Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.2 LAccepted-AOC AT P O RAHAM P S TANDWA PIN 825321 | RAHAM | CHATRA | JHARKHAND | 825321 | L-1 | Accepted-AOC Work Awarded to L1 bidder. | |
| 2 | Rejected-Technical 51 RAHAM RAHAM TANDWA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | - | Rejected-Technical L2 Bidder. Documents of L2 bidder not scrutinized, as bid of L1 bidder found acceptable technically and financially. |
Tender Value
₹3.0 L
EMD Value
₹3,800
Closing Date
16 Mar 2024, 5:00 pmClosed
Project Engineer (EnM), Ashok
Ashok OCP, Piparwar Area Chatra, Jharkhand-829201
(A) Repairing of wiring with electrical accessories of 02 nos. of Barrack kitchen and Toilets of Home Guards situated in Explosive Magazine premises under Ashok OCP (B) Providing suitable earth-pit for Rajdhar Rail WB for safety of electrical app
2024_CCL_303298_1
PO(AK)/PE(EnM)/e-NIT/23-24/119
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Ashok OCP, Piparwar Area Chatra, Jharkhand-829201
2 documents required · 2 mandatory
₹3,800
29 Apr 2024
1 Mar 2024
18 Mar 2024
2 Mar 2024
16 Mar 2024
2 Mar 2024
2 Mar 2024 - 9 Mar 2024
Amount
Part A:- Re- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm. FRLS PVC insulated copper single core cable in surface/ recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. /P.V.C. box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sq. mm. + 1x1.5 sq. mm. earth wire.
Wiring for light / power plug with 2x4 sq. mm. FRLS PVC insulated copper single core cable in surface/recessed medium class PVC conduit alongwith1 No 4 sq. mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing metal box of following sizes (nominal size- 100 mm X 100 mm X 60 mm)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
2+2 way, SPN, single door MCB DB
2+4 way, SPN, single door MCB DB
Earthing with copper earth plate 600mmx600mmx6mm thick including accessories and providing masonry enclosure and watering pipe with charcoal/salt etc as required. (01 no for eah barrack each)
Supplying and laying 25mmx5mm copper strip at 0.5 mtr below ground as strip electrode including connection, termination with GI nut bolt, spring, washer etc
For service connection:Supplying and drawing 2x6sqmm sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/recessed steel/PVC conduit as required.
Providing and fixing of 3 pole MCCB, 125A, 16KA
Fixing Charges @ 10% on item 8,9, 13
Part B:- Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
PART C:- Point wiring in PVC conduit with piano type switch: wiring for light point/fan point/exhaust fan point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit phenolic laminated sheet suitable size MS box & earthing the point with 1.5 sqmm FRLS PVC insulated copper
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sq. mm. + 1x1.5 sq. mm. earth wire.
Wiring for light / power plug with 2x4 sq. mm. FRLS PVC insulated copper single core cable in surface/recessed medium class PVC conduit alongwith1 No 4 sq. mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
(Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.) (a) 15/16 amp switch.
(b)5/6 amp switch
(Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.) (a)6 pin 15/16 amp socket outlet.
(b)3 pin 5/6 amp socket outlet
Numbering of exhaust fan/fan etc
For service connection: Supplying and drawing 2X6 sqmm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/pvc conduit as required
Total impact of GST for the purpose of CTC
M/S BABA & CO
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .