| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.5 L+₹55,610 (1.19%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹48.5 L+₹1.6 L (3.43%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹48.8 L+₹1.9 L (4.03%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹48.8 L+₹1.9 L (4.09%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
13 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8005/B/E8
2021_MES_489585_1
GE/ALP (8005B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
334 days
GE ALIPORE KOLKATA
Class D and Category c (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹92,000
Yes
20 Dec 2021
22 Nov 2021
14 Dec 2021
22 Nov 2021
13 Dec 2021
6 Dec 2021
60 days
Amount
Material and labour for replacement of 80-100 mfd Starting capacitor for water cooler of capacity 80/ 150 ltrs, make : Sarda/ Power or equivalent.
Material and labour for replacement of running capacitor 10 mfd for Water Cooler of capacity 80/ 150 ltrs, make : Sarada/Power or equivalent.
Material and labour for replacement of 15mm bore brass chromium plated push cock suitable for water cooler of any capacity as per existing shape and make or equivalent.
Material and labour for replacement of Thermostat switch for water cooler, make : Indfoss or equivalent
Material and labour for replacement of Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of size 15 mm
Disconnecting defective sealed compressor unit of Water Cooler 40/80 ltrs capacity from the water cooler and carryout repair/reconditioning work and re-fixing repaired/ reconditioned sealed unit compressor in original position after testing complete all as specified and as directed.
Disconnecting defective sealed compressor unit of Water Cooler 150 ltrs capacity from the water cooler and carryout repair/reconditioning work and re-fixing repaired/ reconditioned sealed unit compressor in original position after testing complete all as specified and as directed.
Material and labor for replacement of Door gasket for 150 ltrs capacity Water Cooler
Material and labor for replacement of Door gasket for 80 ltrs capacity Water Cooler
Material and labour for replacement of Starting Relay suitable for water cooler 80/ 150 ltrs capacity
Material and labour for replacement of Overload protector suitable for Water Cooler of capacity 150 ltrs
Material and labour for replacement of Overload protector suitable for Water Cooler of capacity 80 ltrs
Material and labour for replacement of Starting relay box type for Refrigerators of capacity 280 ltrs
Material and labour for replacement of Capillary copper tube of size 0.36 mm for Refrigerators of capacity 280 ltrs
Material and labour for replacement of Freezer door for Refrigerators of capacity 280 ltrs
Material and labour for replacement of Thermostat switch (Make : Indfoss/Kelvinator) for Refrigerators of capacity 280 ltrs
Material and labour for replacement of Chill tray for Refrigerators of capacity 280 ltrs
Disconnecting defective condensor coil of Refrigerators 280 ltrs capacity and replacing the same with new condensor coil and fixing in original position as per existing
Material and labour for replacement of Inner lights for Refrigerators of capacity 280 ltrs
Disconnecting defective sealed compressor unit of Refrigerators 280 ltrs capacity and carryout repair/ reconditioning work and re-fixing repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed.
Material and labour for replacement of Door switch for Refrigerators of capacity 280 ltrs
Material and labour for replacement of 5 Amps, 230 Volts Plug Top.
Material and labour for Dismantling the cover of Condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base , discaling with chemicals, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for following capacity of Air Conditioners: -
Window Type Air Conditioner of capacity 1.5 TR
Window Type Air Conditioner of capacity 2.0 TR
Split type Air Conditioner of capacity 1.5 TR (1 x Indoor unit and 1 x Outdoor unit)
Split type Air Conditioner of capacity 2.0 TR (1 x Indoor unit and 1 x Outdoor unit)
Split type Air Conditioner of capacity 3.0 TR (1 x Indoor unit and 1 x Outdoor unit)
Split type Air Conditioner of capacity 5.5 TR (2 x Indoor unit and 1 x Outdoor unit)
Supply and fixing as in replacement AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit of carrier/Voltas/LG/Amtex.
Material and labour for repair of AC single phase 230 volt Printed Circuit Board for 1.5/ 2.0 TR capacity split type AC cooling unit of carrier/Voltas/LG/Amtex
Material and labour for repair of AC single phase 230 volt Printed Circuit Board for 3/ 5.5 TR capacity split type AC cooling unit of carrier/Voltas/LG/Amtex
Supply only as in replacement AC single phase 230 volts remote (Hand set) for 1.5/ 2.0 TR capacity split type AC of carrier/Voltas/LG/Amtex complete all as specified and as directed by the Engr-in-Charge.
Supply only as in replacement AC single phase 230 volts remote (Hand set) for 3/ 5 TR capacity split type AC of carrier/Voltas/LG/Amtex complete all as specified and as directed by the Engr-in-Charge.
M&L for Re-winding of Blower motor including replacement of bushes with same size and gauge of wire for Split/ Window type AC 1.5 TR capacity (Condensing unit)
M&L for Re-winding of Blower motor including replacement of bushes with same size and gauge of wire for Split/ Window type AC 2.0 TR capacity (Condensing unit)
M&L for Re-winding of Blower motor including replacement of bushes with same size and gauge of wire for Split type AC 3 TR capacity (Cooling unit)
M&L for Re-winding Blower motor including replacement of bushes with same size and gauge of wire for Split type AC 5 TR capacity (Cooling unit)
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split/ Window type AC 1.5 TR capacity (Condensing unit)
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split/ Window type AC 2.0 TR capacity (Condensing unit)
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split type AC 3 TR capacity (Cooling unit)
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split type AC 5 TR capacity (Cooling unit)
Material and labour for replacement of Strainer for Split/ Window Type AC of any capacity.
Material and labour for replacement of 4 micro farad capacitor for blower moter of AC of any capacity, make: Sarda/ Power or equivalent.
Material and labour for replacement of 6 micro farad capacitor for blower moter of AC. Make : Sarda/Power or equivalent.
Material and labour for replacment of 36 micro farad running capacitor of split/window type AC. make: Sarda/ Power or equivalent.
Material and labour for replacment of 40 mfd running capacitor of split/window type AC. Make : Sarda/ Power or equivalent.
Material and labour for replacment of 50 mfd running capacitor of split/window type AC. Make : Sarda/ Power or equivalent.
Material and labour for replacement of 80-100 mfd Starting capacitor of split/window type AC. Make : Sarda/ Power or equivalent.
Material and labour for replacement of 100-120 mfd Starting capacitor of split/window type AC. Make : Sarda/Power or equivalent
Material and labour for replacement of Thermostat switch for 1.5 TR capacity Window Type AC, make: Indfoss or equivalent.
Material and labour for replacement of Sensor for 1.5/ 2.0 TR capacity Split type AC, make: Indfoss or equivalent
Material and labour for replacement of Sensor for 3/5.5 TR capacity Split type AC, make: Indfoss or equivalent
Material and labour for replacement of Fan Blade for 1.5/2 TR capacity Window type AC.
Material and labour for replacement of Fan Blade for 3/5.5 TR capacity Split Type AC
Material and labour for replacement of Over load protector for Window/ Split Type AC of capacity 2 TR, make : Shriram/ Arbind or equivalent.
Material and labour for replacement of Over load protector for Window/ Split Type AC of capacity 1.5 TR. Make : Shriram/Arbind or equivalent.
Material and labour for replacement of Capillary copper tube of size 0.064 inch dia
Material and labour for replacement of Runner for 1.5/ 2.0 TR Window Type AC.
Material and labour for replacement of Runner for 3/5.5 TR Window Type AC.
Material and labour for replacement of Runner for Indoor unit of 1.5/ 2.0 TR Split Type AC.
Material and labour for replacement of Runner for Indoor unit of 3/5.5 TR Split Type AC.
Material and labour for replacement of Starting Relay for window/ Split type AC of capacity 1.5/ 2.0 TR, make: Shriram/ Arbind or equivalent.
Material and labour for replacement of Starting Relay for window/ Split type AC of capacity 3/5.5 TR, make: Shriram/ Arbind or equivalent.
Material and labour for replacement of Front cabinet for 1.5 TR Window Type AC
Material and labour for replacement of Air filter for 1.5 TR Window Type AC
Material and labour for replacement of Base tray for Window Type AC of 1.5 TR capacity
Material and labour for replacement of 16 Amps, 3 pin, 240 Volts Plug top.
Material and labour for replacement of Plug top for earth plug socket of capacity upto 30 Amp.
Disconnecting defective sealed receprocating type compressor unit of 1.5 TR Split/ Window/ Package type AC from the system and carryout repair/ reconditioning work and re-fixing repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed
Disconnecting defective sealed receprocating type compressor unit of 2 TR Split/ Window/ Package type AC from the system and carryout repair/ reconditioning work and re-fixing repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed
Disconnecting defective sealed receprocating type compressor unit of 3 TR Split/ Window/ Package type AC from the system and carryout repair/ reconditioning work and re-fixing repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed
Disconnecting defective sealed receprocating type compressor unit of 5.5 TR Split/ Window/ Package type AC from the system and carryout repair/ reconditioning work and re-fixing repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed
Supply and laying out of copper pipe (hard) 5/8" dia with PUF insulation CFC free etc as required at site complete all as specified and as directed by the Engr-in-Charge.
Supply and lay out of copper pipe (hard) 3/8" dia with PUF insulation CFC free etc as required at site complete all as specified and as directed by the Engr-in-Charge.
Cleaning the cooling coil and condensor with the help of compressed Nitrogen inner side of the copper tube for flushing out all sludge and oil deposited in the copper tube and materials and labour for charging of refrigerant R-22 as required including replacement of strainer and finding out the leakage, brushing the same, testing for following capacity of AC complete all as specified and as directed by the Engr-in-Charge:- (a) Split/Window type Air conditioner 1.5/ 2.0 TR capacity
Cleaning the cooling coil and condensor with the help of compressed Nitrogen inner side of the copper tube for flushing out all sludge and oil deposited in the copper tube and materials and labour for charging of refrigerant R-22 as required including replacement of strainer and finding out the leakage, brushing the same, testing for following capacity of AC complete all as specified and as directed by the Engr-in-Charge:- (a) Split/Window type Air conditioner 3/5 TR capacity
Supply and fixing MCB protected Power Unit with 16 - 25 Amp MCB, Motor Starter, Socket and Plug Top with indicating light of make: North West/ Havells or equivalent.
Material and labour for charging of Refrigerant R-22 in Split/ Window AC, Water Cooler and Refrigerator
All as per item No 74 above but Refrigerant R-12/ R 134A
Material and labour for replacment of Drier of 5.5 TR Ductable AC Copper wire superior quwality with all necessary arangment complete all as specified and as directed by the Engr-in-Charge.
Dismantalimg and Refixing in another place with marking good old and new surface with servicing of Indoor and outdoor unit for 1.5/2 TR Split AC with all necessary arangment complete all as specified and as directed by the Engr-in-Charge.
Material and labour for Re- winding of motor of capacity UP to 40 HP of AC plant with super enamelled copper wire
Dimantling existing old unservicable HEPA filter from Air handling unit duct and M&L for new Hepa filter of EU 13 Normal flow , Media construction microscopic fiber glass + Aluminium separator of 99.99 % Efficency, Particals to be filtered Down to 0.3 Micron, initial pressure droop 25 mm of water guage, Final pressure droop 60 mm of water guage
Supply and Fixing AHU air Pre filters .5 micron suitable for AHU
Supply and Fixing AHU air Fine filters .5 micron suitable for AHU
Supply and Fixing air filters .3 micron suitable for TFA
Supply and Fixing air filters .5 micron Pillow type suitable for TFA
Material and labour for Compressor oil suitable for package type AC.
M&L for Sensor for controlling temperature of 60TR AC plant including taking down old make : Blue Star or as per existing.
Supply and Fixing in repair MCB 6 to 32 Amp Single Pole, 230V, make : Legrand or equivalent make as per list of make.
Supply and Fixing in repair MCB 40 to 63 Amp TP, make : Legrand or equivalent make as per list of make.
Supply and Fixing in repair MCCB , 500 Amp ,4 Pole L& T Cat No CM94002OOT1OG or equivalent make as per list of make.
Supply and Fixing in repair 20HP VFD for secondary pump
Suppy and fixing in repair VLT suitable for 200 TR AC Plant 15 KW/20 HP Make;- DANFOSS OR equivalent complete all as specifierd and as directed.
Supply and Fixing in repair HP Switch, Make : Danfos / Indfos / ALCO
Supply and Fixing in repair LP Switch, Make : Danfos / Indfos / ALCO
Supply and Fixing in repair contactor AC3 rating 40 Amp, make: L&T, type ML 3 of or equivalent
Supply and Fixing in repair 3 pole power contractor AC3 rating 32 Amp, make: L&T, type ML 2 of or equivalent
Supply and Fixing in repair Condensor Refrigerant sensor
Supply and Fixing in repair Discharge line temperature sensor
Supply and Fixing in repair Evaporator leaving/ entering water pair sensor
Supply and Fixing in repair Condensor leaving/ entering water pair sensor
Supply and Fixing in repair Thermal overload relay direct mounting 14 to 23 Amp, make: L&T, Cat No SS94135OODO or equivalent
Supply and Fixing in repair Thermal overload relay direct mounting 20 to 33 Amp, make: L&T, Cat No SS94136OOEO or equivalent
Supply and Fixing in repair Thermal overload relay direct mounting 30 to 50 Amp, make: L&T, Cat No SS94136OOGO or equivalent
Supply and Fixing in repair K Smart AC Panel controller
Supply and Fixing in repair K Smart CARD suitable for AC temprature controller
Supply only nitrile ruber 13mm
Material and labour for painting with one coat of red oxide primer and two coats of black japan paint including preparation old/new surface of steel of any description complete all as specifierd and as directed.
Supply and Fixing in repair PCB Display Board for Screw compressor 200 TR
Supply and Fixing in repair Solonoid Valve Kit CXH9
Supply and Fixing in repair Pressuer Transducer 44.8 BAR
Supply and Fixing in repair Pressuer Transducer 10. BAR
Supply and Fixing in repair Solenoid valve coil oil line, Make - Trane / Parkar
Supply and Fixing in repair Solenoid valve coil Loader/ Unloader line, Make - Trane / Parkar
Supply and fixing in repair channel, angle, or tee sections fixed independently, without connecting plates etc. (cut to ordinary lengths as required and making shape, drilling hole etc complete all as specified and directed.
M&L for mild steel Plates (plain or chequered), square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed as per requirement.
RADHA ENTERPRISE
SUDHA ENTERPRISES
KWALITY CONSTRUCTION
ELECTRO FREEZE
INDIA ELECTRICAL EQUIPMENTS
M/S J S ENTERPRISES
UNIVERSAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .