Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹84.1 L
EMD Value
₹1.7 L
Closing Date
12 Aug 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CM (Contracts ) NAGPUR
POWERGRID WR1 RHQ NAGPUR
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
WR-I/CandM/2022/NIT-27/Package-A/Rfx-5002002338
Open
Civil - All
Works
Raipur
₹2,500
₹1.7 L
8 Jul 2022
8 Jul 2022
12 Aug 2022
8 Jul 2022
7 Aug 2022
8 Jul 2022
Name of Package : Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII
Package No : CD01R
Specification No. : CC-CS/236-NR1/CD-1764/3/G7
Completion Period 18 Months
: Attachments : General guidelines for filling up the Attachments Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(QR), 4, 5, 6, 7, 8, Attach-9, 9(IP), 10, 11, 12, 13,14 and Bid Form for 1st Envelope are included here. .
3 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Proprietorship 1
Private Limited Company 2
Enter following details of the bidder Public Limited Company
Specify type of Bidder [Select from drop down menu]
Address of Registered Office
Specification No. :CC-CS/236-NR1/CD-1764/3/G7 Attachment-3(JV) CD01R CD01R
Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-3(QR)
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Qualifying Requirement Data
Bidder’s Name and Address (Bidder) :
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Dear Ladies and/or Gentlemen,
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & additional information required as per the Bidding Documents, we furnish herewith our QR data/details/documents etc., alongwith other information, as follows (The QR stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
We are furnishing the details/document in support of qualifying requirement for the subject package(s) as uploded along with bid.
A Technical Experience
A Bidder is Manufacturer
Authorised Dealer/Sub dealer
Name of Manufacturer Authorised Representative
Authorization of Manufacturer Submitted
Please submit relevent document Certificate of Authorized Dealership Submitted
B Technical Experience Authorization of Manufacturer Submitted
1 Make of 400 kV or higher voltage class outdoor switchyard equipment(s) Offered by the Bidder
Name of Manufacturer
2 Name of the Client
3 Address of Client
4 Contact Details of Client YES
5 Whether Client is having 400 kV or above Transmission System NO
Client should have 400 kV or above Transmission system
5 Documentary Evidence for above Uploaded Completion Certificate from Client
Please upload the Documentary Evidence Performance Report from Client
6 Purchase Order Details Acceptance of Final Bill by Client
Reference No. Certificate from CA
Date (dd-mm-yyyy) Any Other (Please Specify)
7 Make of Equipments supplied
7 Date of work done for Supply & installation of 400Kv or higher voltage class outdoor switchyard equipment(s) (dd-mm-yyyy)
8 Proof of work done pertains to Supply & Installation of 400Kv or higher voltage class outdoor switchyard equipment(s) Uploaded Performance Report from Client
Please upload Proof of work done Any Other (Please Specify)
9 Document submitted as Proof of work done Specify document submitted as proof of Satisfactory Operation
10 Details of above Document
Date (dd-mm-yyyy)
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client
5 Work Order Details
6 Copy of Work order uploaded
7 Date of Completion of Work
8 Completed Amount of work (Rs)
please ent=IF(C41>=H49,IF(C74>=H49,"",IF(C74>=H50,"please enter 01 more work of 14 lakh and above","work insufficient")))er 01 more work of 14 lakh and above
7 Document submitted as Proof of Completion
8 Details of Document for Proof of Completion
11 Proof of Completion Uploaded
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client
5 Work Order Details
6 Copy of Work order uploaded
7 Date of Completion of Work
8 Completed Amount of work (Rs)
please ent=IF(C41>=H49,IF(C74>=H49,"",IF(C74>=H50,"please enter 01 more work of 14 lakh and above","work insufficient")))er 01 more work of 14 lakh and above
7 Document submitted as Proof of Completion
8 Details of Document for Proof of Completion
11 Proof of Completion Uploaded
B Financial Requirement - Performance Report from Client
Acceptance of Final Bill by Client
Certificate from CA
Any Other (Please Specify)
Sr. No. Financial Year Turnover (in Rs. Lakh) Copy of Balance Sheet & P/L Account Uploaded
Average Turnover for Best Three Years
C General Requirements
ART-B: GENERAL (a) Following document shall be submitted by the bidder : i) Copy of PAN Card ii) Copy of Partnership Deed/ Affidavit for Proprietorship/ Company MoA & AoA or Certificate of Incorporation, as applicable iii) Copy of GSTIN certificate (b) POWERGRID, reserves the right to relax/waive of minor deviations with respect to QR as stipulated above, the decision of POWERGRID in this regard shall be final & binding on bidders. (c) POWERGRID reserves right to assess the capacity and capability of the bidder to successfully execute the contract, if felt necessary. This assessment may inter-alia include (i) document verification (ii) past experience and performance (iii) customer feedback (iv) bankers feedback (v) Litigation History YES
1 Copy of PAN Card Uploaded NO
Please upload Copy of PAN Card
2 Copy of Electrical contractor licence Uploaded
2 Status of the Bidder
3 Copy of GSTIN Registration Number
4 MOA & AOA/ Certificate of Incorporation Uploaded
5 Copy of Electrical Contractor License NO
Please upload Copy of Relavent document
Date : Printed Name :
Place : Designation :
Private Limited Company
Public Limited Company
Affidavit of Proprietorship Uploaded
Parnership Deed Uploaded
MOA & AOA/ Certificate of Incorporation Uploaded
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-4
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Form of Certificate of Origin and Eligibility
Bidder’s Name and Address (Bidder) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name :
Place : Designation :
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :CC-CS/236-NR1/CD-1764/3/G7 Attachment-4(A) CD01R
Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
S.No. For Equipment Item Description Unit Quantity
Date : Printed Name :
Place : Designation :
Specification No. :CC-CS/236-NR1/CD-1764/3/G7 Attachment-4(B) CD01R
Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-4A
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Commentary on the Employer’s Technical Specifications
Bidder’s Name and Address (Bidder) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Make of the Equipment Offered
Model of the Equipment Offered
The Bidder should comply with all the Technical Parameters mentioned in "Technical Specifications (Volume-II) of the bid documents and scanned copy of the same duly signed and stamped on all pages shall be uploaded by the bidder along with the bid.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-5
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Bidder’s Name and Address (Bidder) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-5
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No. :CC-CS/236-NR1/CD-1764/3/G7 Attachment-8 CD01R
Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII
(Manufacturer's Authorization Form)
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001 Name of Manufecture Name/Description of Goods Factory Address Name & Address of Bidder package name alongwith project name
…(insert name of the Manufacturer) .. …(insert name and/or description of the goods) … ..(insert address of factory) .. Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII
WE …(insert name of the Manufacturer) .. who are established and reputable manufacturers of …(insert name and/or description of the goods) …. having production facilities at ..(insert address of factory) .., , , do hereby authorize , , , (hereinafter, the “Bidder”) to submit a bid, and subsequently negotiate and sign the Contract with you against IFB for Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII including the above plant & equipment or other goods produced by us.
WE …(insert name of the Manufacturer) .. who are established and reputable manufacturers of …(insert name and/or description of the goods) …. having production facilities at We hereby extend our full guarantee and warranty for the above specified goods offered supporting the supply by the Bidder against these Bidding Documents, and duly authorize said Bidder to act on our behalf in fulfilling these guarantee and warranty obligations.
We hereby extend our full guarantee and warranty for the above specified goods offered supporting the supply by the Bidder against these Bidding Documents, and duly authorize said Bidder to act on our behalf in fulfilling these guarantee and warranty obligations. We also hereby declare that we and have entered into a formal relationship in which, during the duration of the Contract (including warranty/defects liability). We, the Manufacturer or Producer, will make our technical and engineering staff fully available to the technical and engineering staff of the successful Bidder to assist that Bidder, on a reasonable and best effort basis, in the performance of all its obligations to the Purchaser under the Contract. ..(insert address of factory) .., , , do hereby authorize , , , (hereinafter, the “Bidder”) We also hereby declare that we and have entered into a formal relationship in which, during the duration of the Contract (including warranty/defects liability).
For and on behalf of the …(insert name of the Manufacturer) .. to submit a bid, and subsequently negotiate and sign the Contract with you against IFB for Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII including the above plant & equipment or other goods produced by us. We, the Manufacturer or Producer, will make our technical and engineering staff fully available to the technical and engineering staff of the successful Bidder to assist that Bidder, on a reasonable and best effort basis, in the performance of all its obligations to the Purchaser under the Contract.
In the capacity of
Date : Printed Name :
Place : Designation :
Note :1 The letter of Undertaking should be on the letterhead of the Manufacturer and should be signed by a person competent and having Power of Attorney to legally bind the Manufacturer. It shall be included by the bidder in its bid.
2 Above undertaking shall be registered or notarized so as to be legally enforceable.
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-6
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Guarantee Declaration
Bidder’s Name and Address (Bidder) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
We conform that the material offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-7
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Information regarding Ex-employees of POWERGRID in our Organisation
Bidder’s Name and Address (Bidder) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority.
Accordingle, We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
* In case the date of joining in the bidder's organization of such ex-employee is within 1 year from the date of retirement/ resignation from POWERGRID, No objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate / approval of the Competent Authority, as required, we understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard.
We further declare that any misrepresentation or submission of false / forged documents / information in this regard shall be dealt with as per the provisions of the Integrity Pact and / or the Bidding Documents and / or POWERGRID’s policy and procedures.
Date : Printed Name :
Place : Designation :
1) “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com.
2) The information in similar format should be furnished for each partner of joint venture in case of joint venture bid.
3) In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-8
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Declaration regarding Social Accountability
Bidder’s Name and Address (Bidder) : To:
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-9
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Bidder’s Name and Address (Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Integrity Pact is annexed herewith this volume
Integrity Pact is NOT Applicable
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (n).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
Preamble POWERGRID intends to award, under laid-down organisational procedures, contract(s) for
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID under Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
(2) The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation : …….. …… ………. …
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-10
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise)
Bidder’s Name and Address (Bidder) : To:
Power Grid Corporation of India Ltd.,
Name : Western Region -I Headquarters
Address : Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
I. We have read the provision in the Bidding Documents regarding furnishing the option for advance payment.
Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents,
we hereby confirm to opt the following:
Interest Bearing Initial Advance: Supply Portion
(Select from drop down list)
We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3 (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3 (b) Are you a MSE owned by SC/ST* enterpreuners in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order
3 (c) If 3(b) is 'Yes', please mention whether you are (Proprietory MSE/ Partenership MSE/ Private Limited Company) owned by SC/ST Enterpreneurs Yes Proprietory MSE
3 (d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order (Indicate Yes/No)
4. Permanent Account (PAN) No. No Partenership MSE
5 Work Contract Tax No. Private Limited Company
7 PF Registration No. of the Company
8 PF Regional Office covered (with Address)
9 Name of Contact Person
10 Telephone No(s)
11 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Saving Account
12 9 digit MICR code printed at bottom in middle, next to cheque no.
13 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
* The definition of MSEs owned by SC/ST is as given under:
a. In case of Proprietory MSE, proprietor(s) shall be SC/ST.
b. In case of Partenership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited Companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-11
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Additional Information
Bidder’s Name and Address (Bidder) : To:
Power Grid Corporation of India Ltd.,
Name : Western Region -I Headquarters
Address : Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
In support of the additional information required as per ITB Sub-Clause 9.3(k) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
0.0 The Bidder shall furnish
0.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(k)(i)]
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
0.0 OTHER INFORMATION
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-12
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Bidder’s Name and Address (Bidder) : To:
Power Grid Corporation of India Ltd.,
Name : Western Region -I Headquarters
Address : Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
I hereby declare that the documents submitted/uploaded by us to demonstrate the compliance to the specified Qualifying Requirement for this package are true, authentic and correct.
Further, we hereby confirm that except as mentioned in the Attachment -5 (Deviations) hereof , forming part of our First Envelope:
(i) there are no discrepencies/inconsistencies and deviations/omissions/reservations to the Bidding Documents, in the Second Envelope bid;
We also confirm that in case any discrepencies/inconsitencies and deviations/omissions/reservations, as referred to in para (i) and (ii) above, is observed in the Second Envelope, the same shall be deemed as withdrawn/rectified without any finacial implication, whatsoever to POWERGRID. However, in case of any artithmetical errors, the same shall be governed as per the provisions of ITB Sub-clause 27.2 read in conjuction with BDS.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-13
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Bidder) : To:
Power Grid Corporation of India Ltd.,
Name : Western Region -I Headquarters
Address : Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us
We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):"
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-14
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(Format for Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, 2017 and MoP Order December 2018, if applicable, to be provided on a non-judicial stamp paper of Rs. 100/-)
Bidder’s Name and Address (Bidder) : To:
Power Grid Corporation of India Ltd.,
Name : Western Region -I Headquarters
Address : Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Format for Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, 2017 if applicable, to be provided on a non-judicial stamp paper of Rs. 100/-. Date: -------------- I ________S/o, D/o, W/o, _____________________Resident of_________________________________________________________ hereby solemnly affirm and declare as under: That I will agree to abide by the terms and conditions of the Public Procurement (Preference to Make in India) Order, 2017 (hereinafter PPP-MII order) of Government of India issued vide Notification No:P-45021/2/2017 -BE-II dated 15/06/2017, its revision dated 28/05/2018, 'Public procurement (Preference to make in India) to provide for purchase preference (linked with local contenet) in respect of Transmission Power Sector Order dtd. 20.12.2018 issued by Ministry of Power (Hereinafter MoP Order December 2018) and any subsequent modifications/Amendments, if any and That the information furnished hereinafter is correct to the best of my knowledge and belief and I undertake to produce relevant records before the procuring entity/POWERGRID or any other Government authority for the purpose of assessing the local content of goods/services/works supplied by me for ……………………………………. (Enter the name of the package). That the local content for all inputs which constitute the said goods/services/works has been verified by me and I am responsible for the correctness of the claims made therein. That the goods/services/works supplied by me for ……………………………………. (Enter the name of the package) meet the ‘Minimum Local Content ‘as defined in the PPP-MII order and MoP Order December 2018 for FY 2018-19 and value of Minimum Local Contenet (In %) to be achieved 'Over the next five years in phased manner' as specified in the MoP Order December 2018. That the value addition for the purpose of meeting the ‘Minimum Local Content ‘has been made by me at ……………………… (Enter the details of the location(s) at which value addition is made).
That in the event of the local content of the goods/services/works mentioned herein is found to be incorrect and not meeting the prescribed Minimum Local Content criteria, based on the assessment of procuring agency (ies)/POWERGRID/Government Authorities for the purpose of assessing the local content, action shall be taken against me in line with the PPP-MII order, MoP Order December 2018 and provisions of the Integrity pact/ Bidding Documents. I agree to maintain the following information in the Company's record for a period of 8 years and shall make this available for verification to any statutory authority. i Name and details of the Local Supplier (Registered Office, Manufacturing unit location, nature of legal entity) ii. Date on which this certificate is issued iii. Goods/services/works for which the certificate is produced iv. Procuring entity to whom the certificate is furnished v. Percentage of local content claimed and whether it meets the Minimum Local Content prescribed vi. Name and contact details of the unit of the Local Supplier (s) vii. Sale Price of the product viii Ex-Factory Price of the product ix. Freight, insurance and handling x. Total Bill of Material
xi List and total cost value of input used to manufacture the Goods/to provide services/in construction of works xii. List and total cost of input which are domestically sourced. Value addition certificates from suppliers, if the input is not in-house to eb attached xiii. List and cost of inputs which are imported, directly or indirectly For and on behalf of……………………………………………… (Name of firm/entity) Authorized signatory (To be duly authorized by the Board of Directors) <Insert Name, Designation and Contact No.>
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-15
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(Certificate from statutory auditor or cost auditor of the company )
(NOT APPLICABLE)
Bidder’s Name and Address (Bidder) : To:
Power Grid Corporation of India Ltd.,
Name : Western Region -I Headquarters
Address : Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable [to be submitted on the letter head of the issuer.] Dear Sir, We have read and understood the provisions of “Public Procurement (Preference to Make in India) Order, 2017” dated 15/06/2017, its revision dated 28/05/2018 and any subsequent modifications/Amendments, if any [hereinafter, “PPP-MII Order”] issued by Department of Industrial Policy and Promotion (DIPP), Ministry of Commerce and Industry, Government of India. In line with the provisions of the PPP-MII Order, M/s. ………[Enter the name of the Bidder] [hereinafter, “Local Supplier”] have submitted an Affidavit of self-certification to M/s. Power Grid Corporation of India Limited [hereinafter, POWERGRID] regarding Local Content in Goods/Services/Works to be supplied by the Local Supplier for ……………… [Enter the name of the package], wherein they have agreed to abide by the terms and conditions of the PPP-MII Order.
Further, in line with the PPP-MII Order, the statutory auditor or cost auditor of the company (in the case of companies) or a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) shall provide a certificate giving the percentage of Local Content in the Goods/Service/Works to be supplied by the Local Supplier for ……………… [Enter the name of the package]. Accordingly, we, the Statutory Auditor(s) / Cost auditor (applicable in the case of companies) of the Local Supplier / a practicing cost accountant or practicing chartered accountant (applicable in respect of suppliers other than companies), certify that the Local Content as defined under the PPP-MII, in the Goods/Service/Works to be supplied by the Local Supplier for ……………… [Enter the name of the package] is ……….. percentage [specify the percentage of Local content ]. For and on behalf of, Date: <<Statutory Auditor’s/ Cost auditor’s/ Cost accountant’s/ Chartered accountant’s attestation>> Firm Reg No. Membership No. Note: This is a guiding format. In case the bidder submits the certificate in a format different from the above, the same may be considered provided it meets the intent and purpose, as may be ascertained by POWERGRID.
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Attachment-16
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA)
(NOT APPLICABLE)
Bidder’s Name and Address (Bidder) : To:
Power Grid Corporation of India Ltd.,
Name : Western Region -I Headquarters
Address : Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Date : Printed Name :
Place : Designation :
Specification No.:WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th 6 June
7 seven 7 th 7 July
To: 8 eight 8 th 8 August
Power Grid Corporation of India Ltd., 9 nine 9 th 9 September
Western Region -I Headquarters 10 ten 10 th 10 October
Sampriti Nagar, Nari Ring Road 11 eleven 11 th 11 November
PO: Uppalwadi, Nagpur (MS) -440026 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
0.0 Having examined the Bidding Documents, including Amendment Nos. NIL dated NA the receipt of which is hereby acknowledged, we the undersigned, offer to execute the work under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). NIL NA the receipt of which is hereby acknowledged, we the undersigned, offer to execute the work under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
0.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(b) Attachment 2 A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Please note that if amount of bid security is less than Rs. 3,31,000/-, your bid may be rejected Bank Guarantee (0) 21 st
(c) Attachment 3 The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). 22 th
Applicable 23 th
Not Applicable 24 th
(d) Attachment 4 The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. 25 th
(e) Attachment 5 The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 26 th
(f) Attachment 6 Guarantee Declaration 27 th
(g) Attachment 7 Information regarding ex-employees of Employer in Bidder’s firm 28 th
(h) Attachment 8 Declaration regarding Social Accountability 29 th
(i) Attachment 9 Integrity Pact :NA 30 th
(j) Attachment 10 Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise) 31 st
(k) Attachment 11 Additional Information
(l) Attachment 12 Declaration
(m) Attachment 13 Declaration for tax exemptions, reductions, allowances or benefits
(n) Attachment 14 Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order,
(o) Attachment 15 Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable----NOT APPLICABLE
(p) Attachment 16 eRA---NOT APPLICABLE
0.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
0.0 We declare that as specified in Clause 11.10, Section –II:ITB, Vol.-I of the Bidding Documents, the RATES of all the Goods to be supplied under this contract shall remain FIRM during the currency of the contract and no price adjustment shall be applicable..
0.0 Construction of the Contract
0.9 We declare that we have studied relevant clausesrelating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us the Contracts covering all goods and related services.
0.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 53 Terms of Payment
(c) GCC 8.0 Performance Security
(d) GCC 6.0 Taxes and Duties
(e) GCC 11.0 Completion Time Guarantee
(f) GCC 36 Defect Liability
(g) GCC 16.5 Patent Indemnity
(h) GCC 56 Settlement of Disputes
(i) GCC 58 Arbitration
0.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification/Letter of Award to us, and to achieve the completion of works and related services within the time stated in the Bidding Documents.
0.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
0.0 We agree to abide by this bid for a period of 150 days from the date initially stipulated for opening of bids (first envelope) as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period
0.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
0.0 We understand that you are not bound to accept the lowest or any bid you may receive.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
ElectronicForms™
View - Template of ElectronicForm™
To close this Screen, click on the [Close] button located on the bar above, or at the bottom of the Screen
Template of ElectronicForm™
Relevant Bid-Part Techical
ElectronicForm™ Template ID 7PG-2010-FT000010
Template Reference TECHNO-COMMERICIAL (First Envelope)
Template Description Tower Package CD01R Specification No. : CC-CS/236-NR1/CD-1764/3/G7
Conductor Pkg. P214-CD01R for supply of 134 km of ACSR Bersimis conductor and 3265 km of ACSR Moose conductor associated with Northern Region System Strengthening Scheme – XXVIII
Section-2 (Outline of Requirements)
* 1 Integrity Pact Details
Submitted (Doc. Code No. DC-9008-April-2009-Rev-0) Yes
* 2 BID SECURITY DETAILS
2 (a) Submitted Yes
* 2 (b) Bid Security No.
* 2 (c) Issued by (Name of Bank)
* 2 (d) Bid Security Amount
* 2 (e) Valid upto
* 1. AUTHORIZED SIGNATORY (Sole Bidder / Lead Partner of JV)
1 (b) Designation
2. AUTHORIZED SIGNATORY (Other Partner of JV)
(If Bidder is JV)
2 (b) Designation
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
23 twenty three
27 twenty seven
28 twenty eight
33 thirty three
37 thirty seven
38 thirty eight
73 seventy three
74 seventy four
75 seventy five
77 seventy seven
78 seventy eight
79 seventy nine
83 eighty three
87 eighty seven
88 eighty eight
93 ninety three
97 ninety seven
98 ninety eight
Enter basic data here
[Fill up data only in the relevent open area]
1 Name of Package
2 Specification No.
4 Item Description ACSR ZEBRA Conductor
5 Quantity in km. 6615
6 Type Tests Tests to be conducted Nos of tests
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3 & Discount.
2 All the cells in Sch-5 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 Based on the data filled in the respective schedules, e-Form is generated automatically. A print out of e-Form may be taken and the data may be filled in the electronic form of the tender provided on the portal.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Manufacturer 1
Authorized Dealer/ Sub-dealer of Manufacturer 2
Enter following details of the bidder Authorized Representative of Manufacturer
Specify type of Bidder [Select from drop down menu]
Name of Manufacturer
PhoneNo/ Mobile No.
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(SCHEDULE OF RATES AND PRICES : - Scheduled Items )
Bidder’s Name and Address To:
Bidder as Contract & Material
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
All values are in Indian Rupees.
SI. No. ITEM NO. Item Description Unit Qty. Rate Amount
Schedule Items as Per DSR-2021
Part-A -Schedule Items (CIVIL PART)
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
2.6.1 All kinds of soil Cum 30 Included
2 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. Cum 175
3 2.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
2.10.1 All kinds of soil.
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. meter 50 Included
4 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum 110 Included
5 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. Cum 27 Included
2.26.1 All kinds of Soil
6 2.34 Supplying chemical emulsion in sealed containers including delivery as specified.
2.34.1 Chlorpyriphos - Lindane emulsifiable concentrate of 20% Litres 50 Included
7 2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
2.35.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration meter 350 Included
GROUP - CONCRETE WORK -
8 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.5 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Cu.m. 3.5 Included
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) Cu.m. 29 Included
9 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :
4.3.1 Foundations, footings, bases for columns . Sq.m. 22 Included
10 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. sqm 65 Included
GROUP - RCC WORK
11 0.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) Cu.m. 66 Included
12 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) Cu.m. 8 Included
13 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Cu.m. 55 Included
14 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sq.m. 17 Included
5.9.3 Suspended floors, roofs, landings, balconies and access platform Sq.m. 155 Included
5.9.5 Lintels, beams, plinth beams, girders, bressumers & cantilevers Sq.m. 245 Included
5.9.6 Columns, pillars, piers abutments posts & struts Sq.m. 90 Included
5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like Sq.m. 10 Included
5.9.16 Edges of slabs and breaks in floors and walls
5.9.16.1 Under 20 cm wide meter 55 Included
5.9.19 Weather shade, chajjas, corbels etc. including edges. Sq.m. 10 Included
15 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kilogram 2540 Included
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kilogram 7900 Included
16 5.3 Add - Deduct for plaster drip course-groove in plastered surface or moulding to RCC projections. Mtr. 20 Included
17 5.47 Providing and fixing in position factory made precast RCC M-40 doors and windows frames having excellent smooth finish as per IS: 6523 with reinforcement of 3 Nos, 6 mm dia main bars tied with 3 mm M.S stirrups placed @ 200 mm C/C and 6 numbers high strength polymer blocks of required size for fixing hinges including providing 6 no specially designed M.S. galvanised sleeves for accomodating 6 mm dia fully threaded bolts for fixing hold fast on vertical members, providing suitable arrangement for recieving sliding door bolts and tower bolt etc all complete, as per the direction of Engineer in charge. (The cost of hold fast and cc block of 1:3:6 mix is also included in the item.) The frame shall be measured in running meter correct to two places of decimal.
5.47.2 Door frame 100 mmx 60 mm metre 28 Included
18 6.15 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. Sq.m. 10 Included
GROUP MARBLE WORK - GRANITE WORK
19 8.2 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
8.2.2 Granite of any colour and shade
8.2.2.2 Area of slab over 0.50 Sq. m. Sq.m. 22 Included
20 8.3 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
8.3.2 Granite work meter 10 Included
21 8.1 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter andembedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade sqm 3 Included
22 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Sq.m. 85 Included
23 9.96 Providing and fixing aluminium sliding door bolts ISI marked anodised ,anodic coating not less than grade AC 10 as per IS-1868, transparent or dyed to required colour or shade with nuts and screws etc. complete:
9.96.1 300 x 16 mm Each 5 Included
24 9.21 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :
9.21.1 35 mm thick including ISI marked Stainless steel butt hinges with necessary screws. sqm 12 Included
25 9.97 Providing and fixing aluminium tower bolts ISI marked anodised ,anodic coating not less than grade AC 10 as per IS-1868, transparent or dyed to required colour or shade with necessary screws etc. complete:
9.97.2 250 X 10 mm Each 45 Included
26 9.1 Providing and fixing aluminium handles ISI marked anodised anodic coating not less than grade AC 10 as per IS-1868, transparent or dyed to required colour or shade with necessary screws etc. complete.
9.100.1 125 mm- for Doors Each 30 Included
9.100.2 100 mm- for Doors Each 15 Included
27 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper Each 7
28 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. Each 3 Included
29 10.25 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bars, ladders, railings, brackets, gates and similar works. Kgs. 230 Included
GROUP - FLOORING WORK
30 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
11.26.1 25 mm thick. sqm 143 Included
31 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. sqm 18 Included
32 11.31 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. metre 6 Included
33 11.32 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre sqm 10 Included
11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. sqm 125 Included
34 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
11.41.4 Size of Tile 1000x1000 mm Sq.m. 125 Included
35 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
11.46.4 Size of Tile 1000x1000 mm Sq.m. 20 Included
36 11.49 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
11.49.4 Size of tile 1000 x 1000mm sqm 50 Included
37 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red Sq.m. 145 Included
GROUP - ROOFING WORK
38 12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
12.21.1 In 75x75 mm deep chase metre 30 Included
39 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. each 6 Included
40 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.
12.41.2 110 mm diameter mtr 25 Included
41 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
12.42.1 Coupler
12.42.1.2 110 mm each 14 Included
12.42.5.2 110 mm bend Each 7 Included
42 12.42.6 Shoe ,Plain,
12.42.6.2 110 mm Each 7 Included
43 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
12.43.2 110 mm Each 14 Included
44 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. Each 7 Included
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
45 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) Sqm 73.1 Included
GROUP - FINISHING WORK
46 13.1 12 mm cement plaster of mix
13.1.2 1:6 (1 cement: 6 fine sand) Sq.m. 305 Included
47 13.2 15 mm cement plaster on rough side of single or half brick masonry wall of mix:
13.2.2 1:6 (1 cement: 6 fine sand) Sq.m. 360 Included
13.16.1 6mm cement plaster to ceiling of mix1:3 (1 Cement:3 Fine sand) Sq.m. 150 Included
48 13.19 Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.
13.19.1 Ordinary cement finish using ordinary cement sqm 20 Included
49 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. Per bag of 50 kg cement used in the mix 20 Included
50 13.26 Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete Sq.m. 260 Included
51 13.42 Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
13.42.1 Two or more coats on new work Sq.m. 975 Included
52 13.43 Applying one coat of cement primer of approved brand and manufacture on wall surfcae
13.43.1 Water thinnable cement primer. Sq.m. 1495 Included
53 13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
13.48A.1 New work (Two or more coats applied @ 1.43 litre/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. Sq.m. 420 Included
54 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. Sq.m. 520 Included
55 13.8 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sq.m. 200 Included
56 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. Cum 17 Included
57 15.7 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
15.7.4 In cement mortar Cum 15 Included
58 15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
15.12.1 Of area 3 sq. metres and below each 5 Included
15.12.2 Of area beyond 3 sq. metres each 2 Included
59 15.23 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
15.23.1 For thickness of tiles 10 mm to 25 mm Sq.m. 100 Included
60 15.28 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
15.28.1 G.S. Sheet Sqm 250 Included
61 16.68 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. Sqm 62 Included
GROUP - SANITARY ITEMS
62 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
17.7.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap Each 2 Included
63 17.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
17.10.1 Kitchen sink with drain board
17.10.1.1 510x1040 mm bowl depth 250 mm Each 3 Included
64 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.28.1 Semi rigid pipe
17.28.1.1 32 mm dia. Each 10 Included
65 17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
17.32.4 Rectangular shape 1500x450 mm Each 6 Included
66 17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. Each 4 Included
17.34 Providing and fixing toilet paper holder :
17.34.1 C.P. brass Each 4 Included
67 17.56 Providing and fixing terminal guard
17.56.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 Each 5 Included
68 17.6 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
17.60.2 100 mm inlet and 75 mm outlet
17.60.2.3 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 Each 10 Included
69 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. Each 4 Included
GROUP - WATER SUPPLY
70 18.11 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
18.11.1 15 mm dia nominal bore Meter 50 Included
71 18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
18.13.1 25 to 40 mm nominal bore Each. 2 Included
72 18.15 Providing and fixing brass bib cock of approved quality :
18.15.1 15 mm nominal bore Each 15 Included
73 18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
18.22.2 150 mm diameter Each 6 Included
74 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
18.51.1 15 mm nominal bore Each 3 Included
75 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
18.52.1 15 mm nominal bore Each 18 Included
76 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
18.53.1 15 mm nominal bore Each 5 Included
77 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 225 Included
78 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 210 Included
79 21.2' Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge
21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side Sqm 32 Included
80 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) sqm 65 Included
81 21.4 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
21.4.1 With stainless steel cover plate minimum 1.25 mm thickness each 8 Included
82 21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
21.8.1 Upto 5mm depth and 5 mm width metre 50 Included
83 21.13 Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. each 2 Included
84 26.19 Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses.
26.19.1 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm. Sqm 260 Included
85 26.88 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
26.88.1 30 mm thick Sqm 4 Included
86 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.28.1 Semi rigid pipe
17.28.1.1 32mm dia each 5 Included
TOTAL (FOR SCHEDULED ITEMS) (EXCL. GST)
Date : Printed Name :
Place : Designation :
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Schedule - 2
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(SCHEDULE OF RATES AND PRICES : PART-B- Non Scheduled Items
Bidder’s Name and Address To:
Bidder as Contract & Material
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
All values are in Indian Rupees.
SI. No. Item no. Item Description Unit Qty. Rate Amount
PART-B:Non-Schedule Items
1 NS-1 Masonry work with Fly Ash bricks of average compressive strength of 50Kg/cm2 in foundation and plinth level in cement mortar 1:6 (1 cement :6coarse sand). Cum 25 Included
2 NS-2 Masonry work with Fly Ash bricks of average compressive strength of 50 Kg/cm2 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 (1 cement:6coarse sand). Cum 87
3 NS-3 Half brick masonary with Fly Ash bricks of average compressive strength of 50 Kg/cm2 in super structure above plinth level upto floor V level Sqm 28 Included
4 NS-4 Providing & fixing under counter modular kitchen storage rack by making drawer of 500mm depth with laminated shutter having thickness of 18mm including 16mm of MR plywood(GRADE) front finish with 1mm glossy/mat finish laminated sheet and 0.8mm back white balancing sheet by providing suitable arrangement with aluminum(minimum 1.1mm thick) framing work filled with 2nd class teak wood, arrangement of drawer with stainless-steel (SS-202 grade) with soft close hinges, shelf, thali, plate attachment, SS cutlery tray fixing etc. complete. (Front face of the kitchen cabinet shall be considered for measurement) Sqm 7.800000000000001 Included
5 NS-5 Providing & fixing over head storage unit made of carcass both side white laminated (plywood edges with 0.8mm thick PVC edge banding with hotmelt glue using through feed edge banding machine with automatic snipping, trimming & buffing units, joined together using imported hardware like minifix)unit by making cabinet of 300mm depth with laminated shutter having thickness of 18mm including 16mm of MR plywood(GRADE) front finish with 1mm glossy/mat finish laminated sheet and 0.8mm back white balancing sheet with soft close hinges etc. complete including all necessary fittings. (Front face of the kitchen cabinet shall be considered for measurement) Sqm 6 Included
6 NS-6 Providing and filling in foundation, plinth and floors with good quality murrum in layers of 20 mm each including watering, cmpaction and its transportation by mechanical/manual means with all leads and lifts ttc complete. (Compacted volume of murum shall be measured and paid) Cum 100 Included
7 NS-7 Water Proofing with Dr. Fixit Hydro Shield PUD Plus
(i) Surface Prepararion: The RCC slab top shall be provided with avg. 40mm thick (cement concrete 1:2:4) screed with wod float finish & a minimum slope of 1:100 shall be provided towards nearest rain water spouts. The screed concrete shall be cured for atleast 15 days. The top surface shall be free fom any dust/loose particles. The surface shall be washed with clean water and shallbe in dry condition before commencement of work. The item for screeding shall be paid separately under respective item.
(ii) Cracks/Joint Treatment: All cracks developed on RCC slab/Screed surface shall be repaired as follows: (a) Cracks up to 5mm wide: All cracks should be opened to atleast 1 - 5 mm with “V” groove for ease of application, then filled with acrylic crack filler Dr. Fixit Cracks-X paste as per manufacturer recommedations. (b) Cracks more than 5mm wide: Cracks more than 5 mm shoud be repaired with Polymer modified cement sand mortar in the Ratio of 1:3 duly admix with Dr. Fixit Pidicrete URP @ 10% by weight of cement Or with Dr. Fixit Polymer Mortar HB a ready to use single component polymer modified repair mortar. Allow to cure for 5-7 days /moist cure as usual. Ensuring it adheres to the surface. c) If the surface is porous: Apply primer coat prepared with Dr. Fixit Crack X Paste and water 1:1 proportion over the crack. Fill Dr. Fixit Crack x Paste when the surface is tacky not dried. Allow it to set for 24 hours.(Nothing shall be payable for crack repairing as the work is New)
(iii) Priming: To ensure proper adhesion surface should prime with a single coat of Dr. Fixit Primeseal dilute with water in the ratio 2:1 spreading at the rate of 8-10 /Sq.mt /Litre Substrate MUST be in SSD condition for application of primer. Allow the primer to cure according its technical instructions.
(iv)Water Proofing: (a) Making Gola/Angle Fillet: Gola/Angle fillet of suitable size shall be prepared with Dr. Fixit URP (PMM) as per direction of Engineer-in-Charge. (b) Application of water proofing chemical: The water proofing shall be carried out up to 300mm from top of screed on parapet wall. Apply 1st coat of Dr. Fixit Hydroshield PUD Plus without dilution. Spreading at the rate of 0.45 /litre/ Sq.mt/Coat until all surface is covered. While the underling coat is still wet, lay a 45 GSM Fiberglass Mesh as a reinforcing material which is incorporated between the first coat and second coat.Apply second coat at 90° to the first coat. Ensure there are no pinholes or air bubbles on the membrane surface without dilution spreading at the rate of 0.45 /litre/ Sq.mt/Coat. Apply a third coat with the same coverage and consumption to achieve @1.30- 1.40 /Litre/Sq.mt for 0.850 to 1000 microns DFT with forced coverage method. Allow complete drying between coats with a minimum 5-6 hours depending on the weather condition. Make sure glass fibre mesh is completely embedded. Surface should be smooth after the application. Check to see no void surface is left untreated / uncoated. All joints/corners/drainage flange, outlets and penetration points shall be treated prior to all application of Dr. Fixit HydroShield PUD Plus. All corners, gaps, joints, protrusions and outlets should be coated with an extra coat incorporating fibre mesh ensuring no pinholes or air bubbles are present on the membrane surface.
(v) Drying/Curing: Allow the water proofing membrane to cure for atleast 7-8 days before ponding test.
(vi) Ponding: Flood the terrace with water water up to 50 mm height for 48 hours to ensure leak-free terrace. Sqm 520 Included
8 NS-8 Providing and fixing White Vitreous table top wash basin of size (550 X 400 X 140)mm with 32 mm C.P. brass waste coupling of standard pattern as per direction of engineer-in-charge. each 6 Included
9 NS-9 Providing and fixing Sink Cock / wash basin cock with Raised ‘J’ Shaped Swinging Spout (Table Mounted Model), Jaquar (Continental, Cat. No: CON-359KN) make or equivalent, as approved by Engineer in Charge each 6 Included
10 NS-10 Providing & assembly of starlock arrangement for sliding alluminium windows. each 18 Included
11 NS-11 Dismentaling of panels of MS windows and stacking the materials within a lead of 50m as per direction of Engineer-In-Charge. Sqm 14 Included
12 NS-12 Providing & fixing of Stainless Steel handle of size 450MM (OZONE MAKE-OGH-55W-32X457MM WSS) of approved design as per direction of Engineer-in-charge. each 1 Included
13 NS-13 Providing and fixing CP brass health faucet with PVC flexible tube with wall hook.(JAQUAR Model : 573 or Equivallent) each 4 Included
14 NS-14 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including patch fittings equivalent to Ozone make of top patch & bottom top pivot, corner pach lock, H type handle 32 x 457 mm equivalant to Ozone make Model No. OGH 55 & floor machine fixing arrangement and making neccessary holes cutout etc. all complete as per direction of Engineer in charge. (Glass make Saint Gobain / Modi Float or equivalant & hardware Make Ozone / Trium Or equivalant approved by Engineer in charge) Sqm 25 Included
Total (PART-B) - Non Scheduled Items (EXCL. GST)
Date : Printed Name :
Place : Designation :
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(SCHEDULE OF RATES AND PRICES : PART-III (SEWERAGE SYSTEM), PART-A- SCHEDULED ITEMS AS PER DSR-2014)
Bidder’s Name and Address To:
Bidder as Contract & Material
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
All values are in Indian Rupees.
SI. No. ITEM NO. Item Description Unit Qty. Rate Amount
PART-III Construction of SEWERAGE SYSTEM for Residential Qtr
PART-A - (SCHEDULE ITEMS AS PER DSR - 2016)
1 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil Cu.m. 60
2 2.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
2.10.1.2 Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia. Metre 1000
3 2.11 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). Metre 50
4 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cu. M 20
5 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cu. M 50
6 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for :
4.3.1 Foundations, footings, bases for columns Sq.m. 80
7 17.35 Providing and fixing soil, waste and vent pipes :
17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 metre 10
8 18.27 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 :
18.27.3 150 mm dia pipe metre 50
9 18.28 Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead :
18.28.3 150 mm diameter pipe each 20
10 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
19.1.2 150mm diameter Metre 1000
11 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
19.2.2 150 mm diameter S.W. pipe Metre 1000
12 19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
19.6.4 300 mm dia RCC pipes. metre 30
13 19.15 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
19.15.1 With 20x20 mm square bar Each 30
Sum of Items as per DSR-2016
Percentage quoted above (+) / below(-) DSR-2016
Total for PART-III (PART-A) -(Schedule Items)
Date : Printed Name :
Place : Designation :
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Schedule - 2
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(SCHEDULE OF RATES AND PRICES : PART-III (SEWERAGE SYSTEM), PART-B- NON SCHEDULED ITEMS)
Bidder’s Name and Address To:
Bidder as Contract & Material
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
All values are in Indian Rupees.
SI. No. Item no. Item Description Unit Qty. Rate Amount
PART-II Construction of SEWERAGE SYSTEM for Residential Qtr
PART-B NON-SCHEDULE ITEMS
1 NS-1 Construction brick masonary manholes in cement mortar 1:4 - 1 cement : 4 coarse sand- R.C.C. top slab with 1:2:4 mix -1 cement : 2 coarse sand : 4 approved graded stone aggregate 20mm nominal size- foundation concrete 1:4:8 mix -1 cement : 4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastring 12mm thick with cement morter 1:3(1 cement:3 Coarse sand) finished with a floating coat of neat cement and making channel in cementconcrete 1:2:4 (1 cement:2 coarse sand:graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design of CPWD.
Inside size 90X80 cm and 45cm deep including C.I. Cover with frame (light duly) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 Kg (weight of cover 23 Kg and and weight of frame 15 Kg)
a With Fly Ash Bricks Each 40
2 NS-2 Extra for depth for manholes
With Fly Ash Bricks of average compressive strength of 50 Kg/cm2 Meter 35
Total PART-III ( PART-B) - (Non-Schedule Items)
Date : Designation :
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Schedule - 3
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID As per Lum-sum
(SCHEDULE OF RATES AND PRICES : PART-C- ELECTRICAL ITEMS) AS per Percent
As per lum-sum on Sch-3
Bidder’s Name and Address To: As per Percent on Sch-3
Bidder as Contract & Material Multipackage lum-sum
Name : Power Grid Corporation of India Ltd., Multipackage on Percent
Address : Western Region -I Headquarters Total Discount
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
All values are in Indian Rupees.
SI. No. Item Description Unit Qty. Rate Amount
Part-C -ELECTRICAL PART
A MAIN CIRCUIT WIRING: From MDB Panel / Meter Panel To SDBs (Ground Floor)
Supply, laying, installation towards main circuit wiring from Meter Panel / MDB to respective SDBs as per the drawing, interior layout, site conditions in concealed / recessed medium gauge PVC conduit (ISI approved) including supply of conduits and its accessories, FR type wires (ISI approved) and other required materials as per technical specification and as per direction of Engg-in-charge (Conduits to be laid in columns, beams, slabs before concreting in walls and before or after the walls are raised as required by structural restraint) complete for the following :-
1 4X6 sq.mm + 2 X 4 sq. mm(green) PVC insulated Copper Conductor Multistrand wire, Mains wiring For Meter panel as per the direction of engg-in-charge Mtrs 25 Included
2 2X6 sq.mm + 1 X 4 sq. mm(green) PVC insulated Copper Conductor Multistrand wire, Mains wiring from Meter panel to RCCB of SDB as per single line drawing, site condition and Direction of engg-in-charge Mtrs 100 Included
B SUB CIRCUIT WIRING - from SDBs to Switchboards ; 6A power sockets ; 16A & 25A Power sockets & Weather proof power sockets :-
Supply, laying, installation towards sub circuit wiring from SDBs(Ground floor ) to Switchboards; 6A; 16A & 25A Power sockets as per the drawing, interior layout, site condition in separate individual concealed / recessed medium gauge PVC conduit (ISI approved) including supply of conduits and its accessories, FR type wires (ISI approved) and other required materials as per technical specification and as per direction of Engg-in-charge (Conduits to be laid in columns, beams, slabs before concreting in walls and before or after the walls are raised as required by structural restraint) complete for the following :-
1 SDB to Switch Board to AC Switch Sockets Point and Power Points :- Mtrs 60
Main with 2x4 Sq.mm and earth wire 2.5 sq.mm FR PVC Copper conductor Multistrand wires in PVC Conduit as per the technical specification.
2 SDB to Switchboards and Switchboard to Switchboard :- Mtrs 100 Included
Main with 2x 2.5 Sq.mm and earth wire 1.5 sq.mm FR PVC Copper conductor Multistrand wires in PVC Conduit as per the technical specification.
C POINT WIRING :- (From switchboard to individual light points / street light point / ceiling fan point / Ex-fan points):-
Supply, laying and installation towards point wiring with 1.5sq.mm (for phase, neutral & earth ) 1100V PVC insulated copper conductor multistrand FR type wires (ISI approved) in recessed medium gauge PVC conduit (ISI approved) as per the drawing, interior layout, site condition including supply of conduit, associated conduit accessories, wires and other materials required as per technical specification and as per direction of engg-in-charge (Conduits to be laid in columns, beams, slabs before concreting in walls and before or after the walls are raised as required by structural restraint) complete for the following :-
1 From Switchboard to Light point / Ceiling fan / Exhaust fan / Bell Point / 6 A Switch Sockets :- Mtrs 350 Included
Main with 2x1.5 Sq.mm and earth wire 1.5 sq.mm FR PVC Copper conductor Multistrand wires in PVC Conduit as per the technical specification.
D MODULAR SWITCHES, BOXES, COVER PLATES FOR LIGHT, CEILING FAN, BELL POINTS, BELL STATION, 6A SWITCH SOCKET & 15A POWER SOCKETS.
Supply, installation, testing and commissioning of wiring accessories of approved ISI/CE certified make modular range such as modular switches, switch socket outlets, power sockets, etc. for the following with suitable mounting plates & boxes (modular range) in the required configuration as per the interior layout and direction of engg-in-charge
1 10A single pole, 1way switch for light and for 6A power points of ISI mark approved make. Nos. 200 Included
2 10A single pole, 2 way switch for ceiling fan and light of ISI mark approved make. Nos 20 Included
3 6A, Multipin 5/6 Socket of ISI mark approved make. Nos. 40 Included
4 16 & 6A ,6 pin heavy duty Socket with independent switch along with indicator of ISI mark approved make. Nos. 30 Included
5 20 A , Single pole, 1 way switch of ISI mark approved make for with Indicator for Geysers and Heater. Nos 20 Included
6 16 A , Multipin 5/6 pin Socket of ISI mark approved make for with Indicator for Geysers and Heater. Nos 20 Included
7 32A Switch and 20 A Socket for AC unit of ISI mark approved make. Nos. 16 Included
8 Electronic regulator (Step type) for ceiling fan / Wall mounting fan of ISI mark approved make. Nos. 20 Included
9 T.V socket single outlet of ISI mark approved make. Nos 12 Included
10 10A one way bell push with indicator of ISI mark approved make. Nos 7 Included
11 Musical door bell of ISI mark approved make. Nos 10 Included
12 Concealed type modular switch box with double mounting plate for 1/2 module of ISI mark approved make. Nos. 25 Included
13 Concealed type modular switch box with double mounting plate for 3 module of ISI mark approved make. Nos. 15 Included
14 Concealed type modular switch box with double mounting plate for 4 module of ISI mark approved make. Nos. 13 Included
15 Concealed type modular switch box with double mounting plate for 6 module of ISI mark approved make. Nos. 13 Included
16 Concealed type modular switch box with double mounting plate for 12 module of ISI mark approved make. Nos. 30 Included
E WIRING,SOCKET AND J. BOX FOR TELEPHONE POINT :-
Supply, laying & installation towards telephone point wiring including supply of medium gauge PVC conduit (ISI approved), PVC insulated 2 pair of 0.55 mm dia. electrolytic tinned copper wire in a separate PVC conduit from the telephone tag block(EPABX) to individual( telephone outlet point as per the drawing, site condition including its associated accessories and others of the following :-
1 Supply and Erection of 20 MM Conduits with required associated accessories. Mtrs 100 Included
2 Supply and Erection of Telephone cable 2 pair with 0.5 mm dia of ISI mark approved make. Mtrs 100 Included
3 Telephone socket one gang with safety shutter of ISI mark approved make. Nos. 9 Included
4 Supply, Erection and Commissing of Junction Box suitable for 20 Pair tag blocks in 2 nos of 10 pair krone, disconnector type, complete with metal enclosure powder coated, krone tag block mounting arrangement of ITI approved make or eqvt. make. Set 1 Included
F CONDUIT, WIRING,SOCKET & BOX FOR TV AMPLIFIER OF TV POINTS :-
Supply, laying and installation of RG coaxial cable including supply of medium gauge (MMS) PVC conduit from Junction box to individual T.V. socket as per the interior layout and direction of engg-in-charge for the following:-
1 Supply and Installation of RG - 6 /11 coaxial cable (Finolex make, Or eqvt. make ) Mtrs 50 Included
G Main Incoming Panel
1 TP SDB (SUB DISTRIBUTION BOARD) Supply ,Installation ,testing & commissioning Test lab with 4 Pole, 125 Amp Isolator as incomer- 1 no. and outgoings suitable for accommodating the following of 6A,10A & 20A, 1 pole MCBs, 10 KA short circuit rating capacity, which is to be installed as per the direction of engg-in-charge. In the phase segregated design with all accessories like fork bus bars, lugs, leads, FLUSH MOUNTED with double glazed door complete, suitable size cable entry jumpers space for incoming / outgoing cables CONCEALED IN WALLS/ erected on suitable angle iron frame (if applicable) of Hager or other eqvt. make as required as per technical specification (Note :- 4 pole 63 Amp, Isolator is included in the above item & outgoing 1 pole, MCB is as per item no. H.5) Set 1 Included
2 Supply and Erection of Metal Box of 16 Gauge CRCA sheet with Self locking arrangement with duplicate key including painting, cutting and fabricating for accommodating TP SDB and 3 Phase Energy Meter including all other required accessories as per the direction of Engineer In-charges Nos 1 Included
3 Supply, installation, testing & commissioning of 1 Pole MCBs Type-C of following rating,10KA Short circuit rating installed in the outgoing above SDBs as per single line / power schematic diagram. Nos 16 Included
1P 6A to 32A, cat no.NC 106N/110N/116N/120N/132N make L&T (or) equivalent make
I SUPPLY OF ENERGY SAVER LIGHT FITTINGS/FIXTURES, WEATHER PROOF STREET LIGHT FLOURESCENT FITTINGS; CEILING FAN; WALL MOUNTING FAN; EX-FAN AND ERECTION/ INSTALLATION WORKS :-
Providing, installation, testing and commissioning of pre wired FLOURESCENT Fitting / CFL complete with Tube etc., in all respect on ceiling with necessary down rods as required or wall or recessed mounting as per the site condition and direction of engg-in-charge.
1 Supplying & Erecting of 1 x 22 W T-8 Energy Efficient LED Tube light fitting including LED tube with heat sink, integrated HF electronic driver . Similar to Syska model SSK-T5-22W or equivalent Nos 20 Included
2 Supply, erection, testing and commissioning of ceiling mounted 9 to12 Watt Circular LED down lighter fitting , Including LED lamp and all other required accessories including LED. to complete the work. The make should of Philips, Bajaj , CG ,Syska, Wipro or reputed make . as per direction of engg-in-charge Nos 20 Included
5 Supply and Installation on Single light fancy wall bracket in cluding 7 to 8 watt LED lamp with arm fabricated from brass duly lacquered with suitable holder and fancy glass shade duly wired erected on wall with suitable size polished wooden / laminated board.The make of LED should of Philips, Bajaj , CG ,Syska, Wipro or reputed make . as per direction of engg-in-charge Nos 12 Included
6 Supply and installation of 1 X18 W LED mirror mounted fitting with slim channel with opal acrylic diffuser, end caps & coloured rims including mounting accessories and 18 W CFL lamp of Bajaj Cat. No. BSP 118 CFL (or) equivalent model of Philips , Bajaj , CG, syska or reputed make for Wash Area as per interior layout, site condition and direction of engg-in-charge. Nos 8 Included
7 Supply, erection, testing and commissing of BEE Five Star,1200mm sweep, double ball bearing ceiling fan with condenser A.C. 230V, 50 cycles with canopy, down rod up to required length with rubber bushing, bolts & nuts, including fan hook box of required size complete erected and marking the Sr.no. and date of erection. The recommended colour of ivory,white,brown of Bajaj (Regal) , Crompton Aura (or) Usha (or) Orient (or) GEC Alstom make or reputed make . as per direction of engg-in-charge Nos 15 Included
8 Supplying, erecting, testing and commissioning of fresh air cum Exhaust fan of domestic heavy duty 250 Vac 50 Hz, 300 mm, 1400 RPM suitable for continuous duty in crowded kitchen rooms, toilets, lavoratories with double ball bearing with metallic body of approved make Crompton (or) Almonard (or) GEC (or) equivalent make.The required accessoies for fixing of exhaust fan on wall / Frame shall be in scope of contractor and providing necessary metal sheet CAWL to avoid bird entry (if Applicable) Nos 8 Included
10 Supply ,Erection and Commissioning of Ceiling rose with hanging hook for Chandelier. Nos 16 Included
J LIGHTNING PROTECTION
1 Providing & fixing Copper lightning conductor ( at the roof top ) made of 40 mm dia Copper pipe of standard length with 5 Nos Spikes at the top including holes etc.for fixing as required. Set 1 Included
2 Providing and fixing 25mm x 3mm Aluminium Earthing Conductor from Base of Lightning Conductor to independent Earthing Pits including interconnection of both pits as required( for Vertical as well as horizontal run). Jointing of Al Strips to be done by riveting and welding having overlaps of 150mm. Kg 5 Included
K EARTHING STATION, EARTHING CONDUCTOR, G.I. Plate & GI Pipe :-
Supply,laying, installation,connecting,testing & commissioning of following earthing station, earthing conductor for difference purposes as specified in the technical specification & as per IS:3043 :-
1 2 nos. of 25 x 6mm G.I. Strip from MDB to the earthing station all along the concrete pathway / road / all along the cable trench as per site condition and as per direction of engg-in-charge. Kg 5 Included
2 Providing Copper Plate (60x60x0.315cm) earthing station as specified in IS:3043 and 25 kg of maintenance free earth conductivity enhancing mineral earthing compound with excavation, treatment of soil, providing test link, 50*6mm G.I strip from earthing link and connected to the meter panel; making of chamber along with watering funnel with C.I cover hinged to C.I. Frame. Set 1 Included
Total (PART-C) - (Electrical Items) (EXCL. GST)
Date : Printed Name :
Place : Designation :
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Schedule - 5
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(GRAND SUMMARY)
Bidder’s Name and Address To:
Bidder as Contract & Material
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Sl. No. Description
1 PART-A- Scheduled items
2 PART-B- Non Scheduled Items
3 PART-C- ELECTRICAL ITEMS:
Total of (PART-A + Part-B+PART-C), excluding GST
Place : Printed Name :
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Schedule - 5 After Discount
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
(GRAND SUMMARY - AFTER DISCOUNT)
Bidder’s Name and Address To:
Bidder as Contract & Material
Name : Power Grid Corporation of India Ltd.,
Address : Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Sl. No. Description Total Price (INR) Total Discount
Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
1 PART-A- Scheduled Items
2 PART-B- Non Scheduled items
3 PART-C- ELECTRICAL ITEMS
Total of (PART-A + Part-B+PART-C)
GRAND TOTAL after Discount, excluding GST
Place : Printed Name :
This letter of discount is optional. Bidder may / may not offer any discount.
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Letter of Discount
LETTER OF DISCOUNT
Contract & Material
Power Grid Corporation of India Ltd.,
Western Region -I Headquarters
Sampriti Nagar, Nari Ring Road
PO: Uppalwadi, Nagpur (MS) -440026
Subject : Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID
1) All the discounts mentioned below shall be applied separately.
2) Please verify Schedule-5 (after Discount) after filling this letter of discount.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us. [The discount shall be proportionately applicable on all the items of all the Schdules of all the Parts i.e. (PART-A + Part-B+PART-C) In Rs.
2 Discount on percent basis on total price quoted by us. [The discount shall be proportionately applicable on all the items of all the Schdulesof all the Parts i.e. (PART-A + Part-B+PART-C) In Percent (%)
1) Discount is Optional. 2) Bidder may fill any of the above two Indicated Discounts or both the Discounts. 3) Discount(s) offered at Sl. No. 1 to 2 will automatically simultaneously get accounted for in all the Schedules of all the Parts..
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
1) All the discounts mentioned above shall be applied separately.
2) Please verify Schedule-5 after filling the above letter of discount.
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Specification No.: WR-I/C&M/2022/NIT-27/Package-A/Rfx- 5002002338 Bid Form 2nd Envelope 1 st 1 January
2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : 6 th 6 June
To: 8 th 8 August
Contract & Material 9 th 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
Western Region -I Headquarters 11 th 11 November
Sampriti Nagar, Nari Ring Road 12 th 12 December
PO: Uppalwadi, Nagpur (MS) -440026 13 th
Name of Contract : Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID 15 th
Dear Ladies and/or Gentlemen, 16 th
0.0 In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to execute the work of Work for Repairing and Modification of Old Guest House, Construction of New Kitchen Room with Modification of Old Dining Hall at 400/220kV Substation, Raipur(C.G.) POWERGRID under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 0 (Rupees only) or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents. In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to execute the work of under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents. (Rupees only) 17 th
Sch-1 PART-A-SCH Items 21 st
Sch-2 PART-B- Non -Sch Items
Sch-3 Electrical Items:
Sch-4 GRAND SUMMERY
Sch-5 After Discount GRAND SUMMERY after DISCOUNT
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
0.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
zero crore Rupees
23 twenty three
27 twenty seven
28 twenty eight
33 thirty three
37 thirty seven
38 thirty eight
73 seventy three
74 seventy four
75 seventy five
77 seventy seven
78 seventy eight
79 seventy nine
83 eighty three
87 eighty seven
88 eighty eight
93 ninety three
97 ninety seven
98 ninety eight
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
00- TENDER DETAILS.docx
docx • 0.13 MB
1-1-IFB.docx
docx • 0.15 MB
1-2-ITB.doc
doc • 1.81 MB
1-3-A-Annexure A (BDS-QR.pdf
pdf • 0.14 MB
1-3-BDS.doc
doc • 1.66 MB
1-4-GCC.doc
doc • 0.53 MB
1-4A-Model Rules & Safety Code.doc
doc • 1.63 MB
1-4B-Registers.pdf
pdf • 0.12 MB
1-5-SCC.doc
doc • 1.66 MB
1-6-Forms Proce.doc
doc • 1.64 MB
3-1-Attach Bid Forms-I.xls
xls • 2.62 MB
Annexure-C(BDS).docx
docx • 0.13 MB
Drawing.pdf
pdf • 1.62 MB
Price_schedule.xls
xls • 1.48 MB
SFQP.pdf
pdf • 2.18 MB
Technical Specification_Electrical.doc
doc • 0.15 MB
~$6-Forms Proce.doc
doc • 0.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .