Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Low | |
| 2 | L2₹19.7 L+₹1.8 L (9.96%)Rejected-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L2 | Rejected-AOC High | |
| 3 | L3₹20.7 L+₹2.8 L (15.3%)Rejected-AOC | L3 | Rejected-AOC High | |
| 4 | L4₹21.0 L+₹3.0 L (16.8%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-AOC High | |
| 5 | L5₹21.3 L+₹3.3 L (18.5%)Rejected-AOC | L5 | Rejected-AOC High |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A P SINGH, IDSE, CWE CHANDIMANDIR
HQ CWE CHANDIMANDIR
CA NO. CWE/CHM(U)-25/2022-23 REPAIR AND MAINT OF 11 KV HT VCBs and RMUs, OUTDOOR SWITCHES AND CONNECTED ITEMS AT VARIOUS LOCATION UNDER GE (U) CHANDIMANDIR
2022_MES_530910_1
CWE/CHM(U)-25/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMANDIR
Class D and Cat b(ii)
8 documents required · 8 mandatory
₹500
Yes
GE (U) CHANDIMANDIR
₹52,000
Yes
15 Sept 2022
14 Jun 2022
30 Jul 2022
14 Jun 2022
27 Jul 2022
29 Jun 2022
15 Jun 2022 - 23 Jun 2022
Amount
Servicing/maintenance of ring main unit (RMU) 3/5 way 11 KV of any make, by disconnecting the power supply, visual inspection, general cleaning of the unit using blower/soft cloth, cleaning of all the contacts/bus bars etc with CRC solution and fine emery paper and removing all carbon deposits due to flashings, applying superior quality petrolium jelly on all contacts, checking and tightening all hardwares, checking all components/insulators/studs, adjusting male/female bushings in proper spacing, checking suitability and correct operation of protections, control instruments and electrical connections of the circuit breaker operating mechanism , verification of wiring circuits, lubricating all moving parts, checking/rapairing and properly adjustment of opearting system, checking operation of functional locks, interlocks, signalling devices and auxiliary devices, measurement of the resistance of the main circuit , checking for any gas leakage, making all HT supply connections and testing for proper working complete all as specified and directed.
Repairing/maintenance/servicing of HT 11 KV VCB along with CTs/PTs of capacity upto 1250 A of any make and type by drawing out breaker from panel and carry out the following works complete all as specified :- (a) Tripping off the breaker and racking out the breaker trolley complete from the panel for servicing/inspection/overhauling. (b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and adjusting for proper operation. (c) Servicing/Inspecting/checking of circuit spouts and circuit spout connections for RYB phases. (d) Checking of cross bar assembly, fixed contacts and current carrying parts of the breaker complete. (e) Cleaning/decarbonizing of all fixed and moving contacts, levers, springs, etc with soft emery paper , CRC solution and soft dry cloth to remove all carbon deposits and tightening all screws, nuts, bolts, spring etc and incl applying superior quality petrolium jelly on all contacts. (f) Checking of safety/tripping relays and AC/DC power supply circuits for proper functioning .(g) Checking, setting and adjustment of rack in/rack out , spring charging system and operation of the breaker trolley.
(h) Lubrication and greasing of breaker operating mechanism , all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear etc. (j) Checking of all end terminals, tightening of all earth connections, tightening all hardware, rack-in the breaker, put in position, engage the VCB with the supply system and testing for smooth functioning. Notes : (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape etc. and testing and commissioning all as specified and as directed by the Engineer-in-Charge. (ii) Servicing/maintenance of VCBs shall be carried out by auhtorised service centre/agency/rep of any SEB as approved by GE.
Auxiliary Switch (7 NO+7NC) as per existing size/type and suitable for 11 KV VCB of any make and type (approved by GE) as in repairs complete all as specified and directed.
Tripping coil assembly 24 volts DC suitable for 11 KV HT VCB of any make (approved by GE) and as per existing size/type as in repairs complete all as specified and directed.
Closing coil assembly 24 volts DC suitable for 11 KV HT VCB of any make and as per existing size/type (approved by GE) as in repairs complete all as specified and directed.
Space heater 240 volts single phase as per existing size/type and suitable for 11 KV VCB of any make (approved by GE) as in repairs complete all as specified and directed.
Thermostat for space heater , single phase range 0 to 90 degree celcius all as per existing size/type and suitable for 11 KV VCB of any make (approved by GE) complete all as specified and directed.
Drive link assembly with adjustor as per existing size/type and suitable for 11 KV HT VCB of any make and type (approved by GE) as in repairs complete all as specified and directed.
Supply only Rack in rack out handle as per existing size, type and suitable for 11 KV VCB of any make/ type (approved by GE) complete all as specified and directed.
Supply only Spring Charging Handle as per existing size, type and suitable for 11 KV VCB of any make/type (approved by GE) complete all as specified and directed.
Voltage transformer ratio 11 KV/110 volts confirming to IS-3156 1992, 50 Hz, class B insulation with primary voltage 11 KV/RT3 and secondary voltage 110 V/RT3, 50 VA, class 1.0 3P, type phase to earth complete incl making all connections as in repairs complete all as specified and directed.
HT current transformer suitable for 11 KV HT RMU having ratio 200-100/1 A, burden 4 VA, 50 Hz , Class 5P, accuracy level factor 10 complete making all connections and testing for proper working as in repairs complete all as specified and directed.
HT current transformer suitable for 11 KV HT VCB of any make , having ratio 400/200-5 amps or 300/150-5 amps or 200/100-5 amps accuracy class 1.0 5P10, 10 VA, 50 Hz incl making all connections as in repairs complete all as specified and directed.
DC power pack with battery back up , input 230 volts AC and output 24 volt DC , capacity 100 watt 4 amps complete with operation indicators , terminal block, safety fuse etc and making connections with the existing circuits in HT VCB panels as in repairs complete all as specified and directed. Note. ALAN TYPE APP230024 or equivalent as approved by GE.
Disconnecting and taking out protection relays/trip relays of any make and any type from HT panel boards , cleaning all the contacts properly, calibrating the relays by conducting secondary injection tests, checking of current transformers, checking the complete wiring circuits and rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relays, reinstallation of relay into the system, making all connections, testing & commissioning complete all as specified and directed.
Relay provided on HT 11 KV SF-6 RMU panels for incoming and outgoing feeders for healthy tripping for over current and earth fault self powered numerical protection relay and testing for proper working as in repairs complete all as specified and directed.
Single pole high speed master tripping relay suitable for working on 24 volt DC, high burden type, flush mounting, with output contacts 3 N/O 1 N/C and hand reset opeartion indicator suitable for 11 KV HT panel for protection system as in repairs complete all as specified and directed.
Feeder protection relay with features of overload relay tripping, 3 phase over current and earth fault tripping suitable for working on 24 volt DC or 220 volts sigle phase AC as per existing, flush mounting, suitable for 11 KV HT panel for feeder protection system as in repairs complete all as specified and directed.
Disconnecting power supply and taking out old defective batteries from the DC supply power panel, general cleaning of DC supply panel , supply and fixing new maintenance free lead acid sealed batteries 2 volt 100 AH capacity - 15 nos and making all series connections, checking and repairing the power circuit for proper charging and AC/DC supply changeover , checking all the circuits and replacing any defective parts such as relays etc, testing and commissioning complete all as directed.
Supply and filling SF-6 gas to maintain required pressure in RMU complete all as directed.
RMU SF-6 breaker mechanism system suitable for ABB safe plus breakers as in repairs complete all as per existing and all as directed.
Copper connection for C.T. With nut, bolt and double washers for 11 KV VCB as in repairs of any make all as per existing (approved by GE) complete all as specified and directed.
Vacuum interrupter suitable for 11 KV HT VCB of any make/type (approved by GE) 800 amps capacity complete all as per existing size and type as in repairs complete all as specified and directed.
Spring loaded tulip contact, suitable for 800 amps 11 KV HT VCB as in repairs of any make/type (approved by GE) complete all as specifed and directed.
Spring loaded tulip contact, suitable for 1250 amps 11 KV HT VCB as in repairs of any make/type (approved by GE) complete all as directed.
Duct covers made from chequred MS plates incl cutting to required shape as per site requirement, painting with two coats of black enamelled paint over a coat of red oxide primer all as specified and as directed.
HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 70 to 95 Sqmm, 3 core complete all as specified and directed.
HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
HT heat shrinkable type outdoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 240 sqmm, 3 core complete all as specified and directed.
HT heat shrinkable type outdoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 240 Sqmm, 3 core complete all as specified and directed.
Three phase digital type voltmeter with input 0-110 VAC and range 0-11 KV AC , accuracy ± 1.0% ,PTR 11 KV/V3/110V/V3 , square shape size 96x96 mm , flush mounting type ,on the HT 11 KV panel boarrds at various locations all as per existing incl making all connections with control wiring and testing for proper working as in repairs complete all as specified and directed.
Three phase digital type ammeter with input 0-5 AAC and range 0-200 AAC , accuracy ± 1.0% , square shape size 96x96 mm , flush mounting type ,on the HT 11 KV panel boarrds at various locations all as per existing incl making all connections with control wiring and testing for proper working as in repairs complete all as specified and directed.
Contact arm suitable for HT 11 KV VCB of 800 amps capacity as in repairs of any make and type (approved by GE) complete all as specified and directed.
Chequred rubber mat for electrical purpose ISI marked of size 1 mtr X 2 mtr and 19 mm thickness all as specified and as directed.
Electric motor 230 volts AC suitable for operating mechanism of HT 11 KV VCB of of any make/type (approved by GE) complete all as per existing and testing for proper functioning as in repairs complete all as specified and directed.
Door handle kit suitable for HT VCB 11 KV 630/800/1250 amps capacity of any make, (approved by GE) for proper locking of the main door as in repairs complete all as specified and directed.
Bus bar spoute bushing suitable for HT 11 KV VCB panel board as in repairs of any make and type (approved by GE) complete all as specified and directed.
Seal of RMU gas chamber/bottle after disconnecting of all the connections and remaking all connections for 11 KV HT RMU as in repairs of any make and type (approved by GE) complete all as specified.
HT danger notice plate of size 250mm x 200 mm on 11 KV HT VCB panels as in repairs dully pasted complete all as specified and directed.
LED indicators on the existing HT 11 KV panel boards as in repairs all as per existing size/colour as approved by GE complete all as specified and direccted.
Three way control swich for ON/OFF opeartion of 11 KV HT VCB as in repairs all as per existing and as approved by GE complete all as specified and directed.
Rewiring of the complete control circuits of 11 KV HT VCB of any make with single core copper conductor cable of size as per existing for metering/safety relays/indicators/charging system/tripping closing wiring circuits/ connections from CTs,PTs/cubical lamp & socket/thermostat & space heater/Dc power supply system for relays etc incl numbering ferrules for marking of the circuits complete all as specified and directed.
Disconnecting and taking out feeder pillar box of any type and size all as directed
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 2009 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Jai Maa Electrical Works
Shree Balaji Construction
NARINDER KUMAR SONS
Vasudeva Trading Co.
R D Bansal
Alpha Engineers and Builders
M/S BALWINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .