| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.9 L+₹78,755 (2.53%)Rejected-Finance | L2 | Rejected-Finance Not Being lowest | |
| 3 | L3₹33.0 L+₹1.9 L (5.95%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance Not Being lowest | |
| 4 | L4₹35.0 L+₹3.9 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Not Being lowest | |
| 5 | L5₹35.2 L+₹4.1 L (13.3%)Rejected-Finance 30 B 1 DEEN DAYAL NAGAR NAWABGANJ DEEN DAYAL NAGAR KANPUR NAGAR UTTAR PRADESH 208002 | KANPUR NAGAR | UTTAR PRADESH | 208002 | L5 | Rejected-Finance Not Being lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
27 Aug 2022, 6:00 pmClosed
GE
GE 860 EWS
REAIR TO DOOR, WINDOW,WALL PANELLING, FALSE CEILING , GLASS PANES, CGI SHEET, WOODEN FLORING, TILING, PLASTERING AND MISC WORK AND REPAIR/MAINT TO LT PANEL BORD , FEEDER PILLAR BOX, JUNCTION BOX AND CONNECTED WORK SERVICE AT KARU ZONE II UNDER GE 860
2022_MES_540392_1
8159/2022-23/E8
Open Tender
Civil Works
Item Rate
270 days
Karu
Class D category a(i) b(i)
9 documents required · 9 mandatory
₹500
GE 860 EWS
₹98,000
Yes
6 Oct 2022
23 Jul 2022
29 Aug 2022
23 Jul 2022
27 Aug 2022
6 Aug 2022
Amount
Dismantling of boarding in wall/ceiling, any description, fixed in any position with nails or screws complete all as specified and directed by Engr-in-Charge. (Note: Taking down carefully old FTL fitting recessed mounted light fittings/ceiling complete with all accessories and making necessary electric connection, complete all as spd & directed by Engr-in charge.
M&L for 4mm thick 3 Nos of ply veneered decorative plywood grade1 (with BWR, resin) with one side of decorative veneered face fixed with screw to timber frame work in ceiling/wall complete all as specified.
M&L for 9mm thick pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws/nails to timber frame work in wall portion all as specified and directed by Engr-in-Charge.
S&F grid false ceiling GI system powder coated prelude (main runner section 32x24x0.30x3600mm, cross tee 25x24x0.30x1200mm, wall angle 24x24x0.40x3000mm and including providing and fixing PVC pre-laminated in frontside and aluminium foil backed gypsum tile board of size 595 x 595 x 8-9mm fixed in ceiling frame work with necessary fastening GI wire and cleats complete all as specified and directed.
M&L for french polishing on surface of any description width or girth including cleaning and prepairing the surface including a coat of wood filler on new works with two or more coats complete all as specified.
Dismantling of timber scantling in fillets, posts, rafters, purlins etc under 40Sq. Cm in section complete in framed work complete all as specified.
M&L for 2nd class hard wood timber scantling plain fillets square, rectangular in section area exc 13 Sqcm and not exc 25sqcm secured with nails complete all as specified.
M&L for 2nd class soft wood fillets sectional area exc 3 and n exc 6 sqcm rectangular or triangular in section but bullnosed, splayed, chamfered or rounded on one edge of face, secured with nails or brads, complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
Taking down of chowkhats with shutter (without taking of shutter from frame) n. exc 1.5 Sqm each complete all as specified and directed by Engr-in-Charge.
Taking down of chowkhats with shutter (without taking of shutter from frame) exc 1.5 Sqm but n. exc 4.0 Sqm each complete all as specified and directed by Engr-in-Charge.
Resecuring or easing & adjusting of door shutter of any description without taking down exc 1 Sqm but not exc 2 Sqm complete all as specified and directed by Engr-in-Charge.
S&F of 2nd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engr-in-Charge.
S&F of 30mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, fitted to chowkats complete all as specified and directed by Engr-in-Charge.
S&F for 30mm thick 2nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) complete all as specified..
S&F of 100mm size, butt hinges, cold rolled mild steel with screw, medium weight , ISI marked complete all as specified.
S&F of 75mm size, butt hinges, cold rolled mild steel with screw, medium weight , ISI marked complete all as specified.
S&F in repair of 125mm long Aluminium, anodised, barrel tower bolt, of extruded section with screws complete all as specified.
S&F in repair of 125mm size, extruded aluminium alloy handles fabricated type anodised complete all as specified and directed by Engr-in-Charge.
S&F of 250mm long stainless steel, sliding door bolts, plate type,with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engr-in-Charge.
S&F aluminium anodised door shutter aiuminium section weighting 0.55 kg/m including nessary joint cleats, glazing clips, ruber neoprene packing, handles aluminium snap beading screw etc. complete all as specified
S&F aluminium anodised window and ventilator shutter, side hung type without sash bars aiuminium section weighting 0.55 kg/m including nessary joint cleats, glazing clips, rubber neoprene packing, aluminium snap beading screw anodised alumimium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (02 Nos), suitable handle (01 No), complete all as specified and directed by Engr-in-Charge.
S&F aluminium anodised frame for door, window and ventilator with one or more rebates including joining cleat for fixing etc. complete all as specified.
M&L for 5.5mm sheet glass ordinary quality white or tinted fixed in aluminium frame in squares exc 0.5 sqm each pane, complete all as specified and directed.
M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F in repair Mortice brass lock of 4 lever, vertical type, size 100 mm , complete all as speicfied and directed.
S&F in repair of aluminum body door closer (extruded section) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repair of Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 140mm complete all as specified and directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and directed by Engr-in-Charge.
S&F of 4mm thick sheet glass, ordinary quality and glazing with oil putty and glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
S&F of 4mm thick figured glass, pin head type and glazing with oil putty and glazing pins in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with galvanised wire staples, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing dismantled tile and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L for 10 mm thick premium quality vitrefied colour tiles , light shade (square/rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc over and including 15mm thick screed bed in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade / colour / matrix of the tiles complete all as specified and directed by Engr-in-Charge.
M&L for Coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in cement mortar 1:6 all as specified and directed by Engr-in-Charge.
S&F in repair 25mm dia aluminium anodised alloy curtain rod including wooden ornamental/ decorative bracket and end cap all as specified and directed.
S&F in repair for SDC Laminated flooring 8mm thick of any coloured, manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base, complete including removal of existing flooring, all as directed by the Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 63 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 100 Amps, 35 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 160 Amps, 36 KA, adjustable type , including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 200 Amps, 36 KA, adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 250 Amps, 36KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 400 Amps,36 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 630 Amps, 50 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
Taking out old UNSV LT panel board / Junction box of any size complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate). Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 200 Amps, 415 Volt, AC ,25 KA = 02 Nos (O/G) (c) MCCB 4 pole, 160 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts = 10 Nos (O/G) (d) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 (e) Phase indicating lamp = 03 Nos (R, Y, B) (f) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate). Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,35 KA = 01 Nos (I/C) (b) MCCB 4 pole, 160 Amps, 415 Volt, AC ,35 KA = 02 Nos (O/G) (c) MCCB 4 pole, 100 Amps, 415 Volt, AC ,35 KA = 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 11 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate). Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC ,25 KA = 03 Nos (O/G) (c) MCB SPN, 63 Amps, 230 Volt, AC, = 04 Nos (O/G) (d) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 (e) Phase indicating lamp = 03 Nos (R, Y, B) (f) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 200 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G)
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- .
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,35 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC ,35 KA = 02 Nos (O/G) (c) On load change over switch (side handled) 4 pole, 100 Amps, 415 Volt = 01 Nos (d) MCB SPN 63 Amps, 230 Voltst, AC = 2 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC1:2:4 type B-1 (using 20mm graded crushed stone aggregate). Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 02 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate). Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 02 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA= 04 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate). Feeder Pillar box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA= 03 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be epoxy powder coated and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be epoxy powder coated Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 160 Amps,240/415 Volt, 50Hz, 10 KA= 01 Nos (I/C) b) MCB SPN 63 Amps, 240 Volts - 04 Nos (O/G) Note : Unit rate quoted by the contractor here-in-before also includes for fixing and connecting of MCBs and installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work shall be in cement concrete 1:2:4 type B1 all as per manufacturer instructions and as directed by the Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
M/S LIBE & CO
M/S TRADE LINK
Ms Salaria Builders
M/S ASHISH AND CO
FORTUNE STAR
M/S KAMLA CONSTRUCTION CO.
EESSI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .