Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.8 LAccepted-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-1 | Accepted-AOC L-1 Accepted | |
| 2 | L-2₹25.0 L+₹18,106 (0.73%)Rejected-AOC | L-2 | Rejected-AOC L-2 Rejected | |
| 3 | L-3₹27.2 L+₹2.4 L (9.68%)Rejected-AOC 2 SHANTI NAGAR SECTOR 3 HIRAN MARGI UDAIPUR 313002 | UDAIPUR | UDAIPUR | RAJASTHAN | 313002 | L-3 | Rejected-AOC L-3 Rejected |
Tender Value
₹31.2 L
EMD Value
₹62,463
Closing Date
21 Mar 2022, 11:00 amClosed
AGM(E-E),AAI, Belagavi Airport
Engineering Offices, Belagavi Airport, Sambra, Belagavi, Karnataka- 591124
SITC of Airfield Lighting Control and Monitoring System (ALCMS) including AICMC for Five Years at Belagavi Airport
2022_AAI_107591_1
SITC of ALCMCS i/c AICMC
Open Tender
Electrical Works
Item Rate
120 days
Belagavi Airport
Refer Tender document.
16 documents required · 16 mandatory
₹1,180
₹62,463
11 Jul 2022
28 Feb 2022
22 Mar 2022
28 Feb 2022
21 Mar 2022
28 Feb 2022
28 Feb 2022 - 11 Mar 2022
Amount
SH-I: SITC of ALCMS
Design, supply, installation, testing & commissioning of Airfield Lighting Control & Monitoring System (ALCMS), Type 'L 890 BB' as per the requirements of FAA Advisory Circular No. AC 50/5345 - 56B (Current edition) and additional circuits / mechanisms / interfaces for control & monitoring of constant current regulators (CCRs) & fixed circuits such as Landing - H, Wind cones, Apron High Mast flood lights, Beacon lights etc., as mentioned in Annexure-I, to make them compatible with ALCMS, Data & Power Cabling, Earthing etc., including spare PLC and I/O modules, all hardware and software, licenses & other items as required for successful operation of the system in line with the scope of work, details of equipments, equipments specification, performance criteria etc., complete as required. Two vault processor should be provided both running in parallel for redundancy in operation etc as required. (ALCMS Make: ADB Safegate/Eaton Crouse – Hind/Flight Light/Honeywell/ NASU Systems/Electro Systems)
SH-II: Supply and Laying of OFC cable
Supply and laying of Single mode 6 core, armoured Optic Fibre Cable (OFC) (ISI marked) conforming to ITU-T G.652 and IEC- 60794 with up to date amendments, etc., complete as required through HDPE pipe of 40 mm dia.
Supply and laying of HDPE pipe of PN 6 and PE 63 of following size ISI marked, HDPE pipe along with all accessories like socket, bend, couplers etc., conforming to IS 4984 with upto date amendments complete as required direct in ground at a depth of 0.75m below the ground level i/c excavation and refilling the trench but excluding sand cushioning and protective covering etc. as required. 40 mm dia
Supply and laying of HDPE pipe of PN 6 and PE 63 of following size ISI marked, HDPE pipe along with all accessories like socket, couplers etc., conforming to IS 4984 with upto date amendments complete as required on wall surface/cable tray with necessary Clamps/Cable ties at required intervals as required. 40 mm dia
Supply and laying of HDPE pipe of PN 6 and PE 63 of following size ISI marked, HDPE pipe along with all accessories like socket, bend, couplers etc., conforming to IS 4984 with upto date amendments complete as required in the existing Cable trench / Hume Pipe / masonry duct. 40 mm dia
Supply and fixing of Single mode 6 core, armoured Optic Fibre Cable (OFC) (ISI marked) conforming to ITU-T G.652 and IEC- 60794 with up to date amendments, etc., as loop inside the vault processors/Open duct/ surface including providing cable tie/ mounting clamps etc., complete as required.
Supply and laying of 1.1 KV grade 16C 2.5 mm2 armoured Copper conductor XLPE insulated and PVC sheathed control cable as per IS - 7098 (Part - I) 1998 respectively with upto date ammendments, etc., complete as required. through HDPE pipe of 40 mm dia.
Supply and laying of 1.1 KV grade 8C 2.5 mm2 armoured Copper conductor XLPE insulated and PVC sheathed control cable as per IS - 7098 (Part - I) 1998 respectively with upto date ammendments, etc., complete as required. through HDPE pipe of 40 mm dia.
SH III: AICMC OF ALCMS
All inclusive comprehensive maintenance of complete ALCMS & other related hardwares and softwares including all spares and consumables, providing full support during breakdown & trouble shooting, programming, carrying out quarterly routine maintenance checks, preventive and breakdown maintenance etc. as required as per good engineering practices, recommendations of the respective equipment manufacturers and instructions of engineer-in-charge for maintaining the systems. This includes keeping the system in acceptable functional and serviceable state etc. as specified including cost of all spare parts.
First Year (after Completion of DLP) Rate for First Year after DLP = 3 % of SH-I i.e. SITC cost of ALCMS SH - I Sl. No. 1.01
Second Year (after Completion of DLP) Rate for Second Year after DLP = 5 % escalation of SH-III Sl. No. 3.02 cost
Third Year (after Completion of DLP) Rate for Third Year after DLP = 5 % escalation of SH-III Sl. No. 3.03 cost
Fourth Year (after Completion of DLP) Rate for Fourth Year after DLP = 5 % escalation of SH-III Sl. No. 3.04 cost
Fifth Year (after Completion of DLP) Rate for Fifth Year after DLP = 5 % escalation of SH-III Sl. No. 3.05 cost
NASU SYSTEMS
MPC ELECTRICALS AND ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .