SE,EUDC-VII,Ciss-Gomti,LESA,
33/11 K.V. Substation,sct-5D,Vrandavan Yojna,LESA, Lucknow.
FOR THE WORK OF-Replacement of damaged Distribution Transformer of different capacity under jurisdiction of E.E, E.U.D.D-Alambagh, LESA, Lucknow.
2020_MVVNL_443673_2
74/EUDC-VII/LESA/2019-20
Open Tender
Miscellaneous Works
Fixed-rate
365 days
Lucknow
As per tender document
2 documents required · 2 mandatory
₹1,180
A/CNo-1277784945,IFSC Code-CBIN0280140,
₹10,000
20 May 2020
30 Apr 2020
9 May 2020
30 Apr 2020
8 May 2020
30 Apr 2020
Amount
Disconnection and removal of Damaged Transformer from present system, safe carriage from site of damage to Transformer work shop Aliganj for DTC. The work include loading, Unloding and safe carriage with in the area of E.U.D.D.- Alambagh.
25 K.V.A. Transformer mounted on double pole/plinth.
63 K.V.A. Transformer mounted on double pole/plinth.
100/160 K.V.A. Transformer mounted on double pole/plinth.
250 K.V.A. Transformer mounted on four pole/plinth.
400 K.V.A. Transformer mounted on four pole/plinth.
630 K.V.A. Transformer mounted on plinth.
1000/990 K.V.A. Transformer mounted plinth.
Safe carriage of healthy Transformer from store work shop Aliganj to site of damage including loading, unloading, dragging. Mounting, properly connecting to the system and commissioning on load, within the area of E.U.D.D.- Alambagh.
25 K.V.A. Transformer mounted on double pole/plinth.
63 K.V.A. Transformer mounted on double pole/plinth.
100/160 K.V.A. Transformer mounted on double pole/plinth.
250 K.V.A. Transformer mounted on four pole/plinth.
400 K.V.A. Transformer mounted on four pole/plinth.
630 K.V.A. Transformer mounted on plinth.
1000/990 K.V.A. Transformer mounted plinth.
Safe carriage of Transformer Mobile trolley mounted with Transformer site. Putting it at damaged Transformer site safely. Connecting the trolley Transformer to restart the electrical system safely including all electrical work so that supply may be re-started by this trolley Transformer.
Safe return carriage of Transformer mobile trolley from damage Transformer site to Sub-Station or other site (as) the case may be after disconnection the trolley from the electrical system.
TIWARI INDUSTRIES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .