Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest Tenderer | |
| 2 | L2₹45.2 L+₹4.8 L (11.8%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹48.2 L
EMD Value
₹96,360
Closing Date
4 Sept 2024, 6:00 pmClosed
MAJOR ANIL KUMAR S GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8119 ADDITION ALTERATION OF JUNIOR SAILORS DINING AT INS ANGRE AND SPECIAL REPAIR OF ROOF TREATMENT AT COMMAND MET OFFICE MUMBAI BUILDING NO A 70 AND A 50
2024_MES_663781_1
8119/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹96,360
Yes
14 May 2025
3 Jul 2024
6 Sept 2024
10 Jul 2024
4 Sept 2024
17 Jul 2024
3 Jul 2024 - 10 Jul 2024
Amount
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame)
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame)
Taking down shutters of any description not exc 1 sqm each
Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each
S&F 2nd class hard wood (sal) plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified.
S&F 35mm thick factory made 2nd class HW rail & stile plain framed , panelled shutter ( two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated
S&F 32mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side.
S&F 30mm thick 2nd class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. divided in to squares,with plain, chamfered or rounded , mitred and rebated sash bars,any numbers ; edges of framing plain, chamfered or rounded , fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (b) ; supplied and fitted to chowkhats of Second class hard wood.
S&F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type having thickness of laths 1.25 mm complete all as specified and directed.
S&F in repair powder coated aluminium (minimum 25 micron thickness of coating) of various section as required for doors, sliding windows/ partion/Ventilator etc including fixing and making the frames for hinges glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement,in sliding shutter, sealant etc all as specified and as directed by Engr- in- charge.
S&F in repair aluminium grill with and including suitable aluminium anodised frame F/H section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, as directed by Engr- in- charge.
S&F 3mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel stapple etc.
S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts all as specified.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed.
S&F 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked all as specified.
S&F 125mm long Butt hinges, medium weight, cold rolled mild steel, and fixed.
M & L for MS flat for hold fast. Conforming to Fe-290-0 or Fe-165
S&F in repairs 140 mm long floor door stopper of aluminium door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as specified
S & F Aluminium extruded body door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and ofweight not morethan 35 kg and fixed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for all as specified.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and disposing off complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and rubbishing off the premises etc complete all as specified and as directed.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M&L rendering 15mm thick in CM 1:6 on brick surfaces, finished with Neeru finish on walls complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate) as in foundation, filling and mass concrete
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets etc all as directed.
S&F 5mm Prelam PVC sheet in strips & channel feathered at the edges (as per sample) for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified.
S&F Anodised aluminium snap grid size 605x605mm frame work for false ceiling all as specified.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for false ceiling made out of 600x600x 4 mm thick ( non asbestos fiber cement designer/coloured) ceiliing board / tiles deep panel as per sample fixed in flat or sloping.
M&L for POP false ceiling using 600X900x12mm thick plaster of paris with gypsum binder sheet decorative type including two coats of plastic emulsion paint and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50x25 mm spaced at 750 mm centre, secondary joist of size 75X20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25x25x2 mm GI angles and fasteners @ 1.2 M C/C, including dismantling old un serviceable false ceiling, complete all as specified and directed.
S&F in repair 20/25mm Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.type designe and pattern approved by GE, brackets both ends complete all as specified .
Dismantling stone slab and tiles of of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land
M&L for coloured glazed ceramic tiles 450x300x7 mm thick but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM 1:3.
M&L light shade double charged virified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor including 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L light shade double charged vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm (600x600mm), but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM 1:3 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L 20 mm thick mirror polished Granite (of any type) work as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over 15 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
M&L for 18 to 20mm thick green marble (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade.
Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed.
M &L for machine cut kota stone slab flooring 18 to 20 mm thick as in steps, landings, floors etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,mirror polishing incl making 02 Nos grooves in steps over & incl 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M &L for machine cut kota stone slab 18 to 20 mm thick as in skirting/vertical surfaces jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
Grinding and polishing existing floor of any type (Kota stone, mosaic, cuddappa stone etc) all as specified and directed.
S&F mild steel framed work such as grills, gratings,chequred plates etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; walkj ways, railings, frame work for water tanks and similar work conforming to Fe 290 Gd E-165 all as specified .
Taking up or down existing GI water tubing complete with all fittings of 15 mm bore
Taking up or down existing GI water tubing complete with all fittings of 20 mm bore
Taking up or down existing GI water tubing complete with all fittings of 25/32 mm bore
S & F 15 mm bore UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, celing etc or in floors etc
S & F 20 mm bore UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, celing etc or in floors etc
S & F 25 mm bore UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, celing etc or in floors etc
S&F in repairs fancy type CP stop/angle cock of 15 mm dia, screwed for iron pipe and fixed as per sample and directed by Engr-in-Charge.
S&F in repairs fancy type bib cock 15 mm dia, screwed for iron pipe and fixed complete as directed by Engr-in-Charge.
S&F in repairs fancy type CP Pillar taps 15 mm dia, cast copper alloy, with capstan heads, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified.
S&F 600mm PVC connections 15 mm size with PTMT nuts
Taking down CI/PVC/AC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 100/75 mm dia pipe.
S & F 110mm bore PVC (SWR) pipes single socketed in any length wirh rubber ring joints fixed to walls.
S & F 75mm bore PVC (SWR) pipes single socketed in any length wirh rubber ring joints fixed to walls.
S & F PVC (SWR) bends 110 mm
S & F PVC (SWR) bends 75 mm
S&F PVC (SWR) bends any radius provided with access door of 110 mm dia
S&F PVC (SWR) bends any radius provided with access door of 75 mm dia
M&L in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement75 mm dia.
S& F in repairs 125 mm dia stainless steel grating fixed in position complete
Taking down PVC wastage and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and directed by EIC
S&F 160 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floor etc with and including fixing clips bends elbow, shoes bends etc (Note :- Measurement shall be taken along the centre line of the pipes) complete all as specified and as directed.
S&F in repairs 160 mm dia bore PVC (SWR), single/double 'Y' or 'T' with access doors any radius including fixing clips complete all as specified and as directed .
Preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of of primer all as specified and directed.
M&L for preparation of newly wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer incl preparation of surfaces.
M&L for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper all as specified and directed
M&L for preparation of old decorated surfaces of ceiling and applying one coat of oil emulsion distemper complete all as specified and directed.
M&L preparation of old decorated surfaces of walls, soffits, roof facia & applying one coat of weather proof acrylic based paint (100% acrylic) with necessary scafolding etc all as specified & directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamel paint with necessary scafolding for high rise bldgs etc all as specified and directed.
M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint including external window with necessary scafolding for high rise bldgs.
Removing any kind of debris including loading in truck and conveying day to day basis to approved dumping point i.e @ urban / industry loading spreading etc. complete with all leads and lifts (lead 50km)
M &L for rendering 20 mm thick pre polymer modified ready mixed cement based plaster in two coats 12 mm thick base coat and 8 mm thick finishing/final coat. Polymer modified ready mixed cement based plaster should having minimum composition of cement and sand 1:4 using fully treated dry, well graded natural sand confirming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties , mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size and necessary two legged MS pipe scaffolding as wherever required incl curing required in high rise building complete all as specified and directed.
M&L Examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder upto 5 -10 mm depth without damaging existing rebars, carefully removing unsound weak/ loose concrete/ cover & concrete around the rebars upto 10 mm depth by low impact high frequency hammer/ chipper without damaging the sound concrete, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, disposing off the debris so generated on weekly basis outside the premises, etc, complete all as specified and directed necessary scaff -folding complete all as specified and directed 3.00 Sqm
M&L for cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and applying two coats of alkaline rust converting primer Sika RustOff 100 or ReArm Rust Remover with brush on the existing rebar for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days including surface preparation. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, complete all as specified and as directed by Engr-in-charge Note: Work to be executed by the authorised applicator of manufacturer only.
M&L for Drilling & Re baring of 12 mmdia x 120mmdeep, thoroughly coated with Zinc based reinforcement epoxy AquaArm CoatZP complete all as specified and as required.
M&L Providing and Application Aqua Arm Coat-ZP as passivator/ Anti corrosion coating to the steel reinforcement shall be applied The material shall be two component cement based polymer modified two component coating for corrosion protection. The material shall be prepacked and ready to use. It shall be fully compatible with the reinstatement methods adopted complete all as specified and as directed by Engr-in-charg. This shall include surface preparation and erection of steel props as required for the application complete all as specified and directed . Note: Work to be executed by the authorised applicator of manufacturer only.
M&L of two component solvent free epoxy bonding agent Sika Sikadur 32LP/ ReArm Superbond or equivalent for bonding old to new concrete . The ready to use epoxy bonding agent shall be applied over old concrete using brush after cleaning of surface of all dust or latiance. The material is supplied as a two part material in pre weighed quantities for ready onsite mixing and use.2.The new concrete shall be placed within the open time as specified by the manufacturer to ensure maximum bonding and application shall be as per the manufacturer instruction , complete all as specified and as directed by Engr-in-charge. Note: Work to be executed by the authorized applicator of manufacturer
Rebuilding the section of damaged RCC elements to its original size in thickness of 25mm by hand or spray application by Providing and applying Sika MonoTop@- 122F single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortar or by micro concreting in the ratio of 1:2:4 added with water proofing admixture WP-10 or Sika Latex SBR as specified or directed by engineer incharge. Note: Work to be executed by the authorised applicator of manufacturer
M&L for preparation of newly plastered surfaces of wall, soffits, facia roof and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L Complete removal of existing treatment of old decorated surfaces of walls soffits, facia roof and applying two coat of weather proof acrylic based paint (100% acrylic) over one coat of cement base primer with necessary scaffolding for high rise bldgs. etc all as specified.
S&F 200 mm dia bore PVC (SWR) half round pipes single socketed, in any length with rubber ring joints, fixed with MS clamps suitable for rain water gutter all as specified and directed.
S&F 160mm dia bore PVC (SWR) bends any radius
Taking up or down existing GI water tubing complete with all fittings of 20 mm bore
S & F GI tubing medium grade galvanised with all fittings fixed complete to walls and ceilings or laid in floors 20mm bore of tube .
Dismantling water tank of capacity exc. 1000 Ltrs but n.exc. 2000 ltrs.
S&F rotational moulded polythylene water storage tank tank (cylindrical vertical with closed top) hoisted and fixed in position of 2000 ltr capacity including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for inron pipe and fixed (minimum weight 210 grms ) all as specified in SSR Part I.
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down with water and applying two coats of oil bound distemper over a coat Chalk whiting, on plastered surfaces,
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material for schedule of credit and making good to disturbed surfaces as directed by Engineer-in-Charge
M&L for point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC Conduit with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall as per site requirement/metallic terminal boxes concealed in wall suitable for modular accessories with cover plate and frame including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly including modular box and cover plate all as specified.Notes: a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green b) Make of wire : Polycab/ Havells/ Finolex/Plaza/Benlo c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit/PVC Casing Capping. Note : - PVC Casing Capping will be used where PVC conduit not feasible.
One light point controlled by one 5A switch
One Fan point/Exhaust fan point controlled by one 5A switch
One Bell point control by one 5A bell push switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L for point wiring complete with 2.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make drawn through & including PVC Conduit with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall as per site requirement/metallic terminal boxes concealed in wall suitable for modular accessoriesi with cover plate and frame including one PVC insulated & unsheathed multistranded copper conductor 2.5 Sq. mm as earth continuity conductor connected to common earth dolly for single board having 1 x15 Amp switch socket point for independent board complete including required size and numbers moduler box and cover plate all as specified & directed. Note : - PVC Casing Capping will be used where PVC conduit not feasible.
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, ISI marked, not less than 25mm PVC Conduit with all accessories such as tee, bends, elbow, reducers, junction box etc fixed on wall/ceiling/truss with PVC non metallic ISI make terminal boxes fixed on wall as per site requirement/metallic terminal boxes concealed in wall suitable for modular accessoriesi with cover plate and frame and one run of PVC insulated unsheathed, multistranded copper conductor cable of 4.0 sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including required number and size of modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately. Note : - PVC Casing Capping will be used where PVC conduit not feasible.
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed by EIC.
S & F modular switch 1 way 6A all as specified and directed by EIC. Make: Roma/Legrand
S & F modular switch 1 way 16 A all as specified and directed by EIC. Make: Roma/Legrand
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC. Make: Roma/Legrand
S & F modular socket outlet,6/ 16A,2 module all as specified and directed by EIC. Make: oma/Legrand
S&F for modular fan regulator fan step regulator, 120W - 2 modular step type Make: Roma/Legrand
S & F moduler bell push 6A, 1 module all as specified and directed by EIC.
S&F Ding dong AC 230Volts single pole bell 50 Hz all as specified and directed.
S&F on replacement of hanger clamp assembly with down rod up to 3 feet for hanging of ceiling fan with nuts,bolts,washers & split pin complete all as specified & directed by EIC.
Disconnecting and taking down the fan and Overhauling of ceiling fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust, rust and applying two coat white enamel paint over a coat of steel primer, assembling and refixing at same position complete all as specified.
Disconnecting and taking down the fan and Overhauling of exhaust fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust, rust and applying two coat gray paint over a coat of steel primer, assembling and refixing at same position complete all as specified.
Supply and fixing in repair new generation Down light /15/12 Watt LED PDC aluminium housing downlights, high quality ecomonic energy saving light complete all as specified and directed. Bajaj/Wipro/Jaguar Cat No LULT01S020XC5XN/Wipro/Bajaj/C&S
Supply and fixing in repair new generation ultraslim LED panel recessed LED 2X2 Luminaire 36 watt, CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting Suitable for 600 x 600 mm modular/POP/Gypsum ceiling. Make : Jaguar cat No LSVR01S036XC/Wipro/Bajaj/C&S
Supply and fixing in repair new generation wall/surface mounted 1x 20W LED batten fitting, 4 feet surface mounted provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : C&S/Wipro/Jaguarcat No LGLZ01x020XC/Bajaj
Supply and fixing in repair of LED 60W Street/building security light fittings with high pressure die cast housing with toughened glass and individual LED with secondary optics and IP66 protection complete all as specified and directed by EIC. Make : Wipro/C&S/Jaguar cat No LSRT01S060XC
Supply and fix in replacement MS arms bracket 30 degree bend, 1.5mtr long for mounting one in nos street light fitting including clamps / nut / bolts & washer to brace the same properly with duly painted in synthetic enamel paint of two coat in silver colour complete all as specified and directed by the Engr-in-Charge.
M&L for sub-main wiring with 2 runs of 2.5 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC conduit/casing capping of suitable size with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
M&L for sub-main wiring with 2 runs of 6.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC conduit/casing capping of suitable size with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
S&F in repair sheet metal enclosure VTPN 12 Way,415V with 250 A copper busbar, double door type IP-43, IK-09 protection suitable for housing MCCB upto 160 Amp 3 pole incl required numbers of suitable size of gland complete etc all as specified and directed by EIC. Make: Siemens/Legrand /GE Note : DBs shall be conceeled in wall where ever posible including making good the surface to match with surrounding. Make: Legrand/ Seimens/GE
S & F in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar, IP 43, IK 09 suitable for flush mounting and surface mounting complete etc all as specified and directed. Make: Legrand/ Seimens/GE
S & F in repair MCCB 3P 100 Amps,16KA,thermal magnetic,415volts complete all as specified and directed. Make : Legrand cat No 420015/Seimens/GE
S & F in repair MCCB 4P 160 Amps,25 KA, thermal magnetic,415volts complete all as specified and directed. Make : Legrand cat No 420016/Seimens/GE
S & F in repair MCB SPN40 A to 63 Amps,10KA , 'C' curve Make: Legrand/ Seimens/GE
S & F in repair MCB SP 6-32 Amps,10KA, 'C' curve, Make: Legrand/ Seimens/GE
S & F in repair MCB SP 40 Amps,10KA, 'B' curve, Make: Legrand/ Seimens/GE
M & L in repair for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed by EIC.
M&L in repair JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set incl Supply of Eco Friendly weather proof High Density Polyethylene Earth Pit Chamber Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
M&L in repair for 25x4mm GI earth strip continuity conductor or main earthing lead fixed to wall or buried in ground or drawn in conduit/ pipe or fixed to panel body/motor body/any other equipment complete all as specified
Disconnecting & taking down old Unservicable cable & Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and directed by Engr-in-Charge. Make: Polycab/havells/Finolex.Gloster
Disconnecting & taking down old Unservicable cable & Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core complete all as specified and directed by Engr-in-Charge. Make: Polycab/havells/Finolex.Gloster
S& F in repair GI cable tray perforated type 2 mm thick of size 250x50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter cable trucking for plain to be fixed on any wall (brick/stone) vertically/horizontally including all accessories complete bending,shaping,drilling,welding, cutting & all fixing arrangement complete etc all as directed
Supply, install, Test and commissioning wall mounted Split type AC 2.0 TR capacity units indoor/outdoor complete with cordless remote control unit, 220-240 volt, 50Hz, single phase fitted with high quality rotary compressor air ioniser and Plasma filter for better indoor air quality with min 3 star rating complete as directed. Note :(a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted. Make : Voltas/LG/Hitachi/Daikin
Supply and fix Single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240V all as directed. Make : Legrand/C&S
M & L Submain wiring with 2x 4 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one PVC insulated & unsheathed multistranded copper conductor 4.0 Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly. Make Of Wire : Polycab/Plaza/Havells/Gloster
S & F and clamping jointing copper tubing for suction line and for liquid discharge incl duly insulated with suitable insulation material including making hole in wall for passing through amd making to the disturb surface complete.
S&F for Rigid non-metallic PVC conduit 20mm dia with complete of all tees, bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed
SHREE JAGDISH FURNITURE CO. (BID ID -3068888)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .