| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹1.0 L+₹2,050 (2.01%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L2 | Rejected-Finance Rejected Financially | |
| 3 | L3₹1.1 L+₹5,250 (5.15%)Rejected-Finance | L3 | Rejected-Finance Rejected financially |
| Sl No | Description | Qty | Unit | GLYPTIC L2 | Greentech Solution L3 | Integrated Engineering Solutions L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply installation Testing & Commisioning of EN -54 standard VDS/LPCB Approved Addressable Multi sensor Detector (optical smoke as well as heat ) with inbulit / additional isolator and integral LED status indicator with 360 degree viewing angle Detector shall commumcate 3 danger levels for differentiated alarm activation and high tolerance to dust dirt temperature fluctuation and air currents Detector should have unquie address for communication and assigned through panel with Mounting Base as rqequired with the protection category of IP40. (Approved Make: Siemens). | 10 | Nos | 4,800 ₹48,000 | 5,000 ₹50,000 | 4,700 ₹47,000 Lowest |
| 2.00 | Supply, Installation, Testing & Commissioning of Intelligent Addressable EN Standards & VDS Approved Manual Call Point with Necessary accessories for fitting, J.B etc. (Approved Make: Siemens). | 1 | No. | 6,600 ₹6,600 | 6,600 ₹6,600 | 6,500 ₹6,500 Lowest |
| 3.00 | Supply, Installation, Testing & Commissioning of EN Standards & VDS Approved Loop Powered Sounder cum Strobe with necessary accessories for fitting, J.B etc. (Approved Make: Siemens). | 1 | No. | 19,600 ₹19,600 | 20,000 ₹20,000 | 19,500 ₹19,500 Lowest |
| 4.00 | Supply, Installation, Testing & Commissioning of Response Indicator. (Approved Make: Siemens). | 6 | Nos | 275 ₹1,650 | 275 ₹1,650 | 250 ₹1,500 Lowest |
| 5.00 | Supply & Laying of 1.1KV grade 2 nos 1.5 sq.mm PVC insulated Shielded FRLS copper Cable (Make. Finolex/Polycab/Gloster) for Looping.in PVC (Approve Make) conduit including Supply & Fixing of 20 mm complete with all accessories. | 100 | Mtrs. | 130 ₹13,000 | 130 ₹13,000 | 125 ₹12,500 Lowest |
| 6.00 | Testing & Commissioing of existing SIEMENS MAKE FDA PANEL installed at (Gr. Floor of Ronald Ross Building) with all connection of all fire detection system devices which is newely & existing both installed at the afforsaid floor as per direction by EIC. | 1 | Job | 15,200 ₹15,200 | 16,000 ₹16,000 | 15,000 ₹15,000 Lowest |
| 7.00NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation. | ||||||
| 8.00TESTS: 1. The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system under active monitoring of OEM. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Before taking up the work necessary building drawing/ floor plan with layout should be prepared and to be approved from the fire safety Cell of PWD according to the prevailing fire safety policy. After commissioning, necessary testing to be done in presence of fire safety cell. | ||||||
| 9.00TERMS & CONDITIONS :- | ||||||
| 10.00The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules | ||||||
Tender Value
₹1.0 L
EMD Value
₹2,080
Closing Date
19 Sept 2025, 12:00 pmClosed
Exe. Engr.-I, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Urgently Repairing and Renovation of Electrical Installation Works with allied Fire Detection System at Seminar Room, Department of Gynae an Obs at 3rd floor of Ronald Ross Building within the compound of IPGMER-SSKM Hospital, Kolkata-Fire Detection
2025_WBPWD_894952_1
WBPWD/EE-I/KSHED/Q53/25-26
Open Tender
FIRE FIGHTING ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,080
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
3 Sept 2026
26 Aug 2025
22 Sept 2025
26 Aug 2025
19 Sept 2025
2 Sept 2025
1 Sept 2025
Amount
Supply installation Testing & Commisioning of EN -54 standard VDS/LPCB Approved Addressable Multi sensor Detector (optical smoke as well as heat ) with inbulit / additional isolator and integral LED status indicator with 360 degree viewing angle Detector shall commumcate 3 danger levels for differentiated alarm activation and high tolerance to dust dirt temperature fluctuation and air currents Detector should have unquie address for communication and assigned through panel with Mounting Base as rqequired with the protection category of IP40. (Approved Make: Siemens).
Supply, Installation, Testing & Commissioning of Intelligent Addressable EN Standards & VDS Approved Manual Call Point with Necessary accessories for fitting, J.B etc. (Approved Make: Siemens).
Supply, Installation, Testing & Commissioning of EN Standards & VDS Approved Loop Powered Sounder cum Strobe with necessary accessories for fitting, J.B etc. (Approved Make: Siemens).
Supply, Installation, Testing & Commissioning of Response Indicator. (Approved Make: Siemens).
Supply & Laying of 1.1KV grade 2 nos 1.5 sq.mm PVC insulated Shielded FRLS copper Cable (Make. Finolex/Polycab/Gloster) for Looping.in PVC (Approve Make) conduit including Supply & Fixing of 20 mm complete with all accessories.
Testing & Commissioing of existing SIEMENS MAKE FDA PANEL installed at (Gr. Floor of Ronald Ross Building) with all connection of all fire detection system devices which is newely & existing both installed at the afforsaid floor as per direction by EIC.
NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
TESTS: 1. The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system under active monitoring of OEM. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Before taking up the work necessary building drawing/ floor plan with layout should be prepared and to be approved from the fire safety Cell of PWD according to the prevailing fire safety policy. After commissioning, necessary testing to be done in presence of fire safety cell.
TERMS & CONDITIONS :-
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
GLYPTIC (BID ID -6950249)
Greentech Solution (BID ID -6951310)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .