| 1 | L1₹13.5 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹14.5 L+₹50,127 (3.58%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹14.9 L+₹85,687 (6.11%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
11 Sept 2021, 6:00 pmClosed
Sh Himanshu
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2021_MES_468029_1
GE(S)/PAT-27/PN/2021-22
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Patiala and Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (S) Patiala
₹32,000
Yes
14 Oct 2021
14 Aug 2021
14 Sept 2021
14 Aug 2021
11 Sept 2021
28 Aug 2021
14 Aug 2021 - 21 Aug 2021
Amount
Dismantling of ceiling fan 1200 /1400 mm sweep, (any make and type, taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire ISI marked including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed, as per the direction of Engineer-in-Charge complete all as specified and directed .
All as per item No 1 here-in-before but exhaust fans up to and incl 230/300 mm sweep.
All as per serial item No 1 here-in-before but exhaust fans of sweep more than 300 mm and upto 480 mm.
All as per serial item No 1 here-in-before but wall fans fans of sweep up to 450 mm.
Replacement of gun metal bush suitable for ceiling fans, exhaust fans and wall fans of any makes/ size complete all as directed.
Replacement of ball bearing of suitable for ceiling fans/ exhaust fans/ wall fans of any size/ make complete all as specified and directed. (Make of bearing : NBC/ SKF).
Replacement of capacitor 2.5 mfd, 230 Volts + 5% dry type complete all as specified and directed . (Make : TIBCON/ ASIAN/ USHA)
All as per item No 07 here-in-before but 3.15 mfd.
All as per item No 07 here-in-before but 4 mfd.
Replacement of rubber reel, nut and bolts, spring washer, split pin for ceiling fans of any Make/ Size, complete all as specified and directed.
Taking down ceiling fan/ wall fans (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/ blade screws, refixing in its original position and testing on full speed complete all as specified and directed incl provn of new cable flexible of copper conductor twin core, PVC insulated of size 23/.0076, 750 mm long and one run of earth wire and tapping rubber insulating all as directed by Engineer-in-Charge. (Make : FINOLEX/ Poly cab/ Havells)
Taking down exhaust fan (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/ blade screws, refixing in its original position and testing on full speed complete all as specified and directed incl provn of new cable flexible of copper conductor twin core, PVC insulated of size 23/.0076, 750 mm long and one run of earth wire and tapping rubber insulating all as directed by Engineer-in-Charge. (Make : FINOLEX/ Poly cab/ Havells)
Replacement of ceiling fan blade ( Set of 3) of 1200 mm sweep ceiling fan including nuts, washers etc complete all as specified and directed suitable for any make of fan. (white/ Brown colour/ as per site requirement).
All as per Serial item No 13 here-in-before but for 1400 mm sweep ceiling fan.
Turning, grinding and making good seat to ball bearing in proper position (Ball bearing not included in this item)
Supply and connecting flexible copper wire Cable flexible of copper wire 0.5 sq mm (white clolour) complete.
Supply & fixing as in repair louvers made out of 0.63 mm galvanised iron sheet for Exhaust Fan of any make and size upto 300 mm all as directed by Engineer-in-Charge.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size 380mm/ 450mm all as directed by Engineer-in-Charge.
Replacement of PVC canopy (upper/ bottom) for ceiling fan of any make and size all as directed by Engineer-in-Charge.
Supply & fixing down rod for ceiling fans made out of MS pipe 15mm bore medium grade 60 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint all as directed by Engr-in-Charge.
Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour) including scrapping existing paint and incl writing MES Number with black paint all as directed by Engr-in-Charge.
Spray painting on outside body of the exhaust fan incl blades any size with synthetic enamel paint (smoke gray colour) including scrapping wxisting paint and incl writing MES Number with black paint all as directed.
Taking down desert cooler fixed at any position cleaning internally and externally by scraping all scales dirt etc and repair to desert cooler to stop any type of leakage, tightening & replacing of screws, nuts and bolts etc all as directed including painting of desert cooler with spray machine with synthetic enamel hammer tone paint over one coat of red oxide primer and refixing of the desert cooler after necessary oiling and greasing of fan and water lifting pump complete all as specified and directed.
Supply and replacement of water lifting pump, 230 volt 50 C/S single phase suitable for desert coolers complete all specified and directed. (Make : GEC/ Cool Home/ Bajaj/ Polar/ Khaitan)
Supplying and replacement wood wool pads of suitable size and providing wire netting of GI wire 1.4 mm dia 25 mm mesh for holding pads complete all specified and directed.
Supplying and replacement high density polythene pipe 15 mm dia for desert coolers complete all specified and directed.
Dismantling and taking out old, unserviceable fan motor from the desert cooler and rewinding with supper enamel winding copper wire of suitable size varnishing etc including replacement of bushes, bearings, washers etc. and assembling testing and refixing in existing position all as specified and directed.
Supply and replacement complete steel body of desert cooler of capacity 3000 cft with front grill and side & back panels duly spray painted with synthetic enamel hammer tone paint over one coat of red oxide primer including dismantling and refixing the old parts i.e fan motor, pump etc in new body, replacing the defective wires, PVC pipes and water distributor, making connections and testing complete all as directed. The body of desert cooler will be fabricated as under :- (a) The top and bottom made out of 1.25 mm thick GI sheet. (b) Side panels (set of three) made out of 1.00 mm thick GI sheet. (c) Front grill of suitable size and of approved quality.
Supply & replacement Air direction grill only made of iron suitable size of desert cooler all as specified and directed.
Supply & replacement Single Phase, Neutral & earth wiring copper cable of size .5/1.0 sqmm of deset cooler from fan motor to regulator, pump to control switches all as specified and directed.
Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz all as specified and directed.
Supply & replacement of exhaust fan motor holding clamps made out of iron of suitable size all as specified and directed.
M&L for Servicing of installed Window type Air conditioner of any make 1.5/ 2.00 TR ton capacity including taking down, dismantling from grill, taking out air conditioner, removing all electrical components, cleaning the AC coils & fin using bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/ greecing moving parts and reassembling complete all as specified and directed. Note :- Various check to be done during servicing of Window type Ac 1.5/ 2.0 TR and spares/ items required for replacement of unsv spare/item will be measured under relavant items.
M&L for Servicing of installed Split Air conditioner of any make 1.5/ 2.0 TR capacity indoor and out door units including taking down, dismantling from grill, taking out air conditioner, removing all electrical components, cleaning with brush, condenser, washing with presure water, oiling moving parts and reassembling complete all as specified and directed. Note :- Various check to be done during servicing of Split type Ac 1.5/ 2.0 TR and spares/ items required for replacement of unsv spare/item will be measured under relavant items.
Carrying out gas leakage check and rectifrying /arresting the same by brazing and recharging refrigerant gas, comissioning and testing to entire satisfaction of Engr-in-charge for 1.5/2.0 TR capaity Window/Split AC. Note :- Gas wiil be measured under relevant item.
Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the AC unit of any capacity and type for satisfactory performance complete all as directed by Engineer-in-Charg.
Supply and replacement of defective front grill decorative suitable for window type AC's 1.5/2.00 ton capacity of any make such as LG/Videocon/Voltas/FEDDER LLOYED / BLUE STAR / CARRIER etc as per the original/existing model of air conditioner
Supply and replacement of operating knobs of window type AC's of any make of make and model as per the existing model/size complete all as specified and directed.
Supplying and replacement of air filter as per original sample complete all as specified for AC's 1.5/2.0 Ton of any type/any make all as directed by Engineer-in-Charge.
Taking down unserviceable Air Conditioner cap. 1.5 ton from any posn. and removing unserviceable burnt sealed unit ( compressor ) from AC and S & Fix new compressor unit and testing on required pressure and installing at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item. (Make of compressor : VOLTAS/ BLUESTAR/ Lloyd/ carrier)
Taking down unserviceable Air Conditioner cap. 2.0 ton from any posn. and removing unserviceable burnt sealed unit ( compressor ) from AC and S & Fix new compressor unit and testing on required pressure and installing at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item. (Make of compressor : VOLTAS/ BLUESTAR/ Lloyd/ carrier)
Disconnecting & Taking down unserviceable Automatic Voltage Stabilizer 4/5 KVA rating (provided for AC only. Checking & Reair of Operating Relays, Timer Relay, Relay Coil & its coneections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Transformer, high/low voltage output fault. Installing at its original position after repair and testing all as specified and directed. Note :- Major Items for repair will be measured under relavant items.
Supply in replacement of set of Relay 04P. Relay 25 Amp - Qty 04 Nos & 01P. Relay 25 Amp (12volts)-Qty 01 No. All as specified & directed.
Supply in replacement of Timer relay for 1.5/2.0 TR AC. All as specified & directed.
Supply in replacement of Auto Swing Synchronous Motor having 5-6 rpm, 230 Volts, 50 Hz, 3 W suitable for 1.5/2.0 TR AC. All as specified & directed.
Supply in replacement of Blower/Condensor Fan PVC body matching to existing blower, suitable for window type AC 1.5/2.0 TR. All as specified & directed.
Supply in replacement of Blower/Condensor Fan 708/102 mm PVC body matching to existing blower, suitable for Split type AC 1.5/2.0 TR. All as specified & directed.
Supply in replacement of Capacitor AC 40-45 mfd matching to existing rating capacitor, suitable for compressor of window AC 1.5/2.0 TR. All as specified & directed.
M&L for checking of unsv PCB board of window/Split type AC 1.5/2.0 TR for cleaning of PCB by applying cleaning solution, testing of circuits, replacement of transistor/ IC's, soldering work, AC to DC converter etc. and assembling the same after testing and working satsfactory to the engr-in-charge. All as directed.
Supply in replacement of PCB board of window/ split type AC 1.5/2.0 TR all as specified and directed
M&L for Servicing of installed Water Cooler of capacity 40/40, 40/80 & 150 Ltr of any make including taking down, dismantling from any position, disconnecting all electricl/water connections, testing of compressor functionability, testing for gas leakage/arrest of leakage, pressure of refrigerant, testing of Fan Motor, checking of flexible drain pipe, water inlet/outlet PVC pipe, checking of float valve, checking of Thermostate, operating knobs & Copper Capillary tubes, Cleaning of Cooling Coils & Fin using Bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing of moving parts and reassembling the same complete all as specified and directed. Note :- Various check to be done during servicing of Water Cooler any type any capacity and spares/items required for replacement of unsv spare/item will be measured under relavant items.
Taking down unserviceable water cooler 40/80 litre cap from any posn and removing unserviceable burnt sealed unit ( compressor ) from water cooler and S & Fix new compressor unit and testing on required pressure and installing cooler at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item. (Make of compressor : USHA / SIDWALL / COOLSTAR / SRIRAM)
Taking down unserviceable water cooler 120/150 litre cap. from any posn. and removing unserviceable burnt sealed unit ( compressor ) from cooler and S & F new compressor unit and testing on required pressure and installing cooler at its original posn. all as spec ified and directed. Note : Cost of filling with refrigerant gas is included in unit rate of this item. (Make of compressor : USHA / SIDWALL / COOLSTAR / SRIRAM)
Supply & replacement of thermostat switch suitable for water coolers including knobs, plate and screws for 40/80/150 ltr capacity complete all as specified and directed. (Make : RANUTRAL / DENFOSS)
Supply and replacement Running Capacitor suitable for water cooler 40/80/120/150 ltr capacity complete all as specified and directed. (Make : USHA/ UNISTAR)
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 120/150 ltr complete as as specified and directed.
Supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/80 ltr complete as as specified and directed.
Supplying and replacement of Over Load Protection Relay for Water cooler 120/150 litre cap. complete all as directed. (Make : RENUTROL/ SRI RAM / Indofoss)
Supplying and replacement of Over Load Protection Relay for Water cooler 40/ 80 litre cap. complete all as directed. (Make : RENUTROL/ SRI RAM / Indofoss)
Supplying and replacement of Starting Capacitor for Water Cooler 120/150 litre cap. complete all as directed.
Supplying and replacement of Starting Capacitor for Water Cooler 40/80 litre cap. complete all as directed.
Taking down unserviceable Fan Motor of Water Cooler of 120/150 litres capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting , clips and commissioning and testing complete all as specified and directed complete all as specified and directed.
Taking down unserviceable fan motor of water cooler of 40/80 ltr capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting, clips and commissioning and testing complete all as specified and directed complete all as specified and directed.
Taking down old unserviceable Fan Motor & S&F new Fan Motor suitable for water cooler of cap 40/80 ltrs capacity. (Make COOL HOME/ AUE/ CROMPTON) of following coapacity.
Taking down old unserviceableFan Motor of Water Cooler 120/150 Ltr. S&F new fan motor suitable for the same Water Cooler. (Make COOL HOME/ AUE/ CROMPTON) NOTE : All items retrieved from this sec of sch. shall be property of contractor and contractor shall lafford credit for this account as per sch of credit.
Supply and replacement stainless steel water tap 15 mm dia, pressing type, self releasing, chromium plated push cock heavy duty (as per existing) complete all as specified and directed.
Cleaning of water cooler body of capacity 40/40, 40/80/150 ltrs internally and externally including scraping and removing all scales and dirt etc. Repair to body to stop leakage and replacing unserviceable screws, nut & bolts etc. spray painting of water cooler with synthetic enamel paint hammer tone paint including prepairation of surfaces and applying red oxide primer all as directed at site.
Supplying and replacement PVC flexible copper cable 3 core 40/0.0076 length complete all specified and directed.
Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the Compressor of Water Cooler of any capacity and type for satisfactory performance complete all as directed by Engineer-in-Charge.
supply in replacement of Stailless Steel Basin Tray of water Cooler 40/80/150 Ltr. All as directed by engr-in-charge.
Supply in replacement of Drain pipe flexible of size 1.5 inches long upto 1.5 mtr suitable for 40/80/150 Ltr capacity water cooler. All as directed by engr-in-charge.
Supply in replacement of Water Inlet PVC pipe of 15 mm size including connecting to the water supply point to water cooler storage tank inlet point & ensure for no leakage of water from both points, suitable for 40/80/150 Ltr capacity water cooler. All as directed by engr-in-charge.
Supply in replacement of Float Ball & Valve Assembely matching to the existing unsv float Ball & Assembely including fixing suitable for 40/80/150 Ltr capacity water cooler. All as directed by engr-in-charge.
Supply in replacement of Copper Capilary tube of dia 0.026 mm upto 8 to 10 feet length including High/Low Pressure convertor device, matching to the existing unsv device & capilary tubes including fixing suitable for 40/80/150 Ltr capacity water cooler. All as directed by engr-in-charge.
M&L for Servicing of installed Refrigerator 180/300/310/315 Ltr capacity and Deep Freezer of capacity 320 Ltr of any make including taking down, dismantling from site, disconnecting all electricl connections, testing of compressor for functionability, pressure of refrigerant, checking of Thermostate, operating buttons, testing of PCB Board & Copper Capillary tubes, Cleaning of Condensor Coils from inner side using Bubble method by applying chemical solution, cleaning with brush, washing with pressure water, oiling/greecing of moving parts icludingprovinding minor nut/screws et.c and reassembling the same complete all as specified and directed. Note :- Various check to be done during servicing of Refrigerator & Deep Freezer any type any capacity and spares/items required for replacement being unsv will be measured under relavant items.
Taking down unserviceable Refrigerator 300/310/315 Ltr capacity from the site and transporting to workshop for repair, removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as directed by Engr-in-Charge. (Make : SRIRAM / KIRLOSKAR)
Taking down unserviceable Refrigerator 180 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as directed by Engr-in-Charge. (Make : SRIRAM / KIRLOSKAR)
Taking down unserviceable Deep Freezer 300/320 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) from the refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as directed by Engr-in-Charge. (Make : SRIRAM / KIRLOSKAR)
Recharging of Refrigerant Gas R-134A complete including testing of leakage and testing the Compressor of Refrigerator/Deep freezer of any capacity and type for satisfactory performance complete all as directed by Engineer-in-Charge.
Supply in replacement of Copper Capilary tube of dia 0.031 mm having lenth upto 8 to 10 feet including High/Low Pressure convertor device, matching to the existing unsv device including fixing of the same suitable for 310/315/320 Ltr capacity Refrigerator/Deep Freezer. All as directed by engr-in-charge.
Supply & Fixing as in repairs lce Tray plastic as per original all as directed.
Supply &Fixing as in repairs fruit/ vegitable Tray as per original all as directed.
Supply & Fixing as in repairs fruit/vagitable Glass cover complete as per original.
Supply and replacement of pigmy Lamps (bulb) of refrigerator complete as per existing complete all specified and directed.
Supply & Fixing as in repairs Refrigerator door seal (gasket)/flexible elastic strip attached to the outer edge of refrigerator or freezer compartment in the Refrigerator/Deep Freezer of cap 180/310/315/320 Ltr. All as specified and directd.
Supply & Fixing as in repairs door megmetic gasket complete as per original make for refrigerator 300/310 ltr capacity complete all as directed by Engr-in-Charge.
Supplying and replacement Relay Box type for 310/315 Ltr capacity refrigerator complete all specified and directed. (Make : RENUTROL/ SRI RAM)
Supplying and replacement of Over Load Protector Single Phase 230 Volts, 50 Hz suitable for Refrigerator/Deep Freezer 180/300/310/315 Ltr capacity (Make : Renutral/ SRI RAM) complete all as directed by Engr-in-Charge.
Supplying and replacement of door lock with two keys as per original specification for Refrigerator 180/310/315 Ltr complete all as directed by Engr-in-Charge.
M&L for spray painting of refrigerator with synithetic enamel paint over a coat of red oxide primer after preparation of surface of refrigerator coapacity 165 to 300 ltr of any make /model complete all as specified and directed.
Supplying and replacement of drian water Collector container made of PVC suitable for Refrigerator 180/300/310/315 Ltr Capacity complete all as directed by Engr-in-Charge.
Supplying and replacement of Copper Filter Drier in Refrigerator 180/310/315 Ltr capacity complete all as directed by Engr-in-Charge.
Disconnecting & Taking down unserviceable Automatic Voltage Stabilizer upto 2 KVA rating connected to Refrigerator/Deep Freezer/Water Coolers. Carry out repair to Operating Relays, Timer Relay, Relay Coil & its connections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Soldering work, Transformer, high/low voltage output fault. Installing at its original position after repair and testing all as specified and directed. Note :- Cost of spares/parts required to be replacement will be included in quoted rate.
Supplying and replacement of Indian Thermostate for single door/double door Refigerator 180/310/315 Ltr/Deep Freezer 320 Ltr as per existing rating of thermostate compatible for Voltas/ Samsung/ Usha/ Blue Star/ Kelvinator/ Godrej/ Whirlpool complete all as directed by Engr-in-Charge.
R N Enterprises
m/s s.n. builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .