Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.9 LAccepted-AOC 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L1 | Accepted-AOC Accepted being L1 bidder and rates being reasonable | |
| 2 | POTHIRAJ and CO L2₹87.4 L+₹2.4 L (2.85%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
25 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
81342 PROVISION OF HARDSTANDING FOR RAPID ERECT SUN SHELTER (RESS) AT INS PARUNDU, RAMNAD UNDER GE TIRUNELVELI
2020_MES_336674_2
81342
Open Tender
Civil Works
Item Rate
180 days
TIRUNELVELI
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE TIRUNELVELI
₹1.6 L
Yes
27 Jul 2020
28 May 2020
26 Jun 2020
28 May 2020
25 Jun 2020
4 Jun 2020
60 days
Amount
Excavation over areas in any type of soil, not exceeding 1.50 metre deep and getting out complete all as specified as directed
Rolling and consolidating formation surface in cutting using power rollers of capacity exceeding 8 tonne and not exceeding 12 tonne including filling in hollows and depressions which occur during the process of rolling using approved earth, complete all as specified and directed.
Granular Sub base (GSB) , 250 mm thick minimum (Compacted thickness) in two layers of 125 mm each, compacted seperately, conforming to grading as per MORTH specification, spread, rolled and consolidated to required gradient and camber complete using necessary mechanical paver/grader and tandem vibratory roller/earth compactor of capacity exceeding 08 tonne and not exceeding 15 tonne capacity or using recommended compaction methodology, at OMC, to achive 98% Maximun dry density (MDD) determined using Modified Procter Density determination method as per IS code, complete as specified and as directed. Note:- (a) Cost of rolling and compaction of filled GSB is also deemed to be included in the unit rate quoted under this item. (b) Payment shall be made for solid quantity arrived after compaction (c) Curing shall be carried out as per IRC Reommendations.
Wet Mix Macadam (WMM) , 150 mm thick minimum (Compacted thickness) in two layers of 75 mm each, compacted seperately, with coarse granite stone aggregates of specified grade, spread, rolled and consolidated to required gradient and camber complete using necessary mechanical paver/grader and tandem vibratory roller/earth compactor of capacity exceeding 08 tonne and not exceeding 15 tonne capacity or using recommended compaction methodology, at OMC, to achive atleast 98% density of MDD determined using Modified Procter Density determination method as per IS code, on prepared sub-grade, complete as specified and as directed. Note:- (a) The rate quoted shall be for 150 mm thick consolidated thickness in two layers (each layer of 75mm thick compacted thickness). (b) Each layer shall be rolled and consolidated seperately. (c) WMM sall be as per MORTH specifications as detailed in particular specifications.
Dry lean concrete (DLC) of average thickness 100 mm, M 15 with minimum cement content of 290 kg / Cum, using 20 mm graded stone aggregate, spread, rolled and consolidated to required gradient and camber complete using necessary mechanical paver and tandem vibratory roller of capacity exceeding 8 tonne but not exceeding 12 tonne, complete all as specified and as directed. Note: DLC shall be as per MORTH specification as detailed in Particular specifications
Material and labour for sand filling under floors or in foundation including watering and consolidation etc... complete all as specified and directed.
High Density Polythene film (transparent colour) grade-I confirming to IS 10889, in single layer of 400 micron thickness and weight not less than 380 gms/Sqm, virgin quality laid over sand layer with side end overlapping not less than 300 mm complete all as specified and as directed. Note:- (a) Measurement shall be taken for net area and unit rate quoted shall be deemed to include for overlapping. (b) Sand layer will be measured and paid seperately under relevant item of schedule.
Pavement Quality cement concrete (PQC) work in pavement of flexural strength 45 kg/sqcm (lower control limit - LCL) in field using minimum 400 kg per Cubic meter or as per design mix, mixed with and including triangular/ non circular synthetic polyster fibre reinforcement @ 0.25 % by weight of cement, laid using fixed form paver in bays/panels between joints, including use and waste of necessary steel formworks to the sides including bullnosing/ rounding off the edges and finishing the surface as directed for receiving epoxy coating, complete all as specified and as directed.
Note:- (a) Construction joints/dummy (contraction joints) and expansion joints shall be measured and paid seperately under respective items. (b) Deduction shall be made in computing concrete quantity for exansion joints. (c) No price adjustment shall be applicable if excess quantity of cement than the minimum is used/approved based on mix design, in the execution of work under this item. (d) Cost of admixures to maintain as required by design mix is deemed to be included in the rate quoted. (e) Triangular/ non circular synthetic polyster fibre reinforcement shall measure and paid separately. (f) Epoxy coating shall be measured and paid seperately under relevant items of Sche "A".
Supply only triangular/ non circular synthetic polyster fibre reinforcement
Material and labour for preparing of concrete surfaces by means of scrubber (Machine & Mannual) and washing with sufficient water and applying 4.2 mm thick chemically resistant, self levelling epoxy polyurethene flooring including epoxy base coat/priming coat of 200 micron built-up thicknes, followed by screed coating of built up thickness of 2000 micron and finally providing top self levelling finish coat with a built-up thickness of 2000 micron complete as per authorised and approved manufactures instructions and complete all as specified and as directed.
Note for Sl item No. 10 here-in-before:- (i) Before commencement of work, sample test floor of size 2Mtr x 2Mtr has to be laid as per the procedure detailed in the particular specifications and post-inspection, GE shall give clearence for commencing the work. (ii) The colour pigment of the Epoxy Polyurethene shall be as approved by GE after verifying the sample flooring. (iii) The coating work shall be carried out under supervision of expert Engineers and technicians of the manufacturer and the rate quoted is deemed to include for this aspect. (iv) Epoxy flooring to be executed after covered shelter is erected by users, since epoxy floor surface should not be exposed to moisture or direct sun light.
Material and labour for preparing of concrete surfaces and applying priming coat with FOSROC Nitoprime 25 and two coats of expoxy resin floor coating with FOSROC Nitoflor FC 150, minimum 400 micron thick (based coat & final coat, 200 micron each), applied complete all as per manufacturers instructions and all as specified and as directed.
Material and labour for providing plain cement concrete (1:4:8), type D2, using 40 mm graded stone aggregate as in foundations, filling and mass concrete all as specified and as directed.
Material and labour for brick work with sub class "B" burnt bricks, straight or curved on plan exceeding 6 mtrs mean radius, built in CM (1:4) complete all as specified and as directed.
Material and labour for providing plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping including necessary use and waste of formwork, complete all as specified and as directed.
Material and labour for 15 mm thick rendering on fair faces of brick work in cement mortar (1:4), finished even and smooth without using extra cement, complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil, complete all as specified and directed.
Forming construction joints, 24 mm deep and 8 mm wide (Using diamond cutter), providing polyethylene backup rod 10 mm dia and sealed with polyurethane sealant ( Minimum depth of sealant above polyethylene rod shall be of 10 mm) complying with BS:5212, BS:4254 and EN-41875-2003 (for hydrolysis/water resistance test), priming the sided, minimum movement accomodation factor (MAF) +/- 30 % with ten year performance guarantee and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surface to give neat finish to the sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed.
Note:- (a) The make of polyethylene rod shall be of brand "DURA Rods" manufactured by M/s Supreme Industries Ltd or equivalent make as approved by GE. (b) The polyethylene rod shall be of desired diameter having minimum density of 22 kg/Cum and compression strength of 0.40 kg/Sqm, 25% greater than the joint width, of white colour. (c) Primer to be used before filling sealant. (d) Edges shall be bevelled and joints cut within 24 Hours using Diamond bit cutters of Bosch or equivalent used for cutting green concrete.
Forming 25 mm wide expansion joints, filled with compressible synthetic filler board, for complete depth of joint, i.e, 250 mm, Provision of polyethylene backup rod 30 mm dia and sealed with polyurethane sealant (Depth of sealant above polyethylene rod shall be 21 mm) complying with BS:5212, BS:4254 and EN-141875-2003 (for hydrolysis/water resistance test), priming the sides, minimum movement accomodation factor (MAF) +/- 30 % with ten year performance guarantee and applying masking tape on edge of joint to prevent accedental spillage of sealant on top surface to give neat finish to the sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed.
Note:- (a) The make of filler board shall be of brand "DURA board HD 100" manufactured by M/s Supreme Industries Ltd or equivalent make as approved by GE. (b) The synthetic filler board shall be premouded compressible black in colour having minimum density of 100 (+/-) 10% kg/Cum, water absorption less than 0.09 kg/Sqm and compression recovery of 93%. (c) The make of polyethylene rod shall be of brand "DURA Rods" manufactured by M/s Supreme Industries Ltd or equivalent make as approved by GE. (d) The polyethylene rod shall be of desired diameter having minimum density of 22 kg/Cum and compression strength of 0.40 kg/Sqm, 25% greater than the joint width, of white colour. (e) Primer to be used before filling sealant. (f) Edges shall be bevelled and joints cut within 24 Hours using Diamond bit cutters of Bosch or equivalent used for cutting green concrete.
Forming Contraction (Dummy) joints, 60mm deep with 3mm width as initial cutting and secondary cutting of 24 mm deep from the top and 6 mm wide using diamond cutter to accomodate polyethylene backup rod 8 mm dia and sealed with polyurethane sealant (Minimum depth of sealant above polyethylene rod shall be 10 mm) complying with BS:5212, BS:4254 and EN-41875-2003 (for hydrolysis/water resistance test), priming the sided, minimum movement accomodation factor (MAF) +/- 30 % with ten year performance guarantee and applying masking tape on edge of joint to prevent accedental spillage of sealant on top surface to give neat finish to the sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawing and all as specified and as directed.
Note:- (a) The make of polyethylene rod shall be of brand "DURA Rods" manufactured by M/s Supreme Industries Ltd or equivalent of makes lists here in after. (b) The polyethylene rod shall be of desired diameter having minimum density of 22 kg/Cum abd compression strength of 0.40 kg/Sqm, 25% greater than the joint width, of white colour. (c) Primer to be used before filling sealant. (d) Edges shall be bevelled and joints cut within 24 Hours using Diamond bit cutters of Bosch or equivalent used for cutting green concrete.
Material and labour for preparation of newly prepared surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Material and labour for providing 75 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded stone aggregates, as in flooring, hardstanding, plinth protection etc..., finished even and smooth without using extra cement, complete all as specified and as directed.
Removing excavated material exceeding 500 Mtr but not exceeding 1.50 Km and depositing where directed complete all as specified and as directed.
Supply and fix rotational moulded polyethylene water storage tanks 1000 ltrs capacity, three layer (cylindrical or vertical with closed top) hoisted and fixed in position, including dismantling the existing one and removing to MES storeyard, including supply and fixing 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with connected fittings, complete all as specified and directed.
Supply and fix, gun metal globe or gate valve, with iron wheel head, 20 mm dia bore of pipe, screwed both end for iron pipe, complete all as specified and directed.
Supply and fix, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe and fixed. (Minimum weight for 20 mm 210 gms), 20 mm dia bore of pipe, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth and getting out in any type of soil complete all as specified and as directed.
Removing excavated material exceeding 250 Mtr but not exceeding 500 Mtr and depositing where directed complete all as specified and as directed.
Cutting the existing GI tubing of 50mm bore, inserting "T" of size 50 x 50 x 40 mm for 40 mm GI pipe extension and making good the existing line complete all as specified and directed.
Supply and fixing GI tubing, galvanised, medium grade including all fittings of size 40mm dia bore complete all as specified and directed.
All as per Serial item No. 30 here-in-before but 25 mm dia bore
Supply and fix, gun metal globe or gate valve, with iron wheel head, 40 mm dia bore of pipe, screwed both end for iron pipe, complete all as specified and directed.
All as per Serial item No. 32 here-in-before but 25 mm dia bore
Material and labour for Construction of brick masonry valve chamber of size 1000 x 1000 x1000 mm (Internal dimensions) with PCC foundation (1:4:8) type D2 using 40mm graded stone aggregate, 150 mm thick, 150mm wide offsets alround, 230 mm thick brick masonry walls using sub class 'B' bricks built in CM (1:6), 50 mm thick PCC (1:3:6) type C-1 coping finished even and smooth, rendering 15 mm thick in cement mortar 1:4, finished even and smooth without using extra cement both internally and externally upto 150mm below GL, 40 mm thick flooring with PCC (1:3:6) type C-1 laid over 75mm thick hard core including necessary excavation earthwork in any type of soil, 3.15 mm thick MS sheet cover fixed on 50 x 50 x 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handles and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 Mtrs etc..., complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point, complete all as specified and as directed.
Supply and spread fine river sand in trenches for cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. Note: (i) Only punned thickness of river sand shall be measured (ii) Riddled earth shall be used in lieu of river sand after obtaining written permission from GE.
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and lay UG cable XLPE PVC insulated armoured sheathed heavy duty,1100 V grade, with multi stand aluminium conductor, of size 3.5 core 25 sqmm laid in trenches or wall through cable protection pipes all as specified and as directed.
Supply and fix MCCB, 4 pole, 3 Phase, 415 Volts, 100 Amps, 36 KA breaking capacity all as specified and as directed.
Supply, install, test and commission LT feeder box, factory made, powder coated, dust and vermin and weather proof outdoor, CPRI approved, pedestal type made out of 3 mm thick MS sheet with angle iron frame 50 x 50 x 6 mm thick, front operated, roof canopy, double door type with locking arrangements, providing bus bar for phase and neutral with PVC sleeves for phase indication, 3 phase, 4 wire system, 415 V, 50 Hz AC supply including interconnection with solid conductor/ strips/ wires/ cables with PVC tapes/sleeves of RYB colours, including suitable adopter boxes with spreader links for connecting cables of switch terminals complete comprising the following and all as specified and as directed:-
Material and labour for earthing complete with copper earth plate of size 600 x 600 x 3 mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to 20mm x 3mm copper strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal dust, salt, PCC M-15 type B1 in pit with precast RCC M-15 type B1 in cover reinforced with XPM not less than 4Kg per Sqm, test point etc, all as shown in electrical plate No 3 of SSR Part - I (2009) Specifications complete with necessary earth work in any type of soil, removal to a distance n.exc 100 m, including testing on completion, complete all as specified and as directed by Engineer-in-Charge. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc...
POTHIRAJ and CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .