Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.0 L+₹1.5 L (10.5%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹16.2 L+₹1.7 L (11.5%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹17.1 L+₹2.6 L (18.0%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹17.5 L+₹3.0 L (20.5%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L5 | Rejected-Finance High Rate |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
18 Dec 2023, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8440 REPAIR / REPLACEMENT / MAINT TO STREET / SECURITY LIGHT FITTINGS, LANDSCAPE LIGHTINGS, POLE, CABLES AND ALLIED ITEMS IN THE AREA OF AFMC AND OTHER AREA UNDER GE (CENTRAL) PUNE
2023_MES_630461_1
8440 REPAIR/ REPLACEMENT/ MAINT TO SECURITY LIGHT
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Pune
₹49,800
Yes
6 Feb 2024
30 Nov 2023
21 Dec 2023
30 Nov 2023
18 Dec 2023
12 Dec 2023
Amount
Excavation in trenches not exc 1.50 Mtr wide and not exc 1.5 Mtr in depth for laying of LT UG cable / poles in soft /loose soil and getting out complete all as specified and directed.
All as per item No 1 above but exc 1.50 Mtr but not exc 3.00 Mtr depth.
Returning filling in incluiding spreading levelling watering and well ramming in layers not exc 25cm depth complete all as specified and diredcted.
Removing excavated material to a distance not exceeding 50 Mtr and depositing where as directed at a level not exc 1.50 Mtr above the starting point all as directed.
M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping of poles fair finishing the exposed surfaces even and smooth without using extra cemen including use and waste of necessary form work including demolition of cement concrete (unreinforced) complete all as specified and diredcted.
M & L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate as in foundation of poles / feeder pillar box repair to floor / paths fencing etc including use and waste of necessary form work completeall as specified and directed.
M & L 40mm bore dia GI tubing ''light grade'' for protection of cable and fixed to existing pole with flat iron clamp 25 x 3mm including nut, bolts and washer including taking up or down existing GI tubing complete all as specified and as directed.
M & L for Reinforced concrete pipes class NP-2 of size 150mm bore dia in 1 RM each half round (for bottom and top ) all as directed. Note :- Two half round pipe (Bottom and top) will be measured asone RM.
Supply, lay, test,connect and commissioning LT underground cable 1100 Volt grade heavy duty XLPE insulated, armoured with aluminum stranded conductor laid in trenches / fixed to poles / drawn through pipes with suitable size cable glands, criping type cable lugs etc including taking out old existing worn ou cable complete complete all as specified and directed of the following sizes :-
(a) 6 Sqmm 2 core
(b) 10 Sqmm 2 core
(c) 10 Sqmm 4 core
(d) 16 Sqmm 4 core
(e) 25 Sqmm 3.5 core
Disconnecting and taking down defective street light fittings from any type / capacity / brand from steel pole at 9 Mtr height using ladder and repairing and refixing after replacement of unserviceable parts like internal wiring, screws, nuts and bolts etc including daily checking and giving workability complete as directed by Engineer-in-charge. Note : (i) Cost of minor items such as Screws, nut, bolts & wiring will be included in quoted rates and No extra payment will be allowed to contractor on this account. (ii) The street light fitting cover shall be cleaned properly as directed during repair works and rate of the same shall be deemed to be included in quoted rates. (iii) Necessary tools, ladder and other testing equipments etc shall be arranged the contractor. (iv) GI Pipe brackets and clamps shall be measured and paid seperately under relevant items.
S & F electronic driver suitable for LED light fitting 30/45 Watt system power of approved make complete all as specified and directed.
S & F electronic driver suitable for LED light fitting 60 Watt system power of approved make complete all as specified and directed.
S & F electronic driver suitable for LED flood light fitting 120-150 Watt system power of approved make complete all as specified and directed.
M & L in replacement of bracket made of GI pipe 40/50 mm dia light grade not less than 1.5 Mtr fixed with 02 Nos of MS clamps fabricated out of MS flat of size 25 x 4mm including nut, bolts, washers and bent to shape etc complete all as specified and directed.
Supply and fix integral LED Street Light Luminaire 45 Watt comprising of powder coated aluminium housing, covered with glass or fiber cover in frame suitable for 50/40 mm GI Pipe complete with accessories internally prewired and 3 core wire and necessary mounting arrangements including taking down old unserviceable fitting all as specified and as directed.
Supply and fix Integral LED Street Light Luminaire 60 Watt comprising of powder coated aluminium housing, covered with glass or fiber cover in frame suitable for 50/40 mm GI Pipe complete with accessories internally pre wired and 3 core wire and necessary mounting arrangements including taking down old unserviceable fitting all as specified and as directed.
Supply and fixing LED FLOOD Light Luminaire 150 Watt comprising of with pressure die-cast hosing and toughened glass and individual LEDs with secondary lens optic with IP-66 ingress protection, 4 KV in built and 10 KV surge protection of efficiency 120 Lm/W complete with all accessories internally prewired and 3 core wire and necessary mounting arrangements including taking down old unserviceable fitting all as specified and as directed.
Disconnecting and taking down defective Bollard light / Post top lattern light fittings of any type / capacity / brand from 1/1.5/2 Mtr height repairing and refixing after replacement of unserviceable parts like internal wiring, screw, nut, bolts etc including daily checkeing and workability complete as directed by Engineer-in-charge. Note :(i) Cost of minor items such as Screws nut, bolts & wiring will be including in quoted rate. No extra payment will be allowed to contractor on this account. (ii) The light fitting cover shall be cleaned properly as directed during repair works and rate of the same shall be deemed to be included in quoted rates. (iii) Necessary tools and other testing equipments etc shall be arranged by the contractor.
Supply and fix new generation Bollard light rectangular shape with opal acrylic diffuser, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution with high power LEDs as light source of Cap 9 Watts IP-65 protection and grouted in foundation sutable bolts, nuts and washers etc including electrical concetion with suitable copper wire from junction box to light complete including taking down old unserviceable fitting fitting complete all as specifide and directed fittings.
Supply and fix new generation, post top, made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear arcylic diffuser and IP-65 protection opal diffuser of cap 25 Watt complete including taking down old unserviceable fitting fitting complete all as specified and directed fittings.
Supply and fix FRP junction box light weight suitable for pole mounting including MCB SP 10 Amps single pole and necasry terminal for loop in loop out cable connection and suitable size glands of size 250 x200x105mm including taking down FRP junction Box all as specified and directed .
Supply & fix timer switch box fabricated out of 16 SWG CRCA sheet of outdoor type with mounting arrangement duly power coated complete including taking down old timer switch box all as directed with consisting of following items :-
(a) Digital Timer - 01 No
(b) Power contactor 80 Amps - 01 No
(c) Terminal connector - 03 Nos
(d) MCCB TP/TPN 100 Amps 415 Volts - 01 No
Supply and fix PVC sheathed insulated wire round or flat in shape with copper conductor 3 core 1.5 Sqmm working voltage 1100 Volt PVC cable, passing through pole, fixed to FRP junction box to street light fitting for 11/9 Mtr long pole including suitable size of lugs for looping including taking down old worn out wire complete all as specified and directed.
Supply and fix Digital time switch with Astronomical Function for switching on / off lights and other electric devices according to the rising / setting of the sun with combination function for creating switching programs in which the devices are switched according to astronomical time and / or fixed preset times, daily astronomical calculation of the sunrise / sunset times based on the entered location or location coordinates complete all as specified and directed.
Supply and fix Power Contactors 4 pole with 230 Volt coil and handle manual over ride for test and repair function carried out via the handle permanent “ON” or “OFF” without automatic closing of the contactor complete all as specified and directed.
S & F for MCB single pole of rated capacity 10 Amps, 230 Volts, breaking capacity 10 KA, B-curve complete including taking down old unserviceable MCB all as directed.
S & F for MCB TPN of rated capacity 63 Amps, 415 Volts, breaking capacity 10 KA, C-curve complete including taking down old unserviceable MCB all as directed.
M & L for preparation of old painted steel surfaces by scraping and removing old paints, rust etc from Steel Tubular Poles of 9/11 Mtr long above ground level (PCC Copings) without removing any acessories and painting the pole with one coat of alumimium paint including clamps, GI bracket etc and writing pole nos with black paint complete all as specified and as directed.
M & L in Replacement earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3mm buried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 Mtr below ground level connected to and including GI wire 4mm dia and GI Protection pipe 15mm bore dia light grade for protection upto the extent of 7.5 Mtr as earthing lead by means of GI bolts, nuts and washers etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I including RCC cover, M S angle iron frame funnel watering arrangement with GI pipe 20mm bore dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete all as specified and as directed. Note : GI earthing wire and 15 mm dia GI protection pipe beyond 7.50 Mtr will be measured and paid separately.
Supply and fix 4 mm dia GI wire as earth continuity conductor or main earthing lead fixed to wall or pole / floor complete all as specified and as directed.
M & L in Replacement earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3mm buried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 Mtr below ground level connected to and including GI strip 32 x 6mm and 40mm bore dia GI pipe light grade for protection upto the extent of 7.5 Mtr as earthing lead by means of GI bolts, nuts and washers etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I including RCC cover and MS angle iron frame, watering arrangement with GI pipe 20mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete all as specified and as directed. NOTE :-GI earth strip and protection pipe 40mm beyond 7.5m will be measured and paid separately
Supply & Fix in replacement for GI strip 32 x 6mm fixed with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed.
M & L in replacement for Aluminium strip 25mm x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed.
Supply & Fix in replacement air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Supply & Fix in replacement of test point terminal block made out of gun metal or Phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screw complete with all fixing accessires complete all as specified and directed.
Taking out existing steel tubular pole of any length from foundation complete with all accessories and romove from existing foundation and shifting the pole to other location and fixing complete with foundation work & connected accessories at other location as per direction of Enginner-in-Charge complete all as specified and directed. Note : Excavation & Earthwork & PCC foundation work including demolition will be measured and paid separatly under relevant items.
PURVA ELECTRICALS AND ENGINEERS
N D ELECTRICAL
Adinath Technical Services
Rama Electricals
CHAITANYA WINDWELL
Gauri Associates
Akanksha Enterprises
SHREE ATHARVARATHI ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .