.2.1) 250 Amp 36KA TPN MCCB :- 06 Numbers (b.2.2) b.2 : Indications : LED ON/OFF/TRIP Indication for each outgoings b.5 )Resin Cast Current Transformers : Ratio as mention under for metering b.5.1 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,250/ 5 Amp :- Quantity :- 6Nos b.5.2 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,125/ 5 Amp :-Quantity :- 0Nosb.5.3 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,250/ 5 Amp :- Quantity :- 0Nosb.6) : Operating Handle ; Each MCCB shall be provided with extended type Rotary Handel mounted on front door with Padlock arrangement for each feederc) Interface with BMS : Followings wiring terminals shall be provided for Centralized BMS connectivity for each Incoming and outgoing feeders duly wired with 0.5 mm dia Cu anneled conductor , twisted pair Screen wired to suitable terminals ) c.1 : ON Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.2 : OFF Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.3 : Trip on Fault Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.4: RS 485 Serial port of all Incoming and Outgoings Minimum 12 Meters shall be wired in dezy link ready to use , interface with BMS connectivity ( For Software Integrations of Meters with BMS ) c.5: Marshelling compartment with terminals for all BMS input & output cable termination with identification tag shall be provided ) Busbars as under d.1) Main Horizontal Busbar : 400A TP & N Aluminum 35 K.A. 1-Sec , busbar at current density of 0.8 Amp /Sq.mm for each bus sectiond.2) Vertical TPN Busbar : Amp rating of Vertical TPN Busbar shall be Sum of total connected Feeder at current density of 0.8 Amp /Sq.mm Refer SLD Number :- IISER/CRN/EMEA/SLD/EL/01
L.T. SWITCHGEAR ASSEMBLE (L.T PANELS BOARDS) PANEL REFERENCE : Essential floor panel 4th and 5th floor PHYSICS LAB refer Following Details & SLD Drawing No:- IISER/CRN/EMEA/SLD/EL/03 Tender specifications data sheet. Supplying, Transportation ,installation, testing & commissioning loading & unloading of cubical type LT panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartmentalized Form 3A design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 3200Amp,36KAfor 1sec, Degree of protection -IP 52,Type of construction/ form - Compaetmentalised, Extensible, Dust & Vermin Proof a) Incoming Section as under : (a.1) Incomers MCCB :- 250 A 4P MCCB (Fixed type 35KA -1 Second with Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSIG) with Digital Disply , Shunt Trip Release : 1 Number (a.2) Control MCB 6A , Class-C as shown on SLD : (a.3) Indications : LED Indication : RYB for Phase & ON/OFF/TRIP/ & required control MCB as shown on SLD - For each incomer a.5) 3 CT Operated Digital Microprocessor Load Manager for Line Voltage ,Phase voltage , current ,KW, KVA, KWH, KVAH,KVARH, Hz, TDH, with RS 485 Serial commumnication Port.(a.6) Resin Cast Current Transformers : Ratio as mention under (a6.1) 1 set of 3 Nos. 250 / 5 A ,15 VA CL:1 CT’s for Metering : for incomer B) Outgoings feeders as under Type of Feeders : TP&N Moulded Case Circuit Breaker (MCCB) Inbuilt Adjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth fault release (LSG) Rating of Outgoings feeders: (b.2.1) 63 Amp 36KA TPN MCCB :- 15 Numbers (b.2.2) b.2 : Indications : LED ON/OFF/TRIP Indication for each outgoings b.5 )Resin Cast Current Transformers : Ratio as mention under for metering b.5.1 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,60/ 5 Amp :- Quantity :- 15Nos b.5.2 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,125/ 5 Amp :-Quantity :- 0Nosb.5.3 ) 1 Set of 3 Nos CTs with 15 VA CL:1 ,250/ 5 Amp :- Quantity :- 0Nosb.6) : Operating Handle ; Each MCCB shall be provided with extended type Rotary Handel mounted on front door with Padlock arrangement for each feederc) Interface with BMS : Followings wiring terminals shall be provided for Centralized BMS connectivity for each Incoming and outgoing feeders duly wired with 0.5 mm dia Cu anneled conductor , twisted pair Screen wired to suitable terminals ) c.1 : ON Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.2 : OFF Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.3 : Trip on Fault Status of Circuit Breaker to BMS -(Potential Free Contact from C.B. c.4: RS 485 Serial port of all Incoming and Outgoings Minimum 12 Meters shall be wired in dezy link ready to use , interface with BMS connectivity ( For Software Integrations of Meters with BMS ) c.5: Marshelling compartment with terminals for all BMS input & output cable termination with identification tag shall be provided ) Busbars as under d.1) Main Horizontal Busbar : 400A TP & N Aluminum 35 K.A. 1-Sec , busbar at current density of 0.8 Amp /Sq.mm for each bus sectiond.2) Vertical TPN Busbar : Amp rating of Vertical TPN Busbar shall be Sum of total connected Feeder at current density of 0.8 Amp /Sq.mm Refer SLD Number :- IISER/CRN/EMEA/SLD/EL/03
MV Cable Laying: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
MV Cable Laying: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
MV Cable Jointing & End Termination : Supplying and making indoor end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed /XLPE aluminum conductor cables of 1.1kV grade as required.3½ X 185 sq. mm (57mm)
MV Cable Jointing & End Termination : Supplying and making indoor end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed /XLPE aluminum conductor cables of 1.1kV grade as required.3½ X 300 sq. mm (70mm)
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required4 x 16 Sq.mm Copper ,XLPE Armourd Cable
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required4 x 6Sq.mm Copper ,XLPE Armourd Cable
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required4 x 4Sq.mm Copper ,XLPE Armourd Cable
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required4 x 2.5Sq.mm Copper ,XLPE Armourd Cable
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required3 x 4Sq.mm Copper ,XLPE Armourd Cable
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required3X2.5 sq.mm Copper ,XLPE Armourd Cable
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required1 xCore x25 Sq.mm Cu FlexibleUnarmoured FLRS
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required1 xCore x16 Sq.mm Cu FlexibleUnarmoured FLRS (Green Outersheath)
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required4C X 2.5Sq.mm. CU-Armoured PVC Insulated Flexibale Multicore
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required4X25 sq.mm Copper ,XLPE Armourd Cable
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required1 xCore x 06 Sq.mm Copper Flexible FLRS (Green Outersheath)
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required1 xCore x 70 Sq.mm Copper Flexible FLRS (Green Outersheath)
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required1 xCore x 95 Sq.mm Copper Flexible FLRS (Green Outersheath)
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required 3 xCore x 16 Sq.mm Copper armoured cable
Supply Of M.V. Cables : Supply, loading, transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XPLE insulated over all FRLS outersheathed , Aluminium conductor, armoured LT power cables as per IS 7098(Part 1) of following sizes.( Note :- Cable shall be considered Round armoured type )3 1/2 x 300 sq.mm ALuminium ,XLPE Armourd Cable
Supply Of M.V. Cables : Supply, loading, transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XPLE insulated over all FRLS outersheathed , Aluminium conductor, armoured LT power cables as per IS 7098(Part 1) of following sizes.( Note :- Cable shall be considered Round armoured type )3 1/2 x 185 sq.mm ALuminium ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )4X16 sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )4X6 sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )4X4 sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )4X2.5 sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )3X2.5 sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )1 xCore x25 Sq.mm Copper Flexible FLRS Cables
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )1 xCore x16 Sq.mm Copper Flexible FLRS (Green Outersheath)
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )4C X 2.5Sq.mm. CU-Armoured PVC Insulated Flexibale Multicore
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )4X25 sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type )1 xCore x 06 Sq.mm Copper Flexible FLRS (Green Outersheath)
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .1 xCore x 70 Sq.mm Copper Flexible FLRS (Green Outersheath)
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .1 xCore x 95 Sq.mm Copper Flexible FLRS (Green Outersheath)
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .3 xCore x 16 Sq.mm Copper aremoured cable FLRS
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable
CABLE TRAY :Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
CABLE TRAY :Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness
CABLE TRAY :Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness
CABLE TRAY :Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.750 mm width X 62.5 mm depth X 2.0 mm thickness
Supply, fabrication and installation of cable tray supports, supports for cable trench covers, supporting frame for mounting of control panels, supports for mounting of local control station,Main Electrical Panel,lighting panel, lighting fixture etc. with 2 coats of enemel primer and 2 coats of epoxy paint Note - The rates shall be inclusive of grouting of supports , Anchor fastner,welding rods, nut,bolts,clamps,and any other consumable which required to complete the works.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.750 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.750 mm width X 62.5 mm depth X 2.0 mm thickness
UNDER FLOOR TRUCKING Supply & Installation of AL 2 mm Thick underfloor trunking (Race Way ) Box type including Staright Run , Coupling Plates, Cutting of the floor by diamond cutter , & cleaning the floor inclunding disbursemnet of removed Floor materials, making good to floor after fixing of Underfloor Trunking .( or Power , UPS, Data & voice) straight Run 300X300X38mm
UNDER FLOOR TRUCKING Supply & Installation of AL 2 mm Thick underfloor trunking (Race Way ) Box type including Staright Run , Coupling Plates, Cutting of the floor by diamond cutter , & cleaning the floor inclunding disbursemnet of removed Floor materials, making good to floor after fixing of Underfloor Trunking .( or Power , UPS, Data & voice) straight Run200X200X38mm
UNDER FLOOR TRUCKING Supply & Installation of AL 2 mm Thick underfloor trunking (Race Way ) Box type including Staright Run , Coupling Plates, Cutting of the floor by diamond cutter , & cleaning the floor inclunding disbursemnet of removed Floor materials, making good to floor after fixing of Underfloor Trunking .( or Power , UPS, Data & voice) straight Run100X100X38mm
Supply & fixing Junction boxes for item Sr, in M section of following sizes including fixing& cutting & making good to floor as stated above350 x 350 x 50 mm- 4 Way G.I.2mm J.B. with stainless steel cover
Supply & fixing Junction boxes for item Sr, in M section of following sizes including fixing& cutting & making good to floor as stated . bove250 x 250 x 50 mm- 4 Way G.I.2mm J.B. with stainless steel cover
Supply & fixing Junction boxes for item Sr, in M section of following sizes including fixing& cutting & making good to floor as stated bove150 x 150 x 50 mm- 4 Way G.I.2mm J.B. with stainless steel cover
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
EARTHING SYSTEM : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
EARTHING SYSTEM: Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
EARTHING SYSTEM :Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
EARTHING SYSTEM :Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
EARTHING SYSTEM :Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way (4 +36), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB where 3 phase outlets are required.) 6 way (4 + 12), Double door
MCCB,MCB&DB'S Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
MCCB,MCB&DB'S Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. FOUR pole
MCCB,MCB&DB'S Supplying and fixing 16 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Tripal pole
MCCB,MCB&DB'S Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Tripal pole
Supplying and fixing following 40 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing andcommissioning etc. asrequired. 40A
Supplying and fixing following 63 A rating, Four pole, (Three phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing andcommissioning etc. asrequired. 63A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith 63 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 415 V "C" curve 4POLE MCB complete with connections, testing and commissioning etc. as required for following rating.32A MCB,4POLE 10KA,D-CL
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 415 V "C" curve 4POLE MCB complete with connections, testing and commissioning etc. as required for following rating.63A MCB,4POLE 10KA,D-CL
Supply and installation of MCCB enclosuser box with 250 A 4 pole 36 kA MCCB having required accessories, mouting , handle etc as complete, enclosuer should be suitable for termination of 3.5 c x 300 sqmm cable at both end of MCCB. Duly painted and having wall mounting arrangment . cable entery top and bottom, as complete.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supply and laying of HDPE PLB duct pipe/conduit 40 mm dia in open duct / tray / on surface with clamp / in ground as complete.
Supply & fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc as required.1 or 2 Module box (75mmx75 mm)(For Power socket/ELV Purpose)
Supply & fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc as required.3 Module box(100mmx75 mm)(For Power socket/ELV Purpose)
Supply & fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc as required.4 Module box(125mmx75 mm)(For Power socket/ELV Purpose)
Supply & fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc as required.6 Module box(200mmx75 mm)(For Power socket/ELV Purpose)
Supply & fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc as required. 8 Module box(125mmx125 mm) (For Power socket/ELV Purpose)
Supply & fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc as required. 12 Module box(200mmx150 mm)(For Power socket/ELV Purpose)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 3 Module (For Power socket/ELV Purpose)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 4 Module (For Power socket/ ELV Purpose)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 6 Module (For Power socket/ ELV Purpose)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 8 Module (For Power socket/ ELV Purpose)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 12 Module (For Power socket/ELV Purpose)
Supply & fixing following modular switch/ Socket on the exisiting modular plate & switch box including connection but excluding modular plate etc. as required 5/6 amps switch (For Power socket)
Supply & fixing following modular switch/ Socket on the exisiting modular plate & switch box including connection but excluding modular plate etc. as required : 15/16 amp switch (For Power socket)
Supply & fixing following modular switch/ Socket on the exisiting modular plate & switch box including connection but excluding modular plate etc. as required : 3 pin 5/6 amp socket outlet (For Power socket)
Supply & fixing following modular switch/ Socket on the exisiting modular plate & switch box including connection but excluding modular plate etc. as required : 6 pin 15/16 amp socket outlet (For Power socket)
Supply and fixing modular blanking plate on the exisitng modular plate & switch box with matching colour including connection but excluding modular plate etc as required.
Supply & installation of surface mounted DLP U- PVC adaptable trunking raceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with removable covers, complete with necessary bends, suitable sized junction boxes, internal angle, external angle, flat 90 degree angle , end caps and tees etc, Complete. (For every 1mtr distance cable tag has to be provided for each circuit in the raceways - as more that 1C FRLS copper wire is required for 1 Circuit) PVC RACEWAYS ( Along the wall), DLP U- PVC adaptable trunking . Size: 105x 50mm PVC Raceways for Power & Data with above specifications
Supplying and fixing following Modular base & cover plate ( Clip on support for mounting switches etc) on existing DLP U PVC trunking etc. as required. 2 module 85 mm
Supplying and fixing following Modular base & cover plate ( Clip on support for mounting switches etc) on existing DLP U PVC trunking etc. as required. 4 module 85 mm
Supplying and fixing following Modular base & cover plate ( Clip on support for mounting switches etc) on existing DLP U PVC trunking etc. as required. 6 module 85 mm
Supply and fixing of seperation partition 85 mm in existing DLP U PVC trunking as required.
Supply and fixing of 8 Module ( 2x4 ) Pop up type flush mounting boxes with required accessories for fixing it into wooden furniture/table, cable enteries etc. Slim design and colour should be suitable for furniture. Make Legrand
Supply of ceiling fan, 1400 mm, having rotor, 3 blades, downrod, caps , wires, white painted, 230 V AC , having full accessories for safe standard installation, as complete. Make Bajaj / Usha / CG
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply, of Exhaust fan 150mm light duty 230 V AC 50 Hz 450 mm 1400 RPM with condenser complete erected in position with n/c materials Fan motor with moisture treatment and class E insulation & With bird protective screen
Supply, loading ,transportation, unloading at site, storages at site of Braket fan Fan 400 mm sweep A.C 230V 15 cycle 1350RPM Oscillating type plastic or metal blades chromeplated guard with regulator and moiture proof treatement to winding & with E Class insulation & marking sr no date of installation
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/Angle holder including connection etc.as required
Supply ,installtion,testing commissioning of Air Circulatr fan , 88*20MM Copper winding motor, double ball bearing, 220-240V Volatge, Power- 65W+-5%, Auto-on Function, 3Nos. ABS blades, 3 speed with remote control. Equivalent to ECO air model no. EAAC 01
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. . LIGHTING LUMINARS Supply Testing commissioning of Recessed Mounted 2'X2' LED Luminaire with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire. Luminaire should give more volumetric light & higher vertical illumination.Luminaire should be available in different Lumen Packs of 3000 lm with different CCT.Luminaire should accommodate different color tiles & also accommodate Services like-AC Grill & Smoke detector etc.and a minimum system lumen output of 3000 lumens and maximum system wattage of 30W, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parametersEQUI. TO PHILIPS CAT NO. LMI1061 RC740B LED30S/840 W60L60,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. . LIGHTING LUMINARS Supply of Indirect optical design LED 600x600mm fitting made of CRCA powder quoted finish delivering soft and uniform light for visual comfort and a minimum system lumen output of 3000 lumens and maximum system wattage of 30W, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. EQUI. TO PHILIPS CAT NO. RC420B M LED 30S 6500 PSU WH ,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply of linear suspended /Recessed fitting made of extruded aluminium. Fixture should have minimum efficacy at System level (Not Chip Level) >100lumens/watt and a minimum system lumen output of 2600 lumens and maximum system wattage of 26W. Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance, CCT up to 4000/6500K, CRI >80, PF >0.95, THD<10% and an operating Voltage Range of 140 - 270 Internal Surge Protection 2.5KV. Fixture is available in both 4 ft and 8 ft module with 50 mm width options available.The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. EQUI. TO PHILIPS CAT NO.SP780 PLED26S-6500 PSU W5L113,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply of 6" LED Recessed Downlighter with a nominal system lumen output of 1500 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95 and 2.5KV surge protection. The luminaire housing should made of pressure die cast aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The total power consumption should not exceed 13.5W (including driver).The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 EQUI. TO PHILIPS CAT NO. DN296B LED15S PSU WH,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply of 5" LED Recessed Downlighter with a nominal system lumen output of 1000 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95 and 2.5KV surge protection. The luminaire housing should made of pressure die cast aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The total power consumption should not exceed 9W (including driver).The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007.EQUI. TO PHILIPS CAT NO. DN295B LED10S PSU WH,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply of 5" LED Recessed Downlighter with a nominal system lumen output of 600 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95 and 2.5KV surge protection. The luminaire housing should made of pressure die cast aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The total power consumption should not exceed 5.5W (including driver).The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007.EQUI. TO PHILIPS CAT NO. DN295B LED6S PSU WH,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply of 5" LED surface Downlighter with a nominal system lumen output of 600 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95 and 2.5KV surge protection. The luminaire housing should made of pressure die cast aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The total power consumption should not exceed 18W (including driver).The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007.EQUI. TO PHILIPS CAT NO.SM251C LED20S-6500 PSU WH,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply Installation testing and commissiong of LED 4ft Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 105 lm/W. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The luminaire housing should made of CRCA with a PC glossy diffuser. The total power consumption should not exceed 38W (including driver).EQUI. TO PHILIPS CAT NO. BN308C LED40S-6500 L12O PSU WH,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply Testing commissioning of Recessed Mounted 2'X2' LED Luminaire with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire. Luminaire should give more volumetric light & higher vertical illumination.Luminaire should be available in different Lumen Packs of 2000 lm with different CCT.Luminaire should accommodate different color tiles & also accommodate Services like-AC Grill & Smoke detector etc.and a minimum system lumen output of 3000 lumens and maximum system wattage of 20 W, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parametersMake ,India Bulls,Havells / Make Syska
LIGHTING LUMINARS Supply & installation testing commissioning ,loading ,transportation, unloading at site, storages at site of following type light fittings including required integral control gears, lamps, looping in/ looping out junction box & other accessories etc to complete the work as per Engineer -In -charge. LIGHTING LUMINARS Supply Installation testing and commissiong of LED 2 ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 105 lm/W. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The luminaire housing should made of CRCA with a PC glossy diffuser. The total power consumption should not exceed 20 W (including driver).Make Bulls,Havells / Make Syska / philips
Supply and installation of Clean room LED 600x600mm fitting made of CRCA powder coated finish delivering soft and uniform light for visual comfort and a minimum system lumen output of 3600 lumens and maximum system wattage of 32W, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=110lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. EQUI. TO PHILIPS CAT NO. CR652B LED60S-6500 PSU CA BO W60L60 WH ,India Bulls,Havells
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Supply, installation, testing and commissioning of ESE lightning arrester on top of building as per site requirement with copper / GI strip as required, as complete. ( Details specifications for ESE lightning arrester is attached Annaexure D )
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and painting etc. as required.
Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible,FR PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
Installation, testing and commissioning of pre-wired,fluorescent fitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
Floor mounted bucket stand with buckets to hand 4 nos. of 13 ltrs buckets. The stand shall be 5'(L) x 3'(H) x 2"(W) made out of 30 x 300 x4mm MS angle frame duly coated with 2 coats of red oxide primer & 2 coats of red finish paint
Antiskid black rubber mat of approved make,12 mm thick 900mm wide x 1800mm Long chequered type as per IS-5424 in following 1.1k.V. voltage grade(Jyothi Make)
First aid chart made of cloth for electricall shock treatment printed in English ,& Hindi duly framed with front glasses.
First Aid box with all the standard contents.
Portable 5 kg. dry type fire extinguisher suitable for electrical fire and as recommended by the tariff advisory committee.
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. : Hard rock (blasting prohibited)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil - Pipes, cables etc, not exceeding 80 mm dia.
UPS SYSTEM NECESSARY WORK UPS & Battery rack shifting from existing UPS room at third floor/secound floor to at work place installation, testing and commissioning of 100KVA rating UPS with ,15Min battery backup , with static & manual bypass Input Voltage: 3 Ph 415 Volts, ±10% Output : 3 -Phase-415Volts 4w 50 Hz ±1% , .( Note :- 100KVA UPS Dimesions 800X 800x2000mm Rack Size :- 1100x1000x2000mm UPS Make :- Numeric Archimode). Scope of work includes removing, shifting, transport, labour and reinstallation of UPS with its all accessories incluiding isolation transformer, power links, cables, switchgears with enclosuer etc as complete to make it functional. Installation should be done by Engineer of authorised service dealer or manufacture of said UPS. Related information should be submiited to IISER Pune in advance for approval. Any charges payable to the UPS agency will be borne by the contractor.
Supply, installation, testing and commissioning of Modular UPS 125 KVA having 125 / 150 KVA cabinet as per technical specifications mentioned in the Annexure I of special conditions of contract vide page no. 410 to 412 , including internal cabling and comprehensive warranty of one year complete as per terms & conditions ( External cabling not in scope of vendor). UPS make Numeric Novatuer / Vertive/ APC/ Eaton. (Rate shall be quoted as per detailed specifications attached vide Annexure I- Special conditions of contract page no. 410-412)
UPS SYSTEM NECESSARY WORK : Supply, Installation, Testing and Commissioning with min 200AH rating maintanance free type batteries complete with intercell connectors & copper cables, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries( for 15 Minutes battery rating min 200AH X 42 nos. Battery make Amaron Quanta/Exide/Rocket ), including 2 poles DC Battery brekers . Installation should be done by Engineer of authorised service dealer or manufacture of said UPS. Related information should be submiited to IISER Pune in advance for approval. Any charges payable to the UPS agency will be borne by the contractor. (Description of item continues on detailed specifications attached vide Annexure I- Special conditions of contract page no.412. Rate shall be quoted accordingly )
Isolation transformer: Supply, installation, testing and commissioning of 3 ph - 3 ph 400 V Isolation transformer with cabiner and protection switchgear etc as complete. Make : LEGRAND - NUMERIC / Vertiv / Eaton (Rate shall be quoted as per detailed specifications attached vide Annexure I- Special conditions of contract page no. 413)
DISMANTALING OF CABLES & SHIFTING OF LT PANELS : Dismantaling of Existing Cable of Following Sizes work is including dismetaling end termination of cables, glands & neceaasry fsupporting accessories. Cables are carrying from dismentaling place to storage place & coil it propoerly with out any damages & lable of tag shall be provided with measurement & rating of cablesDismantling the existing cables of all types & size up to 10 sq.mm.
DISMANTALING OF CABLES & SHIFTING OF LT PANELS Dismantaling of Existing Cable of Following Sizes work is including dismetaling end termination of cables, glands & neceaasry fsupporting accessories. Cables are carrying from dismentaling place to storage place & coil it propoerly with out any damages & lable of tag shall be provided with measurement & rating of cablesDismantling the existing cables of all types & size above 10 sq mm up to 50 sq. mm.
Dismantaling of Existing Cable of Following Sizes work is including dismetaling end termination of cables, glands & neceaasry fsupporting accessories. Cables are carrying from dismentaling place to storage place & coil it propoerly with out any damages & lable of tag shall be provided with measurement & rating of cablesDismantling the existing cables of all types & size above 50 sq.mm.
DISMANTALING OF CABLES & SHIFTING OF LT PANELS :Dismantaling & shifting of existing panel from First floor Electrical room to Proposed electrical room location at 4th/ 5 th floor in same building without any damages work is including installation testing & commissioning of panels following are sizes of panels Lift PDB PanelL- 2000mmX W-400mm X H- 2200mm
Dismantaling & shifting of existing panel from First floor Electrical room to Proposed electrical room location at 4th/ 5 th floor in same building without any damages work is including installation testing & commissioning of panels following are sizes of panelsLift Power PanelL- 600mmX W-150mm X H- 850mm
Dismantaling of Existing GI earthing strips upto 32 x 6 mm thick Sizes work is including dismetaling end termination of strip , insulator and supporting accessories. Strips are carrying from dismentaling place to storage place & coil it propoerly with out any damages & lable of tag shall be provided with measurement & rating of strips etc.
Dismentling of GI strips & point wiring with accessoreies of lightening arresters with its spike as required. Storage of material with invetary is in scope of agency.
Dismentling, shifting, reinstallation of solar water heater system with its whole assembly and accessories. During execution of work, required hardware, labour, tools and plant is in scope of agency. Reinstallation will be done at G+10 building on 10th floor ( terrace ).
Removing and storage of point wiring with required accessories and bulket fittings etc . dismentled material are carrying from dismentaling place to storage place & coil it propoerly with out any damages & lable of tag shall be provided with measurement & rating of material., etc.
Agumentation of lift : Lift Work Extension of existing gearless passenger (21 person) lift of Kone (G+3) make from 3rd floor to 5th floor. It include all below work with required accessories to complete job. 1.Providing and installing One no. landing door assembly with our New Landing Doors complete set. Door clear opening 1100 mm wide X 2100 mm high(SS Vandal proof finish). 2. Providing new COP (car operating panel) with newly extended floor designation. 3.Providing and installing new Landing Call Signalization(LCS+HLI) for newly added floor as per existing configuration. 4. Providing and installing compensation chain w.r.t. new travel, new Rope (OSG + Main), Guide rail with bracket (CAR + CWT) for extended floor, Complete fastener for extended floor component, Floor sensing magnet, Travelling cable & full set shaft wiring material. 5.Existing Car indicator & intercom is retained. 6.New no. of served floors after floor extension will be 05 floors(G+4). 7. Three phase and single phase electrical cables inside shaft only for new travel. 8.Distribution panel box outside last landing of lift including ELCB, MCB as per standard requirement. 9. Supply of elevator/elevator parts as per specification agreed 10.Installation ,testing commision of work, 11.Dismatling of old parts 12.Three phase and single phase cables inside shaft only and distribution panel box including ELCB, MCB outside last landing of the lift as per standard requirement. 10.24/7 IoT connected service for the period of one year per lift.
Agumentation of lift : Lift Work Extension of existing gearless service (2000kgs) lift of Kone (G+3) make from 3rd floor to 5 th floor. It include all below work with required accessories to complete job. 1.Providing and installing One no. landing door assembly with our New Landing Doors complete set. Door clear opening 1200 mm wide X 2100 mm high(MS Painted Finish). 2.Providing new COP (car operating panel) with newly extended floor designation 3.Providing and installing individual Landing Call Signalization (LCS+HLI) for newly added floor. 4.Providing and installing compensation chain w.r.t. new travel, new Rope (OSG + Main), Guide rail with bracket (CAR + CWT) for extended floor, Complete fastener for extended floor component, Floor sensing magnet,Travelling cable & full set shaft wiring material. 6.Existing Car indicator & intercom is retained. 7.New no. of served floors after floor extension will be 05 floors(G+4). 8.Three phase and single phase electrical cables inside shaft only for new travel. 9.Distribution panel box outside last landing of lift including ELCB, MCB as per standard requirement.10.24/7 IoT connected service for the period of one year per lift.
Hydrant system : Dismantalling, Shifting, Erection, testing & commissioning of Existing Pump, Existing Piping & fittings including valves as following points i) Existing Booster with pannel - 1 nos. ii) 80mm MS Pipe with fittings & valves - 320 m. iii) 50mm MS Pipe with fittings & valves - 10 m All work to be carried out complete up to the satisfaction of the Engineer in charge.
Hydrant system : Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required A) Piping Above Ground (Welded Joints)25 mm dia
Hydrant system : Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required A) Piping Above Ground (Welded Joints)80 mm dia
Hydrant system: Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required A) Piping Above Ground (Welded Joints)100 mm dia
Hydrant system: Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required A) Piping Above Ground (Welded Joints) 150 mm dia
Supply ,erecting and commissioning of landing Hydrants comprising of the following in the fire duct; Supplying and fixing single headed internal hydrantvalve with instantaneous Gunmetal/Stainless Steelcoupling of 63 mm dia with cast iron wheel ISI markedconforming to IS 5290 (Type -A) with blankGunmetal/Stainless Steel cap and chain as required :
Supply ,erecting and commissioning of landing Hydrants comprising of the following in the fire duct; Supplying and fixing 63 mm dia, 15 m long RRL hosepipe with 63 mm dia male and female couplings dulybound with GI wire, rivets etc. conforming to IS 636(type-A) as required : Stainless Steel (Grade 304)
Supply ,erecting and commissioning of landing Hydrants comprising of the following in the fire duct; Supplying & fixing 63 mm dia gun metal short branchpipe with 20 mm nominal internal diameter size nozzleconforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling asrequired :
Supply ,erecting and commissioning of landing Hydrants comprising of the following in the fire duct; Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following asrequired. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket.( 30 m )
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 25 mm dia
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 32 mm dia
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 40 mm dia
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 50 mm dia
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 65 mm dia
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 80 mm dia
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 100 mm dia
Automatic Sprinkler System Providing, laying, testing & commissioning of 'C' classheavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paintof required shade complete as required 150 mm dia
Providing, fixing, testing & commissioning of 15mm diaquartzoid bulb type sprinklers of rating 68 degreecentigrade with required accessories : Pendent Sprinkler
Providing, fixing, testing & commissioning of 15mm diaquartzoid bulb type sprinklers of rating 68 degreecentigrade with required accessories : Upright Sprinkler
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm nominal dia
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm nominal dia
Providing and fixing Inspection & Testing Assembly with gunmetal ball valve, gun metal sight glass bypass valve & connected to drain line etc complete as per drawing. complete all the work up to the satisfaction of the Engineer in charge. 25 mm nominal dia
Supplying, fixing, testing and commissioning of butterflyvalve of PN 1.6 rating with bronze/gunmetal seat duly ISImarked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 100 mm nominal dia
Supplying, fixing, testing and commissioning of butterflyvalve of PN 1.6 rating with bronze/gunmetal seat duly ISImarked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 150 mm nominal dia
Supplying and fixing orifice plate made out of 6 mmthick stainless steel (Grade 304) with orifice of requiredsize to be fitted between flange & landing valve ofexternal and internal hydrants to reduce pressure atthe outlet to the level of 3.5 kg/cm2 complete asrequired. 150 mm dia.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. Note: (a) For Cabling, earthing and cable trays please refer to DSR (E&M). (b) For digging of hard & soft soil please refer to DSR (Civil)
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread withmaximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPTmale thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete asrequired.(1000mm )
Supplying, installing, testing, and commissioning portable fire extinguishers of following type & capacity Supplying, installing, testing, and commissioning portable fire extinguishers of ABC dry powder stored pressure type fire extinguishers of 6 Kgs.capacity Complete with standard discharge valve with tube, CI bracket for wall mounting etc. complete as per confirming to IS : 15683 complete all the work up to the satisfaction of the Engineer in charge.
Supplying, installing, testing, and commissioning portable fire extinguishers of following type & capacity Mechanical Foam type fire extinguishers of 9Kgs.capacity Complete with standard discharge valve with tube, CI bracket for wall mounting etc. (confirming to IS : 15683)
Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. It should be compatible with existing system.
Supply & laying of FRLS type armoured cable of 2 Core x 1.5 sq.mm, Copper (Cu) conductor, Shielded Twisted pair, XLPE insulated wire, confirming to IS standards and as per technical specfications with all the necessary accessories as required to complete laying/installation laying/installation for Fire alarm System. outer sheath of fire alarm cable shall be Red
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector for below false ceiling & True ceiling(above false ceiling) complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.specifications data sheet.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supply, Installation, Testing & Commissioning of Addressable Relay module as per technical specifications with all the necessary mounting accessories as required for complete installation.
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
SECTION 2- PUBLIC ADDRESS SYSTEM Supply, Installation, Testing & Commissioning of Main Unit / Network Controller for Public Address System consisting of Central Digital Signal Processor module, 2 x 16-character LCD Display, 8 Supervised Control Inputs and 4 Audio Inputs, Ethernet Interface for Configuration and Diagnostics & Logging functions, Digital message storage capable of storing at least up to last 200 faults messages, RS232 Interface for logging, OFC Network Inteface capability, PC Interface, EPABX interface and an interface for Fire Alarm signal.It will support essential capabilities such as - pre-programmed emergency messages, background music & configurable multiple zones as per BS5839 and EN60849 standards as per tender specifications. It shall support Multi level of priority, support several type chime/tones/ emergency tones.Important availability features will include loudspeaker line monitoring and loudspeaker monitoring without requiring any additional cabling for every loudspeaker installed. It should be support & included with web based server software Application for System Configuration, Management & Diagnostics.It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.
Supplying, installation, testing & commissioning of 6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 6W metal box ceiling/wall speakers complete as required.
Supply & laying of FRLS type Flexible Unarmoured cable of 2 Core x 1.5 sq.mm, Copper (Cu) conductor, Shielded Twisted pair, XLPE insulated wire, confirming to IS standards and as per technical specfications with all the necessary accessories as required to complete laying/installation for Public Address System, Communication cables for Soft Link whereever applicable
Supply, Installation, Testing & Commissioning of UTP CAT6 Angular patch panel pre-loaded with 24 ports in 1U form factor, with universal A/B labeling and 110 connector terminations on rear of panel allowing for quick and easy installation of 22 to 24 AWG cable, inclusive of termination of UTP CAT6 cables at all 24 ports. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.
Supply, Installation, Testing & Commissioning of UTP CAT6 Angular patch panel pre-loaded with 48 ports in 2U form factor, with universal A/B labeling and 110 connector terminations on rear of panel allowing for quick and easy installation of 22 to 24 AWG cable, inclusive of termination of UTP CAT6 cables at all 48 ports. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.
Supply, Installation, Testing & Commissioning of single UTP CAT6 I/O of specified make with different colours for differentiating Data, Voice & Wifi and other services inclusive of termination of UTP CAT6 cable at each I/O as required as per drawing. The IO shall be mounted inside singlex or duplex or quad faceplate as applicable and using suitable backbox assembly. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.
Supply, Installation, Testing & Commissioning of faceplate with blank Inserts and corresponding MS backbox assembly for installation of: MS backbox assembly shall be provided for outlets installed at wall or at furniture, wooden or any partition at workstation area/device for flush mounting. For exposed mounting, PVC backbox assembly shall be provided. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation. Single I/O faceplate
Supply, Installation, Testing & Commissioning of UTP CAT6 RJ-45 Patch Cords Solid Conductor of various lengths with different colours for differentiating Data, Voice & Wifi and other services. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.1 meter
Supply, Installation, Testing & Commissioning of UTP CAT6 RJ-45 Patch Cords Solid Conductor of various lengths with different colours for differentiating Data, Voice & Wifi and other services. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.2 meters
FIBER OPTIC CABLE & COMPONENTS Supply, Installation, Testing & Commissioning and Laying of fiber optic cable of various capacities to be laid in prelaid conduits/RCC hume pipes/HDPE/DWC/cable trays as applicable. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.6 cores OS2 Singlemode armoured fiber cable, uni-tube, high density polyethylene outer jacket
Supply, Installation, Testing & Commissioning of Wall mounted LIU of various capacities for optical splicing/termination of fiber optic cable as per the design schematics. It shall be complete with adaptor panels, adaptors and splice trays for using LC type termination and asking/blanking/dustcover for unused/unmounted adaptor ports, inclusive of all mechanical accessories. Adequate splice trays shall be provided for proper management of splices for required number of cores at every LIU. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.for 12 cores, Singlemode LC termination
Supply, Installation, Testing & Commissioning of Wall mounted LIU of various capacities for optical splicing/termination of fiber optic cable as per the design schematics. It shall be complete with adaptor panels, adaptors and splice trays for using LC type termination and asking/blanking/dustcover for unused/unmounted adaptor ports, inclusive of all mechanical accessories. Adequate splice trays shall be provided for proper management of splices for required number of cores at every LIU. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.For 6 cores, Singlemode LC termination
Supply, Installation, Testing & Commissioning of rack mounting type fiber shelf of various capacities for assembly/termination of fiber optic cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable. Any blank adaptor positions must be suitably masked for restricting dust entry. Adequate splice trays shall be provided for proper management of splices for required number of cores at every LIU. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.for 12 cores, Singlemode LC termination
Supply, Installation, Testing & Commissioning of rack mounting type fiber shelf of various capacities for assembly/termination of fiber optic cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable. Any blank adaptor positions must be suitably masked for restricting dust entry. Adequate splice trays shall be provided for proper management of splices for required number of cores at every LIU. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.For 6 cores, Singlemode LC termination
Supply, Installation, Testing & Commissioning of SC-LC duplex fiber optic patch cords of various lengths. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation. 1 meter, single mode
Supply, Installation, Testing & Commissioning of SC-LC duplex fiber optic patch cords of various lengths. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation. 2 meters, single mode
Supply, Installation, Testing & Commissioning of SC type duplex pre-terminated fiber optic cable pigtails of various lengths. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation. 1 meter, single mode
Supply, Installation, Testing & Commissioning of SC type duplex pre-terminated fiber optic cable pigtails of various lengths. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation. 2 meters, single mode
Supply, Installation, Testing & Commissioning of SC type couplers for high density termination, singlemode. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation.
Splicing / Termination of Fiber Optic Cable Cores using Fusion splicing with pre-terminated LC pigtails, dressing and proper fixing in splice trays. Including Splicing Kit.
NETWORKING ENCLOSURES Supply, Installation, Testing & Commissioning of 19" wide mounting frame Networking Enclosures of various sizes and capacities complete with cable manager & all accessories. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation. 22U, 800mmW x 800mmD, floor mounted, 4 x 90cfm fans
NETWORKING ENCLOSURES Supply, Installation, Testing & Commissioning of 19" wide mounting frame Networking Enclosures of various sizes and capacities complete with cable manager & all accessories. It shall be as per technical specifications with all the necessary mounting accessories as required for complete installation. 42U, 1000mmW x 1000mmD, floor mounted, 4 x 90cfm fans
Supply Installation Testing & commissioning of IP 2MP IR DOME CAMERA , with fixed Lens, 1/3" Progressive Scan CMOS, ICR, 0 lux with IR, 1920x1080: 25/30fps, 2.8 mm lens, H.264/MJPEG, dual -Stream, BLC, UP to 30m IR, Vandal-proof, DC12V/PoE , Full HD, DWDR, 3D DNR, Smart IR, 30m IR, Support Intrusion detection, line crossing. ONVIF, UL LISTED. CERTIFICATE CE & FCC.
Supply Instalaltion, Testing & commissioning of Basic L2 features 24 Port PoE auto-sensing 10/100/1000 Network Switch with 2 SFP Port, 2 X 1G Uplink Ports including standard connectivity accessories. (for CCTV Camera)
Supply Instalaltion Testing and commissioning of CAT 6 , UNARMOURED STP CABLE equvillant to to D-Link,AMP/digilink/ Cisco
SITC of IP, 16CH NVR, 2 SATA HDD Slot (Max 8TB), with 4 TB hard disk of approved make, 12VDC,Realtime Recording Resolution (16 Channels @ 720P,8 Channels @1080P),Real-time Local Playback( 4 Channels @720P,2 Channels @1080P),Multiplex Operation,H.264 High profile,BNC/VGA/HDMI output, main profile, baseline,HDD Redundancy,Free DDNS,Network backup, USB HDD, USB writer, SATA writer,1 RS485, support 18 kinds of PTZ protocols,ONVIF 2.0,1 channel Audio Input and Output, Make-Honeywell CALNVR-2016B or equivalent approved make.
Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification.Access Controllers, each with capacity of 10000 events buffer memory connecting the item listed below such as card readers, , Magnetic locks, boom barriers etc 1 door ‐ 2 reader controller with enclosure
Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification.Access Controllers, each with capacity of 10000 events buffer memory connecting the item listed below such as card readers, , Magnetic locks, boom barriers etcSmart Card readers with stainless steel base plate
Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification.Access Controllers, each with capacity of 10000 events buffer memory connecting the item listed below such as card readers, , Magnetic locks, boom barriers etc Release push button (Green Colour)
Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification.Access Controllers, each with capacity of 10000 events buffer memory connecting the item listed below such as card readers, , Magnetic locks, boom barriers etc Electromagnetic Locks 600 LBS ‐ Single Door
Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification.Access Controllers, each with capacity of 10000 events buffer memory connecting the item listed below such as card readers, , Magnetic locks, boom barriers etc Door Positioning Sensor
Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification.Access Controllers, each with capacity of 10000 events buffer memory connecting the item listed below such as card readers, , Magnetic locks, boom barriers etc Emergency break Glass(Green Colour)
Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification.Access Controllers, each with capacity of 10000 events buffer memory connecting the item listed below such as card readers, , Magnetic locks, boom barriers etc 12 V, 3 amp DC Power Supply
FRLS sheilded Cables: Supply and Laying of 1 sqmm x 4 core multistand armoured shielded Cable from electromagnetic lock/Sensor to Controller.
FRLS sheilded Cables: Supply and Laying of 1sqmm x 6 core multistand armoured shileded Cable from Reader to Controller.
FRLS sheilded Cables: Supply and Laying of Cat-6 unarmoured cable for controller to controller & Cabin push button.
FRLS sheilded Cables: Supply of Smart Card
FRLS sheilded Cables: Supply and Laying of .75sqmm x 2 core multistand armoured shileded Cable for push button
AV connection : Supply and laying of HDMI cable on surface / recess / on open tray with casing n caping / in wooden furniture with required accessories, as complete.
Supply and fixing of HDMI end termination with required connector, cripping etc as complete.
Supply , installation , testing and commissioning of HDMI spitter 1 in + 6 out with required power supply , connector and accessories as complete. Make D link / Atos
Supply of Precision Package Air conditioning system Floor Mounted, Top discharge Air Cooled DX type Precision Air conditioners of 4TR actual cooling capacity unit on individual circuit. Gross Total cooling Capacity at return air temperature of 22degC+/- 0.5 deg C DB & 50%+/- 5% RH and Outdoor Ambient Condition of 40Deg C with R-410a Refrigerant Gas only. The Indoor unit shall comprise of Variable speed and variable capacity Inverter Scroll Compressor R-410a refrigerant, DX type with totally Double skin sandwitched panels on all four side with 20 mm 32 Kg/ cum Glass wool internal insulation, Indoor and outdoor unit body material : GI powder coated with minimum 18 SWG, Evaporator Fan complete with Backward curved type with EC motor, Evaporator DX Cooling Coil with hydrophilic coating, Microprocessor controllers, Electronic Expansion valves (EEV), Filter Driers, G4 Filter, Suction and Discharge piping, Internal power and Control wiring, Crankcase heaters, Humidifiers, Heaters, HP/LP Cut-outs, Power and Control contactors, filters, Pressure relief valve, Oil Seperator, water leak detector for unit and Other Electrical accessories. The evaporator coil should be with hydrophilic coating & stainless steel drain tray. The machine shoule be inbuilt with hot gas reheat coil arrangement with modulating control for better control & precise operation. The Air-cooled Outdoor Condenser unit shall comprise of Condenser fans & motor, Condenser cooling coil (Copper coil with aluminium fins), Isolator switch. The Air cooled condenser shall be with fan speed regulator with stepless speed variation. The unit shall be suitable for operation on 375 to 455 Volts, 50 Hz, 3 Phase, 4 Wire AC supply. Each unit should be having individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults, limiting values and PAC wellness alarm / service alarm to reduce the down time and unit memory shall hold minimum 200 most recent events with ID number, time and date stamp for each event. Machine should be inbuilt with modbus type BMS card for remote monitoring. Total cooling capacity at return air condiions: 22 Deg. C, RH 55% and with outdoor air temp. of 40Deg.C shall be 4 TR. Machine discharge- Top. Heaters - 4.5 kW. Interconnected refrigerant piping upto 30 mtr. Interconnected control cabling. Outdoor unit MS stand with painting. First charge of R-410a Refrigerant
Chilled water cassette / hiwall / Fan coil units:- 1.0 TR Capacity - Cassette units with drain pump Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Chilled water cassette / hiwall / Fan coil units:- 1.5 TR Capacity - Cassette units with drain pump Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Chilled water cassette / hiwall / Fan coil units:- 2.0 TR Capacity - Cassette units with drain pump Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Chilled water cassette / hiwall / Fan coil units:- 2.0 TR Capacity Fan coil unit Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Chilled water cassette / hiwall / Fan coil units:- 2.5 TR Capacity Fan coil unit Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Chilled water cassette / hiwall / Fan coil units:- 3.0 TR Capacity Fan coil unit Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Chilled water cassette / hiwall / Fan coil units:- 3.5 TR Capacity Fan coil unit Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Chilled water cassette / hiwall / Fan coil units:- 2.0 TR Hi wall unit Supplying, installing, testing and commissioning of factory built horizontal FAN COIL UNITS, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube and aluminium fins construction with hydrophilic coating, one or more centrifugal fans with 3 speed motor, cleanable synthetic fibre filters, casing, coil piping connections, through copper pipes, condensate drain connections with U trap, factory fitted valve package with PIBCV valve station along with thermostat and sensors, wiring, control wiring in conduit upto thermostat boxes. Necessary copper coil piping connections shall be provided. FCU shall be provided with 1.25mm thick stainless steel extended drain pan with 13mm thick aluminium foil faced insulation to ensure the covering of all copper connections and valves. All fan coil units shall be suitable for 230 ± 6% volts, 50 cycles, single phase power supply.Noise level shall be 45 dB (A) at 1 m distance.Fan coil units shall be of following capacities as listed. As per technical specifications with all the necessary mounting accessories including rubber groomets for vibration isolation as required for complete installation.
Supplying & fixing of copper refrigerant piping of 2.0 Tr capacity hiwall with minimum 9 mm insulation complete from indoor unit to outdoor unit with supports Etc. of suitable size.
CHILLED WATER PIPING:- 125 mm dia. x 32 mm thk insulation Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
CHILLED WATER PIPING :- 100 mm dia. x 32 mm thk Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
CHILLED WATER PIPING:- 80 mm dia. x 32 mm thk Insulation Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
CHILLED WATER PIPING:- 65 mm dia.x 32 mm thk Insulation Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
CHILLED WATER PIPING:- 50 mm dia.x 32 mm thk Insulation Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
CHILLED WATER PIPING:- 40 mm dia.x 32 mm thk Insulation Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
CHILLED WATER PIPING :-32 mm dia.x 19 mm thk Insulation Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
CHILLED WATER PIPING: - 25 mm dia.x 19 mm thk Insulation Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
UPVC drain pipes:- 40 mm dia. Supply, Installing, testing and commissioning of UPVC pipe for condensate complete with 6mm thick nitrile rubber insulation drain for AHUs/ FCU, cut to required length with necessary, clamps, supports, hangers, fittings such as bends, tees, reducers etc to nearest drain point complete as per technical specifications with all the necessary mounting accessories as required for complete installation.
UPVC drain pipes:- 32 mm dia. Supply, Installing, testing and commissioning of UPVC pipe for condensate complete with 6mm thick nitrile rubber insulation drain for AHUs/ FCU, cut to required length with necessary, clamps, supports, hangers, fittings such as bends, tees, reducers etc to nearest drain point complete as per technical specifications with all the necessary mounting accessories as required for complete installation.
UPVC drain pipes:- 25 mm dia. Supply, Installing, testing and commissioning of UPVC pipe for condensate complete with 6mm thick nitrile rubber insulation drain for AHUs/ FCU, cut to required length with necessary, clamps, supports, hangers, fittings such as bends, tees, reducers etc to nearest drain point complete as per technical specifications with all the necessary mounting accessories as required for complete installation.
65 mm dia Y strainer - Indoor insulation Supply, testing, and fixing in position the following ‘Y’ Strainers : Strainers shall be fabricated out of MS ‘C’ class pipe two sizes higher than that of Strainer pipe size. Filter element shall be of non-magnetic 20 gage SS sheet with 3 mm perforation. Cartridge having five different type of filters made out of SS 304 with different mesh sizes shall be provided. Magnetic plug to be provided to attract iron particles
40 mm dia Y strainer - Indoor insulation Supply, testing, and fixing in position the following ‘Y’ Strainers : Strainers shall be fabricated out of MS ‘C’ class pipe two sizes higher than that of Strainer pipe size. Filter element shall be of non-magnetic 20 gage SS sheet with 3 mm perforation. Cartridge having five different type of filters made out of SS 304 with different mesh sizes shall be provided. Magnetic plug to be provided to attract iron particles
32 mm dia Y strainer - Indoor insulation Supply, testing, and fixing in position the following ‘Y’ Strainers : Strainers shall be fabricated out of MS ‘C’ class pipe two sizes higher than that of Strainer pipe size. Filter element shall be of non-magnetic 20 gage SS sheet with 3 mm perforation. Cartridge having five different type of filters made out of SS 304 with different mesh sizes shall be provided. Magnetic plug to be provided to attract iron particles
Ball valves :- 40 mm dia Supply, Installing, testing and commissioning of with PN-10 pressure rating ball valve, bronze forged body, chrome plated bronze ball and control level etc. in position complete as per technical specifications with all the necessary mounting accessories as required for complete installation. Insulation shall be similar to pipe size to be considered.
Ball valves :- 32 mm dia. Supply, Installing, testing and commissioning of with PN-10 pressure rating ball valve, bronze forged body, chrome plated bronze ball and control level etc. in position complete as per technical specifications with all the necessary mounting accessories as required for complete installation. Insulation shall be similar to pipe size to be considered.
Ball valves :- 25 mm dia Supply, Installing, testing and commissioning of with PN-10 pressure rating ball valve, bronze forged body, chrome plated bronze ball and control level etc. in position complete as per technical specifications with all the necessary mounting accessories as required for complete installation. Insulation shall be similar to pipe size to be considered.
Instruments :- Supply, Installing, testing and commissioning of Temperature gauge 0-50 deg C / 6 " dial
Instruments :- Supply, Installing, testing and commissioning of Pressure gauge 0-7 kg/sqcm / 6" dial
Instruments :- Supply, Installing, testing and commissioning of 25mm automatic air vents with valves
Exhaust Inline Fans :- 1000 CFM / 15 MMSP Supply, installing, testing and commissioning of following capacities of ducted inline centrifugal fan as per specification and complete with suitable 1 phase Motor with 3 speed control,bird screen. etc. and complete as per technical specifications with all the necessary mounting accessories as required for wall or ceiling mounting for complete installation.
Exhaust Inline Fans :- 400 CFM / 15 MMSP Supply, installing, testing and commissioning of following capacities of ducted inline centrifugal fan as per specification and complete with suitable 1 phase Motor with 3 speed control,bird screen. etc. and complete as per technical specifications with all the necessary mounting accessories as required for wall or ceiling mounting for complete installation.
Exhaust Fans :- Propeller fan with back draft shutter - 200 cfm Supply, installing, testing and commissioning of following capacities of ducted inline centrifugal fan as per specification and complete with suitable 1 phase Motor with 3 speed control,bird screen. etc. and complete as per technical specifications with all the necessary mounting accessories as required for wall or ceiling mounting for complete installation.
SHEET METAL WORKS :- 0-750 -------0.63 MM (24G) with flanges Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
SHEET METAL WORKS :- 751-1500------0.80 MM (22G) with MS flanges Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
SHEET METAL WORKS ;- 1501-2250------1.00 MM (20G) with MS Flanges Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.... Fire damper
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.... Actuator
VAV Boxes (Variable Air Volume) :- 500-1000 cfm Supply installation testing and commissioning of Pressure independent type variable air volume control units as specified & complete with 1000mm long flexible connection on both the sides, actuator & Thermostat.
VAV Boxes (Variable Air Volume) :- 1500-2000 cfm Supply installation testing and commissioning of Pressure independent type variable air volume control units as specified & complete with 1000mm long flexible connection on both the sides, actuator & Thermostat.
VAV Boxes (Variable Air Volume) :- 2000-2500 cfm Supply installation testing and commissioning of Pressure independent type variable air volume control units as specified & complete with 1000mm long flexible connection on both the sides, actuator & Thermostat.
VAV Boxes (Variable Air Volume) :- 4800 cfm Supply installation testing and commissioning of Pressure independent type variable air volume control units as specified & complete with 1000mm long flexible connection on both the sides, actuator & Thermostat.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supply, installation, testing & commissioning of 25 mm thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications... Size 250 mm dia
Supply and installation of aluminium powder coated louvres with filter 10 micron
Duct thermal insulation :- 16 mm thick Supply, Installing, testing and commissioning of duct thermal insulation, elastomeric nitrile rubber with aluminium foil faced, class 'O' on ducts complete as per technical specifications with all the necessary mounting accessories as required for complete installation. The thermal conductivity of insulation shall not be more than 0.035 W/m°k @ 0°C mean temperature and density of insulation shall be 40-60 Kg/Cum.
Duct thermal insulation :- 19 mm thick Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Supplying and fixing of acoustic lining on wall and ceiling of AHU rooms with 50 mm thick, density 32 kg/cu.m resin bonded rock wool insulation with less than 10% split particles and shall be fixed in 610 mm x 610 mm frame work made of 25x50x50x50x25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc.complete as required and as per specifications with all the necessary mounting accessories as required for complete installation.
Supplying, installing & testing of acoustic lining Class '1' open cell nitrile rubber within supply and return air ducts as per the specifications. All ducts shown cross hatched on the approved shop drawings shall be provided with acoustic lining of open cell nitrile rubber insulation with density 140-180 Kg/ cum as per technical specifications with all the necessary mounting accessories as required for complete installation. The thermal conductivity of insulation shall not be more than 0.045 W/m°k @ 0°C mean temperature. THe material shall have anti microbial property
BUILDING MANAGEMENT SYSTEM Supply, Installation, Testing & commissioning of the following BMS system for HVAC system operation and hook up with exsiting BMS system. Graphical interface software based on MS Windows 2000/XP Platform The software shall be open system architecture type which facilitates interoperability with other system. Complete functions as described in specs shall be included. ( Additional license for taking present requirement in EXISTING HONEYWELL BMS )
BUILDING MANAGEMENT SYSTEM Supply, Installation, Testing & commissioning of the following BMS system for HVAC system operation and hook up with exsiting BMS system. Network Control Unit/Router with 32/16 bit processor & inbuilt memory for data backup incase of power failure for interface between DDC Controller / PLC and Man Machine Interface. Soft integration of 4 Nos AHU through BACNET / Modbus of controller of AHU with interface adaptar for AHUs and 4 nos PAC
BUILDING MANAGEMENT SYSTEM :- DDC Controller - Cooling tower and pumps, chiller to interface with CPM Supply installation testing and commissioning of Individual Automation stations / DDC Controller with I/O module etc., as per IO summary for corresponding AHU as per air flow diagram other equipments considering 10% spare counts with necessary enclosure. The controllers shall be 32 bit microprocessor based standalone and networkable type with real time clock, with inbuilt port for POT (Portable Operating Terminal), Peer-Peer communication and battery backup in an enclosure with necessary accessories, transformers, SMPS, wiring and relays etc., complete in all respect as per IO schedule of following systems. Light arrangement shall be provided inside each DDC panel: Enclosure already available only components need change. Necessary software license charge to be included. Soft integration of 4 Nos AHU through BACNET / Modbus of controller of AHU with interface adaptar for AHUs and 4 nos PAC
2 core 1.5 sq. mm twisted, shielded, Multistranded copper cable (Sensor Signal/Communication Bus). Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
CAT 6 cable Supply, installation, testing and commissioning of Armoured following cables with terminations as per specifications.
Providing Fire stop mortar system for sealing of shaft after pipe/duct are passed , with minimum 2 hours fire rating when tested in accordance with UL 1479 (American) standards, for horizontal openings in floors or slabs after passing service lines like Metal/Plastic Pipes, HVAC Duct with combustibel/Non Combustible insulations. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be UL listed & classified and shall bear the UL approval logo on the packing. Firestop installation should be done by Hilti Accredated Firestop Speciality Contractor (HAFSC) and in accordance with Hilti guidelines.
Providing Acrylic Firestop Sealant in gaps between dry wall and slab made of concrete to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be UL listed & classified and shall bear the UL approval logo on the packing.
Destratification fans :- 1100 CFM Fan - Suitable upto coverage radius 9 m from height of 5m. Supply installation testing and commissioning of De stratification Axial turbine fans with multivane to be installed in areas with all accessories , cabling and earthing limited to 10 RMT max per fan, Fan should be single body, lightweight, Noise level should not be more than 30dBA. Fan should be with arrangement to adjust the air flow direction verticlly in 90 Deg & horizontally 360 Deg.
UVGI system :- 1400 CFM Supply, installation, commissioning, and testing of UVGI system for disinfecting airstream. UVGI system shall be designed for effective disinfection and provide a UV dose of greater than 4,000 microwatt/cm2sec in a single pass. The system must include UV modules with dish antenna shaped parabolic reflectors to ensure that no stray UV-C radiation is leaked. The UVGI Equipment shall be listed to UL The unit to be supplied with its control panel and also provide interlocking of operation of UVGI lamp when AHU / Indoor unit operates. The capacity suitable for following air handling capacity in CFM.
UVGI system :- 1000 CFM Supply, installation, commissioning, and testing of UVGI system for disinfecting airstream. UVGI system shall be designed for effective disinfection and provide a UV dose of greater than 4,000 microwatt/cm2sec in a single pass. The system must include UV modules with dish antenna shaped parabolic reflectors to ensure that no stray UV-C radiation is leaked. The UVGI Equipment shall be listed to UL The unit to be supplied with its control panel and also provide interlocking of operation of UVGI lamp when AHU / Indoor unit operates. The capacity suitable for following air handling capacity in CFM.
4C x 16 Sq.mm. ( XLPE Copper Armoured Cables ) Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.
4C x 10 Sq.mm. ( XLPE Copper Armoured Cables ) Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.
4C x 6 Sq.mm. ( XLPE Copper Armoured Cables ) Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.
3C x 10 Sq.mm. ( XLPE Copper Armoured Cables ) Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.
3C x 4 Sq.mm. ( XLPE Copper Armoured Cables ) Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.
2C X 1.5 sqmm copper armoured control cable Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.
3C X 1.5 sqmm copper armoured stranded control cable Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.
EARTHING :- 6 sqmm copper wire Providing & fixing in position the following PVC Insulated Green Outersheath copper wire including providing all fixing accessories & effecting proper connections bu using tin plated copper lugs.
EARTHING :- 25 x 3 mm GI earthing strip Providing & fixing in position the following PVC Insulated Green Outersheath copper wire including providing all fixing accessories & effecting proper connections bu using tin plated copper lugs.
CABLE TRAYS :- 300 mm wide x 25 mm x 1.6 mm thk Supply and fixing pregalvanized factory fabricated GI perforated type cable tray with radial bends, supports of following sizes as per specifications
CABLE TRAYS :- 200 mm wide x 75 mm x 1.6 mm thk Supply and fixing pregalvanized factory fabricated GI perforated type cable tray with radial bends, supports of following sizes as per specifications
CABLE TRAYS :- 150 mm wide x 75 mm x 1.6 mm thk Supply and fixing pregalvanized factory fabricated GI perforated type cable tray with radial bends, supports of following sizes as per specifications
PP-FRP DUCTING & ACCESSORIES : - Ducting upto 500mm Dia - wall thickness shall be 3 mm PP and 3 mm FRP. Supply and installation of PP-FRP ducting with glass lined (GL) finish, FRP lining shall be of fire resistant Bisphenol resin. Duct pricing is inclusive of all necessary flanges, bends, entry branches, tapers, inspection door, gaskets for flanges, bolt & nuts, washers, support angle, hanger threaded rods with anchor bolts for fixing. Rate is inclusive of enamel painting for exposed surfaces. Mode of measurement shall be in sqm, measured as circumference x running length, extra will not be paid for accessories such as flanges, bends, elbows, Y piece, branch off, reducers, tapers, entry doors, inspection doors, gaskets etc.
Supply & fixing of Transparent PP 315mm dia. single leaf damper with both side flanges suitable for manual operation for Fumehoods. Supply and installation of PP-FRP ducting with glass lined (GL) finish, FRP lining shall be of fire resistant Bisphenol resin. Duct pricing is inclusive of all necessary flanges, bends, entry branches, tapers, inspection door, gaskets for flanges, bolt & nuts, washers, support angle, hanger threaded rods with anchor bolts for fixing. Rate is inclusive of enamel painting for exposed surfaces. Mode of measurement shall be in sqm, measured as circumference x running length, extra will not be paid for accessories such as flanges, bends, elbows, Y piece, branch off, reducers, tapers, entry doors, inspection doors, gaskets etc.
Supply & fixing of 325mm Dia flexible hose with 350 mm Dia. Clips for FumeHood (~ length 800mm L Each) Supply and installation of PP-FRP ducting with glass lined (GL) finish, FRP lining shall be of fire resistant Bisphenol resin. Duct pricing is inclusive of all necessary flanges, bends, entry branches, tapers, inspection door, gaskets for flanges, bolt & nuts, washers, support angle, hanger threaded rods with anchor bolts for fixing. Rate is inclusive of enamel painting for exposed surfaces. Mode of measurement shall be in sqm, measured as circumference x running length, extra will not be paid for accessories such as flanges, bends, elbows, Y piece, branch off, reducers, tapers, entry doors, inspection doors, gaskets etc.
Re installation of dismantled Blower (Capacity upto 7.5Kw) with blower mounting frame, supports & Etc.
Harsh Constructions Private Limited
Surendra Infrastructure Pvt. Ltd.
SOM PROJECTS PRIVATE LIMITED
KALPANA STRUCT CON PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid