Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
10 Jul 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Project Manager
Office of Project Manager Construction Unit Muzaffarnagar Uttar Pradesh Avas Vikas Parishad 114 Shakuntalam Yojana Muzaffarnagar 251001
Construction of RCC Over Head Tank Of 25 KL Capacity at 18 M Staging From Made Up Level at Cheif Medical Officer Office District Shamli
2020_UPHDB_489055_1
265/AC-9/22, Date- 01.07.2020
Open Tender
Civil Works
Item Wise
150 days
Shamli
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
Project Manager Construction Unit Muzaffarnagar
₹22,000
Yes
13 Jul 2020
2 Jul 2020
13 Jul 2020
2 Jul 2020
10 Jul 2020
2 Jul 2020
90 days
Amount
Submission of design, drawing and supply of all material, labour, T&P etc. and construction as per tenderer's own seismic proof design and drawings complete intze type on raft or pile cum raft foundation with columns and braces RCC over head tank 25 KL capacity at 18 M staging from made up ground level at site to the top of bottom ring beam of tank, with a minimum free board of 15cm. The design of the tank shall base on safe bearing capacity of soil at site as 8 T/sqm and depth of foundation as 2.50 M from existing ground level on pile/raft foundation made up level of OHT will be taken as 0.60 M above existing ground level. Extra earth required for made up level will be arranged by the contractor at his own cost. If the bearing capacity of soil is found less than 8 T/sqm as per testing agency report the contractor will submit the design on the B.C. proposed by the testing agency. No extra payment will be paid for this change. If the B.C. is found more than 8 T/sqm as per testing report than the design of OHT done at B.C. 8 T/sqm and depth 2.5 M or the depth suggested by testing agency. All other details of tank not covered here shall also be as per specification as under.
Submission of detailed design and drawing from any recognized University such as IIT etc. or as per direction of Engineer-in-charge.
RCC as per approved design including fixing various pipes and ventilator at top and fixing of M.S. sheet of 10mm gauge manhole cover of 60cm x 60 cm size with frame and locing arrangement and railing including supply of all material.
R.C.C. stair case with 0.75 mtr. minimum or as per design clear width attached with tank body as an access to balcony and top balcony and top Dome of tank from ground level as per design & drawing with 1.25 M high railing and gate with cabin as per specification including supply of all materials.
Supply and fixing of M.S. ladder from inside the tank from roof body from roof to the bottom dome of the tank in a slope of 3:1 (3 Vertical : 1 horizontal) with railing as specified.
Railing on staircase & its landings, all around balcony & top dome for access up to ventilator as specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe.
Supply and fixing of water level indicator as per specifications and fixing of lightening conductor and Earth plate etc. as per specifications.
Testing of tank for water tightness as per specificaions enclosed including supply of water.
Supply of all materials and construction of 80mm thick P.C.C. floor, apron and 15 cm dia semi circular drain around apron in a slope towards wash out chamber.
Three coats of approved quality and shade of Apex painting of as per direction of Engineer-in-charge over concrete work including supply of all materials etc.
Three coats of anti corrosive/aluminium/black japan paint of approved quality on all iron work including supply of all material, labour and T&P etc.
Supplying, carting and fixing of following sizes G.I. Class- B pipes with required specials such as reducers, foot bend (bell mouth etc in inlet of tank) including supply of M.S. clamps, rubber insertion sheet, nut bolts washer etc. complete as per specifications.
80mm dia in inlet
80mm dia in outlet
80mm dia in over flow
80mm dia in wash out.
Supply and fixing of following sizes C.I. D/I sluice valves as per relevent latest I.S. specifications including supply of all jointing and other materials such as rubber insertion sheet, nut bolt, washer etc. complete as per specification
80 mm dia in inlet
80 mm dia in outlet
80 mm dia in wash out.
Supply all materials labour, T&P and construct brick masonry sluice valve chambers including R.C.C. cover as per deptt. type design at inlet, outlet and washout pipes. The R.C.C. cover shall be casted in M.S. channel section with handles on both sides.
The words year of construction, capacity of O.H.T. and slogan approved by Engineer-in-charge shall be painted prominently in letter not less than 30 cm. in height.
Maintenance for 12 months including supply of all materials etc. complete.
M/s Raunak Enterprises
Kedia Sales Corporation
stage.html
html • 0.02 MB
finance_733855.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .