Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.0 LAccepted-AOC | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹24.3 L+₹1.3 L (5.44%)Rejected-Finance 3 3430 NICHOLSON ROAD KASHMERE GATE DELHI DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹24.8 L+₹1.7 L (7.43%)Rejected-Finance C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹24.9 L+₹1.9 L (8.15%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹25.0 L+₹1.9 L (8.35%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
PERIODICAL SERVICES IN ZONE B AND OTHER MISC LOCATIONS UNDER AGE B R II OF GE N PATIALA MIL STN
2021_MES_452000_1
GE(N)/PAT-28/2021-22
Open Tender
Civil Works
Item Rate
180 days
PATIALA
AS PER NIT
7 documents required · 7 mandatory
₹500
GE NORTH PATIALA
₹50,000
Yes
31 Jul 2021
16 Jun 2021
9 Jul 2021
16 Jun 2021
7 Jul 2021
30 Jun 2021
60 days
Amount
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.
Rendering 15 mm thick in cement mortar 1:4 , mixed with water proofing compound, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement with WPC paid and WPC to be measured separately complete all as specified.
Supply only Water proofing compound complete.
Rendering 10 mm thick in cement mortar 1:6, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement complete all as specified.
Rendering 5 mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement all as specified.
Complete removal of existing treatment of any type/description such as cement base paint, external emulsion etc from external surfaces of walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc with mechanical means/grinder complete all as specified and directed.
Applying wall care putty in external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
Preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Exterior Emulsion : Asian (APEX) / Berger (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL) . Note : The cost for steel tubular double scaffolding necessary for execution of work and protective measures fo rheight more than height of double storey building as directed by Engineer-In-Charge shall be included in the quoted rate against the respective item and nothing shall be admissible for this.
M&L for preparing new plastered surfaces of wall and applying two coats of cement base paint complete.
M&L for preparing old surfaces of wall and applying one coat of cement base paint complete.
Complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/grinder complete all as specified and directed.
Applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
Applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Interior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Interior Emulsion : Asian (TRACTOR) / Berger (BISON) / Nerolac (BEAUTY SMOOTH) .
Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceiling surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Interior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Interior Emulsion : Asian (TRACTOR) / Berger (BISON) / Nerolac (BEAUTY SMOOTH) .
Applying 01 coats of interior emulsion paint (light shade) @ 20 sq.m/litre/1 coats by using roller to old painted wall surfaces and including filling the holes of nails, curtain rod brackets etc to be filled with putty of Birla wall care/ JK/ Bison, by using following brands of emulsion and primer complete all as specified and directed. Make of Interior Emulsion : Asian (TRACTOR) / Berger (BISON) / Nerolac (BEAUTY SMOOTH) .
Applying 01 coats of interior emulsion paint (white shade) @ 20 sq.m/litre/1 coats to old painted surfaces of ceiling by using following brands of emulsion and primer complete all as specified and directed. Make of Interior Emulsion : Asian (TRACTOR) / Berger (BISON) / Nerolac (BEAUTY SMOOTH) .
M&L for preparing old plastered/unplastered surfaces of walls and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge.
M&L for preparing old surfaces of ceiling and applying two coat of white wash on ceiling surfaces complete.
M & L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge. Make : Asian Paints/Berger/Nerolac
M & L for preparing old painted wood & wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge. Make : Asian Paints/Berger/Nerolac
M&L for cutting down plants/trees/bushes of girth not exc 15 cm from roof tops/sides, externals walls of building, chajja wall junctions, junctions of rain water/ CI/ Soil waste/ Vent pipes including taking out roots entered into walls/slab surfaces, then spraying the affected area with solutions of 25 ml Glyphosphate (4% content) diluted with 1 ltr of water or as per manufacture's instructions & making good the surface using PCC (1:2:4), type BO or cement mortar 1:3 as per site requirement with necessary scaffolding/stagging etc. any height from ground level, complete all as specified & as directed by Engineer-in-Charge. Note :-1. Any PVC pipes, brick works damaged during the execution of the work shall be replaced with new one to ensure leak/seepage free joint. 2. The width of such wk will be measured 0.50 sq.m extra beyond roots of the plants.
S&F stainless steel tubing of 25 mm bore mild steel chromium plated 1.6 mm wall thickness as in curtain rod complete incl S & F necessary nos of brackets, stops and fancy type tops at rod ends etc in repairs all as specified & directed.
Taking up or down existing steel tubing and connections, 20mm bore complete all as specified.
S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified.
Refixing old steel tubing and connections in new or old position (walls, ceiling and floors) complete.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in positiong after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of any type and size complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed by Engr-In-Charge
PCC 1:3:6 type C1 (20 mm graded aggregate) as in kerbs . Bands, plinth courses , string courses, apex stones, bed plates etc.
PCC 1:3:6, type B-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100, mixing with liquid water proofing compound complete all as specified and directed. Note : WPC will be measured and paid separately.
Raking out joints/ pointing work built in cement mortar to brick work in walls or to bricks on edge in floors, surface channels, roofs etc complete
M&L for flush pointing laid flat or brick tiles in roofs in CM 1:3 complete.
Removing existing plaster over the affected bricks to be removed using mechanical means. The affected bricks to be completely exposed complete all as specified and directed.
Apparent visible efflorescence to be first cleaned using hard wire brush and all cyrstal deposits to be removed. The bricks shall then be cleaned using soft brush of powdery crystals removed. Then make a 1 to 4 solution of vinegar and water (1 part vinegar to 4 parts water) and apply it to the efflorescence affected area using a nylon brush. Allow the vinegar/ water solution to sit on the surface of the affected area for 15 minutes, but do not allow the solution to dry. Rinse the area with clean water, using low pressure jet. Two cycles of cleaning using vinegar water solution to be repeated complete all as specified and directed.
The joints of bricks so cleaned shall be pointed using cement putty made a site using Sika Latex/SBR polymer diluted at ratio of 1:4 with water. The solution so made shall be used to be mixed with cement to make a putty consistency paste. The cement putty shall be then worked out in the joints which are clean and in SSD condition.
The bricks so pointed shall be cleaned of all dust or deposit using brush. A undiluted single component acrylic polymer-Sika Raintite, to be used to prime the brick surface. The primer while being tacky the first coat of water proofing coating is done, second coat is applied after a time interval of 4-6 hours after the first coat has dried. The water proofing coating shall be two component polymer modified cementitious coating-Sika top seal-107, having a thickness of 1.5mm in two coats. The material to be factory batched and ready to use. The two components shall be mixed using low speed drill having a RPM 350-450 and fitted with a paddle. The mixing to be done for 3-4 mintues to give a brush able consistency mix. The coating shall be done using brush 100-150mm wide brush. It is to be take care that material while being used is agitated every 3-5 mintues to avoid powder part getting settled. The water proofing coating shall have below properties Tensile Strength - 4.56 N/mm2 after 14 days exposure (According to ASTM D 2370) Bond Strength 2.0 N/mm2 at + 27o C (failure in substate). After application of second coat and while the material is still wet, coarse sand is sprinkled over the coating so as to ensure proper mechanical key is provided for subsequent plaster.
M&L for plastering 15mm thick over the treated surface shall be done with 1:4 cement sand plaster added with acrylic polymer-Sika Plastocrete Plus, @ 3% by weight of cement.
Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
M&L for sunken floor treatment without disturbing the existing treatment by applying siliconate injection grouting using nozzles. The spacing of holes will be 2 Nos, holes in every 1.00m, using 12 to 15mm diameter drill bit, drill holes at an inclination of 45 degree to the extent of 1/2 to 3/4 the wall thickness & injecting in the lowset possible point almost touching the defective damp proofing course depending upon the severity of dampness and the materils used in the walls & in its construction. A hand pump sufficient to create pressure of approx 3kg/sqm must inject SIKA chemical through pressure grouting machine, inject the diluted liquid (1:4) by pumping till the point of return of liquid is felt (minimum 10 litres) & allow to remain for some time before moving to the next nozzle & observing the area for 24 hours including removing the extended/protruding nozzles & seal the holes with suitable compound. The treated areas should be washed thoroughly and followed by application of two coats of water based hygienic coat containing in entire scrapped area and including removing of old materials of any description, all as per manufecturer's instruction, making good the holes after treatment complete all as specified and directed. (Make : M/S Build Core, M/S Pidilite, M/S STP as approved by the GE)
M&L for ATT of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cemetn mortar 1:2 (1cement : 2 coarse sand) to match the existing floors and walls complete.
Welding in repairs exc 2.5 cm but n. exc 5 cm in length thickness of metal to be welded exc 20mm but n. exc 25 mm complete all as specified and directed.
Writing letters or figures (block, Roman, Itallic or Indian) of height not less than 10 cm and not exc 30 cm, width of letter shall not be less than 10-15 mm, including stops, commas lines, brackets and making outer border with white synthetic enamel thick paint over base with one coat of black japan paint in any shape as directed by Engr-in-Charge. (Cost of stops, commas, lines, brackets, etc as required shall be deemed included in the quoted rate for letters & figures).
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jonts fixed to wall complete all as specified and directed.
S&F PVC SWR bends any radius complete.
M/s Anil Kumar and co.
M/S Mukesh Kumar Gupta
NORTON BUILDER
KG BUILDERS
M/s Harmans
RUPINDER SINGH SODHI
HG construction
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .