Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.4 L+₹40,915.50 (1.46%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹31.4 L+₹3.4 L (12.1%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹35.8 L+₹7.8 L (27.7%)Rejected-Finance HIG 05 SECTOR G LDA COLONY KANPUR ROAD LUCKNOW 226012 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226012 | L4 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
13 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF CERTAIN SANCTIONED WORKS IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2021_MES_451838_4
GE/EM/LKO/HOSP/T-19 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category a (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹55,000
Yes
30 Nov 2021
23 Oct 2021
15 Nov 2021
23 Oct 2021
13 Nov 2021
1 Nov 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes line ,foundation, manhole etc. and getting out including trimming the sides and forming bottom surfaces foundation, manholes etc to required levels in soft/loose soil , complete all as specified and directed by Engineer-in-Charge.
All as per item No 2 above but depth exceeding 1.5 and not exceeding 3 metres
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in foundations filling, bed of manhole and mass concrete or in sub base to floor, complete all as specified and directed by Engineer-in-Charge.
Brickwork with Brickwork with Fly ash bricks (bricks shall be burnt clay flyash building bricks as per IS- 13757), straight or curved on plan exceeding 6.0 m mean radius built in cement sand mortar 1:6 ,complete all as specified and as directed by Engineer -in-Charge
Plain cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregates as in coping,padding and bed block, wall through and the like including weathering slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed by the Engineer in Charge.
Rendering 15 mm thick on other than fair faces of brick work, or concrete surfaces in cement mortar 1:6 finished even & smooth without using extra cement,complete all as specified and directed by Engineer-in- Charge.
Rendering 15 mm thick in cement plaster 1:6 on fair faces of bricks work or concrete surface etc complete all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick on fair faces of brick wall or concrete surface in cement mortar 1:6 finished even and fair complete all as specified and directed by Engineer-in- Charge.
Rendering 15mm thick in two layers 10 mm as rendering coat and 5mm as setting coat with water proofing compound on brick work/ concrete on fair surface in cement mortar 1:4 & finished even and smooth without using extra cement complete all as specified and directed by Engineer-in- Charge.
Rendering 10mm thick on concrete surface in cement mortar 1:6 finished even and smooth without using extra cement ,complete all as specified and directed by Engineer-in- Charge.
Rendering 5mm thick on concrete surfaces in ceiling in cement mortar 1:3 finished even and fair without using extra cement using complete all as specified and directed by Engineer-in- Charge.
Preparation of newly plastered or unplastered surfaces of walls by brooming down and priming plastered and other surfaces with with two coats of cement base paint over a coat of cement base primer including ,complete all as specified and directed by Engineer-in- Charge.
Dismantling post or struts (wood/steel or rcc) any section incl taking out embedded portion and making good distrubed on normal ground in concrete, brick works masonary complete all as specified and directed by Engineer-in-Charge.
Dismantling expanded metal, any thickness or mesh, fixed with steel or wood fillets of any weight not exceeding 4 kg sqm,complete all as specified and directed by Engineer-in-Charge.
M S work as in Hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and countersunk for balusters, nosing to steps including embeding in concrete and securing bolts for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc fillets including all necessary drilling bolting or reveting etc and similar work conforming Fe-290 Gde E-165 ,complete all as specified and directed by Engineer-in- Charge.
Mild steel Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts , including,securing or tying at crossings with and Provision of galvanised mild steel wire , staples or steel pins etc. complete all as specified and directed by Engineer-in- Charge. ( each line wire to be measured)
M&L for two coats of synthetic enamel paints over a coat of zinc chrome primer including preparation of surfaces of any description n exc 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep & getting out in soft/loose soil including removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point, complete all as specified and directed by Engineer-in-Charge.
M&L for type C2 1:3:6 (40 mm graded aggregate) cement concrete in foundation and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 10 mm dia and over as in reinforcement cut to length , bent to shape required, including cranking, bending spirally for hooping ends for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia, complete all as specified and directed by the Engineer in Charge.
Mild steel bars (TMT bars) 8mm dia as in reinforcement cut to length, bent to shape required, including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia. Or securing with clips, complete all as specified and directed by the Engineer in Charge.
Mild steel bars (TMT bars) 8 to 10 mm dia as in stirrups cut to length, bent to shape required, including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia. Or securing with clips, complete all as specified and directed by the Engineer in Charge.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under reamed piles and mass concrete , complete all as specified and directed by Engineer-in-Charge.Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in slabs supported on wall beam and column in floor slabs and roofs landing deck slabs and in shelves, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix)using 20mm graded mechanically crushed stone aggregates as in beams, cantilevers, bressumers, lintels over 1.5 m span , complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in chajjas and the like, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in columns, pillars, piers, posts ans stuts , complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Applying three coat of white wash on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified and as directed by the Engineer-in-Charge.
Applying three coat of white wash on newly plastered or unplastered Ceiling surface including preparation of surfaces, complete all as specified and as directed by the Engineer-in-Charge.
Preparation of newly plastered or unplastered surfaces of walls by brooming down and priming plastered and other surfaces with cement paint primer ( before application of cement base paint) including two coats of cement base paint complete all as specified and directed by Engineer-in- Charge.
Use & waste of form work to soffits of suspended slab of concrete such as roof slabs, floor slabs, cover slab, shelve, landings and similar works n.exc 200 mm thick (horizontal or sloping); with rough finished surfaces of concrete flat surface, complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to sides of Square, rectangular or polygonal pillars, posts, struts, piers, columns and stanchions surfaces finished fair , complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders,bresumers, lntels, cantilevers, shelves including supports, overhangs, chajjas etc. also splays between floors and beams etc., surfaces finished fair in forms , complete all as specified and directed by the Engineer in Charge.
Use & waste of for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter etc for rough finished surfaces of concrete,complete all as specified and as directed by Engineer -in-Charge.
Use & waste of form work to chajjas and similar work for fair finished concrete surface , complete all as specified and directed by the Engineer in Charge.
Broken bricks for hardcore of gauge nexc 63 mm, deposited, spread and levelled in layers nexc 15 cm thick watered and rammed to true surface , complete all as specified and directed by Engineer-in-Charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bar, dovtailed or welded complete all as specified & directed
Sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and directed by Engineer-in- Charge.
Plain cement concrete 1:4:8, type D-2, using 40 mm graded mechanically crushed stone aggregates ,100 mm thick as in sub base to flooring etc complete all as specified and directed by the Engineer in Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates 75mm thick as in sub base to floor, complete all as specified and directed by Engineer-in-Charge.
Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, m-35 grade over and including 40mm thick sand layer including filled interstices in and complete all as specified and directed by Engineer-in- Charge. complete all as specified and directed by Engineer-in- Charge.
Plain cement concrete type C2 (1:3:6), using 40 mm graded crushed stone aggregate,75 mm thick , as in path /paving finished even and smooth wothout using extra cement ,complete all as specified and directed by the Engineer in Charge.
Plain cement concrete 1:2:4 type B1 , using 20 mm graded crushed stone aggregate, 40 mm thick in floor finishing cement concrete surface even and smooth without using extra cement as in floor and the like, complete all as specified and directed by Engineer-in-Charge.
Sand filling under floors or in foundations including watering and consolidation complete all as specificed and directed by Engineer-in-Charge.
M&L for 24 gauge wire netting with 12 mesh per 25mm fixed to all with necessary fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Water proofing treatment on roof surfaces to the following specification:- (a) 15mm thick screed plaster on RCC slab CM 1:4 with using in and including liquid water proofing compound @ 3% by weight of cement. (b) Applying oil bound bitumen primer @ 0.40 lit / Sqm of density 0.87 - 0.89 Kg/lit of 25º C after preparation of the surfaces. (c) Supply and laying 3mm thick APP water proofing membrane reinforced with non woven polyster matt laid using butane torch by torch on application with a side lap of 10cm and 15cm end lap weighing not less than 3.5 kg/sqm. (d) Providing 230 x 115 x 40mm thick machine pressed brick tiles with minimum thickness of joint (n.exc 3mm) and are throughly filled with water proof polymer based joint mortar , complete all as specified and directed by Engineer-in-Charge. (Note : The tiles shall be laid to the slop to avoid stagnation of water).
Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing ,complete all as specified and directed by Engineer-in- Charge.
Mild steel plaint sheet 1.25 mm thick as in hearths, covering to door shutter, covering to door chowkats (frames), chullah hoods, water tanks water troughs, ducts urinal troughs and funnels etc cut to size edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc, with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets etc as required complete all as specified and directed by Engineer-in-Charge.
Preparing new steel surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified and directed by Engineer-in-Charge.
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Flame proof LED tube light fittings with Flame Proof battern of capacity 28 watt (4feet) complete all as specified and directed by Engineer-in-Charge.
Flame proof metal body exhaust fan 300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing , complete all as specified and as directed by Engineer-in- Charge.
Suspended ceiling, comprising 12.5 mm thick reinforced gypsum plaster boards Conforming to IS-2095 , GI perimeter channels, intermdiate channels, etc. including finishing the exposed surfaces with Oil bound distemper two coats including dismantling of wall and ceiling boards (fiber, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets , complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) junction single, (single Tee) equal or unequal with access door complete all as specified and directed by Engineer-in- Charge.
S&F 75mm bore PVC (SWR) bend of any radius complete all as specified and directed by Engineer-in- Charge.
S&F powder coated aluminium sections (conforming to IS) window, ventilator three track (02 Nos shutter of glass & 01 No of SS jail shutter) shutter, aluminium section weighing 0.55 Kg/m including necessary joining, cleats, glazing clips rubber neoprene packing, handle 2 Nos in each shutter, hinges, anodised aluminium snap beading screw complete all as specified and directed by Engineer-in- Charge.
S&F in repair Powder coated Aluminium sections ( conforming to IS) door frames with double leaf shutters complete duly fitted with neosprene rubber beading,heat absorbing glass panes 4.8 mm nominal thickness, Alu anodised with rubber shoe floor door stoppers- 2 Nos , jointing cleats, glazing clips, designation No. 1 , universal type , Al die cast anodised Hydraulic door closers aluminium body -02 Nos , push plate- 2 Nos , standard lock- 1No., Aluminium hinges 100 mm long butt hinges, 8Nos , Aluminium anodised handle circular type of 100 mm dia-04 Nos , Aluminium anodised tower bolts 200 mm long -04 Nos , complete all as specified and directed by Engineer-in- Charge.
S&F Powder coated anodised Aluminium sections ( conforming to IS) door frames with single leaf shutter complete duly fitted with neosprene rubber beading,heat absorbing glass panes 4.8 mm nominal thickness, floor door stoppers, , jointing cleats, glazing clips, Al die cast anodised Hydraulic door closers aluminium body designation No. 3 , universal type , push plate, standard lock, Aluminium hinges 100 mm long butt hinges 4Nos , Aluminium anodised handle circular type of 100 mm dia-02 Nos per shutter, Aluminium anodised tower bolts 200 mm long -02 Nos per shutter complete all as specified and directed by Engineer-in- Charge.
M&L 60 mm thick PCC intrelocking tiles (rubber laminated finish ) of size and shape as approved , laid dry on sand not less than 40 mm thick, interstices filled in floors/ pathway complete all as specified and directed by Engineer-in- Charge.(Sand cushion shall not be measured and paid seperately)
Plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof kerbs/padding or similar works or mud stops rounded or chamfered on edges angles ,complete all as specified and directed by the Engineer in Charge.
Demolition of floor hearth or wall tiling including cement mortar bedding (But not backing) removeing serviceable tiles to store and rubbishoff the premishes complete all as specified and directed by Engineer-in- Charge.
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick screed in CM 1:3 complete all as specified and directed by Engineer-in- Charge. (Note : Screed bed will not be measured and paid separately)
Grinding of old kota stone flooring upto mirror finish level including polisihig etc complete all as specified and directed by Engineer-in- Charge.
Aluminium Anodised aluminium partition with 12mm thick prelaminated particle board at bottom panel and 5.5.mm thick glass on top panel including glazing clip and neosprene rubber beading as in repair , complete all as specified and directed by Engineer -in-charge.Note: Rate of Glass and 12 mm thick prelaminated particle board shall be included in the rate quoted by the contractor against above item.
M&L for extrior grade wall tiles in vertical surfaces 143.5 x 450 x 7-10 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick screed in CM 1:3 complete all as specified and directed by Engineer-in-Charge. (Note:- Screed bed will not be measured and paid separately)
M&L for extrior grade floor tiles in horizental surfaces size between 0.09 - 0.36 sqm area and 20-25 mm thick set and jointeed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 20 mm thick screed in CM 1:4 complete all as specified and directed by Engineer-in-Charge. (Note:- Screed bed will not be measured and paid separately)
Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and directed by Engineer-in- Charge.
Point wiring for one socket outlet point 5 amps on independent board controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
All as per item no 70 hereinbefore but one socket outlet point on same baord with other switches with 1.5 sq mm single core multistranded PVC insulated FRLS cable including 1.5 sq mm single core multi stranded copper cable used as continuous earth wire,complete all as specified and as directed by Engineer-in- Charge.
Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge.
S&F Moduler switch 10 Amp, SP, one way 220 Volts AC, square white mechanisms and ISI marking, complete all as specified and as directed by Engineer-in- Charge.
S&F Moduler switch 1 way 16A, 1 modules square white mechanisms and ISI marking, complete all as specified and as directed by Engineer-in- Charge.
S&F Moduler socket shuttered 10 Amps, 3 Pin Universal India -2 module, complete all as specified and as directed by Engineer-in- Charge.
S&F Moduler switch 16 Amp, SP, one way 220 Volts AC, square white mechanisms and ISI marking, complete all as specified and as directed by Engineer-in- Charge.
Ceiling rose, Pilot 3 Plate ceiling rose 6A ,complete all as specified and as directed by Engineer-in- Charge.
Distribution box epoxy powder coated ,SPN 8 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps B or C series, 240 Volts to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs complete all as specified and directed by Engineer-in- Charge.
MCBs SPN/ Isolator, 40 Amps, 240 Volts to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs complete all as specified and directed by Engineer-in- Charge.
Sub main wiring (concealed type ) with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC conduit & 1 run of 4 Sqmm cable will be measured as single run.(ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring (concealed type ) with two single core 10 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 10Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface complete all as specified and directed by Engineer-in-Charge.Note : (i) 2 run of 10 Sqmm ,1 run of PVC conduit & 1 run of 10 Sqmm cable will be measured as single run.(ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Recess LED llight fittings of size 2X2 42 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept complete all as specified and as directed by Engineer-in- Charge.
Lamp holder batten / anguler type , PVC/polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing LED battern with LED tube light rod 30 watt 4 feet retro type complete all as specified and directed by Engineer-in-Charge.
Ceiling fan 1200 mm sweep, BEE 5 star rated AC 230 volts single phase including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing, complete all as specified and as directed by Engineer-in- Charge.
M R CONSTRUCTION
Powertronix
M/s Vimal Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .