Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹26.8 L+₹80,557 (3.10%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹27.8 L+₹1.8 L (6.91%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹29.5 L+₹3.5 L (13.4%)Accepted-Finance 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L4 | Accepted-Finance OK | |
| 5 | L5₹31.0 L+₹5.0 L (19.3%)Accepted-Finance | L5 | Accepted-Finance OK |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Jun 2023, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR/REPLACEMENT AND MAINTENANCE OF LT DISTRIBUTION SYSTEM, LT PANELS, LT CABLES AND CONNECTED ALLIED WORKS UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
2023_MES_600408_1
GE(U)/SEC/TOKEN/16 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹70,000
Yes
1 Aug 2023
2 Jun 2023
5 Jul 2023
2 Jun 2023
28 Jun 2023
16 Jun 2023
Amount
M&L for attending, repair and rectification of external LT/HT electric supply complaints on 11000/1100 Volts grade, under ground / over head system along with necessary T & P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor /Street light /Solar light area and clearing the OH Line of any type and size for one street light/one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
Replacement of faulty LT switch gear of any type and size fixed in panel board pole mounted boxes on walls or any other indicated places including provision of lugs/thimbles of suitable sizes. Note: - Switch gears will be measured and paid separately under relevant items of this schedule.
Replacement of blown out DO fuse, 11 KV grade of any capacity. Notes: (i) Quoted rate is deemed to be inclusive of Fuse wire of required gauge and necessary T & P required at site. (ii) No additional payments will be admissible for replacement of fuse in same system with an hour. (iii) Set of 3 fuses will be considered as one job for payment purpose.
Dismantling of cross arms of Ms channel of angle setion for issue of schedule of credit
Taking down LT over head line ACSR Conductor from pole / insulator complete with guarding & cradlesall as specified and as directed .
Dismantling of steel poles/ concrete poles of an site an location for issue of schedule of credit
Notes for Item Nos 1.01 to 1.06 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaints within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engineer-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify authorised rep/Engineer-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventoy format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No I store on daily basis.
Supply only the following materials as in repairs/replacements complete all as specified and directed. Note : Any modification/ alteration in existing panel which is required to fixing of MCCB is deemed to be included in unit rate
MCCB 63 Amps, 3 pole, 415 Volts with rapturing capacity 16 KA, fixed magnetic and thermal settings
MCCB 63 Amps, 4 pole, 415 Volts with rapturing capacity 16 KA, fixed magnetic and thermal settings
MCCB 100 Amps, 3pole, 415 Volts with rapturing capacity 16 KA, fixed magnetic and thermal settings
MCCB 100 Amps, 4 pole, 415 Volts with rapturing capacity 16 KA, fixed magnetic and thermal settings adjustable thermal and fixed magnetic settings.
MCCB 160 Amps, 3 pole, 415 Volts with rapturing capacity 36 KA adjustable thermal and fixed magnetic settings.
MCCB 160 Amps, 4 pole, 415 Volts with rapturing capacity 36 KA adjustable thermal and fixed magnetic settings.
MCCB 200 Amps, 3 pole, 415 Volts with rapturing capacity 36 KA adjustable thermal and fixed magnetic settings.
MCCB 200 Amps, 4 pole, 415 Volts with rapturing capacity 36 KA adjustable thermal and fixed magnetic settings.
MCCB 250 Amps, 3 pole, 415 Volts with rapturing capacity 36 KA adjustable thermal and fixed magnetic settings.
MCCB 250 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA adjustable thermal and fixed magnetic settings.
MCCB 400 Amps, 4 pole, 415 Volts with rapturing capacity 50 KA adjustable magnetic and thermal settings.
Dismantling LT steel tubuler pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
Supply and fix Power contactor coil of Power contactor of having capacity 360/400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS94195 or equivalent as approved by GE
Supply and fix Power contactor of having capacity 400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- C&S Cat part No LC1 FDP3304AE or equivalent as approved by GE.
Supply and fix Power contactor of having capacity 400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS97025 or equivalent as approved by GE.
Supply and fix Power contactor of having capacity 360 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS97024 or equivalent as approved by GE.
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through heat shinkble joint with jointing material and accessories suitable for aluminum conductor cable of size upto 120 sqmm, 3.5 Core complete all as specified and directed.
All as per item No 08 here-in-before but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 240 Sqmm, 3.5 Core
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminum conductor of following sizes complete all as specified and directed :- Note: Excavation, earth work, sand cushioning and cable protection items etc shall be measured and paid under respective items of BOQ.
4 core X 10 Sqmm
4 Core X 16 Sqmm
4 Core X 25 Sqmm
3.5 Core X 35 Sqmm
3.5 Core X 50 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 185 Sqmm
3.5 Core X 240Sqmm
M & L for testing earthing of installations, buildings, equipment etc and treating of earthings by pouring salt water and submit results sheet to AGE E/M No-I complete all as specified and directed. Note: Contractor has to arrange necessary tools required for the job
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
All as per item No 12 here in before but depth above 1.5 m & below 3 m
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Lay reinforced precast concrete cable cover LV, Type I,flat, size 250x150x40 mm complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate set in cement mortar 1:4 as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed.
M&L brick protection with common burnt brick sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed by Engineer-in-charge.
M & L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm center to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M & L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 2 coats of aluminium paint over a coat of red oxide primer including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminum paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M&L Pipe bracket for street light fitting made out of 40mm dia GI pipe, medium grade, tubing bend to shape, 1.5m long fixed to pole wall including provn of two sets of clamps made out of flat iron of size 40x6 mm including of provn of bolts, nuts and washers complete all as specified and directed.
S&F in repairs surge protection of 10 KV suitable upto 100W LED light fittings suitable to operate on input voltage 440 AC, 50 Hz, complete all as specified and directed. Make: C&S / Havells/ Cromption cat part No 5RPSQ10KV/5KV-440 as approved by GE.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor 3 core of size 2.5 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 4.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 6.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay Galvanised Iron tubing 40mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified and directed.
All as per item No 31 above but GI tubing 50 mm bore.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed
Demolition of coping of pole as required for placing of cable protection pipe and making good the same by using PCC complete al as speccified and directed. Note: Quoted rates are deemed to be inclusive of PCC
Taking out and Relaying of LT cable of size 10sq mm to 120 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engineer in charge. Note: Earth work, sand cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item.
Taking down old unsv Street light fittings in any position of any capacity, Repair of street light fittings by replacement of unsv spares and re-fixing the same in existing location. Note:- Spares for repair of street light fittings will be measured and paid under respective items.
Servicing of ACB 4 pole 415 Volt up to 1000 amps including tripping test complete all as specified and directed
S&F On- load changeover switch in open execution with front handle operating system, powder coated, factory made of capacity 200 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed.
S&F On- load changeover switch in open execution with front handle operating system, powder coated, factory made of capacity 400 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and direct
S&F Off- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 200Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed
S&F new generation energy saving and environmental friendly long life versatile pressure die cast aluminum IP66 road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper PVC insulated three core weather proof cable etc, including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed.
S & F in replacement of LED flood fitting of 150W pressure die cast aluminium body , IP66 on existing pole with provisioning of 2 runs of cable PVC insulated single core unsheathed 1100 volts grade 4 Sqmm multistranded with aluminium conductor from fitting to junction box complete all as specified and directed.
S & F in replacement of LED flood fitting of 200W pressure die cast aluminium body , IP66 on existing pole with provisioning of 2 runs of cable PVC insulated single core unsheathed 1100 volts grade 4 Sqmm multistranded with aluminium conductor from fitting to junction box complete all as specified and directed.
S&F in repairs post of top lantern pure polyester UV resistant power coated die cast aluminum housing with PMMA clear diffuser for uniform illumination IP65 LED as light source of capacity 25 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper conductor PVC insulated three core weather proof cable etc, including taking down old unserviceable gate light fitting of any type and capacity complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded copper conductor 3 core of size 2.5Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply and Fix 25 mm dia PVC pipes of suitable pressure rating laid in trenches complete all as specified and directed
S&F in repairs Electronic drivers suitable for 90W LED light fittings suitable to operate on input voltage of AC 100-265 V, 50 Hz, Output DC 36 V, max 350 MA, 0.95 PF complete all as specified and directed.
Supply and fix cable junction box thermoplastic body IP 66 , size 210mmx140mmx115mm suitable for helogen free and weather proof for out door installation with metric knockout for cable entry suitable for cable size 10-16 sqmm including clamp, lugs,cable terminal & 6-10 amps MCB complete all as specified and directed.
S&F Weather proof outdoor bus bar chamber, made out of 3 mm thick MS sheet duly powder quoted comprising 4 Nos aluminium strips each of 200Amps, 60cm long duly insulated mounted on insulators including MCCB 160 Amp with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 60cm x 105cm (30cm depth below ground level and 75cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed.
Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board indoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 800 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-
M & L for maintenence free safe earthing electrode (SEE) designed pipe in pipe technology, Only 1 No earth pit duly connected with copper earth strip 25 mm x 3 mm, earth pit having outer pipe of size 76.3mm dia and inner pipe of size 42.4 mm dia, each GI pipe have 2mtr long duly zinc and alloy coated having zinc coating (80-100) microns to whole length of pipe and alloy coating 250-300 micron to upper 300mm length of pipe, inside filled with crystal conductive compound (CCC) having anti corrosive and conductive properties to provide annular space of earth electrode and external black fill compound two bag of 25 kg mixed with soil all arround the earth pipe for retaining moisture, reduce the soil resistivity and dissipation of fault current, connected to earthing test point including excavation, earth work, PCC pit, RCC cover 50 mm thick, lifting rod 8mm dia, GI protection pipe 40 mm dia light grade for protection of inter connecting earthing strip from mechanical protection and testing on completion, complete all as specified and directed.
Supply and fixing Copper Strip 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground to interconnect the earth pit to equipment room Note: (a) Copper sockets and connector bolts nuts washers and drilling holes shall deemed to be included in the unit rate quoteed. (b) Excavation and earth work where ever required shall be carried out in this item only (c) On testing after completion of earthing earth restiance shall be less than 1 Ohm complete all as specified and directed by Engineer -in - charge
Supply & Fill distilled water in batteries of solar street lights of any capacity and any height all as specified and directed by Engineer in charge.
Supply & Fixing of 30W LED Solar Street Lights with enbuilt lithium battery all as specified and directed by Engineer in charge. Make : Cat Part No LSTSOL30N of LUKER or equivalent as approved by GE.
Supply & Fixing of 50W TRI Colour Light Column ,LED Light column with die-cast aluminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage & IP65 Proytection with tricolour and tratic white output switch all as specified and directed by Engineer in charge. Make : Cat Part No BLSLC 50W LED TRI 4M of BAJAJ or equivalent as approved by GE.
S& F in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminum lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 25 Sqmm including necessary connection complete all as specified and directed.
All as per item No 55 above but aluminium lugs of size 35 Sq mm.
All as per item No 55 here-in-before but aluminium lugs of size 50 Sq mm.
All as per item No 55 here-in-before but aluminium lugs of size 70 Sq mm.
All as per item No 55 here-in-before but aluminium lugs of size 95 Sq mm.
All as per item No 55 here-in-before but aluminium lugs of size 120 Sq mm.
All as per item No 55 here-in-before but aluminium lugs of size 150 Sq mm.
All as per item No 55 here-in-before but aluminium lugs of size 185/240 Sq mm.
S&F conneting and testing MCB isolator Single pole and neutral (SPN) 240 Volts of capaciyt 40 A 10 KA 50 "B" curve complete Make:- Indoasian Cat part No. 811031 or equivalent as approved by GE.
S&F conneting and testing MCB isolator three pole and neutral (TPN) 415 Volts of capaciyt 40 A 16 KA 50 "c" curve complete
S&F connecting and testing MCB isolator three pole and neutral (TPN) 415 volts of capacity 63 A 16 KA 50 "c" curve complete
M & L for digital voltmeter of range 0 to 500 volts and size 96 mm square dial including taking down old defective voltmeter and wiring if any required complete all as specified and directed.
M & L for digital ammeter of range 0 to 500 volts and size 96 mm square dial including taking down old defective ammeter complete all as specified and directed.
Supply and fixing of water proof LED Lights- Water proof 6 watt led light RGB and all as specified and directed by Engineer-in-charge
Supply and fixing of LED Driver/Controller for Suitable to connect RGB Light all as specified and directed.
S&F cable route indicator for LT UG cable of 1100 volts bolted with 25x5 mm flate iron member of height 0.60 mtrs and 80 mm CI plate embeded in PCC 1:3:6 type C2 of size 15x15x20 cm block complete all as specified
Supply and fixing of 150 mm X 40 mm size GI Perforated type cable tray including Cover made out of 2mm thick GI sheet, including MS supports /Threaded rods and anchor fasteners whereever required as per site conditions complete all as specified and directed.
M&L for repairing of automatic operation of highmast lantren including all arrangements required including crane and replacement of all unserviceable spares of highmast lighting system of height 12 m to 16 meter . Note : Quoted rates are deemed to be inclusive of the following:- (i) crane as required for taking down of high mast pole including light without any damage to the mast, lantern and lights etc and refixing the same after repairing of the all problem on the same position (ii) Necessary disconnection and reconnection of electrical connection. (iii) Replacement of all unserviceable spare like High mast head, high mast ring , stainless steel wire, clamp, winch, transition plate, service door , Hook ring, nose plate, cabinet, gear, reel, transmission belt etc including servicing of gear box , filling of gear oil, greasing etc complete (quoted rates deemed to be inclusive of all spares required for proper functioning of lantern system except stainless steel wire, High mast head, high mast ring etc.
Supply only steel wire rope 6mm dia (7/19 construction) suitable for highmast system including u bolt complete all as directed
Taking down, transport to workshop , Re-winding of electric motor 3 phase installed at highmast pole of capacity upto 2.2/3 HP and refixing of the same including necessary arrangement complete all as directed
SUN LIGHT HOUSE
Srinivash Engineers
DPS sales and services india
SRI SAI RAM ENTERPRISES
L and S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .