Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹6.2 L+₹52,372.20 (9.15%)Rejected-Finance | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
8 Oct 2022, 6:00 pmClosed
Major A R Thakkar
GE (P) Dappar
Provn of urinal point, Garbage bins at various location and one toilet in NSI at Mil Stn Dappar under GE (P) Dappar
2022_MES_551295_1
GE (P) DPR-19/2022-23
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (P) Dappar
₹16,000
Yes
16 Dec 2022
12 Sept 2022
10 Oct 2022
12 Sept 2022
8 Oct 2022
23 Sept 2022
12 Sept 2022 - 23 Sept 2022
Amount
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified
M & L for PCC 1:4:8 Type D2 usingg (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 5mm thick in cement mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement plastering 15mm thick in cemet mortar (in twor layers 10 mm+5mm) 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified and as directed. Make : Pidilite/Sika/Fosroc/STP
M&L for preparation of newely plaster surfaces on wall and applying two coats of cement based paint over chalk whiting on plastered surfaces all as specified.
M&L for preparation of newely plaster surfaces on wall and applying three coat of white wash complete all as specified.
M&L for preparation of newely plaster surfaces of ceiling and applying three coats of white wash complete all as specified.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing for butt hinge ISI Marked 100mm size, medium weight, cold rolled mild steel complete all as specified and as directed.
S & F 150mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing for ISI Marked 150mm long aluminium, anodized, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge
M & L for hardcore of broken stone or boulders exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface, complete all as specified
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40mm graded aggregate as in sub base of floor all as specified.
M & L for 40mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate as floor finish complete all as specified and as directed by the Engineer-in-Charge
M & L for 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate as in floor complete all as specified and as directed by the Engineer-in-Charge
M & L for Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match OVER 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
M&L for glazed ceramic coloured tiles in vertical surfaces such as skirting,dados and riser to steps etc size 350mmx250mmx7mm/450mmx350mmx7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 10mm thick plaster CM (1:4) complete all as specified.
Supply only glass dividing strips, 3 mm thick 38mm wide
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
Preparation of newly or previously untreated steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
S&F Expanded metal, cut to length, bent to shape required andtying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members exc 4sqm /kg complete all as specified
M & L for reinforced Cement Concrete 1:2:4 type B1 using 20mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC 1:2:4 Type B1 using 20mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M&L formwork to sides and soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup• ports, overhangs, etc. also splays between floors and beams, etc. for fair finished flat surfacecomplete all as specified and directed by Engr-in-Charge.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M&L Mild steel TMT bar 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders, cut to length, bent to shape required including cranking bending spirally hooping for column, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips quality conforming to, as in stirrups, spaces and binders complete all as specified and directed by Engr-in-Charge.
S & F of 15mm size PVC connections with PTMP nuts of length 450mm complete all as specified and as directed by the Engineer-in-Charge
M & L for 75mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed by the Engineer-in-Charge
M & L for 75mm bore diaPVC (SWR) floor trap, plain with grating including jointing with solvent cementcast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) bends of any radius, complete all as specified
S & F 75mm bore PVC (SWR) bends of any radius, complete all as specified
S & F 75mm bore PVC (SWR) vent cowl, complete all as specified
M & L for 15mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and as directed by the Engineer-in-Charge
M & L for 20mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and as directed by the Engineer-in-Charge
M&L cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting n. exc 10 cm girth complete all as specified.
Supply and fixing for ISI marked 15mm bore bib tap of cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-Charge.
M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge
S & F of for ISI Marked 20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F of ISI marked 20mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by the Engineer-in-Charge.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100mm bore pipe line complete all as specified and as directed by the Engineer-in-Charge
S & F Pillar Tap of 15mm bore dia, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S&F viterious china white wash hand basin flat back white in colour ISI marked of size 550mm x 400mm with chromium plated waste coupling and PVC waste pipe fixed to walls with CI breckets 2 Nos embedded in CM 1:4 type complete all as specified.
S&F 10 ltr PVC valveless syphonic action type flushing cistern with brackets flush pipe etc complete including inlet ball valve float and handle including brackets of approved make including all connections & flush pipes for WC complete all as specified.
S&F viterous china squatting pan Orrisa pattern size 580 x 440mm white with "P" and "S" trap front or back inlet etc including connectipon to trap and to flishing to pipe , anti syphonage pipe etc incl provisioning of lime concrete complete all as specified.
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe completed all as specified and directed.
S&F Vitreous china urinal partition white of size 310x700 mm. completed all as specified and directed.
S&F Soap dish, any type, fixed to plugs with chromium plated brass screws completed all as specified and directed.
S&F for 32 mm dia PVC waste pipe for wash hand basin / Kitchen sink etc complete all as specified.
S&F of Angle valve 15mm bore stop valve, fancy type, brass chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed
S&F brass chromium plated tublar towel rail, 20mm dia, D type 60cm long between flanges completed all as specified and directed.
Supply Fixing 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
S&F for 15 mm dia angular stop valves of chromium plated with long shank and cup cocealed type screwed down high pressure with crutch or butterfly handle complete all as specified.
S&F grating doom 100mm dia of PTMT (min weight 25gms) complete as specified and directed
M&L for colourd Machine pressed precast concetet interlocking paver block 60mm thickrubber moulded any shape and size over 25 mm thick sand layer conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and pigments complete all as specified.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in cills, lintels, upto 1.50 metre clear span, copings, benching, bed plates etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works complete all as specified and as directed.
M&L 50 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protection. Complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed.
Removing Excavated soils not exceeding 50M and depositing where directed at a level not exceeding 1.5 M above the starting point.
M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated PVC unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:- Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting PVC conduit and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall.
(a) One light / fan / Bell point controlled by one switch
(b) One socket outlet 5 Amps on the same board with other switches.
S&F Modular switch 10 A, 1 module type single pole 240 volts of Anchor Roma Urban Cat Pat Code No 66101 10AX, 1Way Switch,HSN Code 8536 or equivalent in Legrand/Schneider specified colour complete all as specified and directed by the Engr-in-charge.
S&F Modular socket with safety shutter 10Amps 2/3 pin combined 2 module 240 Volts of Anchor Roma Urban Cat Pat Code No 66403, HSN Code 8536 or equivalent in Legrand/Schneider in specified colour complete all as specified and directed by the Engr-in-charge.
S&F modular cover plate with frame 8 module of Anchor Roma Urban Cat Pat Code No 66808SL, HSN 8538 or equivalent in Legrand/Schneider in specified colour complete all as specified and directed by the Engr-in-charge.
S&F Modular Metal Box 8 module and complete all as specified and directed by the Engr-in-charge .
Supply and fixing in replacenment Modular Angle holder Cat Pat NO 33958 of Anchor Equivalent/Havells/SSK with insulated body with back plate for LED lamps all as specified and directed by the Engr-in-charge .
Supply and fixing in replacement LED lamp 9 watt, retrofit all as specified and directed by Engr-in-charge complete.Make Havells/Philips/CG
S&F in replacement LED tube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as directed by Engr-In- Charge.
Supply and fixing in replacement ceiling rose bakelite, 63.5mm 3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB SP 6 -32 Amps,10 KA,,'C' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
S&F Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V,4 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. Make : Legrand/ABB/Schenider
Supply and fixing in replacement MCB SPN 06-32 Amps,10 KA 'c' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
Supply and fixing in replacement mirror light fitting LED 10W, 230 V, 2ft all as per Crompton Make Cat No. - LCL-14-CDL or equivalent in Philips/Wipro complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Bulk Head LED 10W, 230 V, 2ft all as per Crompton Make Cat No. - LBHE-10-CDL or equivalent in Philips/Wipro complete all as specified and directed by Engr-in-Charge.
M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and directed by Engr-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering steel body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed by Engr-in-Charge.
M&L Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable size of cable 2x2.5 sqmm (line conductor) & 1x2.5 sq mm (earth conductor). 1100 V grade drawing in & includingheavy duty non metalic PVC conduit, ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core copper conductor cable, green in colour as in earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note : (i) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
Supreet Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .